Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Distance determination to eight galaxies using expanding photosphere method

Type IIP supernovae (SNe) are recognized as independent extragalactic distance indicators; however, keeping in mind the diverse nature of their observed properties as well as the availability of good quality data, more and newer events need to be tested for their applicability as reliable distance indicators. We use early photometric and spectroscopic data of eight Type IIP SNe to derive distances to their host galaxies by using the expanding photosphere method (EPM). For five of these, the EPM is applied for the first time. In this work, we improved EPM application by using SYNOW estimated velocities and by semi-deconvolving the broadband filter responses while deriving color temperatures and blackbody angular radii. We find that the derived EPM distances are consistent with that derived using other redshift-independent methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Building 235-F Goldsim Fate And Transport Model

Savannah River National Laboratory (SRNL) personnel, at the request of Area Completion Projects (ACP), evaluated In-Situ Disposal (ISD) alternatives that are under consideration for deactivation and decommissioning (D&D) of Building 235-F and the Building 294-2F Sand Filter. SRNL personnel developed and used a GoldSim fate and transport model, which is consistent with Musall 2012, to evaluate relative to groundwater protection, ISD alternatives that involve either source removal and/or the grouting of portions or all of 235-F. This evaluation was conducted through the development and use of a Building 235-F GoldSim fate and transport model. The model simulates contaminant release from four 235-F process areas and the 294-2F Sand Filter. In addition, it simulates the fate and transport through the vadose zone, the Upper Three Runs (UTR) aquifer, and the Upper Three Runs (UTR) creek. The model is designed as a stochastic model, and as such it can provide both deterministic and stochastic (probabilistic) results. The results show that the median radium activity concentrations exceed the 5 ?Ci/L radium MCL at the edge of the building for all ISD alternatives after 10,000 years, except those with a sufficient amount of inventory removed. A very interesting result was that grouting was shown to basically have minimal effect on the radium activity concentration. During the first 1,000 years grouting may have some small positive benefit relative to radium, however after that it may have a slightly deleterious effect. The Pb-210 results, relative to its 0.06 ?Ci/L PRG, are essentially identical to the radium results, but the Pb-210 results exhibit a lesser degree of exceedance. In summary, some level of inventory removal will be required to ensure that groundwater standards are met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifying spatiotemporal patterns in opioid vulnerability: investigating the links between disability, prescription opioids and opioid-related mortality

Background: The opioid crisis remains one of the most daunting and complex public health problems in the United States. This study investigates the national epidemic by analyzing vulnerability profiles of three key factors: opioid-related mortality rates, opioid prescription dispensing rates, and disability rank ordered rates. Methods: This study utilizes county level data, spanning the years 2014 through 2020, on the rates of opioid-related mortality, opioid prescription dispensing, and disability. To successfully estimate and predict trends in these opioid-related factors, we augment the Kalman Filter with a novel spatial component. To define opioid vulnerability profiles, we create heat maps of our filter’s predicted rates across the nation’s counties and identify the hotspots. In this context, hotspots are defined on a year-by-year basis as counties with rates in the top 5% nationally. Results: Our spatial Kalman filter demonstrates strong predictive performance. From 2014 to 2018, these predictions highlight consistent spatiotemporal patterns across all three factors, with Appalachia distinguished as the nation’s most vulnerable region. Starting in 2019 however, the dispensing rate profiles undergo a dramatic and chaotic shift. Conclusions: The initial primary drivers of opioid abuse in the Appalachian region were likely prescription opioids; however, it now appears that abuse is sustained by illegal drugs. Additionally, we find that the disabled subpopulation may be more at risk of opioid-related mortality than the general population. Public health initiatives must extend beyond controlling prescription practices to address the transition to and impact of illicit drug use.

60 APPLIED LIFE SCIENCES↗

Legacy Survey of Space and Time Data Preview 2: visit_table dataset type

We present Rubin Data Preview 2 (DP2), the second data preview from the NDF-DOE Vera C. Rubin Observatory. Data Preview 2 (DP2) comprises coadds, detection catalogs, and ancillary data products; and when fully released will also include single-epoch images and difference images. DP2 is derived from observations acquired by the LSST Science Camera (LSSTCam) on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile, primarily during the on-sky commissioning campaign between 2025-04-16 and 2025-09-21, supplemented by observations taken between 2025-10-25 and 2026-01-06 that overlap the commissioning footprint. The DP2 footprint comprises the Science Validation wide-area survey, five Deep Drilling Fields, and a number of targeted small-field regions, including Trifid and Lagoon, Prawn, M49, and New Horizons, all observed as part of the Rubin First Look campaign. Each field was imaged in up to six broad photometric bands, ugrizy, and coadded to produce deep imaging covering an estimated 3,000 deg2. The addition of single-visit-only areas expands the total DP2 footprint to an estimated 15,000 deg2, with coverage in at least one filter. The median per-visit PSF FWHM across the wide-area survey ranges from 1.17 arcsec in the z band to 1.26 arcsec in g and r bands. The deepest field, reaches estimated coadded 5σ depths of u=26 mag, g=26.8 mag, r=26.3 mag, i=26.1 mag, z=25.3 mag, y=23.9 mag. Based on a roughly five-month primary observing baseline and covering only part of the eventual LSST footprint, DP2's area, depth, and multiband coverage nonetheless support a broad range of early science investigations ahead of LSST Data Release This dataset is a subset of the full data release consisting of the visit_table dataset type. These are metadata, including dates and filters for every visit. This release contains 1 dataset of this type.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-BRC-04: Efficient Dose Calculation Algorithm for FFF IMRT with a Simplified Bivariate Gaussian Source Model

Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end, tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.

60 APPLIED LIFE SCIENCES↗

A description of the Galactic Center excess in the Minimal Supersymmetric Standard Model

Observations with the Fermi Large Area Telescope (LAT) indicate an excess in gamma rays originating from the center of our Galaxy. A possible explanation for this excess is the annihilation of Dark Matter particles. We have investigated the annihilation of neutralinos as Dark Matter candidates within the phenomenological Minimal Supersymmetric Standard Model (pMSSM). An iterative particle filter approach was used to search for solutions within the pMSSM. We found solutions that are consistent with astroparticle physics and collider experiments, and provide a fit to the energy spectrum of the excess. The neutralino is a Bino/Higgsino or Bino/Wino/Higgsino mixture with a mass in the range 84–92 GeV or 87–97 GeV annihilating into W bosons. A third solutions is found for a neutralino of mass 174–187 GeV annihilating into top quarks. The best solutions yield a Dark Matter relic density 0.06<Ωh{sup 2}<0.13. These pMSSM solutions make clear forecasts for LHC, direct and indirect DM detection experiments. If the pMSSM explanation of the excess seen by Fermi-LAT is correct, a DM signal might be discovered soon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EXPLORING THE z = 3-4 MASSIVE GALAXY POPULATION WITH ZFOURGE: THE PREVALENCE OF DUSTY AND QUIESCENT GALAXIES

Our understanding of the redshift z > 3 galaxy population relies largely on samples selected using the popular ''dropout'' technique, typically consisting of UV-bright galaxies with blue colors and prominent Lyman breaks. As it is currently unknown if these galaxies are representative of the massive galaxy population, we here use the FOURSTAR Galaxy Evolution (ZFOURGE) survey to create a stellar mass-limited sample at z = 3-4. Uniquely, ZFOURGE uses deep near-infrared medium-bandwidth filters to derive accurate photometric redshifts and stellar population properties. The mass-complete sample consists of 57 galaxies with log M >10.6, reaching below M {sup *} at z = 3-4. On average, the massive z = 3-4 galaxies are extremely faint in the observed optical with median R{sub tot}{sup AB}=27.48±0.41 (rest-frame M {sub 1700} = –18.05 ± 0.37). They lie far below the UV luminosity-stellar mass relation for Lyman break galaxies and are about ∼100 × fainter at the same mass. The massive galaxies are red (R – K {sub s} {sub AB} = 3.9 ± 0.2; rest-frame UV-slope β = –0.2 ± 0.3) likely from dust or old stellar ages. We classify the galaxy spectral energy distributions by their rest-frame U–V and V–J colors and find a diverse population: 46{sub −6−17}{sup +6+10}% of the massive galaxies are quiescent, 40{sub −6−5}{sup +6+7}% are dusty star-forming galaxies, and only 14{sub −3−4}{sup +3+10}% resemble luminous blue star-forming Lyman break galaxies. This study clearly demonstrates an inherent diversity among massive galaxies at higher redshift than previously known. Furthermore, we uncover a reservoir of dusty star-forming galaxies with 4 × lower specific star-formation rates compared to submillimeter-selected starbursts at z > 3. With 5 × higher numbers, the dusty galaxies may represent a more typical mode of star formation compared to submillimeter-bright starbursts.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-speed one-dimensional detector for time-resolved small -angle X-ray scattering : design and characterization.

A high-speed one-dimensional detector for time-resolved small-angle x-ray scattering has been designed and built for experiments at the Advanced Photon Source of Argonne National Laboratory. This detector is made from a 500-?m thick by 150-mm diameter ultra-high-purity n-type silicon wafer. The electrodes, which are a series of concentric rings that are deposited in the wafer, integrate the scattered x-rays over the azimuthal angle and, thereby, produce a one-dimensional detector. This design yields 128 rings, which allows parallel processing of the signal from each ring. The readout electronics consist of transimpedance front-end amplifiers, one for each ring, followed by active pulse-shaping filters. The amplifier signals are digitized using 12-bit analog-to-digital converters, one per ring, which operate at 20 MHz. The frame rate of the system is 271 kHz. Up to 220 - 1 scattering profiles may be stored on a random access memory chip and transferred to a data file at a rate of 16 x 103 profiles/sec. For X-ray energies between 3.5 and 13.2 keV the efficiency exceeds 80%. The resolving time of the electronics is 300 ns, which is sufficient to isolate electronically a single pulse of scattered x-rays when the synchrotron is operated in a hybrid or asymmetric fill pattern. Therefore, laser-pump/x-ray-probe experiments can be performed without a mechanical shutter. Examples of time-resolved speckle and the kinetics of the formation of sodium chloride particles are presented. This detector is capable of acquiring small-angle x-ray scattering profiles over multiple time scales, which are needed to characterize many chemical, physical, and biological processes. In addition, this detector may be tested and calibrated before experimental runs, without access to an intense beam of x-rays, with alpha particles from a radioactive source such as 241Am.

43 PARTICLE ACCELERATORS↗

SU-F-R-40: Robustness Test of Computed Tomography Textures of Lung Tissues to Varying Scanning Protocols Using a Realistic Phantom Environment

Purpose: The reliability of computed tomography (CT) textures is an important element of radiomics analysis. This study investigates the dependency of lung CT textures on different breathing phases and changes in CT image acquisition protocols in a realistic phantom setting. Methods: We investigated 11 CT texture features for radiation-induced lung disease from 3 categories (first-order, grey level co-ocurrence matrix (GLCM), and Law’s filter). A biomechanical swine lung phantom was scanned at two breathing phases (inhale/exhale) and two scanning protocols set for PET/CT and diagnostic CT scanning. Lung volumes acquired from the CT images were divided into 2-dimensional sub-regions with a grid spacing of 31 mm. The distribution of the evaluated texture features from these sub-regions were compared between the two scanning protocols and two breathing phases. The significance of each factor on feature values were tested at 95% significance level using analysis of covariance (ANCOVA) model with interaction terms included. Robustness of a feature to a scanning factor was defined as non-significant dependence on the factor. Results: Three GLCM textures (variance, sum entropy, difference entropy) were robust to breathing changes. Two GLCM (variance, sum entropy) and 3 Law’s filter textures (S5L5, E5L5, W5L5) were robust to scanner changes. Moreover, the two GLCM textures (variance, sum entropy) were consistent across all 4 scanning conditions. First-order features, especially Hounsfield unit intensity features, presented the most drastic variation up to 39%. Conclusion: Amongst the studied features, GLCM and Law’s filter texture features were more robust than first-order features. However, the majority of the features were modified by either breathing phase or scanner changes, suggesting a need for calibration when retrospectively comparing scans obtained at different conditions. Further investigation is necessary to identify the sensitivity of individual image acquisition parameters.

60 APPLIED LIFE SCIENCES↗

Secondary Pollutants from Ozone Reaction with Ventilation Filters and Degradation of Filter Media Additives

Prior research suggests that chemical processes taking place on the surface of particle filters employed in buildings may lead to the formation of harmful secondary byproducts. We investigated ozone reactions with fiberglass, polyester, cotton/polyester and polyolefin filter media, as well as hydrolysis of filter media additives. Studies were carried out on unused media, and on filters that were installed for 3 months in buildings at two different locations in the San Francisco Bay Area. Specimens from each filter media were exposed to {approx}150 ppbv ozone in a flow tube under a constant flow of dry or humidified air (50percent RH). Ozone breakthrough was recorded for each sample over periods of {approx}1000 min; the ozone uptake rate was calculated for an initial transient period and for steady-state conditions. While ozone uptake was observed in all cases, we did not observe significant differences in the uptake rate and capacity for the various types of filter media tested. Most experiments were performed at an airflow rate of 1.3 L/min (face velocity = 0.013 m/s), and a few tests were also run at higher rates (8 to 10 L/min). Formaldehyde and acetaldehyde, two oxidation byproducts, were quantified downstream of each sample. Those aldehydes (m/z 31 and 45) and other volatile byproducts (m/z 57, 59, 61 and 101) were also detected in real-time using Proton-Transfer Reaction - Mass Spectrometry (PTR-MS). Low-ppbv byproduct emissions were consistently higher under humidified air than under dry conditions, and were higher when the filters were loaded with particles, as compared with unused filters. No significant differences were observed when ozone reacted over various types of filter media. Fiberglass filters heavily coated with impaction oil (tackifier) showed higher formaldehyde emissions than other samples. Those emissions were particularly high in the case of used filters, and were observed even in the absence of ozone, suggesting that hydrolysis of additives, rather than ozonolysis, is the main formaldehyde source in those filters. Emission rates of formaldehyde and acetaldehyde were not found to be large enough to substantially increase indoor concentrations in typical building scenarios. Nevertheless, ozone reactions on HVAC filters cannot be ignored as a source of low levels of indoor irritants.

54 ENVIRONMENTAL SCIENCES↗

Radiological Monitoring of Waste Treatment Plant

Scheduled waste in West Malaysia is handled by Concession Company and is stored and then is incinerated. It is known that incineration process may result in naturally occurring radioactive materials (NORM) to be concentrated. In this study we have measured three samples consist of by-product from the operation process such as slag, filter cake and fly ash. Other various environmental media such as air, surface water, groundwater and soil within and around the plant have also been analysed for their radioactivity levels. The concentration of Ra-226, Ac-228 and K-40 in slag are 0.062 Bq/g, 0.016 Bq/g and 0.19 Bq/g respectively. The total activity (Ra{sub eq}) in slag is 99.5 Bq/kg. The concentration in fly ash is 0.032 Bq/g, 0.16 Bq/g and 0.34 Bq/g for Ra-226, Ac-228 and K-40 respectively resulting in Raeq of 287.0 Bq/kg. For filter cake, the concentration is 0.13 Bq/g, 0.031 Bq/g and 0.33 Bq/g for Ra-226, Ac-228 and K-40 respectively resulting in Raeq of 199.7 Bq/kg. The external radiation level ranges from 0.08 {mu}Sv/h (Administrative building) to 0.35 {mu}Sv/h (TENORM storage area). The concentration level of radon and thoron progeny varies from 0.0001 to 0.0016 WL and 0.0006 WL to 0.002 WL respectively. For soil samples, the activity ranges from 0.11 Bq/g to 0.29 Bq/g, 0.06 Bq/g to 0.18 Bq/g and 0.065 Bq/g to 0.38 Bq/g for Ra-226, Ac-228 and K-40 respectively. While activity in water, except for a trace of K-40, it is non-detectable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High spatial resolution upgrade of the electron cyclotron emission radiometer for the DIII-D tokamak

The 40-channel DIII-D electron cyclotron emission (ECE) radiometer provides measurements of T{sub e}(r,t) at the tokamak midplane from optically thick, second harmonic X-mode emission over a frequency range of 83–130 GHz. The frequency spacing of the radiometer's channels results in a spatial resolution of ∼1–3 cm, depending on local magnetic field and electron temperature. A new high resolution subsystem has been added to the DIII-D ECE radiometer to make sub-centimeter (0.6–0.8 cm) resolution T{sub e} measurements. The high resolution subsystem branches off from the regular channels’ IF bands and consists of a microwave switch to toggle between IF bands, a switched filter bank for frequency selectivity, an adjustable local oscillator and mixer for further frequency down-conversion, and a set of eight microwave filters in the 2–4 GHz range. Higher spatial resolution is achieved through the use of a narrower (200 MHz) filter bandwidth and closer spacing between the filters’ center frequencies (250 MHz). This configuration allows for full coverage of the 83–130 GHz frequency range in 2 GHz bands. Depending on the local magnetic field, this translates into a “zoomed-in” analysis of a ∼2–4 cm radial region. Expected uses of these channels include mapping the spatial dependence of Alfven eigenmodes, geodesic acoustic modes, and externally applied magnetic perturbations. Initial T{sub e} measurements, which demonstrate that the desired resolution is achieved, are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A tandem time–of–flight spectrometer for negative–ion/positive–ion coincidence measurements with soft x-ray excitation

We present a newly constructed spectrometer for negative–ion/positive–ion coincidence spectroscopy of gaseous samples. The instrument consists of two time–of–flight ion spectrometers and a magnetic momentum filter for deflection of electrons. The instrument can measure double and triple coincidences between mass–resolved negative and positive ions with high detection efficiency. First results include identification of several negative–ion/positive–ion coincidence channels following inner-shell photoexcitation of sulfur hexafluoride (SF{sub 6})

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength-selective thermal extraction for higher efficiency and power density thermophotovoltaics

Thermophotovoltaics have long been of interest as an energy conversion technology but suffer from low power density and low efficiency. Structured emitters designed to alter the emission spectrum and increase the efficiency are not stable at the necessary high emitter temperatures and also reduce the power density. Here, we propose a wavelength-selective thermal extraction device that mitigates these challenges and demonstrate a transfer-printing process needed to fabricate the device. The device consists of a ZnS solid hemisphere with a patterned thin film optical filter that passively increases the far-field radiated flux from an emitter within a wavelength band near the bandgap of a photovoltaic cell. Crucially, the device does not need to be in physical contact with the emitter and thus can be maintained at a lower temperature, circumventing the thermal stability challenge. Our work helps one to address long-standing issues with applications of thermophotovoltaics.

14 SOLAR ENERGY↗

Fast and robust all-electron density functional theory calculations in solids using orthogonalized enriched finite elements

Here, we present a computationally efficient approach to perform systematically convergent real-space all-electron Kohn-Sham density functional theory calculations for solids using an enriched finite element (FE) basis. The enriched FE basis is constructed by augmenting the classical FE basis with atom-centered numerical basis functions, comprising of atomic solutions to the Kohn-Sham problem. Notably, to improve the conditioning, we orthogonalize the enrichment functions with respect to the classical FE basis, without sacrificing the locality of the resultant basis. In addition to improved conditioning, this orthogonalization procedure also renders the overlap matrix block diagonal, greatly simplifying its inversion. Subsequently, we use a Chebyshev polynomial based filtering technique to efficiently compute the occupied eigenspace in each self-consistent field iteration. We demonstrate the accuracy and efficiency of the proposed approach on periodic unit cells and supercells. The benchmark studies show a staggering 130× speedup of the orthogonalized enriched FE basis over the classical FE basis. We also present a comparison of the orthogonalized enriched FE basis with the linearized augmented plane-wave + local orbitals basis, both in terms of accuracy and efficiency. Notably, we demonstrate that the orthogonalized enriched FE basis can handle large system sizes of ~10 000 electrons. Finally, we observe good parallel scalability of our implementation with 92% efficiency at 22× speedup for a system with 620 electrons

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monitoring Thermal Fatigue Damage In Nuclear Power Plant Materials Using Acoustic Emission

Proactive aging management of nuclear power plant passive components requires technologies to enable monitoring and accurate quantification of material condition at early stages of degradation (i.e., pre-macrocrack). Acoustic emission (AE) is well-suited to continuous monitoring of component degradation and is proposed as a method to monitor degradation during accelerated thermal fatigue tests. A key consideration is the ability to separate degradation responses from external sources such as water spray induced during thermal fatigue testing. Water spray provides a significant background of acoustic signals, which can overwhelm AE signals caused by degradation. Analysis of AE signal frequency and energy is proposed in this work as a means for separating degradation signals from background sources. Encouraging results were obtained by applying both frequency and energy filters to preliminary data. The analysis of signals filtered using frequency and energy provides signatures exhibiting several characteristics that are consistent with degradation accumulation in materials. Future work is planned to enable verification of the efficacy of AE for thermal fatigue crack initiation detection. While the emphasis has been placed on the use of AE for crack initiation detection during accelerated aging tests, this work also has implications with respect to the use of AE as a primary tool for early degradation monitoring in nuclear power plant materials. The development of NDE tools for characterization of aging in materials can also benefit from the use of a technology such as AE which can continuously monitor and detect crack initiation during accelerated aging tests.

acoustic emission↗

A novel computer-aided lung nodule detection system for CT images

Purpose: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. Methods: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. Results: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. Conclusions: A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput assessment of hypothetical zeolite materials for their synthesizeability and industrial deployability

Zeolites are important microporous framework materials, where 200+ structures are known to exist and many millions so-called hypothetical materials can be computationally created. Here, we screen the “Deem” database of hypothetical zeolite structures to find experimentally feasible and industrially relevant materials. We use established and existing criteria and structure descriptors (lattice energy, local interatomic distances, TTT angles), and we develop new criteria which are based on 5-th neighbor distances to T-atoms, tetrahedral order parameters (or, tetrahedrality), and porosity and channel dimensionality. Our filter funnel for screening the most attractive zeolite materials that we construct consists of nine different types of criteria and a total of 53 subcriteria. The funnel reduces the pool of candidate materials from initially >300,000 to 70 and 33, respectively, depending on the channel dimensionality constraint applied (2- and 3-dimensional vs. only 3-dimensional channels). Here, we find that it is critically important to define longer range and more stringent criteria such as the new 5-th neighbor distances to T-atoms and the tetrahedrality descriptor in order to succeed in reducing the huge pool of candidates to a manageable number. Apart from four experimentally achieved structures (BEC, BOG, ISV, SSF), all other candidates are hypothetical frameworks, thus, representing most valuable targets for synthesis and application. Detailed analysis of the screening data allowed us to also propose an exciting future direction how such screening studies as ours could be improved and how framework generating algorithms could be competitively optimized.