Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “construction costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Fabrication of superconducting Nb 3 Sn film by Co-sputtering

High-efficiency SRF cavities are the key technology to construct cost-effective CW SRF accelerators. Improvements in the efficiency of SRF cavities are realized by using novel materials, such as niobium-tin. Advances in niobium-tin coatings on the inner surface of SRF cavities showed the potential for this material to increase the operating temperature of the SRF cavity to above 4 K, leading to significant reduction of the capital and operating cost of SRF accelerators. Among the techniques used to apply the niobium-tin coating to the surface of the SRF cavity is sputtering. Old Dominion University, Jefferson Lab, and Fermilab are collaborating on developing an optimized niobium-tin coating of the inside surface of niobium SRF cavities using a recently-developed cylindrical sputtering system. This research will result in optimized sputtering coating techniques leading to high efficiency SRF structures.

42 ENGINEERING↗

One‐at‐a‐Time Parameter Perturbation Ensemble of the Community Land Model, Version 5.1

Comprehensive land models are subject to significant parametric uncertainty, which can be hard to quantify due to the large number of parameters and high model computational costs. We constructed a large parameter perturbation ensemble (PPE) for the Community Land Model version 5.1 with biogeochemistry configuration (CLM5.1-BGC). We performed more than 2,000 simulations perturbing 211 parameters across six forcing scenarios. This provides an expansive data set, which can be used to identify the most influential parameters on a wide range of output variables globally, by biome, or by plant functional type. We found that parameter effects can exceed scenario effects and that a small number of parameters explains a large fraction of variance across our ensemble. The most important parameters can differ regionally and also based on the forcing scenario. The software infrastructure developed for this experiment has greatly reduced the human and computer time needed for CLM PPEs, which can facilitate routine investigation of parameter sensitivity and uncertainty, as well as automated calibration.

Kennedy, Daniel [NSF National Center for Atmospher↗

Reduced-basis method for few-body bound-state emulation

Recent advances in both theoretical and computational methods have enabled large-scale, precision calculations of the properties of atomic nuclei. With the growing complexity of modern nuclear theory, however, also comes the need for novel methods to perform systematic studies and quantify the uncertainties of models when confronted with experimental data. Here, this study presents an application of such an approach, the reduced basis method, to substantially lower computational costs by constructing a significantly smaller Hamiltonian subspace informed by previous solutions. Our method shows comparable efficiency and accuracy to other dimensionality reduction techniques on an artificial three-body bound system while providing a richer representation of physical information in its projection and training subspace. This methodological advancement can be applied in other contexts and has the potential to greatly improve our ability to systematically explore theoretical models and thus enhance our understanding of the fundamental properties of nuclear systems.

cluster models↗

Cost Estimation of a Permanent Magnet Synchronous Machine for Use in Adjustable Speed-Pumped Storage Hydropower

Electric machine design has become an easier process with the availability of computers in recent decades. However, the interest in electric machine design among students has declined. University-level design courses must compete with courses perceived as more desirable by the potential job market. Hence, the power system engineers with this expertise are very few and are nearing retirement. Contrarily, renewable energy has been picking up in the past few decades. The indeterminacy and variation of renewable energy sources require a balancing mechanism to maintain the constant voltage and frequency of the grid. Adjustable-Speed Pumped-Storage Hydropower plants are considered the contender for future energy storage, providing large capacity and fast-acting response. Large-scale hydropower applications depend on the natural characteristics of each project site, making less expensive, off-the-shelf generators unfeasible. This work gives a shortcut to estimate the cost of constructing a permanent magnet generator for low-volume manufacturing.

13 HYDRO ENERGY↗

Future Circular Collider Feasibility Study Report

Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. It outlines a technically feasible and economically viable civil engineering configuration that serves as the baseline for detailed subsurface investigations, construction design, cost estimation, and project implementation planning. Additionally, the report highlights ongoing subsurface investigations in key areas to support the development of an improved 3D subsurface model of the region. The report describes the development of the project scenario based on the ‘avoid-reduce-compensate’ iterative optimisation approach. The reference scenario balances optimal physics performance with territorial compatibility, implementation risks, and costs. Environmental field investigations covering almost 600 hectares of terrain—including numerous urban, economic, social, and technical aspects—confirmed the project’s technical feasibility and contributed to the preparation of essential input documents for the formal project authorisation phase. The summary also highlights the initiation of public dialogue as part of the authorisation process. The results of a comprehensive socio-economic impact assessment, which included significant environmental effects, are presented. Even under the most conservative and stringent conditions, a positive benefit-cost ratio for the FCC-ee is obtained. Finally, the report provides a summary of the studies conducted to document the current state of the environment.

Benedikt, M. [European Organization for Nuclear Re↗

General Approach to Physics Limits of Ultimate Colliders

The future of the particle physics is critically dependent on feasibility of future energy frontier colliders. The concept of the feasibility is complex and includes at least three factors: feasibility of energy, feasibility of luminosity, and feasibility of cost and construction time. Here we discuss major beam physics limits of ultimate accelerators, take a look into ultimate energy reach of possible future colliders. We also foresee a looming paradigm change for the HEP research as the thrust for higher energies by necessity will mean lower luminosity.

Shiltsev, Vladimir D.↗

Molten Salt Corrosion Tests of Additively Manufactured Stainless Steel 316H

Molten salt reactors (MSRs) have drawn considerable interest due to their favorable safety features, high thermal efficiency, and compatibility with different fuel cycles. Yet, the success of MSRs hinges critically on the performance of structural materials to be used in these aggressive molten salt environments, where corrosion and material compatibility remain primary challenges to long-term reliability. Additively manufactured (AM) nuclear structural materials prompt the use of novel geometries and compositions to enhance material performance and reduce costs of constructing MSRs. The rapid solidification conditions inherent to AM processing impart distinctive microstructural features, including cellular sub-structures, dislocation densities, residual stress, and oxide inclusions, which can influence material performance in MSR components. While the mechanical properties of AM stainless steels have been widely studied, their corrosion behavior, particularly in molten salt environments, has received far less attention. Addressing these needs, the Advanced Materials and Manufacturing Technologies (AMMT) program provides a framework for systematically evaluating how unique microstructures produced by AM processes influence the performance of these materials in these demanding environments and for developing reproducible testing workflows that can support future code qualification efforts and standards development. Bridging this knowledge gap is essential for assessing the viability of AM alloys in MSRs and informing qualification strategies. A further challenge is the absence of standardized protocols for molten salt corrosion testing. Accordingly, this report provides an account of the corrosion evaluation of AM 316H stainless steel in NaCl 2 -MgCl 2 molten salt at 550 °C, with exposure times of 100 and 500 hours. It documents the experimental procedures implemented under the AMMT program, including salt preparation, exposure protocols, and post-test characterization methods, to establish reproducibility and transparency. Importantly, the study examines AM 316H samples in the as-fabricated condition, directly reflecting the surface state most relevant to engineering applications, and compares their behavior to machine-cut surfaces. Overall, preliminary evaluations have noted that surface conditions (e.g. morphology, contamination, etc.) have a noticeable impact on the corrosion resiliency. The impact of the corrosion is difficult to detect at 100h, unless, in the case of AM 316H, the specimen surface is decontaminated. After 500 h, as-fabricated surfaces of AM and wrought 316H display evidence of general versus preferential corrosion attack, respectively. Both AM and wrought 316H machine-cut surfaces exhibit a continuous Cr depletion zone, evident of general corrosion. While the estimated extent of corrosion appears within the same order of magnitude regardless of the surface condition, it is apparent that more predictable behavior is observed on machine-cut surfaces. Nonetheless, further investigation is necessary to fully elucidate the corrosion mechanism under these conditions.

36 - MATERIALS SCIENCE↗

Li-Ion Battery Thermal Characterization for Thermal Management Design

Battery design efforts often prioritize enhancing the energy density of the active materials and their utilization. However, optimizing thermal management systems at both the cell and pack levels is also key to achieving mission-relevant battery design. Battery thermal management systems, responsible for managing the thermal profile of battery cells, are crucial for balancing the trade-offs between battery performance and lifetime. Designing such systems requires accounting for the multitude of heat sources within battery cells and packs. This paper provides a summary of heat generation characterizations observed in several commercial Li-ion battery cells using isothermal battery calorimetry. The primary focus is on assessing the impact of temperatures, C-rates, and formation cycles. Moreover, a module-level characterization demonstrated the significant additional heat generated by module interconnects. Characterizing heat signatures at each level helps inform manufacturing at the design, production, and characterization phases that might otherwise go unaccounted for at the full pack level. Further testing of a 5 kWh battery pack revealed that a considerable temperature non-uniformity may arise due to inefficient cooling arrangements. To mitigate this type of challenge, a combined thermal characterization and multi-domain modeling approach is proposed, offering a solution without the need for constructing a costly module prototype.

25 ENERGY STORAGE↗

Assessment of Economic Viability of Direct Current Fast Charging Infrastructure Investments for Electric Vehicles in the United States

As the global transportation sector increasingly adopts electric vehicles, the demand for advanced and accessible charging infrastructure is rising. In addition to at-home electric vehicle (EV) charging, there is a growing need for the swift development of commercial direct current fast charging (DCFC) stations to meet on-the-go EV charging demands. While government funds are available to support the expansion of the EV charging network in the United States, the establishment of a robust nationwide EV charging infrastructure requires significant private sector investment. This study was conducted to assess the economic feasibility of various business models for fast charging stations in the U.S. using two case studies and exploring different operational strategies including sole ownership and collaborative ventures with public and private entities. The results indicate that based on the current adoption and utilization rates in the U.S., the business model involving an owner-operator collaborating with a public partner ensures profitability and protects the investment in DCFC stations from financial losses. The study also highlights that demand charges and electricity retail prices are the factors that affect the profitability of a DCFC station.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.

Burghardt, Jeffrey A.↗

Scaling Real Estate Development Innovation With Emerging Local Area Developers

These case studies provide tangible examples within the development field that show how true innovation in real estate and property development hinges on shaping and optimizing diverse connections and relationships to create widely available, market-viable, and high-performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Boron epoxy reinforced structural sections.

A NASA Research program on the development of lightweight aluminum stiffening sections will be reviewed. The sections under investigation are hollowed extrusions which have been reinforced with boron epoxy by means of a fiber infiltration scheme being developed by Avco. Advantages of this type of construction are cost, environmental stability, manufacturing flexibility, and simplicity in joining. Present studies are focused on developing and verifying structural concepts for stiffener sections for compression panels. Results of analytical studies to size boron reinforcement will be discussed. Compression test results on stiffener sections will be presented and the design of a large compression panel will be reviewed. Results from compression panel efficiency studies indicate that panels with infiltrated stiffeners may be as much as 25% lighter than comparable all aluminum panels.-

Roy, P. A.↗

Management of analytical redundancy in digital flight control systems for aircraft

This paper presents a design method for optimal redundancy management for nonlinear systems with application to highly maneuvering aircraft. The approach taken is based on selecting the failure states to be covered by the system design and constructing a cost function that represents the cost of making an incorrect decision. The decision logic which minimizes the cost requires a bank of extended Kalman filters running in parallel. This produces a severe computational requirement. To reduce this requirement, a suboptimal logic is developed based on using a nonlinear single-stage prediction algorithm in the filters with filter gains and decision logic selected using steady-state results obtained from a linearization of the vehicle and sensor dynamics. The design process is then applied to designing a redundancy management system for the F8-C aircraft. Results indicate that the system is superior in failure detection to a system using the same structure but using a linear single-stage prediction algorithm in the filters.

Montgomery, R. C.↗

The Airfloat HL project

A design study is described for a large low-cost rigid airship intended primarily for the movement of large indivisible loads (cargo) between industrial sites. A survey of the ship and its overall performance is followed by accounts of the operational procedures for the above function and for an alternative application to unit module transfer between fixed terminals. A final section indicates the estimated costs of construction and operation. Safety factors are also considered. Lifting devices such as winches, hoists are shown and described, and airship configurations are also shown.

Mowforth, E.↗

Microwave power transmission system studies. Volume 4: Sections 9 through 14 with appendices

The microwave rectifier technology, approaches to the receiving antenna, topology of rectenna circuits, assembly and construction, ROM cost estimates are discussed. Analyses and cost estimates for the equipment required to transmit the ground power to an external user. Noise and harmonic considerations are presented for both the amplitron and klystron and interference limits are identified and evaluated. The risk assessment discussion is discussed wherein technology risks are rated and ranked with regard to their importance in impacting the microwave power transmission system. The system analyses and evaluation are included of parametric studies of system relationships pertaining to geometry, materials, specific cost, specific weight, efficiency, converter packing, frequency selection, power distribution, power density, power output magnitude, power source, transportation and assembly. Capital costs per kW and energy costs as a function of rate of return, power source and transportation costs as well as build cycle time are presented. The critical technology and ground test program are discussed along with ROM costs and schedule. The orbital test program with associated critical technology and ground based program based on full implementation of the defined objectives is discussed.

Maynard, O. E.↗

A research program to reduce interior noise in general aviation airplanes. Design of an acoustic panel test facility

The design, construction, and costs of a test facility for determining the sound transmission loss characteristics of various panels and panel treatments are described. The pressurization system and electronic equipment used in experimental testing are discussed as well as the reliability of the facility and the data gathered. Tests results are compared to pertinent acoustical theories for panel behavior and minor anomalies in the data are examined. A method for predicting panel behavior in the stiffness region is also presented.

Roskam, J.↗

Wind turbine generator application places unique demands on tower design and materials

The most relevant contractual tower design requirements and goal for the Mod-1 tower are related to steel truss tower construction, cost-effective state-of-the-art design, a design life of 30 years, and maximum wind conditions of 120 mph at 30 feet elevation. The Mod-1 tower design approach was an iterative process. Static design loads were calculated and member sizes and overall geometry chosen with the use of finite element computer techniques. Initial tower dynamic characteristics were then combined with the dynamic properties of the other wind turbine components, and a series of complex dynamic computer programs were run to establish a dynamic load set and then a second tower design.

Kita, J. P.↗

On incorporating reliability considerations into control system designs

This paper considers reliability in designing control systems for large orbital structures that are expected to have appreciable flexibility. Reliability is considered for both the control configuration (i.e. selecting sensor and actuator locations over an admissible set) and the ultimate operation of the system. The approach presented is to construct a cost function that indicates the absolute goal of the system and, for a given structural design, to determine the lowest achievable costs conditioned on the failure states of the system (i.e. which actuators and sensors are operational). These costs are then weighted and summed to provide an overall system performance measure. This measure is then minimized over the set of admissible control configurations. The approach is illustrated using a beam that has four actuators with the goal of achieving a given parabolic shape.

Montgomery, R. C.↗