Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyber attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Cybersecurity Considerations for the Liquified Natural Gas Sector

Due to the highly volatile nature of Liquified Natural Gas (LNG) and the systems required for generation and safe containment, it is likely a targeted cyber-attack on LNG control and safety systems will have a significant economic impact on energy supplies and prices. Moreover, if the interconnected operational technology (OT) devices within LNG systems are exploited to malfunction, the repair and recertification process will almost certainly be longer than for natural gas (NG) systems.

03 NATURAL GAS↗

A Survey of Cyber Threat

Multiple companies are competing to develop human-crewed and unmanned aerial vehicles to provide flight in urban environments. With the growth of aerial systems and future airborne vehicle networks and the need to enable secure data exchange and service interactions within Urban Air Mobility (UAM) environments, cybersecurity has come to the forefront as a topic, highlighting the need to protect these networks from cyber-attacks. This paper will identify potential threats, vulnerabilities, and weaknesses of UAM environments, that could lead to system compromises and disruptions.

Cyber Security↗

System Administrator Training Item #25928

External and internal cyber-attacks pose an extreme risk to government, businesses and individuals. System attacks, resulting in compromised information are occurring more frequently and the threat to the Laboratory has never been higher. This training has been developed to help you better understand your role as a System Administrator and recognize your responsibilities within the Laboratory’s Information Security (Cyber) Program and has been revised to address newly implemented ACD 470.6 restrictions for mobile devices in secure areas.

97 MATHEMATICS AND COMPUTING↗

Understanding How Organizations Handle Cybersecurity

If there is anything we can learn from the media, it is the frequency and severity of cyber-attacks is increasing and there are not enough qualified people to combat the risk organizations are facing. Current estimates say there are 3.5 million available cybersecurity related jobs globally and there has been a 350% growth in cybersecurity jobs since 2013 (Group, 2020). The Idaho Cyber Research Project (ICRP) is focused on finding an implementing solution to the problems in the workforce development pipeline. Our team consists of Cohort 2 of the ICRP, we are tasked with solving issues faced by organizations hiring new cyber personnel. To provide solutions to these issues we focused our research on four components of workforce availability and competency: resume and transcript analysis, apprenticeships, cyber incident response plan development, and adversarial mindset training. From this research we have produced the following focus areas and subsequent steps for each component of workforce capability: transcript and knowledge skills abilities (KSA) focused analysis, cybersecurity apprenticeships programs, the value of an adversarial mindset, and a guide to setting up cyber incident response plans for underprepared organizations. These solutions can be further developed and implemented to reduce the gap in workforce demand and talent.

97 MATHEMATICS AND COMPUTING↗

NASA’s Secured Airspace for Urban Air Mobility (UAM)

The Urban Air Mobility (UAM) architecture is leveraged from the Unmanned Traffic Management (UTM) concept of operations. Within the UAM environment, UAM operators work collaboratively to manage aerial vehicles in the urban environment. Providers of Services for UAM (PSU), UAM operators, and Supplemental Data Service Providers (SDSP) provide services to support flight operations within that environment. As a recognized need, various views of UAM flight information are provided to the public and public safety entities. To accomplish this, among other goals, the Federal Aviation Administration (FAA) can coordinate flight information between the FAA controlled National Airspace System (NAS) and the UAM environments through the FAA-Industry Data Exchange Protocol (FIDXP). This concept of UAM proposes to develop short-range, point-to-point transportation systems in metropolitan areas using vertical take-off and landing (VTOL) or short take-off and landing (STOL) aircraft to overcome increasing surface congestion. To garner the support of UAM and to realize its potential, an assurance of cybersecurity is critical for public acceptance. Understanding the various components communicating with one-another cybersecurity, like in other industries, has come to the forefront highlighting the need to protect these networks and systems from cyberattacks. With the planned growth and reach of UAM systems, it’s clear that the associated data exchange and service interactions will be at risk due to numerous types of cybersecurity attacks. Consequently, as these threats evolve, the UAM cybersecurity capabilities must adapt to these changes as well. While learning is always the goal, the overall intent of this workshop is to make recommendations on the following: (1) how future UAM environments can be protected against cyber-attacks, and (2) what mechanisms should be put in place to detect attacks against UAM environments.

UAM↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Cyber Security for the Spaceport Command and Control System: Vulnerability Management and Compliance Analysis

With the rapid development of the Internet, the number of malicious threats to organizations is continually increasing. In June of 2015, the United States Office of Personnel Management (OPM) had a data breach resulting in the compromise of millions of government employee records. The National Aeronautics and Space Administration (NASA) is not exempt from these attacks. Cyber security is becoming a critical facet to the discussion of moving forward with projects. The Spaceport Command and Control System (SCCS) project at the Kennedy Space Center (KSC) aims to develop the launch control system for the next generation launch vehicle in the coming decades. There are many ways to increase the security of the network it uses, from vulnerability management to ensuring operating system images are compliant with securely configured baselines recommended by the United States Government.

Cyber Security↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

PUF-Based Two-Factor Authentication Protocol for Securing the Power Grid Against Insider Threat

Recent advances in smart grid technologies have enabled additional distributed control paradigms that allow more efficient and reliable operation. However, this creates new security concerns for the grid, such as attackers using spoofed grid control devices to generate false measurements. This paper introduces a two-factor authentication protocol leveraging standard public-key cryptography as one authentication factor and a hardware-based fingerprint, known as a Physical Unclonable Function, as a second authentication factor. This protocol incurs a small overhead and prevents cyber-attacks even when an adversary is able to compromise the cryptographic keys stored in the non-volatile memory of an intelligent control device.

42 ENGINEERING↗

SCEPTRE: A Cyber-Physical Emulation Capability

Cyber-physical systems form a critical but vulnerable backbone to US critical infrastructure. Recent high-profile cyber-attacks have shown the need for increased assessment and hardening of these systems. However, such assessments and investigations into advanced technologies to harden these systems is difficult due to their operational nature. Instead, modeling of these systems is heavily leveraged. Investigation into these complex systems and their potential cascading failures requires comprehensive modeling of both the cyber and physical components of the system. This paper introduces SCEPTRE, an emulation capability to address this need.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS): A Probabilistic Approach

In this project, we employ a layered protection strategy incorporating advanced optimization and detection techniques using a probabilistic approach. The probabilistic approach is not only applied when detecting cyber attacks, but also incorporated in control strategies, which greatly increases the attacking difficulties. Hackers need to understand both probabilistic detection algorithms and uncertainty modeling methods in control in order to execute any effective attacks. The end-to-end solutions enable us to provide Building Intelligence with Layered Defense using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cyber Physical Protection for Natural Gas Compression

The secure transport of natural gas through North American pipelines is vital for both home and industrial purposes. GE in collaboration with Baker Hughes and Idaho National Laboratory, completed a US Department of Energy grant program to develop a new cyber-physical protection system that monitors the large compressor stations used to boost pressure and maintain proper gas flow. Algorithms were developed to detect the presence of a cyber-attack that impacts the compressor station physical processes, locate the critical functions being manipulated, and potentially neutralize the attack allowing continued operations. The technology was successfully demonstrated at an operating compressor facility located in New York state.

03 NATURAL GAS↗

Comparison of Socio-Technical Threat Models

Given the adoption of emerging technologies and the increasing complexity of managing such systems with a lifecycle much shorter than that of critical infrastructure systems, there is a practical need to be able to analyze sociotechnical dependencies and their associated evolving risks. Threat models based on social influence techniques can be used to implement adversarial tactics analogous to the cyber kill chain and attested to within the MITRE ATT&CK for ICS framework including Initial Access, Persistence, Collection, and Impact. Furthermore, as with cyber disruptions, the impact of social influence threat models can have an asymmetric impact that is not spatially-localized. Finally, unlike cyber attacks with a reasonably short duration (ransomware takes days to months), social influence based attacks have the potential to persist for much longer as they are based on long-term strategic infrastructure investments within the private sector. Given the increased importance of electric vehicle charging stations as a long-term, strategic infrastructure investment within the Energy and Transportation Sectors, we provide initial results that compare the impact of a Loss of Availability (T0826) realized through cyber and social influence based threat models. The analysis employs techniques from automated reasoning and measures of network complexity to understand evolving dominance of EV payment and charging networks within geographic region of interest. Within this context, we compare the impact of a loss of availability due to ransomware versus that of loss of support due to a merger and acquisition. Results across several different metro areas will be provided.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Discovery of False Data Injection Attacks on Power Grid Frequency Controllers with Reinforcement Learning [Poster]

While inverter-based DER (distributed energy resources) are instrumental to integrating renewable energy into the power grid, they reduce the grid's mechanical inertia, thereby increasing the risk of frequency instabilities. To compensate for frequency instability risks, the grid must also undergo a transformation to include digital technologies that allow for two-way communication between the utility and customers. The current and future state of the power grid allows for building a cleaner energy landscape. However, the grid may also become vulnerable to novel cyber threats. To preemptively protect the power grid against elaborate cyber-attacks, we propose to discover potential threats via reinforcement learning. In this work, the focus is on studying false data injection attacks that target the control logic of frequency controllers. We show that a reinforcement learning agent can successfully discover how to best inject false data into linear droop controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering-In Cybersecurity

Cyber-Informed Engineering is a framework which allows engineers to build resiliency to the impacts of cyber attack into engineered systems starting in the early design phases. This article introduces the framework and provides a description of some of its principles and resources for learning more.

42 ENGINEERING↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗