Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Origin of fifteen cosmic dust particles intercepted by Pioneer 8 and 9

Consistent data for more than 8 years have been obtained from two identical cosmic dust particle experiments on board the space probes Pioneer 8 and 9. The two spacecraft are in direct heliocentric orbits with perihelia between 0.75 AU and 1.00 AU. On the basis of the data it is concluded that the majority of dust particles having elliptical orbits detected by the two space probes show orbital characteristics of Apollo group asteroids which originated from residual nuclei of short-period comets.

Rhee, J. W.↗

Shadowgraphs of air flow over prospective space shuttle configurations at Mach numbers from 0.8 to 1.4

Shadowgraphs of five space shuttle launch configurations are presented. The model was a 4 percent-scale space shuttle vehicle, tested in the 11- by 11-foot Transonic Wind Tunnel at Ames Research Center. The Mach number was varied from 0.8 to 1.4 with three angles of sideslip (0 deg, 5 deg and -5 deg) that were used in conjunction with three angles of attack (4 deg, -4 deg, and 0 deg). The model configurations included both series-burn and parallel-burn configurations, two canopy configurations, two positions of the orbiter nose relative to the HO tank nose, and two HO tank nose-cones angles (15 deg and 20 deg). The data consist entirely of shadowgraph photographs.

Dods, J. B., Jr.↗

The Skylab S019 ultraviolet spectra of HD 153919 (=3U 1700-37) and HDE 226868 (=Cyg X-1)

Ultraviolet spectra of HD153919 (=3U1700-37) and HDE226868 (=Cyg X-1) were obtained with the ultraviolet objective-prism spectrograph of Skylab Experiment S019. The data consist of unwidened spectra which extend to 1,600A for HD153919 and to 2,400A for HDE226868. The wavelength resolution is about 2A to 1,400A and 12A at 2,000A. For HD153919, an unwidened spectrum of fair quality and extending to a wavelength of 1,600A was obtained at 22 sup h 08 sup m on 1 September 1973. The energy distribution in this spectrum generally resembles that of other reddened O stars. A break in continuum intensity seems to occur at a wavelength of about 1,720A. There is a suggestion of an emission line on the longward edge of the break but this could be either a chance clumping of grains or else a photographic edge-effect caused by the break.

Kondo, Y.↗

Measurement of the fluxes of galactic cosmic-ray H-2 and He-3 in 1972-1973

This paper reports measurements of the fluxes of cosmic-ray H-2 and He-3 during 1972-1973, carried out by instruments on board the IMP-7 and Pioneer 10 spacecraft. Energy spectra are generally consistent with a positive slope of unity, as would be expected for modulated secondary components. A self-consistent data set is proposed spanning the period from 1965 to 1973 wherein all spectra have the same kinematic behavior. The measured spectra for 1972-1973 are compared with calculated interstellar spectra, and it is concluded that only very broad limits can be placed on the amount of modulation. Ratios of the form H-2/He-4 and He-3/He-4 are examined and compared with calculated values based on an assumed exponential path-length distribution for galactic propagation. It is concluded that unless extreme assumptions are made about the modulation (e.g., no energy loss), it is impossible to reconcile the simple theory and observation. A nearby source is apparently required to supply enough low-energy He-4 to account for the low values of the H-2/He-4 and He-3/He-4 ratios. The possible relationship between this source and the recently discovered enhancements of cosmic-ray N and O is discussed.

Teegarden, B. J.↗

Evidence for a 17-d periodicity from Cyg X-3

Data are presented from the Ariel-V All-Sky Monitor which indicate a 17-day periodicity of the X-ray spectra from Cyg X-3 (3U2030+40). The data are consistent with data from the Ariel V Sky Survey Experiment. Assuming that the high intensity state of Cyg X-3 is well fitted by a structureless black body (Serlemitsos et al., 1975), and that the 17-day maxima correspond to increased electron scattering in the source, it is suggested that the 17-day effect is analogous to the 35-day variation in Her X-1. The possible explanation of this phenomenon as a result of the 17-day orbital period of the binary system containing Cyg X-3 is severely constrained by the stability of the well-known 4.8-hour variation.

Holt, S. S.↗

Numerical solution of periodic transonic flow through a fan stage

A numerical method of solution of the inviscid, compressible, two-dimensional unsteady flow on a blade-to-blade stream surface through a stage (rotor and stator), or a single blade row, of an axial flow compressor or fan is described. A cyclic procedure has been developed for representation of adjacent blade-to-blade passages, which asymptotically achieves the correct phase between all passages of a stage. A shock-capturing finite-difference method is employed in the interior of the passage, and a method-of-characteristics technique is used at the boundaries. The blade slipstreams form two of the passage boundaries, and are treated as moving contact surfaces capable of supporting jumps in entropy and tangential velocity. The Kutta condition is imposed by requiring the slipstreams to originate at the trailing edges, which are assumed to be sharp. Results are presented for several transonic fan rotors, and compared with available experimental data consisting of holographic observations of shock structure and pressure contour maps. A subcritical stator solution is also compared with results from a relaxation method. Finally, a periodic solution for a stage consisting of 44 rotor blades and 46 stator blades is discussed.

Erdos, J. I.↗

Snow backscatter in the 1-8 GHz region

The 1-8 GHz microwave active spectrometer system was used to measure the backscatter response of snow covered ground. The scattering coefficient was measured for all linear polarization combinations at angles of incidence between nadir and 70 deg. Ground truth data consisted of soil moisture, soil temperature profile, snow depth, snow temperature profile, and snow water equivalent. The radar sensitivity to snow water equivalent increased in magnitude with increasing frequency and was almost angle independent for angles of incidence higher than 30 deg, particularly at the higher frequencies. In the 50 deg to 70 deg angular range and in the 6 to 8 GHz frequency range, the sensitivity was typically between -0.4 dB/.1 g/sq cm and -0.5 dB/,1 g/sq cm, and the associated linear correlation coefficient had a magnitude of about 0.8.

Ulaby, F. T.↗

Effects of Simulated Flight on Fan Noise Suppression

Attenuation properties of three treated fan inlets were evaluated. Tunnel flow simulated the inflow clean-up effect on source noise observed in flight and allowed observation of the blade passage frequency tone cut-off phenomenon. Acoustic data consisted of isolated inlet noise measured in the far field at two fixed positions and with traverses at four frequencies. Attenuation and source noise properties with and without flight simulation are compared and discussed. Averaged attenuation properties showed relative agreement of the inlets with their design intent, however, tunnel flow significantly affected the attenuation spectra.

Heidmann, M. F.↗

Effects of simulated flight on fan noise suppression

Attenuation properties of three treated fan inlets were evaluated in the NASA-Lewis Anechoic Wind Tunnel using a subsonic tip speed, 50.8 cm-diameter fan. Tunnel flow simulated the inflow clean-up effect on source noise observed in flight and allowed observation of the blade passage frequency tone cut-off phenomenon. Acoustic data consisted of isolated inlet noise measured in the far field at two positions and with traverses at four frequencies. Averaged attenuation properties showed relative agreement of the inlets with their design intent; however, tunnel flow significantly affected the attenuation spectra. With no tunnel flow the strong blade passage tone was more highly attenuated than the adjacent broadband noise. With tunnel flow, when cut-off was observed, the attenuation at the tone frequency was comparable to that for broadband noise. Tunnel flow increased by several dB the maximum attenuation occurring at midfrequencies of the attenuation spectra. The combined effect of tunnel flow on attenuation and source noise resulted in suppressed fan noise levels throughout the spectra. Tunnel flow caused some substantial directivity variations that are interpreted as acoustic mode changes, with tunnel flow generally reducing the proportion of modes near cut-off.

Heidmann, M. F.↗

Computation of unsteady transonic flows through rotating and stationary cascades. 1: Method of analysis

A numerical method of solution of the inviscid, compressible, two-dimensional unsteady flow on a blade-to-blade stream surface through a stage (rotor and stator) or a single blade row of an axial flow compressor or fan is described. A cyclic procedure has been developed for representation of adjacent blade-to-blade passages which asymptotically achieves the correct phase between all passages of a stage. A shock-capturing finite difference method is employed in the interior of the passage, and a method of characteristics technique is used at the boundaries. The blade slipstreams form two of the passage boundaries and are treated as moving contact surfaces capable of supporting jumps in entropy and tangential velocity. The Kutta condition is imposed by requiring the slipstreams to originate at the trailing edges, which are assumed to be sharp. Results are presented for several transonic fan rotors and compared with available experimental data, consisting of holographic observations of shock structure and pressure contour maps. A subcritical stator solution is also compared with results from a relaxation method. Finally, a periodic solution for a stage consisting of 44 rotor blades and 46 stator blades is discussed.

Erdos, J. I.↗

Interactive signal analysis and ultrasonic data collection system user's manual

The interactive signal analysis and ultrasonic data collection system (ECHO1) is a real time data acquisition and display system. ECHO1 executed on a PDP-11/45 computer under the RT11 real time operating system. Extensive operator interaction provided the requisite parameters to the data collection, calculation, and data modules. Data were acquired in real time from a pulse echo ultrasonic system using a Biomation Model 8100 transient recorder. The data consisted of 2084 intensity values representing the amplitude of pulses transmitted and received by the ultrasonic unit.

Smith, G. R.↗

Pioneer 10 and 11 radio occultations by Jupiter

Results on the temperature structure of the Jovian atmosphere are reviewed which were obtained by applying an integral inversion technique combined with a model for the planet's shape based on gravity data to Pioneer 10 and 11 radio-occultation data. The technique applied to obtain temperature profiles from the Pioneer data consisted of defining a center of refraction based on a computation of the radius of curvature in the plane of refraction and the normal direction to the equipotential surface at the closest approach point of a ray. Observations performed during the Pioneer 10 entry and exit and the Pioneer 11 exit are analyzed, sources of uncertainty are identified, and representative pressure-temperature profiles are presented which clearly show a temperature inversion between 10 and 100 mb. Effects of zonal winds on the reliability of radio-occultation temperature profiles are briefly discussed.

Kliore, A. J.↗

Sequential High-Resolution Wind Profile Measurements

Tropospheric flow and lower stratospheric flow as measured by 94 sequences of high-resolution Jimsphere balloon data are presented and discussed. The 70 and 24 sequential series are presented for the Kennedy Space Center, Florida, and Point Mugu, California, areas, respectively. Supplemental data, consisting of the associative temperature profiles and surface and 200 mb synoptic maps, are also presented. The measurements are discussed relative to both the engineering and disciplinary areas. An initial subjective analysis of mesoscale features observed on some sequences is presented.

Johnson, D. L.↗

Design and testing of a redundant skewed inertial sensor complex for integrated navigation and flight control

Requirements for a redundant strapdown inertial sensor complex applied to V/STOL aircraft as developed by NASA are presented. Flight test data of a redundant, skewed axis strapdown inertial system are given, demonstrating the feasibility of the primary design aspects. This data consisted of parity equation responses through various flight conditions, showing residual noise levels on redundant gyro and accelerometer comparisons as a measure of minimum failure-level detectability, plus failure isolation and navigation performance through several simulated instrument failures.

Ebner, R. E.↗

Orbit/attitude estimation with Landsat-1 and -2 landmark data

The accuracy of spacecraft orbit and attitude determination is investigated using Landsat-1 and -2 picture data. The data consists of ground control points, of known geodetic coordinates, which are identified on a series of Landsat pictures. Both sequential (extended Kalman filter) and batch (nonlinear Bayesian weighted least-squares) estimation techniques have been implemented in two software systems. Discussion of these systems includes a system overview, mathematical formulation, and sample numerical results. Particular emphasis is given to the application of a spectral analysis technique to derive spacecraft attitude models.

Hall, D. L.↗

Characterization of solar cells for space applications. Volume 11: Electrical characteristics of 2 ohm-cm, 228 micron wraparound solar cells as a function of intensity, temperature, and irradiation

Parametric characterization data on Spectrolab 2 by 4 cm, 2 ohm/cm, 228 micron thick wraparound cell, a candidate for the Solar Electric Propulsion Mission, are presented. These data consist of the electrical characteristics of the solar cell under a wide range of temperature and illumination intensity combinations of the type encountered in space applications.

Anspaugh, B. E.↗

Study of intermittent field hardware failure data in digital electronics

The collection and analysis of data concerning intermittent dailures in digital devices was performed using data from a computer design for shipboard usage. The failure data consisted of actual field failures classified by failure mechanisms and their likelihood of having been intermittent, potentially intermittent, or hard. Each class was studies with respect to computer operation in the ranges of 0 to 2,000 hours, 0 to 5, hours, and 0 to 10,000 hours. The study was done at the computer level as well as the microcircuit level. Results indicate that as age increases, the quasi-intermittent failure rate increases and the mean time to failure descreases.

Oneill, E. J.↗

Comparison of calculated and measured blade loads on a full-scale tilting proprotor in a wind tunnel

The loads measured in a wind tunnel on a full-scale tilting proprotor are compared with calculated results. The data consists primarily of oscillatory beamwise bending moments at 35% radial station, oscillatory spindle chord bending moments, and oscillatory pitch link loads. The measured and calculated results as a function of thrust are compared over a range of nacelle angles from 0 to 75 deg, and a range of speeds from 80 to 185 knots.

Johnson, W.↗