Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc power systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

Study of Bulk and Elementary Screw Dislocation Assisted Reverse Breakdown in Low-Voltage (less than 250 V) 4H-SiC p(+)n Junction diodes: DC Properties - Part 1

Given the high density (approx. 10(exp 4)/sq cm) of elementary screw dislocations (Burgers vector = 1c with no hollow core) in commercial SiC wafers and epilayers, all appreciable current (greater than 1 A) SiC power devices will likely contain elementary screw dislocations for the foreseeable future. It is therefore important to ascertain the electrical impact of these defects, particularly in high-field vertical power device topologies where SiC is expected to enable large performance improvements in solid-state high-power systems. This paper compares the DC-measured reverse-breakdown characteristics of low-voltage (less than 250 V) small-area (less than 5 x 10(exp -4)/sq cm) 4H-SiC p(+)n diodes with and without elementary screw dislocations. Compared to screw dislocation-free devices, diodes containing elementary screw dislocations exhibited higher pre-breakdown reverse leakage currents, softer reverse breakdown I-V knees, and highly localized microplasmic breakdown current filaments. The observed localized 4H-SiC breakdown parallels microplasmic breakdowns observed in silicon and other semiconductors, in which space-charge effects limit current conduction through the local microplasma as reverse bias is increased.

Neudeck, Philip G.↗

Design and emplacement of an integrated lunar power system - Issues and concerns

Issues regarding the construction and operation of a stationary lunar surface power system that must be resolved in order to create a permanent manned presence on the moon are addressed. The issues considered include: (1) the centralization or decentralization of the electrical power system; (2) whether power transmission should be ac or dc; (3) what mix of power generating technology should be used; and (4) the physical interface requirements between the power-system hardware and the construction equipment to be used in placing the hardware on the lunar surface.

Sprouse, Kenneth M.↗

Application of small-signal modeling and measurement techniques to the stability analysis of an integrated switching-mode power system

Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.

Wong, R. C.↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 1MHz Oak Ridge AC / DC Converter for UAV Contactless Charger Implementation

In this paper, a 1 MHz single-phase Oak Ridge Converter (ORC) AC/DC wireless power transfer (WPT) system is introduced for unmanned air vehicle (UAV) charging applications. The proposed advanced solution eliminates the design, weight, volume, and the cost of the power factor correcting (PFC) front-end rectifier compared to the conventional practices. Additionally, grid power quality requirements can be achieved with the presented innovative idea. With this method, single stage WPT primary side uses the hybrid grid frequency and high frequency (60 Hz and 1 MHZ) from ac source through the coupler coils and to UAV battery with GaN FETs. Experimental results of the single-phase system is presented to confirm the mathematical analyses with the source voltage of 110 VAC, RMS and output voltage of 40 VDC at 1 kW power with 6 inches air gap between couplers. The primary coupler consists of a ferrite-backed single-turn coil with a radius of 1.5 ft, and the secondary coupler is made with an air-core single-turn coil with radius of 1.2 ft. The system overall ac to dc efficiency is measured 77 % acquiring 0.99 power factor (PF) and 3.3 % current total harmonic distortion (THD) at 1 kW power.

Asa, Erdem↗

Telescience operations with the solar array module plasma interaction experiment

The Solar Array Module Plasma Interactions Experiment (SAMPIE) is a flight experiment that flew on the Space Shuttle Columbia (STS-62) in March 1994, as part of the OAST-2 mission. The overall objective of SAMPIE was to determine the adverse environmental interactions within the space plasma of low earth orbit (LEO) on modern solar cells and space power system materials which are artificially biased to high positive and negative direct current (DC) voltages. The two environmental interactions of interest included high voltage arcing from the samples to the space plasma and parasitic current losses. High voltage arcing can cause physical damage to power system materials and shorten expected hardware life. parasitic current losses can reduce power system efficiency because electric currents generated in a power system drain into the surrounding plasma via parasitic resistance. The flight electronics included two programmable high voltage DC power supplies to bias the experiment samples, instruments to measure the surrounding plasma environment in the STS cargo bay, and the on-board data acquisition system (DAS). The DAS provided in-flight experiment control, data storage, and communications through the Goddard Space Flight Center (GSFC) Hitchhiker flight avionics to the GSFC Payload Operations Control Center (POCC). The DAS and the SAMPIE POCC computer systems were designed for telescience operations; this paper will focus on the experiences of the SAMPIE team regarding telescience development and operations from the GSFC POCC during STS-62. The SAMPIE conceptual development, hardware design, and system verification testing were accomplished at the NASA Lewis Research Center (LeRC). SAMPIE was developed under the In-Space Technology Experiment Program (IN-STEP), which sponsors NASA, industry, and university flight experiments designed to enable and enhance space flight technology. The IN-STEP Program is sponsored by the Office of Space Access and Technology (OSAT).

Wald, Lawrence W.↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

Precise time dissemination and applications development on the Bonneville Power Administration system

The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.

K. E. Martin↗

National Maglev initiative: California line electric utility power system requirements

The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

Save, Phil↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Highly Efficient Amplifier for Ka-Band Communications

An amplifier developed under a Small Business Innovation Research (SBIR) contract will have applications for both satellite and terrestrial communications. This power amplifier uses an innovative series bias arrangement of active devices to achieve over 40-percent efficiency at Ka-band frequencies with an output power of 0.66 W. The amplifier is fabricated on a 2.0- by 3.8-square millimeter chip through the use of Monolithic Microwave Integrated Circuit (MMIC) technology, and it uses state-of-the-art, Pseudomorphic High-Electron-Mobility Transistor (PHEMT) devices. Although the performance of the MMIC chip depends on these high-performance devices, the real innovations here are a unique series bias scheme, which results in a high-voltage chip supply, and careful design of the on-chip planar output stage combiner. This design concept has ramifications beyond the chip itself because it opens up the possibility of operation directly from a satellite power bus (usually 28 V) without a dc-dc converter. This will dramatically increase the overall system efficiency. Conventional microwave power amplifier designs utilize many devices all connected in parallel from the bias supply. This results in a low-bias voltage, typically 5 V, and a high bias current. With this configuration, substantial I(sup 2) R losses (current squared times resistance) may arise in the system bias-distribution network. By placing the devices in a series bias configuration, the total current is reduced, leading to reduced distribution losses. Careful design of the on-chip planar output stage power combiner is also important in minimizing losses. Using these concepts, a two-stage amplifier was designed for operation at 33 GHz and fabricated in a standard MMIC foundry process with 0.20-m PHEMT devices. Using a 20-V bias supply, the amplifier achieved efficiencies of over 40 percent with an output power of 0.66 W and a 16-dB gain over a 2-GHz bandwidth centered at 33 GHz. With a 28-V bias, a power level of 1.1 W was achieved with a 12-dB gain and a 36-percent efficiency. This represents the best reported combination of power and efficiency at this frequency. In addition to delivering excellent power and gain, this Ka-band MMIC power amplifier has an efficiency that is 10 percent greater than existing designs. The unique design offers an excellent match for spacecraft applications since the amplifier supply voltage is closely matched to the typical value of spacecraft bus voltage. These amplifiers may be used alone in applications of 1 W or less, or several may be combined or used in an array to produce moderate power, Ka-band transmitters with minimal power combining and less thermal stress owing to the combination of excellent efficiency and power output. The higher voltage operation of this design may also save mass and power because the dc-dc power converter is replaced with a simpler voltage regulator.

Source record↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Intelligent dc-dc Converter Technology Developed and Tested

The NASA Glenn Research Center and the Cleveland State University have developed a digitally controlled dc-dc converter to research the benefits of flexible, digital control on power electronics and systems. Initial research and testing has shown that conventional dc-dc converters can benefit from improved performance by using digital-signal processors and nonlinear control algorithms.

Button, Robert M.↗

Preliminary Reversible Solid Oxide System Specification

This report presents the preliminary documentation of a 10 MWe DC reversible solid oxide cell (rSOC) system designed to use both electrical and thermal energy from a nuclear power plant (NPP). The system is designed to consume 10 MWe DC in electrolysis mode while producing hydrogen from demineralized feedwater. In fuel cell mode, the same stacks produce 2.37 MWe DC of electricity by reacting hydrogen and oxygen, while generating water as a byproduct which is recycled to be used later in the electrolysis mode. The system detailed in this specification is a high-temperature steam electrolysis (HTSE) system when operated in the electrolysis mode. HTSE systems have the benefit of producing hydrogen at a higher efficiency than conventional low-temperature electrolysis (LTE) systems. In this report it is assumed that some of the heat required for HTSE operation comes from an NPP. Heat extraction from an NPP for use in electrolysis mode of the rSOC system allows preheating and vaporization of feedwater before recuperators and trim heaters raise the feed temperature to the approximately 800 °C before entering the solid oxide stacks. The purpose of an rSOC system in a utility company setting is to employ energy arbitrage with a dispatchable demand load which can consume excess electricity generation during times of low grid demand / high generation and can produce electricity for the grid during times of high grid demand / low generation. There is a wide range of energy storage technologies that could be used for utility-scale energy arbitrage (utility-scale battery storage is considered the baseline technology), the object of this work is not to compare and contrast rSOC technology with any of these other technologies, but only to present this preliminary design for consideration and for use in future conceptual or front end engineering design (FEED) work. This document is not meant to be a final specification or definitive description of the rSOC system, but it is meant to showcase preliminary process modeling results, provide boundary conditions and interface requirements such as input feed and utility stream flowrates, temperatures, and pressures as well as thermal and electrical energy requirements, and output conditions in both electrolysis mode and fuel cell mode. These results are intended to inform the future development of a conceptual demonstration-scale study to assess the technical and economic feasibility of a future demonstration of an rSOC integrated project at an NPP.

08 HYDROGEN↗

Design and performance of a no-single-failure control system for the mini-Brayton power conversion system

The control system consists of the ac-dc conversion, voltage regulation, speed regulation through parasitic load control, and overload control. A no-single-failure configuration was developed to attain the required reliability for a 10-year design life of unattended operation. The design principles, complete schematics, and performance are reported. Testing was performed on an alternator simulator pending construction of the actual Mini-Brayton alternator.

Brichenough, A. G.↗