Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

Ion Stopping Powers and CT Numbers

One of the advantages of ion beam therapy is the steep dose gradient produced near the ion's range. Use of this advantage makes knowledge of the stopping powers for all materials through which the beam passes critical. Most treatment planning systems calculate dose distributions using depth dose data measured in water and an algorithm that converts the kilovoltage X-ray computed tomography (CT) number of a given material to its linear stopping power relative to water. Some materials present in kilovoltage scans of patients and simulation phantoms do not lie on the standard tissue conversion curve. The relative linear stopping powers (RLSPs) of 21 different tissue substitutes and positioning, registration, immobilization, and beamline materials were measured in beams of protons accelerated to energies of 155, 200, and 250 MeV; carbon ions accelerated to 290 MeV/n; and iron ions accelerated to 970 MeV/n. These same materials were scanned with both kilovoltage and megavoltage CT scanners to obtain their CT numbers. Measured RLSPs and CT numbers were compared with calculated and/or literature values. Relationships of RLSPs to physical densities, electronic densities, kilovoltage CT numbers, megavoltage CT numbers, and water equivalence values converted by a treatment planning system are given. Usage of CT numbers and substitution of measured values into treatment plans to provide accurate patient and phantom simulations are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Subsurface Structure in the Martian Polar Layered Deposits: The Deep Space 2 Impact Accelerometry Experiment

While primarily a technology demonstration mission, the New Millenium Mars Microprobes (also known as Deep Space 2, or simply DS2)will also provide the first in situ science measurements of the martian subsurface. The DS2 impact accelerometry experiment will provide both engineering data about the depth of probe emplacement and science data about the physical nature of the subsurface at the probes' landing sites. Little is known about the detailed physical properties or small-scale vertical structure of the subsurface at the DS2 landing site in the southern martian polar layered deposits. Imaging data from the Viking Orbiters and Mars Global Surveyor reveal alternating bands of light and dark material in this region with thicknesses at least as small as the limit of resolution, about 10 m. The overall composition of these layers is poorly constrained, but generally thought to be a mixture of dust and ice with the layers being caused by variations in the dust/ice ratio, or perhaps by dust deposits of different densities. Low thermal inertias in the region suggest that the top few centimeters of the surface are composed of a mantling of fine-grained dust. However, 3.5-cm radar returns indicate that the maximum depth of this dust is not greater than a few tens of centimeters. Thermal models generally agree that, while the layered deposits do provide a potential near-surface reservoir for ice, the uppermost few centimeters to meters in these regions are likely to be ice-free because of sublimation losses. Finally, while it is generally agreed that the layered deposits are the product of variations in the martian climate, no direct correlation has been made between band sequences and specific climate changes. Our intention is to shed light on some of these questions about the martian polar layered deposits by using the DS2 accelerometry experiment to determine the physical nature of the layered deposits, and to detect the presence of any subsurface layering of dust, ice, and/or rock. In the process, we will also determine the final resting depth of the two microprobes, an important parameter in the interpretation of other DS2 experiments.

Moersch, J. E.↗

Assembly and comparative genome analysis of a Patagonian Aureobasidium pullulans isolate reveals unexpected intraspecific variation

Aureobasidium pullulans is a yeast-like fungus with remarkable phenotypic plasticity widely studied for its importance for the pharmaceutical and food industries. So far, genomic studies with strains from all over the world suggest they constitute a genetically unstructured population, with no association by habitat. However, the mechanisms by which this genome supports so many phenotypic permutations are still poorly understood. Recent works have shown the importance of sequencing yeast genomes from extreme environments to increase the repertoire of phenotypic diversity of unconventional yeasts. In this study, we present the genomic draft of A. pullulans strain from a Patagonian yeast diversity hotspot, re-evaluate its taxonomic classification based on taxogenomic approaches, and annotate its genome with high-depth transcriptomic data. Here, our analysis suggests this isolate could be considered a novel variant at an early stage of the speciation process. The discovery of divergent strains in a genomically homogeneous group, such as A. pullulans, can be valuable in understanding the evolution of the species. The identification and characterization of new variants will not only allow finding unique traits of biotechnological importance, but also optimize the choice of strains whose phenotypes will be characterized, providing new elements to explore questions about plasticity and adaptation.

59 BASIC BIOLOGICAL SCIENCES↗

Overview of SIMS-Based Experimental Studies of Tracer Diffusion in Solids and Application to Mg Self-Diffusion

Tracer diffusivities provide the most fundamental information on diffusion in materials and are the foundation of robust diffusion databases. Compared to traditional radiotracer techniques that utilize radioactive isotopes, the secondary ion mass spectrometry (SIMS) based thin-film technique for tracer diffusion is based on the use of enriched stable isotopes that can be accurately profiled using SIMS. Experimental procedures & techniques that are utilized for the measurement of tracer diffusion coefficients are presented for pure magnesium, which presents some unique challenges due to the ease of oxidation. The development of a modified Shewmon-Rhines diffusion capsule for annealing Mg and an ultra-high vacuum (UHV) system for sputter deposition of Mg isotopes are discussed. Optimized conditions for accurate SIMS depth profiling in polycrystalline Mg are provided. An automated procedure for the correction of heat-up and cool-down times during tracer diffusion annealing is discussed. The non-linear fitting of a SIMS depth profile data using the thin film Gaussian solution to obtain the tracer diffusivity along with the background tracer concentration and tracer film thickness is discussed. An Arrhenius fit of the Mg self-diffusion data obtained using the low-temperature SIMS measurements from this study and the high-temperature radiotracer measurements of Shewmon and Rhines (1954) was found to be a good representation of both types of diffusion data that cover a broad range of temperatures between 250 - 627° C (523 900 K).

36 MATERIALS SCIENCE↗

Using gap-filled MAIAC AOD and WRF-Chem to estimate daily PM 2.5 concentrations at 1 km resolution in the Eastern United States

To link short-term exposures of air pollutants to health outcomes, scientists must use high temporal and spatial resolution estimates of PM 2.5 concentrations. We develop a daily PM 2.5 product at 1 × 1 km 2 spatial resolution across the eastern United States (east of 90° W) with the aid of 1 × 1 km 2 MAIAC aerosol optical depth (AOD) data, 36 × 36 km 2 WRF-Chem output, 1 × 1 km 2 land-use type from the National Land Cover Database, and 0.125° × 0.125° ERA-Interim re-analysis meteorology. A gap-filling technique is applied to MAIAC AOD data to construct robust daily estimates of AOD when the satellite data are missing (e.g., areas obstructed by clouds or snow cover). The input data are incorporated into a multiple-linear regression model trained to surface observations of PM 2.5 from the EPA Air Quality System (AQS) monitoring network. The model generates a high-fidelity estimate (r 2 = 0.75 using a 10-fold random cross-validation) of daily PM 2.5 throughout the eastern United States. Of the inputs to the statistical model, WRF-Chem output (r 2 = 0.66) is the most important contributor to the skill of the model. MAIAC AOD is also a strong contributor (r 2 = 0.52). Daily PM 2.5 output from our statistical model can be easily integrated into county-level epidemiological studies. The novelty of this project is that we are able to simulate PM 2.5 in a computationally efficient manner that is constrained to ground monitors, satellite data, and chemical transport model output at high spatial resolution (1 × 1 km 2 ) without sacrificing the temporal resolution (daily) or spatial coverage (>2,000,000 km 2 ).

47 OTHER INSTRUMENTATION↗

Irradiation-induced swelling of pure chromium with 5 MeV Fe ions in the temperature range 450–650 °C

A surface coating using pure chromium has been proposed to increase the accident tolerance of Zircaloy cladding in pressurized water reactors. However, there is not much irradiation experience with Cr alloys and especially pure Cr. In the present study, pure chromium was irradiated with 5 MeV Fe ions to 50 peak dpa (displacements per atom) at temperatures of 450, 500, 550, 600 and 650 °C. Then irradiation at the peak swelling temperature of 550 °C was conducted to 50, 100, 150 peak dpa. Swelling at 50 dpa was observed over the entire temperature range studied, 450–650 °C, but appeared to be decreasing strongly at the temperature boundaries of the experiment. After an initial transient of rapid swelling, chromium was observed to swell at a rate of ~0.03–0.04%/dpa (up to 120 local dpa), which is much lower than pure Fe at 0.2%/dpa. This low swelling rate was found to be relatively insensitive to dpa rate, which varied by a factor of ~2 over the depth of data collection. Here, swelling was observed to begin quickly with an incubation period less than 10 dpa. Self-organization in the form of void ordering was observed to be developing at 50 dpa, becoming better defined with increasing dose. The void alignment direction is determined to be the $\langle$111$\rangle$ axial direction.

36 MATERIALS SCIENCE↗

Verifying and assessing the performance of the perturbation strategy in polynomial chaos ensemble forecasts of the circulation in the Gulf of Mexico

Here we present an analysis of two recent efforts aimed at quantifying the uncertainties in a 30-day HYbrid Coordinate Ocean Model forecast of the circulation in the Gulf of Mexico, with particular emphasis on the separation of Loop Current Eddy Franklin, using Polynomial Chaos methods. The analysis herein explores whether the model perturbations lead to realistic representation of the uncertainty in the Gulf Circulation. Comparisons of model output with Sea Surface Height and current mooring data show that the observational data generally falls within the envelope of the ensemble and that the modal decomposition delivers “realistic” perturbations in the Loop Current region. We use information theory metrics to quantify the information gain and the computational trade-offs between different wind and initial conditions perturbation modes. The relative entropy measures indicate that two modes for initial condition perturbations are enough, in our model configuration, to represent the uncertainty in the Loop Current region; while two modes for wind forcing perturbations are necessary in order to estimate the uncertainty in the coastal zone. The ensemble statistics are then explored using the Polynomial Chaos surrogate and the newly developed contour boxplot methods.

54 ENVIRONMENTAL SCIENCES↗

Subduction, Underplating, and Return Flow Recorded in the Cycladic Blueschist Unit Exposed on Syros, Greece

Exhumed high-pressure/low-temperature (HP/LT) metamorphic rocks provide insights into deep (~20–70 km) subduction interface dynamics. On Syros Island (Cyclades, Greece), the Cycladic Blueschist Unit preserves blueschist-to-eclogite facies oceanic- and continental-affinity rocks that record the structural and thermal evolution linked to Eocene subduction. Despite decades of research, the metamorphic and deformation history (P-T-D) and timing of subduction and exhumation are matters of ongoing discussion. We suggest that Syros comprises three coherent tectonic slices and that each slice underwent subduction, underplating, and syn-subduction return flow along similar P-T trajectories, but at progressively younger times. Subduction and exhumation are distinguished by lineations and ductile fold axis orientations, and are kinematically consistent with previous studies that document top-to-the-S-SW shear (prograde-to-peak subduction), top-to-the-NE shear (blueschist facies exhumation), and then E-W coaxial stretching (greenschist facies exhumation). Amphibole zonations record cooling during decompression, indicating return flow above a cold slab. Multi-mineral Rb-Sr isochrons and compiled metamorphic geochronology show that the three slices record distinct stages of peak subduction (53–52, ~50, and 45 Ma) that young with structural depth. Retrograde blueschist and greenschist facies fabrics span ~50–40 and ~43–20 Ma, respectively, and also young with structural depth. Synthesized data sets support a revised tectonic framework for Syros, involving subduction of structurally distinct coherent slices and simultaneous return flow of previously accreted tectonic slices in the subduction channel shear zone. Distributed, ductile, dominantly coaxial return flow in an Eocene-Oligocene subduction channel proceeded at rates of ~1.5–5 mm/yr and accommodated ~80% of the total exhumation of this HP/LT complex.

58 GEOSCIENCES↗

Comparison of Mg-based liquid metal ion sources for scalable focused-ion-implantation doping of GaN

We compare the suitability of various magnesium-based liquid metal alloy ion sources (LMAISs) for scalable focused-ion-beam (FIB) implantation doping of GaN. We consider GaMg, MgSO 4 $\bullet$7H 2 O, MgZn, AlMg, and AuMgSi alloys. Although issues of oxidation (GaMg), decomposition (MgSO 4 $\bullet$7H 2 O), and excessive vapor pressure (MgZn and AlMg) were encountered, the AuMgSi alloy LMAIS operating in a Wien-filtered FIB column emits all Mg isotopes in singly and doubly charged ionization states. We discuss the operating conditions to achieve <20 nm spot size Mg FIB implantation and present Mg depth profile data from time-of-flight secondary ion mass spectrometry. We also provide insight into implantation damage and recovery based on cathodoluminescence spectroscopy before and after rapid thermal processing. Prospects for incorporating the Mg LMAIS into high-power electronic device fabrication are also discussed.

36 MATERIALS SCIENCE↗

THE Pan-STARRS1 PHOTOMETRIC SYSTEM

The Pan-STARRS1 survey is collecting multi-epoch, multi-color observations of the sky north of declination -30 Degree-Sign to unprecedented depths. These data are being photometrically and astrometrically calibrated and will serve as a reference for many other purposes. In this paper, we present our determination of the Pan-STARRS1 photometric system: g{sub P1}, r{sub P1}, i{sub P1}, z{sub P1}, y{sub P1}, and w{sub P1}. The Pan-STARRS1 photometric system is fundamentally based on the Hubble Space Telescope Calspec spectrophotometric observations, which in turn are fundamentally based on models of white dwarf atmospheres. We define the Pan-STARRS1 magnitude system and describe in detail our measurement of the system passbands, including both the instrumental sensitivity and atmospheric transmission functions. By-products, including transformations to other photometric systems, Galactic extinction, and stellar locus, are also provided. We close with a discussion of remaining systematic errors.

79 ASTRONOMY AND ASTROPHYSICS↗

Gallium-Doped Poly-Si:Ga/SiO 2 Passivated Emitters to n-Cz Wafers With iV oc >730 mV

Here, we form gallium-doped poly-Si:Ga/SiO 2 passivated contacts on n-type Czochralski (n-Cz) wafers using ion implantation of Ga and Ga-containing spin-on dopants. After annealing and passivation with Al 2 O 3 , the contacts exhibit i Voc values of >730 mV with corresponding Joe values of <5 fA/cm 2 . These are among the best-reported values for p-type poly-Si/SiO 2 contacts. Secondary ion mass spectroscopic depth profile data show that, in contrast to B, Ga does not pileup at the SiO 2 interface in agreement with its known high diffusivity in SiO 2 . This lack of Ga pileup may imply fewer dopant-related defects in the SiO 2 , compared with B dopants, and account for the excellent passivation.

14 SOLAR ENERGY↗

Coaxial laser absorption and optical emission spectroscopy of high-pressure aluminum monoxide

This work advances laser absorption spectroscopy with measurements of aluminum monoxide (AlO) temperature and column density in extreme pressure ( P > 60 bar) and temperature ( T > 4000 K) environments. Measurements of the AlO A 2 Π i – X 2 Σ + transition are made using a microelectromechanical system, tunable vertical cavity surface emitting laser (MEMS-VCSEL). Simultaneous emission measurements of the AlO B 2 Σ + – X 2 Σ + transition are made along a line of sight that is coaxial with the laser absorption. Absorption temperature fits agree with emission spectra for a T = 3200 K, P = 9 bar case. In cases with T > 4000 K, P > 60 bar, absorption fits match the ambient temperature while emission fits over-estimate it, owing to high optical depths. These data juxtapose passive and active spectroscopic methods and demonstrate the versatility of AlO laser absorption in high-pressure and high-temperature environments where experimental data remain scarce, and engineering models will benefit from refined measurements.

Daniel, K. A.↗

Fallon FORGE: Lithology Logs and Well 21-31 Drilling Data

This submission includes lithology logs for all Fallon FORGE area wells; determined from core, cuttings, and thin section. Wells included are 84-31, 21-31, 82-36, FOH-3D, 62-36, 18-5, 88-24, 86-25, FOH-2, 14-36, 17-16, 34-33, 35A-11, 51A-20, 62-15, 72-7, 86-15, Carson_Strat_1_36-32, and several others. Lithology logs last updated 3/13/2018 with confirmation well 21-31 data, and revisited existing wells. Also included is well logging data for Fallon FORGE 21-31. Well logging data includes daily reports, well logs (drill rate, lithology, fractures, mud losses, minerals, temperature, gases, and descriptions), mud reports, drilling parameter plots, daily mud loss summaries, survey reports, progress reports, plan view maps (easting, northing), and wireline logs (caliper [with GR], triple combo [GR, caliper, SP, resistivity, array induction, density, photoelectric factor, and neutron porosity], array induction with linear correlation [GR, SP, Array Induction, caliper, conductivity], and monopole compression dipole shear [GR, SP, Caliper, sonic porosity, delta-T compressional, and delta-T shear])

15 GEOTHERMAL ENERGY↗

SPRUCE Measurements of Fine Root Production and Chemistry from Root Ingrowth Cores, Marcell Experimental Forest, Minnesota, 2022-2023

This dataset contains fine root production and tissue chemistry measurements from root ingrowth cores. Ingrowth cores were deployed in peat from June 28, 2022 to June 24, 2023 (2022-06-28 to 2023-06-24) inside SPRUCE Experiment plots at the Marcell Experimental Forest in northern Minnesota. The warming and elevated carbon dioxide (CO2) treatments in this dataset include +0 degrees Celsius (C) (+0 and +500 parts per million (ppm) elevated CO2), +4.5 degrees C (+0 and +500 ppm elevated CO2) and +9 degrees C (+0 and +500 ppm elevated CO2) for both hummocks and hollows, as well as +2.25 degrees C (+0 and +500 ppm) and +6.75 degrees C (+0 and +500 ppm) for hollows from minimum 10 cm depth from the peat surface. Measurements include root average diameter, root length, root biomass, and root tissue nitrogen (%N and δ15N) and carbon (%C and δ13C) concentration per plant functional type and microtopographical feature. Root length and biomass are standardized to 10 cm depth. These data were used to assess the warming and elevated CO2 response of fine roots across different peatland microtopographical features (hummocks and hollows) and plant functional types (shrub, spruce and larch). This dataset contains one data file in comma separate (.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Statistical methods for the forensic analysis of striated tool marks

In forensics, fingerprints can be used to uniquely identify suspects in a crime. Similarly, a tool mark left at a crime scene can be used to identify the tool that was used. However, the current practice of identifying matching tool marks involves visual inspection of marks by forensic experts which can be a very subjective process. As a result, declared matches are often successfully challenged in court, so law enforcement agencies are particularly interested in encouraging research in more objective approaches. Our analysis is based on comparisons of profilometry data, essentially depth contours of a tool mark surface taken along a linear path. In current practice, for stronger support of a match or non-match, multiple marks are made in the lab under the same conditions by the suspect tool. We propose the use of a likelihood ratio test to analyze the difference between a sample of comparisons of lab tool marks to a field tool mark, against a sample of comparisons of two lab tool marks. Chumbley et al. (2010) point out that the angle of incidence between the tool and the marked surface can have a substantial impact on the tool mark and on the effectiveness of both manual and algorithmic matching procedures. To better address this problem, we describe how the analysis can be enhanced to model the effect of tool angle and allow for angle estimation for a tool mark left at a crime scene. With sufficient development, such methods may lead to more defensible forensic analyses.

97 MATHEMATICS AND COMPUTING↗

Corrective Action Management Unit Report of Post-Closure Care Activities Calendar Year 2017.

The Corrective Action Management Unit (CAMU) at Sandia National Laboratories, New Mexico (SNL/NM) consists of a containment cell and ancillary systems that underwent regulatory closure in 2003 in accordance with the Closure Plan in Appendix D of the Class 3 Permit Modification (SNL/NM September 1997). The containment cell was closed with wastes in place. On January 27, 2015, the New Mexico Environment Department (NMED) issued the Hazardous Waste Facility Operating Permit (Permit) for Sandia National Laboratories (NMED January 2015). The Permit became effective February 26, 2015. The CAMU is undergoing post-closure care in accordance with the Permit, as revised and updated. This CAMU Report of Post-Closure Care Activities documents all activities and results for Calendar Year (CY) 2017 as required by the Permit. The CAMU containment cell consists of engineered barriers including a cover system, a bottom liner with a leachate collection and removal system (LCRS), and a vadose zone monitoring system (VZMS). The VZMS provides information on soil conditions under the cell for early leak detection. The VZMS consists of three monitoring subsystems, which include the primary subliner (PSL), a vertical sensor array (VSA), and the Chemical Waste Landfill (CWL) sanitary sewer (CSS) line. The PSL, VSA, and CSS monitoring subsystems are monitored quarterly for soil moisture concentration, the VSA is monitored quarterly for soil temperature, and the VSA and CSS monitoring subsystems are monitored annually for volatile organic compound (VOC) concentrations in the soil vapor at various depths. Baseline data for the soil moisture, soil temperature, and soil vapor were established between October 2003 and September 2004.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗