Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Integrated path planning and control through proximal policy optimization for a marine current turbine

This paper presents an integrated path planning and tracking control framework for a marine current turbine (MCT), where the MCT is treated as an energy-harvesting autonomous underwater vehicle (AUV). Considering the ocean (space of action) is continuous, the proposed framework employs two modules to address path planning and path tracking enabled by the proximal policy optimization (PPO) algorithm, which is a policy gradient deep reinforcement learning (RL) method. Further, to enable fully autonomous operation in a stochastic oceanic environment, the proposed path planning seeks a primary objective of maximizing the harvested energy; then, the path tracking module is designed to minimize the tracking error and avoid collisions with static and dynamic obstacles. Using field-collected acoustic Doppler current profiler (ADCP) data, the performance of the proposed framework is evaluated. Comparative studies with baseline algorithms in three different scenarios of path planning, path tracking without an obstacle, and path tracking with collision avoidance verify the effectiveness of our proposed approach.

16 TIDAL AND WAVE POWER↗

Synchronized Waveforms – A Frontier of Data-Based Power System and Apparatus Monitoring, Protection, and Control

Voltage and current waveforms contain the most authentic and granular information on the behaviors of power systems. In recent years, it has become possible to synchronize waveform data measured from different locations. Thus large-scale coordinated analyses of multiple waveforms over a wide area are within our reach. This development could unleash a set of new concepts, strategies, and tools for monitoring, protecting, and controlling power systems and apparatuses. This paper presents an in-depth review and analysis of the advancements in synchronized waveform data, including measurement devices, data characteristics, use cases, and comparisons with synchrophasor data. Based on the findings, five strategies are proposed to discover and develop synchronized waveform based applications over multiple application areas. The paper also presents three complementary measurement platforms and two data screening algorithms for application implementation. It further discusses committee activities and standard developments useful to explore the full potential of the data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Open Building Control

Best practice control sequences are often not implemented correctly, or are not implemented at all, in large commercial buildings. This typically leads to 10-30 percent energy waste, along with reduced occupant productivity and unnecessary equipment wear. The current process of designing and implementing such control sequences is a manual process that starts with designers who often don’t have adequate training, then requires controls programmers to interpret and program a verbose written sequence. This process has been shown to fail to deliver high performance control sequences at scale. The Open Building Control project digitizes the current control delivery process. The project is developing tools for system designers to select control sequences, assess their energy performance and load flexibility potential using whole building simulation, specify the sequence for implementation using machine-to-machine translation by a control provider and formally testing the as-installed sequences by a commissioning agent. The project developed tools for each stage of this delivery process. The key innovation of the project is the development of the Control Description Language, a language that allows such a digitized control delivery process with end-to-end verification. Libraries of control sequences have been implemented using the Control Description Language, and their performance has been demonstrated using whole building energy simulation. An automated translation of such sequences to a commercial control product line has been conducted using a prototype translator. Tools for formal verification of as-installed control sequences relative to their specification have been developed and demonstrated. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) started the process of forming a committee to make this language an ASHRAE/ANSI Standard. This new standard will complement existing and emerging ASHRAE standards for building communication and semantic modeling by providing a standard for expressing the control logic - the actual brain of the building. We expect this language and the process it enables to be an important contribution to the deployment of high performance building control sequences at scale because it allows taming the complexity of the control delivery process, which is continually increasing due to the need for higher performance and increased load flexibility to meet goals for net zero energy and increased renewable integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observation of light-driven band structure via multiband high-harmonic spectroscopy

Intense light–matter interactions have revolutionized our ability to probe and manipulate quantum systems at sub-femtosecond timescales, opening routes to the all-optical control of electronic currents in solids at petahertz rates. Such control typically requires electric-field amplitudes in the range of almost volts per angstrom, when the voltage drop across a lattice site becomes comparable to the characteristic bandgap energies. In this regime, intense light–matter interaction induces notable modifications to the electronic and optical properties, dramatically modifying the crystal band structure. Yet, identifying and characterizing such modifications remain an outstanding problem. As the oscillating electric field changes within the driving field’s cycle, does the band structure follow and how can it be defined? Here we address this fundamental question, proposing all-optical spectroscopy to probe the laser-induced closing of the bandgap between adjacent conduction bands. Our work reveals the link between nonlinear light–matter interactions in strongly driven crystals and the sub-cycle modifications in their effective band structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Modeling of RMS Current in CSI Filter Capacitor and Minimum Conduction Loss Operation of CSI-Fed PMSM Drives for Traction Applications

This paper presents a new minimum conduction loss (MCL) torque control algorithm for current source inverter- (CSI-) fed permanent-magnet synchronous machine drives that improves the overall machine drive efficiency by minimizing the combined conduction losses in the inverter and machine at each operating point. First, analytical models of conduction losses in CSI-fed motor drives are presented, and a closed-form expression for optimal d-axis stator current to achieve MCL operation is derived. An expression for the rms current in both wye- and delta-connected CSI output capacitors is derived. A detailed simulation model that emulates the operation of a 100 kW SiC CSI-fed integrated machine drive (IMD) has been developed based on experimental results and finite element analysis. This simulation model is used to evaluate the proposed MCL control algorithm applied to a CSI-fed IMD system for a battery-electric vehicle traction drive, and the predicted total drive system loss with MCL control is compared to predicted losses with maximum-torque-per-ampere (MTPA) and minimum dc-link current (MDCC) control. Results show that MCL control can achieve loss reductions compared to the other two control algorithms over a wide range of operating conditions, with significant loss reductions >20% in the medium-speed regime.

42 ENGINEERING↗

Understanding the Capabilities and Limitations of the Controls and Operations of High Voltage Direct Current (HVdc) Converters in Interconnected Electric Power Systems

This project will seek to build a fundamental understanding, and capability, to model and simulate the controls and operations of high voltage direct current (HVdc) converter stations in an electromagnetic simulation environment. While HVdc stations have been operated in the United States for over 50 years, these are typically simple two terminal point-to-point systems. Recently multi-terminal systems have begun to be deployed. The challenge with these new multi-terminal systems is that they often use different control schemes on the different terminals. The interactions of existing and new controls, and the fact that HVdc systems are rates in the 1,000’s of MWs means that small control instabilities can have dramatic impacts to bulk power systems. Despite these challenges, the operational capabilities of HVdc make them an attractive option for the transfer of the large amounts of renewable electricity that will be necessary for decarbonization of the nation’s electrical infrastructure and other sectors.

42 ENGINEERING↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

Incremental rotary rolling mill and method

A rolling mill system for Incremental rotary shaping of an elongated workpiece is provided that includes first and second workpiece holders. A support frame has a track with the first and second workpiece holders being movably associated with the track, the workpiece holders and an associated workpiece being movable in unison along the track. A radial chuck is mounted to the frame that includes a plurality of jaws that are movable radially inwardly and outwardly. Each jaw has a tool mounted thereto that is rotatable about an axis of rotation, with the axis of rotation of each tool being oriented at a skew angle relative to the longitudinal axis of a workpiece. A source of electric current and an electrically conductive flow path are provided for flowing electrical current through a workpiece. A controller is provided that is configured to control the operation of each of the first motor, second motor and third motor, and to control the flow of current flowing through the tools to the workpiece.

Zeng, Qiang↗

Preliminary design of control rods in the single-fluid double-zone thorium molten salt reactor (SD-TMSR)

Recent studies on Molten Salt Reactors (MSRs) showed that the excess reactivity at the beginning of the operation is large for many fueling strategies and must be compensated by a reactivity control system. The current work introduces a reliable safety system based on control rods in addition to the online feed system reactivity control in the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR). Three different initial fissile loadings are considered: 233 U, reactor-grade Pu, and transuranic (TRU) elements as a startup fuel. We applied six different absorbing materials to investigate the main operational and safety parameters in the SD-TMSR: natural B 4 C, enriched B 4 C with 90% 10 B, HfB 2 , HfH 1.62 , Eu 2 O 3 , and Gd 2 O 3 . The present work focuses on control rod design, integral and differential control rod worth, shutdown margin, and shadowing effects at steady-state. We employed the SERPENT-2 Monte-Carlo code to calculate the reactivity worth and analyze the performance of the reactivity control system. We showed that 233 U and reactor-grade Pu startup cores maintain adequate shutdown margin with all considered absorbers. Finally, this report proposes a design of control rod clusters that compensate the excess reactivity of the SD-TMSR loaded with different initial fissile material.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetic Energy Dissipation and γ-Ray Emission in Energetic Pulsars

Abstract Some of the most energetic pulsars exhibit rotation-modulated γ -ray emission in the 0.1–100 GeV band. The luminosity of this emission is typically 0.1%–10% of the pulsar spin-down power ( γ -ray efficiency), implying that a significant fraction of the available electromagnetic energy is dissipated in the magnetosphere and reradiated as high-energy photons. To investigate this phenomenon we model a pulsar magnetosphere using 3D particle-in-cell simulations with strong synchrotron cooling. We particularly focus on the dynamics of the equatorial current sheet where magnetic reconnection and energy dissipation take place. Our simulations demonstrate that a fraction of the spin-down power dissipated in the magnetospheric current sheet is controlled by the rate of magnetic reconnection at microphysical plasma scales and only depends on the pulsar inclination angle. We demonstrate that the maximum energy and the distribution function of accelerated pairs is controlled by the available magnetic energy per particle near the current sheet, the magnetization parameter. The shape and the extent of the plasma distribution is imprinted in the observed synchrotron emission, in particular, in the peak and the cutoff of the observed spectrum. We study how the strength of synchrotron cooling affects the observed variety of spectral shapes. Our conclusions naturally explain why pulsars with higher spin-down power have wider spectral shapes and, as a result, lower γ -ray efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

Planar Hall Driven Torque in a Ferromagnet/Nonmagnet/Ferromagnet System

An important goal of spintronics is to covert a charge current into a spin current with a controlled spin polarization that can exert torques on an adjacent magnetic layer. Here we demonstrate such torques in a two ferromagnet system. A CoNi multilayer is used as a spin current source in a sample with structure CoNi/Au/CoFeB. Spin torque ferromagnetic resonance is used to measure the torque on the CoFeB layer. The response as a function of the applied field angle and current is consistent with the symmetry expected for a torque produced by the planar Hall effect originating in CoNi. We find the strength of this effect to be comparable to that of the spin Hall effect in platinum, indicating that the planar Hall effect holds potential as a spin current source with a controllable polarization direction.

ferromagnetic resonance↗

CYVET: A Cyber-Physical Assurance Framework Based on a Semi-Supervised Vetting Approach

The project is designed to directly address the needs described in the Topic Area 4 (“Cybersecurity Verification and Validation”) of the CEDS’19 Research Call. The proposed CYVET system directly addresses the need to elevate the current industry capabilities to verify and validate OT cybersecurity and associated control system infrastructure. Currently, there is a significant gap in the energy sector’s capability in that regard during infrastructure improvement, equipment procurement, and compliance certification. CYVET provides that needed capability. CYVET is device and architecture agnostic and thus broadly applicable across the energy sector. The goal of this project is to develop and deliver a cybersecurity verification and validation framework testing capability to verify and validate OT equipment, software, and the underlying control system architecture. The primary project objectives are (i) Verification: the synthesis and reconciliation of standards and vendor supplied features, (ii) Validation: the generation, execution, and presentation of testing scripts of verified security features, and (3) Demonstration: apply the developed technology capabilities for verification and validation at a relevant end-user facility in the energy sector.

Lopez Jr, Juan↗

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC Link Voltage Balancing of the Active Front-End for the Extreme Fast Charging Stations

One of the most important challenges of the extreme fast charging (XFC) stations is to balance the DC link voltages of the active front-end (AFE). The multilevel cascaded H-bridge (CHB) converter is a great topology for the AFE applications due to the high power density, low total harmonic distortion (THD), and a low number of active and passive components. In this paper, a technique is proposed for balancing DC-link capacitor voltages of a three-phase CHB converter, when a phase shiftPWM modulation technique is used on all cells of the converter. To reach this goal, the redundant states of the CHB converters are used for generating different AC voltage levels by sorting the voltages of the converters. The proposed voltage balancing technique uses the principles that are employed for the DC link voltage balancing of the low-frequency modulation techniques to balance the DC link voltages of the CHB converter. As shown in this paper, the DC link voltages of the CHB converter can accurately be balanced very fast without using PI controllers, which are used in the conventional DC link voltage balancing techniques. A controller also is proposed which will be used to control the dq currents of the CHB converter. To verify the advantages of the proposed technique, the simulation results of the proposed technique will be carried out in a three-phase 7-cell CHB AFE.

Grid-tied converters, cascaded H-bridge, DC link v↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗