Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Progress update on cryogenic system for ARIEL E-linac at TRIUMF

TRIUMF is involved in a major upgrade. The Advanced Rare IsotopeE Laboratory (ARIEL) has become a fully funded project in July 2010. A 10 mA 50 MeV SRF electron linac (e-linac) operating CW at 1.3 GHz is the key component of this initiative. This machine will serve as a second independent photo-fission driver for Rare Isotope Beams (RIB) production at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. The cryogens delivery system requirements are driven by the electron accelerator cryomodule design [1, 2]. Since commencement of the project in 2010 the cryogenic system of e-linac has moved from the conceptual design phase into engineering design and procurement stage. The present document summarizes the progress in cryogenic system development and construction. Current status of e-linac cryogenic system including details of LN{sub 2} storage and delivery systems, and helium subatmospheric (SA) system is presented. The first phase of e-linac consisting of two cryomodules, cryogens storage, delivery, and distribution systems, and a 600 W class liquid helium cryoplant is scheduled for installation and commissioning by year 2014.

43 PARTICLE ACCELERATORS↗

Status of the ESS cryogenic system

The European Spallation Source (ESS) is a neutron science facility funded by a collaboration of 17 European countries currently under design and construction in Lund, Sweden. The centerpiece of ESS is a 2.5 GeV proton linac utilizing superconducting RF cavities operating at 2 K. In addition to cooling the SRF cavities, cryogenics is also used at ESS in the liquid hydrogen moderators surrounding the target. ESS also uses both liquid helium and liquid nitrogen in a number of the planned neutron instruments. There is also a significant cryogenic installation associated with the site acceptance testing of the ESS cryomodules. The ESS cryogenic system consists of 3 separate helium refrigeration/liquefaction plants supplying the accelerator, target moderators and instruments. An extensive cryogenic distribution system connects the accelerator cryoplant with the cryomodules. This paper describes the preliminary design of the ESS cryogenic system including the expected heat loads. Challenges associated with the required high reliability and turn-down capability will also be discussed. A unique feature of ESS is its commitment to sustainability and energy recovery. A conceptual design for recovering waste heat from the helium compressors for use in the Lund district heating system will also be described.

43 PARTICLE ACCELERATORS↗

Injection locking and coupling dynamics in superconducting nanowire-based cryogenic oscillators

Oscillators designed to function at cryogenic temperatures play a critical role in superconducting electronics and quantum computing by providing stable, low-noise signals with minimal energy loss. Here, in this work, we present a comprehensive numerical study of injection locking and mutual coupling dynamics in superconducting nanowire (ScNW)-based cryogenic oscillators. Using the design space of a standalone ScNW-based oscillator, we investigate two critical mechanisms that govern frequency synchronization and signal coordination in cryogenic computing architectures: (1) injection locking induced by an external AC signal with a frequency near the oscillator's natural frequency, and (2) the mutual coupling dynamics between two ScNW oscillators under varying coupling strengths. We identify key design parameters—such as shunt resistance, nanowire inductance, and coupling strength—that govern the locking range. Additionally, we examine how the amplitude of the injected signal affects the amplitude of the locked oscillation, offering valuable insights for power-aware oscillator synchronization. Furthermore, we analyze mutual synchronization between coupled ScNW oscillators using capacitive and resistive coupling elements. Our results reveal that the phase difference between oscillators can be controlled by tuning the coupling strength, enabling programmable phase-encoded information processing. These findings could enable building ScNW-based oscillatory neural networks, synchronized cryogenic logic blocks, and on-chip cryogenic resonator arrays.

Artificial neural networks↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Cryogen Safety Live #8876

Cryogenics (from the Greek word κρυος, meaning frost or icy cold) is the study of the effects and behavior of materials at very low temperature. This course is designed to provide trainees with an introduction to cryogen use, hazards associated with cryogen systems, cryogen safety components, and the requirements that govern the design and use of cryogen systems at Los Alamos National Laboratory (LANL). The knowledge you gain is intended to help you keep your workplace safe for you and your coworkers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

In this paper, we present a detailed procedure for the operation of continuous, micron-sized cryogenic cylindrical and planar liquid jets. When operated as described here, the jet exhibits high laminarity and stability for centimeters. Successful operation of a cryogenic liquid jet in the Rayleigh regime requires a basic understanding of fluid dynamics and thermodynamics at cryogenic temperatures. Theoretical calculations and typical empirical values are provided as a guide to design a comparable system. This report identifies the importance of both cleanliness during cryogenic source assembly and stability of the cryogenic source temperature once liquefied. The system can be used for high repetition rate laser-driven proton acceleration, with an envisioned application in proton therapy. Other applications include laboratory astrophysics, materials science, and next-generation particle accelerators.

42 ENGINEERING↗

Technology Maturation in Preparation for the Cryogenic Propellant Storage and Transfer (CPST) Technology Demonstration Mission (TDM)

In support of its goal to find an innovative path for human space exploration, NASA embarked on the Cryogenic Propellant Storage and Transfer (CPST) Project, a Technology Demonstration Mission (TDM) to test and validate key cryogenic capabilities and technologies required for future exploration elements, opening up the architecture for large in-space cryogenic propulsion stages and propellant depots. Recognizing that key Cryogenic Fluid Management (CFM) technologies anticipated for on-orbit (flight) demonstration would benefit from additional maturation to a readiness level appropriate for infusion into the design of the flight demonstration, the NASA Headquarters Space Technology Mission Directorate (STMD) authorized funding for a one-year technology maturation phase of the CPST project. The strategy, proposed by the CPST Project Manager, focused on maturation through modeling, concept studies, and ground tests of the storage and fluid transfer of CFM technology sub-elements and components that were lower than a Technology Readiness Level (TRL) of 5. A technology maturation plan (TMP) was subsequently approved which described: the CFM technologies selected for maturation, the ground testing approach to be used, quantified success criteria of the technologies, hardware and data deliverables, and a deliverable to provide an assessment of the technology readiness after completion of the test, study or modeling activity. The specific technologies selected were grouped into five major categories: thick multilayer insulation, tank applied active thermal control, cryogenic fluid transfer, propellant gauging, and analytical tool development. Based on the success of the technology maturation efforts, the CPST project was approved to proceed to flight system development.

propellants↗

The 26th Space Cryogenic Workshop: Overview, Description of Presentations, and List of Abstracts

This is a summary of the 2015 Space Cryogenics Workshop that was held in Phoenix, Arizona, June 24 to 26, 2015. The workshop was organized by David Plachta and Jason Hartwig of the Cryogenics and Fluid Systems Branch at NASA Glenn Research Center, and continued the tradition of bringing together specialists in the field of space cryogenics to discuss upcoming and potential space missions, and the development of technologies that support or-more often-are enabling for the science and exploration goals of the world's space agencies. The workshop consisted of two days of talks and poster sessions, and provided ample opportunity for more informal discussions that foster collaborations and cooperation in the space cryogenics community. Selected papers from the workshop are published in a special issue of Cryogenics, which is expected to be published by the end of 2015.

Numerical modeling↗

Analytical Study of a Cryogenic Thermal Control Coating

This study focuses on the analysis of a cryogenic thermal control coating designed to reflect most of the Sun’s irradiance while emitting long wavelength radiation, thus enabling propulsion systems to maintain cryogenic temperatures while in deep space. This “solar white” coating is composed of yttrium oxide (Y2O3) which has properties that are well-suited for cryogenic propellant storage applications. To conduct proof of concept and material development, many tests have been run at both NASA Kennedy Space Center (KSC) and Glenn Research Center (GRC) to demonstrate the performance of the coating in the cryogenic regime in both powder and ceramic forms. At GRC, the Deep Space Solar Simulator (DS3) was used to run thermal vacuum tests where the coating was exposed to a deep space environment (~10 K) with some tests conducted under the illumination of a solar lamp. Using the test data, a thermal model of the DS3 test setup was developed to correlate the test results to predict the optical properties of the coating. Once the optical properties were determined, an additional thermal model, based on previous work by R.C. Young quist et al., was developed to verify the performance of a theoretical lunar, cryogenic propellant depot. The latter thermal model also demonstrates the usage of the HLS-UG-001 Human Landing System Lunar Thermal Analysis Guidebook published to baseline Artemis-related lunar studies.

Cryogenic↗

A Summary of Recent SBIR and STTR Projects in Support of Cryogenic Fluid Management Modeling

Over the last five years, NASA has invested in development of sub-models to improve the current capabilities of Computational Fluid Dynamics (CFD) codes utilized for cryogenic fluid management (CFM) predictions. The goal is for the submodels to be modular so that they can easily be implemented into NASA’s CFD codes such as ANSYS Fluent, Siemens STAR-CCM+, and Streamline Numerics Loci-Stream. These technologies are being developed through Small Business Innovative Research (SBIR) and Small Business Technology Transfer (STTR) contracts under the CFM subtopic solicitation and funded by the CFM Portfolio Project. All contracts presented include cryogenic experiments to enable model validation. A sub-grid boiling model has been developed by Combustion Research and Flow Technology Inc. and Massachusetts Institute of Technology for cryogenic line chilldown predictions and has completed Phase III. A spray chill-and-fill model for cryogenic tankage is being developed by Combustion Research and Flow Technology Inc. and University of Connecticut and is currently in Phase II. Last, film condensation modeling to support cryogenic liquefaction was progressed through a Phase I contract with Combustion Research and Flow Technology Inc. and University of Connecticut. A summary of accomplishments for each contract is presented.

cryogenics↗

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting↗

Dispersion of cryogenic hydrogen through high-aspect ratio nozzles

Liquid hydrogen is increasingly being used as a delivery and storage medium for stations that provide compressed gaseous hydrogen for fuel cell electric vehicles. In efforts to provide scientific justification for separation distances for liquid hydrogen infrastructure in fire codes, the dispersion characteristics of cryogenic hydrogen jets (50–64 K) from high aspect ratio nozzles have been measured at 3 and 5 bar abs stagnation pressures. These nozzles are more characteristic of unintended leaks, which would be expected to be cracks, rather than conventional round nozzles. Spontaneous Raman scattering was used to measure the concentration and temperature field along the major and minor axes. Within the field of interrogation, the axis-switching phenomena was not observed, but rather a self-similar Gaussian-profile flow regime similar to room temperature or cryogenic hydrogen releases through round nozzles. The concentration decay rate and half-widths for the planar cryogenic jets were found to be nominally equivalent to that of round nozzle cryogenic hydrogen jets indicating a similar flammable envelope. The results from these experiments will be used to validate models for cryogenic hydrogen dispersion that will be used for simulations of alternative scenarios and quantitative risk assessment.

08 HYDROGEN↗

Effect of cryogenic temperatures and processing parameters on gradient-structure of a stainless steel treated by ultrasonic surface mechanical attrition treatment

Highlights: • Gradient microstructures made by SMAT are investigated for an austenitic 304 L steel. • Cryogenic shot peening reduces the surface roughness. • Cryogenic condition increases subsurface hardening by formation of additional martensite. • The maximum martensite fraction is always located at the subsurface. • Combination of parameters allow to tailor broad ranges of hardness and roughness. - Abstract: The beneficial effect of using cryogenic temperatures for the ultrasonic surface mechanical attrition treatment (SMAT) is depicted in the case of the 304 L austenitic stainless steel. The cryogenic temperatures induce an additional driving force for the formation of martensite at depth where the effect of shot peening tends to vanish, raising the subsurface hardness by 20 to 30%. The maximum amount of α′ martensite was always located within the subsurface. This is explained by different mechanisms operating at different stages during the SMAT process: (i) higher shear stresses at the subsurface due to the Hertzian contact stress, (ii) local heating due to the shot impacts and (iii) surface martensite destabilization when the microstructure enters the nanometric range. Consequently, the gradient structure formed by the SMAT superimposes different natures of gradients in terms of grain size and martensitic fraction. The steel being harder to deform at cryogenic temperatures, a significant decrease of the apparent surface roughness (down to 44%) is also obtained. An appropriate selection of processing parameters allows to tailor the surface towards a broad range of hardness and roughness values: 425 to 560 HV and 1.6 to 3.3 μm, respectively.

36 MATERIALS SCIENCE↗

Design progress of cryogenic hydrogen system for China Spallation Neutron Source

China Spallation Neutron Source (CSNS) is a large proton accelerator research facility with 100 kW beam power. Construction started in October 2011 and is expected to last 6.5 years. The cryogenic hydrogen circulation is cooled by a helium refrigerator with cooling capacity of 2200 W at 20 K and provides supercritical hydrogen to neutron moderating system. Important progresses of CSNS cryogenic system were concluded as follows. Firstly, process design of cryogenic system has been completed including helium refrigerator, hydrogen loop, gas distribution, and safety interlock. Secondly, an accumulator prototype was designed to mitigate pressure fluctuation caused by dynamic heat load from neutron moderation. Performance test of the accumulator has been carried out at room and liquid nitrogen temperature. Results show the accumulator with welding bellows regulates hydrogen pressure well. Parameters of key equipment have been identified. The contract for the helium refrigerator has been signed. Mechanical design of the hydrogen cold box has been completed, and the hydrogen pump, ortho-para hydrogen convertor, helium-hydrogen heat exchanger, hydrogen heater, and cryogenic valves are in procurement. Finally, Hydrogen safety interlock has been finished as well, including the logic of gas distribution, vacuum, hydrogen leakage and ventilation. Generally, design and construction of CSNS cryogenic system is conducted as expected.

43 PARTICLE ACCELERATORS↗

Non-cryogenic structure of a chloride pump provides crucial clues to temperature-dependent channel transport efficiency

Non-cryogenic protein structures determined at ambient temperature may disclose significant information about protein activity. Chloride-pumping rhodopsin (ClR) exhibits a trend to hyperactivity induced by a change in the photoreaction rate because of a gradual decrease in temperature. Here, to track the structural changes that explain the differences in CIR activity resulting from these temperature changes, we used serial femtosecond crystallography (SFX) with an X-ray free electron laser (XFEL) to determine the non-cryogenic structure of ClR at a resolution of 1.85 Å, and compared this structure with a cryogenic ClR structure obtained with synchrotron X-ray crystallography. The XFEL-derived ClR structure revealed that the all-trans retinal (ATR) region and positions of two coordinated chloride ions slightly differed from those of the synchrotron-derived structure. Moreover, the XFEL structure enabled identification of one additional water molecule forming a hydrogen bond network with a chloride ion. Analysis of the channel cavity and a difference distance matrix plot (DDMP) clearly revealed additional structural differences. B-factor information obtained from the non-cryogenic structure supported a motility change on the residual main and side chains as well as of chloride and water molecules because of temperature effects. Our results indicate that non-cryogenic structures and time-resolved XFEL experiments could contribute to a better understanding of the chloride-pumping mechanism of ClR and other ion pumps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Requirements and Capabilities for Fielding Cryogenic DT-Containing Fill-Tube Targets for Direct-Drive Experiments on OMEGA

Improving the performance of direct-drive cryogenic targets at the Omega Laser Facility requires the development of a new cryogenic system to (i) field non permeable targets with a fill tube, and (ii) provide a clean environment around the target. This capability is to demonstrate that imploding a scaled-down version of the direct-drive–ignition target for the National Ignition Facility (NIF) on the OMEGA laser will generate the hot-spot pressure that is needed for ignition; this will justify future cryogenic direct-drive experiments on the NIF. The paper describes the target, the cryogenic equipment that is being constructed to achieve this goal, and the proposed target delivery process. Thermal calculations, fill-tube–based target designs, and structural/vibrational analyses are provided to demonstrate the credibility of the design. This new design will include capabilities not available (or possible) with the existing OMEGA cryogenic system, with the emphasis being to preserve a pristinely clean environment around the target, and to provide upgraded diagnostics to characterize both the ice layer and the target’s surface. The conceptual design is complete and testing of prototypes and subcomponents is underway. The rationale and capabilities of the new design are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fermilab Cryogenic Test Facilities

Fermi National Accelerator Laboratory (Fermilab) has multiple cryogenic test facilities, undertaking testing of superconducting magnets, Superconducting Radio Frequency (SRF) cavities, SRF cryomodules and other helium cryogenic components. The test areas within Fermilab include: Meson Cryogenic Test facility (Meson), Industrial Building 1 (IB-1), Heavy Assembly Building/Illinois Accelerator Research Center (HAB/IARC), New Muon Lab, (NML) and the Cryomodule Test Facility (CMTF). Meson and HAB/IARC utilize repurposed Tevatron era reciprocating engine based cryogenic refrigerator systems, whereas CMTF and IB-1 utilize gas bearing turbine based coldboxes. Each of these test areas support the various Fermilab projects and collaborations including the Linear Coherent Light Source II (LCLS-II), Proton Improvement Plan II (PIP-II), High Luminosity Large Hadron Collider (HL-LHC), and Mu2e. This paper outlines the diverse and extensive cryogenic test capabilities within Fermilab.

43 PARTICLE ACCELERATORS↗

Thermodynamic Analyses of the LCLS-II Cryogenic Distribution System

The Linac Coherent Light Source (LCLS) at Stanford Linear Accelerator Center (SLAC) is in the process of being upgraded to a superconducting radio frequency (SRF) accelerator and renamed LCLS-II. This upgrade requires thirty-five 1.3 GHz SRF cryomodules (CM) and two 3.9 GHz CM. A cryogenic distribution system (CDS) is in development by Fermi National Accelerator Laboratory to interconnect the CM Linac with the cryogenic plant (CP). The CDS design utilizes cryogenic helium to support the CM operations with a high temperature thermal shield around 55 K, a low temperature thermal intercepts around 5 K, and a SRF cavity liquid helium supply and sub-atmospheric vapor return both around 2 K. Additionally the design must accommodate a Linac consisting of two parallel cryogenic strings, supported by two independent CP utilizing CDS components such as distribution boxes, transfer lines, feed caps and endcaps. In this paper, we describe the overall layout of the cryogenic distribution system and the major thermodynamic factors which influence the CDS design including heat loads, pressure drops, temperature profiles, and pressure relieving requirements. In addition the paper describes how the models are created to perform the analyses.

43 PARTICLE ACCELERATORS↗