Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “customization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

NASA Glenn Propulsion Systems Laboratory Customer Guide

This guide describes the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center (GRC) and was written to help customers utilizing the facility understand all the components of conducting a test program within the facility. The PSL complex supports two large engine test cells that simulate altitude flight conditions for a wide range of research and experimental tests. The test cells operate at altitudes up to 90,000 ft and speeds from subsonic to above supersonic. The way the facility sets test points at the engine or test article inlet, such as pressure, temperature, and Mach number is discussed. Support systems such as the heated and cooled combustion air system, the altitude exhaust system, the hydraulic system, the nitrogen, oxygen, and hydrogen systems, hydrogen burners, the engine exhaust gas-sampling system, and single- and multiple-axis thrust stands are addressed. Facility safety procedures, pre-test requirements, test operation standards are also stated in later sections. Past PSL tests and other capabilities are also discussed.

PSL Customer Guide↗

Understand the Costs of an Energy or Water Outage with the Customer Damage Function Calculator

The Customer Damage Function (CDF) Calculator is a free, publicly available web tool that helps users estimate the costs incurred at their site due to an electric grid or water service outage. Developed by the National Renewable Energy Laboratory (NREL) with support from the Federal Energy Management Program (FEMP), the tool is designed to help federal facility owners, building energy managers, and resilience planners understand and quantify the value of resilience to justify investments that would prevent or lessen the impact of a disruption.

CDF Calculator↗

A custom 3D printed paddlewheel improves growth in flat panel photobioreactor

One of the main challenges with using flat panel photobioreactors for algal growth is uneven mixing and settling of cells in corners, especially when bubbling is the only method used for mixing. Here, in order to improve mixing in our flat panel reactor, we designed a custom paddlewheel. Paddlewheels are frequently used in outdoor algae raceway ponds to improve mixing and we are taking advantage of the same principle for mixing in the reactor. The paddlewheel is easily integrated into our PSI FMT150 1‐L flat panel photobioreactor and is printed on a 3D printer using high temperature poly lactic acid (HT‐PLA). With the inclusion of an annealing step, the paddlewheel is autoclavable. Addition of the paddlewheel in the reactor minimized cell settling and improved algal growth, as evidenced by a nearly 40% increase in oxygen production rates. Nutrient dispersion and utilization in the culture was also improved as evidenced by a corresponding 38% decrease in CO 2 concentration. The paddlewheel device presented here is a cost‐effective method for improving algal growth in a flat panel photobioreactor.

09 BIOMASS FUELS↗

Custom 3D Printable Silicones with Tunable Stiffness

Silicone elastomers have broad versatility within a variety of potential advanced materials applications, such as soft robotics, biomedical devices, and metamaterials. Furthermore, a series of custom 3D printable silicone inks with tunable stiffness is developed, formulated, and characterized. The silicone inks exhibit excellent rheological behavior for 3D printing, as observed from the printing of porous structures with controlled architectures. Here, the capability to tune the stiffness of printable silicone materials via careful control over the chemistry, network formation, and crosslink density of the ink formulations in order to overcome the challenging interplay between ink development, post-processing, material properties, and performance is demonstrated.

36 MATERIALS SCIENCE↗

Custom-Made Endograft for Endovascular Repair of Thoraco-Abdominal Aneurysm and Type B Dissection: Single-Centre Experience

AimsTo report a series of patients treated with the Jotec custom-made endograft for thoraco-abdominal aneurysms and dissections and identify predictive factors for re-intervention.MethodsWe retrospectively analysed 49 patients unsuitable for surgery, treated between 2011 and 2017 (71.3 ± 9.5 years; 15 females). Indications included Crawford type 4 aneurysm in 25 patients, type 3 in 13, type 2 in 4, type 1 in 2 and chronic aneurysmal dilatation of the false lumen following dissection in 5 cases. Mean aneurysm diameter was 58.7 ± 8.4 mm. The study aims were to assess procedural success, complications rate, mortality and long-term follow-up. We also analysed factors that predicted the need for re-intervention.ResultsThe endograft was successfully deployed in all patients, catheterization of the fenestration and/or branches was achieved in 152/156 (97.4%) vessels. Early complications occurred in 10 patients (3 paraplegia, 3 haemorrhages, pancreatitis, aortic rupture, iliac artery rupture, 2 strokes). Thirty-day mortality was 10.2% and 180-day mortality 14.3%; two non procedure related deaths occurred. Mean follow-up was 23.6 ± 29.9 months [range 1–80]. No patients needed surgical explantation or developed significant renal impairment. Endoleak rate was 34.6% and re-intervention rate 9.7%. The aneurysm sac reduced or was stable in 36/49, and enlarged in 9/49 patients prompting re-intervention. Primary, primary-assisted and secondary patency of fenestrations/branches at 80 months was 90, 96 and 100%. Re-intervention was required more frequently in braches than in fenestrations, most commonly the external type branches.ConclusionsThe results of the Jotec endograft are comparable to other devices, with acceptable complication and re-intervention rates. Fenestration and inner-branch should be preferred due to lower re-intervention rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Customized MgB{sub 2} Superconducting Wire Toward Practical Applications at Sam Dong in Korea

MgB{sub 2} superconducting wire from Sam Dong Co., Ltd. in Korea is suitable for various applications, including medical resonance imaging, fault current limiters, power cables, and transformers. So far, issues related to the wire production cost, current-carrying capacity, and conductor length (kilometers) are very important for further commercialization. Since 2014, our intensive research efforts have led to notable progress. Herein, we summarize and discuss our advanced research for achieving high-performance, scalable, and cost-effective MgB{sub 2} wires at Sam Dong. Based on our accumulated technical know-how, we will continue to fabricate more competitive and efficient MgB{sub 2} superconducting wires that will be suitable for the customer’s purposes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interactive web mapping tools and custom subsurface cross-sections for interdisciplinary geologic investigation

Using Python-based geospatial analytics, open-source web mapping technologies, geophysical data models, and subsurface stratigraphy models from the Regional Geology Geologic Framework Model database assembled by Los Alamos National Laboratory, we developed a suite of web-based geologic investigation tools to identify and understand subsurface structures and geophysical properties concerning salt and shale formations within the contiguous United States. Coupled with a web map interface, these tools allow for the interactive visualization of various geologic data and demonstrate the ability to quickly generate custom subsurface cross-sections, borehole charts, and diagrams for azimuthal orientation data. These capabilities were developed for stakeholder and researcher use to facilitate informed decision making for spent nuclear waste disposition. However, these capabilities provide a flexible model for a variety of subsurface investigation needs, and we have demonstrated this flexibility by adapting these tools to meet visualization needs for various subsurface models within a web-based platform.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A high-performance organic cathode customized for sulfide-based all-solid-state batteries

All-solid-state batteries (ASSBs) have become increasingly attractive recently due to their better safety and prospective long-term stability compared with conventional liquid batteries. However, obtaining a sustainable cathode candidate to match the solid electrolyte with regards to operating potential, chemical compatibility, and mechanical property is still an open challenge. In this work, the chemical incompatibility of quinone-based active materials and sulfide-based electrolyte were unveiled for the first time through a heteroconjugate addition reaction mechanism. To develop a quinone cathode customized for sulfide-based ASSBs, poly-(anthraquinonyl sulfide)-graphene (PAQS-G) nanocomposite was reported. The stable polymer framework of PAQS can protect the quinone redox center by preventing nucleophilic attack from sulfide-based solid electrolytes. The graphene additives can ameliorate redox kinetics and improve active material utilization. The PAQS-G cathode exhibited a specific capacity of ~178 mAh g -1 and a high material utilization of ~79%. Excellent cycling stability was achieved with 94 % capacity after 200 cycles in lithium batteries and 95.5 % capacity after 300 cycles in sodium batteries at 0.1C rate, respectively. A promising potential for energy storage applications was demonstrated.

25 ENERGY STORAGE↗

Customized Dose Prescription for Permanent Prostate Brachytherapy: Insights From a Multicenter Analysis of Dosimetry Outcomes

Purpose: To investigate the biochemical control rate in patients undergoing permanent prostate brachytherapy as a function of the biologically effective dose (BED) and risk group. Methods and Materials: Six centers provided data on 3,928 permanent brachytherapy patients with postimplant dosimetry results. The mean prostate-specific antigen level was 8.9 ng/mL. {sup 125}I was used in 2,293 (58%), {sup 103}Pd in 1,635, and supplemental external beam radiotherapy in 882 (22.5%) patients. The patients were stratified into low- (n = 2,188), intermediate- (n = 1,188), and high- (n = 552) risk groups and into three BED groups of < 140 Gy (n = 524), 140-200 Gy (n = 2284), and >200 Gy (n = 1,115). Freedom from biochemical disease progression (biochemical freedom from failure [bFFF]) was determined using the American Society for Therapeutic Radiology Oncology and Phoenix definitions and calculated using the Kaplan-Meier method, with factors compared using the log-rank test. Results: The 10-year prostate-specific antigen bFFF rate for the American Society for Therapeutic Radiology Oncology and Phoenix definitions was 79.2% and 70%, respectively. The corresponding bFFF rates for the low-, intermediate-, and high-risk groups was 84.1% and 78.1%, 76.8% and 63.6%, and 64.4% and 58.2%, respectively (p < 0.0001). The corresponding bFFF rate for the three BED groups was 56.1% and 41.4%, 80% and 77.9%, and 91.1% and 82.9% (p < 0.0001). The corresponding bFFF rate for the low-risk patients by dose group was 69.8% and 49.8%, 86% and 85.2%, and 88.1% and 88.3% for the low-, intermediate, and high-dose group, respectively (p <0.0001). The corresponding bFFF rate for the intermediate-risk patients by dose group was 52.9% and 23.1%, 74.1% and 77.7%, and 94.3% and 88.8% for the low-, intermediate-, and high-dose group, respectively (p < 0.0001). The corresponding bFFF rate for high-risk patients by dose group was 19.2% and 41.7%, 61.8% and 53.2%, and 90% and 69.6% for the low-, intermediate-, and high-dose group, respectively (p < 0.0001). Conclusions: These data suggest that permanent brachytherapy dose prescriptions can be customized to risk status. In low-risk patients, achieving a BED of {>=}140 Gy might be adequate for prostate-specific antigen control. However, high-risk disease might require a BED dose of {>=}200 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Customized Computed Tomography-Based Boost Volumes in Breast-Conserving Therapy: Use of Three-Dimensional Histologic Information for Clinical Target Volume Margins

Purpose: To determine the difference in size between computed tomography (CT)-based irradiated boost volumes and simulator-based irradiated volumes in patients treated with breast-conserving therapy and to analyze whether the use of anisotropic three-dimensional clinical target volume (CTV) margins using the histologically determined free resection margins allows for a significant reduction of the CT-based boost volumes. Patients and Methods: The CT data from 49 patients were used to delineate a planning target volume (PTV) with isotropic CTV margins and to delineate a PTV{sub sim} that mimicked the PTV as delineated in the era of conventional simulation. For 17 patients, a PTV with anisotropic CTV margins was defined by applying customized three-dimensional CTV margins, according to the free excision margins in six directions. Boost treatment plans consisted of conformal portals for the CT-based PTVs and rectangular fields for the PTV{sub sim}. Results: The irradiated volume (volume receiving >=95% of the prescribed dose [V{sub 95}]) for the PTV with isotropic CTV margins was 1.6 times greater than that for the PTV{sub sim}: 228 cm{sup 3} vs. 147 cm{sup 3} (p < .001). For the 17 patients with a PTV with anisotropic CTV margins, the V{sub 95} was similar to the V{sub 95} for the PTV{sub sim} (190 cm{sup 3} vs. 162 cm{sup 3}; p = NS). The main determinant for the irradiated volume was the size of the excision cavity (p < .001), which was mainly related to the interval between surgery and the planning CT scan (p = .029). Conclusion: CT-based PTVs with isotropic margins for the CTV yield much greater irradiated volumes than fluoroscopically based PTVs. Applying individualized anisotropic CTV margins allowed for a significant reduction of the irradiated boost volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single Versus Customized Treatment Planning for Image-guided High-Dose-Rate Brachytherapy for Cervical Cancer: Dosimetric Comparison and Predicting Factor for Organs at Risk Overdose With Single Plan Approach

Purpose: To compare the dose distribution between customized planning (CP) and adopting a single plan (SP) in multifractionated high-dose-rate brachytherapy and to establish predictors for the necessity of CP in a given patient. Methods and Materials: A total of 50 computed tomography-based plans for 10 patients were evaluated. Each patient had received 6 Gy for five fractions. The clinical target volume and organs at risk (i.e., rectum, bladder, sigmoid, and small bowel) were delineated on each computed tomography scan. For the SP approach, the same dwell position and time was used for all fractions. For the CP approach, the dwell position and time were reoptimized for each fraction. Applicator position variation was determined by measuring the distance between the posterior bladder wall and the tandem at the level of the vaginal fornices. Results: The organs at risk D{sub 2cc} (dose to 2 cc volume) was increased with the SP approach. The dose variation was statistically similar between the tandem and ring and tandem and ovoid groups. The bladder D{sub 2cc} dose was 81.95-105.42 Gy{sub 2} for CP and 82.11-122.49 Gy{sub 2} for SP. In 5 of the 10 patients, the bladder would have been significantly overdosed with the SP approach. The variation of the posterior bladder wall distance from that in the first fraction was correlated with the increase in the bladder D{sub 2cc} (SP/CP), with a correlation coefficient of -0.59. Conclusion: Our results support the use of CP instead of the SP approach to help avoid a significant overdose to the bladder. This is especially true for a decrease in the posterior wall distance of {>=}0.5 cm compared with that in the first fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Quasi-Randomized Comparison of Intraoperatively Built Custom-Linked Seeds Versus Loose Seeds for Prostate Brachytherapy

Purpose: To compare dosimetric parameters, seed migration rates, operation times, and acute toxicities of intraoperatively built custom-linked (IBCL) seeds with those of loose seeds for prostate brachytherapy. Methods and Materials: Participants were 140 patients with low or intermediate prostate cancer prospectively allocated to an IBCL seed group (n=74) or a loose seed group (n=66), using quasirandomization (allocated by week of the month). All patients underwent prostate brachytherapy using an interactive plan technique. Computed tomography and plain radiography were performed the next day and 1 month after brachytherapy. The primary endpoint was detection of a 5% difference in dose to 90% of prostate volume on postimplant computed tomography 1 month after treatment. Seed migration was defined as a seed position >1 cm from the cluster of other seeds on radiography. A seed dropped into the seminal vesicle was also defined as a migrated seed. Results: Dosimetric parameters including the primary endpoint did not differ significantly between groups, but seed migration rate was significantly lower in the IBCL seed group (0%) than in the loose seed group (55%; P<.001). Mean operation time was slightly but significantly longer in the IBCL seed group (57 min) than in the loose seed group (50 min; P<.001). No significant differences in acute toxicities were seen between groups (median follow-up, 9 months). Conclusions: This prospective quasirandomized control trial showed no dosimetric differences between IBCL seed and loose seed groups. However, a strong trend toward decreased postimplant seed migration was shown in the IBCL seed group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Custom-designed heat treatment simultaneously resolves multiple challenges facing 3D-printed single-crystal superalloys

Single-crystal Ni-based superalloys are currently the material of choice for turbine blade applications, especially with the emerging additive manufacturing (AM) that facilitates the manufacture/repair of these single crystals. This promising AM route, however, comes with a dilemma: in the fusion and heat affected zones after e-beam or laser induced melting, one needs a solutionizing annealing to relieve the residual stresses and homogenize the chemical/microstructure. The super-solvus solutionizing temperature is usually adopted from the protocol for the cast superalloys, which almost always causes recrystallization and stray grain growth, resulting in a polycrystalline microstructure and degrading the high-temperature mechanical performance. Here, in this paper, we demonstrate a custom-designed post-printing heat treatment to replace the conventional super-solvus one. The recovery and relatively low temperature diminish the driving force for recrystallization and the movement of stray grain boundaries, without suffocating the chemical/microstructural homogenization thanks to the narrow dendrite width and short element segregation distance. The optimal duration of the heat treatment is proposed to achieve atomic-diffusion mediated chemical homogenization while limiting γ'-particle coarsening in the interdendritic regions. Our strategy makes it practically feasible to resolve several bottleneck problems with one processing/treatment, removing a seemingly formidable obstacle to effective additive manufacturing of superalloy single crystal products.

36 MATERIALS SCIENCE↗

A multistep enrichment process with custom growth medium improves resuscitation of chlorine-stressed coliforms from secondary sewage effluents

Resuscitation and detection of stressed coliforms in treated water samples is needed to assess and prevent health effects from adverse exposure. Herein, we developed a custom growth media that improved total coliform resuscitation from chlorine-stressed samples from secondary effluent to see if detection time could be reduced from 18 to 8 hours.

59 BASIC BIOLOGICAL SCIENCES↗

Synchrotron Infrared Confocal Microspectroscopic Spatial Resolution or a Customized Synchrotron/focal Plane Array System Enhances Chemical Imaging of Biological Tissue or Cells

Spectroscopy and spatially resolved chemical imaging of biological materials using an infrared microscope is greatly enhanced with confocal image plane masking to 5-6 {mu} with a third generation microspectrometer and illumination with a synchrotron radiation source compared to globar illuminated and array detection or singly masked system. Steps toward this instrumental achievement are illustrated with spectra and images of biological tissue sections, including single cells, brain, aorta, and grain specimens. A recent, customized synchrotron infrared microspectrometer installation enables focal plane array detection to achieve both rapid and high definition chemical imaging. Localization of the ester carbonyl population in single modified starch granules was used to provide direct comparison of the two advanced imaging capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗