Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Full-coverage film cooling: 3-dimensional measurements of turbulence structure and prediction of recovery region hydrodynamics

Hydrodynamic measurements were made with a triaxial hot-wire in the full-coverage region and the recovery region following an array of injection holes inclined downstream, at 30 degrees to the surface. The data were taken under isothermal conditions at ambient temperature and pressure for two blowing ratios: M = 0.9 and M = 0.4. Profiles of the three main velocity components and the six Reynolds stresses were obtained at several spanwise positions at each of the five locations down the test plate. A one-equation model of turbulence (using turbulent kinetic energy with an algebraic mixing length) was used in a two-dimensional computer program to predict the mean velocity and turbulent kinetic energy profiles in the recovery region. A new real-time hotwire scheme was developed to make measurements in the three-dimensional turbulent boundary layer over the full-coverage surface.

Yavuzkurt, S.↗

Full-coverage film cooling. I - Comparison of heat transfer data for three injection angles

Wind tunnel experiments were carried out at Stanford between 1971 and 1977 to study the heat transfer characteristics of full-coverage film cooled surfaces with three geometries; normal-, 30 deg slant-, and 30 deg x 45 deg compound-angled injection. A flat full-coverage section and downstream recovery section comprised the heat transfer system. The experimental objectives were to determine, for each geometry, the effects on surface heat flux of injection blowing ratio, injection temperature ratio, and upstream initial conditions. Spanwise-averaged Stanton numbers were measured for blowing ratios from 0 to 1.3, and for two values of injection temperature at each blowing ratio. The heat transfer coefficient was defined on the basis of a mainstream-to-wall temperature difference. Initial momentum and enthalpy thickness Reynolds numbers were varied from 500 to about 3000.

Crawford, M. E.↗

Full-coverage film cooling. II - Heat transfer data and numerical simulation

Experimental research into heat transfer from full-coverage film-cooled surfaces with three injection geometries was described in Part I. This part has two objectives. The first is to present a simple numerical procedure for simulation of heat transfer with full-coverage film cooling. The second objective is to present some of the Stanton number data that was used in Part I of the paper. The data chosen for presentation are the low-Reynolds number, heated-starting-length data for the three injection geometries with five-diameter hole spacing. Sample data sets with high blowing ratio and with ten-diameter hole spacing are also presented. The numerical procedure has been successfully applied to the Stanton number data sets.

Crawford, M. E.↗

Vortex generating flow passage design for increased film-cooling effectiveness and surface coverage

The fluid mechanics of the basic discrete hole film cooling process is described as an inclined jet in crossflow and a cusp shaped coolant flow channel contour that increases the efficiency of the film cooling process is hypothesized. The design concept requires the channel to generate a counter rotating vortex pair secondary flow within the jet stream by virture of flow passage geometry. The interaction of the vortex structures generated by both geometry and crossflow was examined in terms of film cooling effectiveness and surface coverage. Comparative data obtained with this vortex generating coolant passage showed up to factors of four increases in both effectiveness and surface coverage over that obtained with a standard round cross section flow passage. A streakline flow visualization technique was used to support the concept of the counter rotating vortex pair generating capability of the flow passage design.

Papell, S. S.↗

Structural coverage of functional testing

A FORTRAN program was instrumened to produce structural coverage measures. The structural coverage profiles of functionally generated acceptance tests and operational usage are used to examine two areas in software engineering: the examination of faults and the applicability of reliability models.

Ramsey, J.↗

Examining functional acceptance testing with structural coverage metrics

Functionally generated acceptance tests are examined using structural coverage metrics. A method of comparing acceptance tests and operational usage was generated. Acceptance tests are prepresentative of operational usage except for the mix of statement types. Structural coverage metrics may provide insight into software faults.

Ramsey, J.↗

Estimating vegetation coverage in St. Joseph Bay, Florida with an airborne multispectral scanner

A four-channel multispectral scanner (MSS) carried aboard an aircraft was used to collect data along several flight paths over St. Joseph Bay, FL. Various classifications of benthic features were defined from the results of ground-truth observations. The classes were statistically correlated with MSS channel signal intensity using multivariate methods. Application of the classification measures to the MSS data set allowed computer construction of a detailed map of benthic features of the bay. Various densities of segrasses, various bottom types, and algal coverage were distinguished from water of various depths. The areal vegetation coverage of St. Joseph Bay was not significantly different from the results of a survey conducted six years previously, suggesting that seagrasses are a very stable feature of the bay bottom.

Savastano, K. J.↗

SIR-B coverage

The planned coverage with the Shuttle Imaging Radar-B (SIR-B) is described in detail. A total of about 60-million square km of coverage will be acquired including 50 h of Tracking and Data Relay Satellite (TDRS) data and 8 h of optically recorded data. In general, data will be acquired directly through TDRS whenever possible; however, because of certain constraints imposed by having just one TDRS in orbit during the time of this mission, many digitally taped data takes will be required. (Each separate SIR-B observation is designed as a data take). Optical data takes will be taken only over sites that cannot be acquired either directly through TDRS or on a digital tape. It is important to note that, although a digital data take may be acquired at any time during the mission, it will be necessary to dump that data take through TDRS at some later time, or replace the tape onboard the Shuttle with another blank tape.

Source record↗

Some methods of estimating a coverage parameter

To demonstrate the high reliability of fault-tolerant computing systems, experimental testing can be performed by injecting faults into their hardware and observing the times needed to detect and isolate failed components and reconfigure the good components. Coverage, a parameter measuring continued system success, is the probability that recovery occurs before other, perhaps catastrophic, component failures occur. Methods of estimating coverage are given for the case of randomly selecting a subset of the pins or chips for testing. Pin-level samples of times to recovery are treated by the Type I censoring model often used in life testing.

Lee, L. D.↗

p(2 x 2) and c(2 x 2) coverages of Cl and F on Ni(100), a comparison with O and S on Ni(100)

The rigid lattice adsorbate vibrational frequency normal to the surface, omega(e,r) and height above the surface, R(transverse), are computed for p(2 x 2) (0.25 ML) and c(2 x 2) (0.5 ML) coverages of Cl and F. These calculations show a small change in omega(e,r) and a small increase in R(transverse) with increased coverage. The bonding of Cl and F is compared to that found for O and S, both of which show a decrease in R(transverse) and O which shows a larger shift in omega(e,r).

Bauschlicher, C. W., Jr.↗

Film cooling on a convex wall: Heat transfer and hydrodynamic measurements for full and partial coverage

Turbine-blade cooling is an important issue for high-efficiency turbine engines, and discrete-hole injection is widely used as a cooling method. In the present study, detailed measurements were made of the heat transfer and hydrodynamics of a film-cooled flow on a convex wall, both for full and partial coverage. Two important parameters were altered: the blowing ratio, m, and the number of rows of injection holes. Three values of m were tested: m = 0.2, 0.4, and 0.6. In the blown region, m = 0.4 results in the lowest Stanton numbers of the three blowing ratios tested. This indicates that the value of m = 0.4 is near optimum on the convex wall from the point of view of cooling effect by injection. In the recovery region, Stanton numbers gradually approach the no injection values. Although the heat-transfer behavior during recovery from injection looks relatively complicated, the behavior of Stanton number can be explained in terms of two mechanisms: recovery from the thermal effect of injection and recovery from the turbulence augmentation. This interpretation of the data is supported by the hydrodynamic and temperture-profile measurements. For partial blowing cases, the data follow the full-coverage values inside the blown region. In the unblown region, both in the curved and in the flat plate, the effect of the number of blown rows is clearly seen. Hydrodynamic boundary-layer profiles were measured with the aid of a triple hot-water probe. Three mean-velocity components and six turbulence quantities were simultaneously measured, and inside the blown region strong three-dimensionality was observed.

Furuhama, K.↗

Coverage dependent effects on metal surfaces - O, S, F, and Cl on Ni

The c(2 x 2) and p(2 x 2) vibrational frequencies for a rigid Ni lattice are computed for O, S, F, and Cl on Ni(100). It is found that only O/Ni(100) shows a large difference in rigid lattice vibrational frequency. A large shift in rigid lattice vibrational frequency is also found for O/Ni(111) between 0.25 and 0.5 monolayer coverages. Also associated with the change in coverage, is a change in the height above the surface R(perpendicular). This varies from a 0.11 A reduction for O/Ni(100), to an expansion of 0.06 A for F/Ni(100).

Bauschlicher, C. W., Jr.↗

Multiple instrument coverage analysis

In the Space Station era comprehensive investigations of the physical processes of the earth will rely on observations from several types of space-based instruments. Preliminary studies indicate that, due to projected limitations on spacecraft and launch-vehicle capability, these complementary instrument sets may have to be distributed among several spacecraft. The task of analyzing the coincident coverage areas between instruments operating from multiple spacecraft will be complex. Such factors as the instruments' observing capabilities, orbital parameters, and viewing constraints will have to be considered. To aid in this analysis a computer model is being developed. This model has the capability, among others, to compute the coincident coverage areas between two independently orbiting instruments. This paper describes the model, its capabilities, and several sample applications.

Horvat, G. M.↗

Computation of full-coverage film-cooled airfoil temperatures by two methods and comparison with high heat flux data

Two methods were used to calculate the heat flux to full-coverage film cooled airfoils and, subsequently, the airfoil wall temperatures. The calculated wall temperatures were compared to measured temperatures obtained in the Hot Section Facility operating at real engine conditions. Gas temperatures and pressures up to 1900 K and 18 atm with a Reynolds number up to 1.9 million were investigated. Heat flux was calculated by the convective heat transfer coefficient adiabatic wall method and by the superposition method which incorporates the film injection effects in the heat transfer coefficient. The results of the comparison indicate the first method can predict the experimental data reasonably well. However, superposition overpredicted the heat flux to the airfoil without a significant modification of the turbulent Prandtl number. The results suggest that additional research is required to model the physics of full-coverage film cooling where there is significant temperature/density differences between the gas and the coolant.

Gladden, H. J.↗

Antenna Beam Coverage Concepts

The strawman Personal Access Satellite System (PASS) design calls for the use of a CONUS beam for transmission between the supplier and the satellite and for fixed beams for transmission between the basic personal terminal and the satellite. The satellite uses a 3 m main reflector for transmission at 20 GHz and a 2 m main reflector for reception at 30 GHz. There are several types of spot beams under consideration for the PASS system besides fixed beams. The beam pattern of a CONUS coverage switched beam is shown along with that of a scanning beam. A switched beam refers to one in which the signal from the satellite is connected alternatively to various feed horns. Scanning beams are taken to mean beams whose footprints are moved between contiguous regions in the beam's coverage area. The advantages and disadvantages of switched and/or scanning beams relative to fixed beams. The consequences of using switched/scanning in lieu of fixed beams in the PASS design and attempts are made to evaluate the listed advantages and disadvantages. Two uses of switched/scanning beams are examined. To illustrate the implications of switched beams use on PASS system design, operation at two beam scan rates is explored.

Estabrook, Polly↗

Reusable Reentry Satellite (RRS): Telemetry, Tracking, and Command (TT/C) Coverage Tradeoff Study

The Reusable Reentry Satellite (RRS) Telemetry, Tracking & Command (TT&C) Coverage Tradeoff Study described herein was performed during Part 1 of the RRS Phase B contract. This report is one of several that describes the results of various trade studies performed to arrive at a recommended design for the RRS satellite system. The overall RRS Phase B Study objective is to design a relatively inexpensive satellite to access space for extended periods of time, with eventual recovery of experiments on Earth. The RRS will be capable of: (1) being launched by a variety of expendable launch vehicles; (2) operating in low earth orbit as a free flying unmanned laboratory; and (3) executing an independent atmospheric reentry and soft landing. The RRS will be designed to be refurbished and reused up to three times a year for a period of 10 years. The expected principal use for such a system is research on the effects of variable gravity (0 to 1.5 g) and radiation on small animals, plants, lower life forms, tissue samples, and materials processes. This Summary Report provides a description of the RRS Telemetry, Tracking & Command Analysis performed to study the ground station coverage available to meet RRS requirements. Concepts were considered that used off-the-shelf technology, had generous margins of capability, and high reliability, were easily maintained, cost effective, and were compatible with existing support networks. From this study, a recommended RRS TT&C configuration will be developed.

Source record↗

Estimation of the fractional coverage of rainfall in climate models

The fraction of the grid cell area covered by rainfall, mu, is an essential parameter in descriptions of land surface hydrology in climate models. A simple procedure is presented for estimating this fraction, based on extensive observations of storm areas and rainfall volumes. Storm area and rainfall volume are often linearly related; this relation can be used to compute the storm area from the volume of rainfall simulated by a climate model. A formula is developed for computing mu, which describes the dependence of the fractional coverage of rainfall on the season of the year, the geographical region, rainfall volume, and the spatial and temporal resolution of the model. The new formula is applied in computing mu over the Amazon region. Significant temporal variability in the fractional coverage of rainfall is demonstrated. The implications of this variability for the modeling of land surface hydrology in climate models are discussed.

Eltahir, E. A. B.↗

CATLAC - Calibration and Validation Analysis Tool of Local Area Coverage for the SeaWiFS Mission

Calibration and validation Analysis Tool of Local Area Coverage (CATLAC) is an analysis package for selecting and graphically displaying Earth and space targets for calibration and validation activities on a polar orbiting satellite. The package is written in the Interactive Data Language (IDL) and includes a graphical user interface. Although it is designed specifically for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) mission, the package can be used for analysis on other Earth-viewing missions. An individual can use text or graphical methods in CATLAC to select Earth targets to be scanned by a satellite. Additional onboard calibration activities (such as observations of the moon, or solar irradiance from a solar diffuser), which use data recorder time, can also be specified. All information pertinent to the creation of a command schedule can be written to a file which is read by a command scheduler. The scheduler can be invoked and the Local Area Coverage (LAC) recording periods can be visually verified using CATLAC. The schedule can also be verified by examining record and error files written by the scheduler.

Woodward, Robert H.↗