Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Protorheology

We all instinctively poke, bounce, scoop, and observe materials to understand rheological properties quickly. Yet, these observations are rarely analyzed quantitatively. To address this, here we introduce the paradigm of protorheology: approximate quantitative inference from simple observations. Several case studies demonstrate how protorheology is an inclusive entry to rheology for a broad range of practitioners and strengthens the confidence and interpretation of accurate laboratory measurements. We survey a range of creative tests according to which rheological phenomenon is revealed. Some new working equations are derived, and all working equations are summarized for convenient reference and comparison across different methods. Finally, this establishes a framework to enable increased use of photos, videos, and quantitative inference and to support the increasing interest in digital image analysis, inverse methods, and high-throughput characterization being applied to rheological properties.

42 ENGINEERING↗

Statistical analysis of time transfer data from Timation 2

Between July 1973 and January 1974, three time transfer experiments using the Timation 2 satellite were conducted to measure time differences between the U.S. Naval Observatory and Australia. Statistical tests showed that the results are unaffected by the satellite's position with respect to the sunrise/sunset line or by its closest approach azimuth at the Australian station. Further tests revealed that forward predictions of time scale differences, based on the measurements, can be made with high confidence.

Luck, J. M.↗

Spectroscopic parallaxes of MAP region stars from UBVRI, DDO, and uvbyH-beta photometry

This paper presents the results of spectral type and luminosity classification of reference stars in the Allegheny Observatory MAP parallax program, using broadband and intermediate-band photometry. In addition to the use of UBVRI and DDO photometric systems, the uvbyH-beta photometric system was included for classification of blue (B - V less than 0.6) reference stars. The stellar classifications made from the photometry are used to determine spectroscopic parallaxes. The spectroscopic parallaxes are used in turn to adjust the relative parallaxes measured with the MAP to absolute parallaxes. A new method for dereddening stars using more than one photometric system is presented. In the process of dereddening, visual extinctions, spectral types, and luminosity classes are determined, as well as a measure of the goodness of fit. The measure of goodness of fit quantifies confidence in the stellar classifications. It is found that the spectral types are reliable to within 2.5 spectral subclasses.

Persinger, Tim↗

Toward achieving global sole means radionavigation systems

This paper briefly reviews tentative requirements for global, earth-referenced sole means of navigation systems with emphasis on integrity and availability. These requirements can be allocated to integrated navigation system architectures based on for instance GPS, GLONASS, VOR/DME, TACAN, Omega, Chayka, and Loran-C. Fault detection and isolation techniques (FDI) for integrated radio navigation systems are presented. The FDI algorithm provides a protection radius with a specified confidence level as a function of measurement geometry and algorithm requirements. This is followed by a case study of integrated GPS/Loran-C.

Vangraas, F.↗

A 3-D Magnetic Analysis of a Linear Alternator For a Stirling Power System

The NASA Glenn Research Center and the Department of Energy (DOE) are developing advanced radioisotope Stirling convertors, under contract with Stirling Technology Company (STC), for space applications. Of critical importance to the successful development of the Stirling convertor for space power applications is the development of a lightweight and highly efficient linear alternator. This paper presents a 3-D finite element method (FEM) approach for evaluating Stirling convertor linear alternators. Preliminary correlations with open-circuit voltage measurements provide an encouraging level of confidence in the model. Spatial plots of magnetic field strength (H) are presented in the region of the exciting permanent magnets. These plots identify regions of high H, where at elevated temperature and under electrical load, the potential to alter the magnetic moment of the magnets exists. This implies the need for further testing and analysis.

Geng, Steven M.↗

Technical Evaluation Report for Symposium AVT-147: Computational Uncertainty in Military Vehicle Design

The complexity of modern military systems, as well as the cost and difficulty associated with experimentally verifying system and subsystem design makes the use of high-fidelity based simulation a future alternative for design and development. The predictive ability of such simulations such as computational fluid dynamics (CFD) and computational structural mechanics (CSM) have matured significantly. However, for numerical simulations to be used with confidence in design and development, quantitative measures of uncertainty must be available. The AVT 147 Symposium has been established to compile state-of-the art methods of assessing computational uncertainty, to identify future research and development needs associated with these methods, and to present examples of how these needs are being addressed and how the methods are being applied. Papers were solicited that address uncertainty estimation associated with high fidelity, physics-based simulations. The solicitation included papers that identify sources of error and uncertainty in numerical simulation from either the industry perspective or from the disciplinary or cross-disciplinary research perspective. Examples of the industry perspective were to include how computational uncertainty methods are used to reduce system risk in various stages of design or development.

Radespiel, Rolf↗

Reply to ''Comments on 'Why Hasn't Earth Warmed as much as Expected?'''

In response to our article, Why Hasnt Earth Warmed as Much as Expected? (2010), Knutti and Plattner (2012) wrote a rebuttal. The term climate sensitivity is usually defined as the change in global mean surface temperature that is produced by a specified change in forcing, such as a change in solar heating or greenhouse gas concentrations. We had argued in the 2010 paper that although climate models can reproduce the global mean surface temperature history over the past century, the uncertainties in these models, due primarily to the uncertainty in climate forcing by airborne particles, mean that the models lack the confidence to actually constrain the climate sensitivity within useful limits for climate prediction. Knutti and Plattner are climate modelers, and they argued essentially that because the models could reproduce the surface temperature history, the issue we raised was moot. Our response amounts to straightening out this confusion; for the models to be constraining, they must be able to reproduce the surface temperature history with sufficient confidence, not just to match the measurements, but to exclude alternative histories. As before, we concluded that if we can actually make the aerosol measurements using currently available, state-of-the-art techniques, we can determine the aerosol climate forcing to the degree required to constrain that aspect of model climate sensitivity. A technical issue relating to the timescale over which a change in CO2 emissions would be equilibrated in the environmental energy balance was also discussed, again, a matter of differences in terminology.

Schwartz, Stephen E.↗

Thermal Emission from the Earth-sized Exoplanet TRAPPIST-1 b using JWST

The TRAPPIST-1 system is remarkable for its seven planets that are similar in size, mass, density, and stellar heating to the rocky planets Venus, Earth, and Mars in our own Solar System [1]. All TRAPPIST-1 planets have been observed with the transmission spectroscopy technique using the Hubble or Spitzer Space Telescopes, but no atmospheric features have been detected or strongly constrained [2–5]. TRAPPIST-1 b is the closest planet to the system’s M dwarf star, and it receives 4 times as much irradiation as Earth receives from the Sun. This relatively large amount of stellar heating suggests that its thermal emission may be measurable. Here we present photometric secondary eclipse observations of the Earth-sized TRAPPIST1 b exoplanet using the F1500W filter of the MIRI instrument on JWST. We detect the secondary eclipse in each of five separate observations with 8.7-sigma confidence when all data are combined. These measurements are most consistent with re-radiation of the TRAPPIST-1 star’s incident flux from only the dayside hemisphere of the planet. The most straightforward interpretation is that there is little or no planetary atmosphere redistributing radiation from the host star and also no detectable atmospheric absorption from carbon dioxide (CO 2 ) or other species.

Thermal Emission↗

Level Indicator On A Tubular Inside Micrometer

Leveling helps to ensure accurate measurements. Attachment helpful because in some situations that involve measurement of large, tight-tolerance inside dimensions, inside micrometers not held level between contact point give inaccurate readings. User adjusts position and orientation of micrometer and verifies level by observing bubble in level indicator. Upon feeling correct drag between micrometer tips and workpiece, user confident that tool used correctly and accurate measurement obtained.

Malinzak, R. Michael↗

Constraining primordial non-Gaussianity with DESI 2024 LRG and QSO samples

We analyse the large-scale clustering of the Luminous Red Galaxy (LRG) and Quasar (QSO) sample from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). In particular, we constrain the primordial non-Gaussianity (PNG) parameter f NL loc via the large-scale scale-dependent bias in the power spectrum using 1,631,716 LRGs (0.6 < z < 1.1) and 1,189,129 QSOs (0.8 < z < 3.1). This new measurement takes advantage of the enormous statistical power at large scales of DESI DR1 data, surpassing the latest data release (DR16) of the extended Baryon Oscillation Spectroscopic Survey (eBOSS). For the first time in this kind of analysis, we use a blinding procedure to mitigate the risk of confirmation bias in our results. We improve the model of the radial integral constraint proposing an innovative technique allowing the correction through the window matrix convolution. We also carefully test the mitigation of the dependence of the target selection on the photometry qualities by incorporating an angular integral constraint contribution to the window function, and validate our methodology with the blinded data. Finally, combining the two samples, we measure f NL loc = -3.6 -9.1 +9.0 at 68% confidence, where we assume the universality relation for the LRG sample and a recent merger model for the QSO sample about the response of bias to primordial non-Gaussianity. Adopting the universality relation for the PNG bias in the QSO analysis leads to f NL loc = 3.5 -7.4 +10.7 at 68% confidence. Due to restricted selection in the LRG sample, the inclusion of the LRGs allows for 10% improvement. This measurement is the most precise determination of primordial non-Gaussianity using large-scale structure to date, surpassing the latest result from eBOSS by a factor of 2.3.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct measurement of MPD thrust

An integrally mounted accelerometer has been used to obtain direct thrust measurements during operation of a magnetoplasmadynamic (MPD) thruster. The structural oscillations which can mask the accelerometer output have been ameliorated by stiffening the thruster to increase the lowest resonant frequency above the 1kHz region of interest. In addition, signal conditioning is used to provide a high signal-to-noise accelerometer output waveform. Impulse response measurement of the thruster frequency response function has proven to be an effective means of selecting the signal filter and estimating measurement errors. Comparison of the total impulse derived from the accelerometer output with that from a swinging arm thrust stand indicates 3 percent agreement, providing some confidence in the viability of the accelerometer thrust measurement technique.

Berg, J. M.↗

Investigation of Proton Beam-Driven Fusion Reactions Generated by an Ultra-Short Petawatt-Scale Laser Pulse

We present results from a pitcher-catcher experiment utilizing a proton beam generated with nanostructured targets at a petawatt-class, short-pulse laser facility to induce proton-boron fusion reactions in a secondary target. A 45-fs laser pulse with either 400 nm wavelength and 7 J energy, or 800 nm and 14 J, and an intensity of up to 5 × 10 21 W/cm 2 was used to irradiate either thin foil targets or near-solid density, nanostructured targets made of boron nitride (BN) nanotubes. In particular, for 800 nm wavelength irradiation, a BN nanotube target created a proton beam with about five times higher maximum energy and about ten times more protons than a foil target. This proton beam was used to irradiate a thick plate made of boron nitride placed in close proximity to trigger 11 B (p, α) 2α fusion reactions. A suite of diagnostics consisting of Thomson parabola ion spectrometers, postshot nuclear activation measurements, neutron time-of-flight detectors, and differentially filtered solid-state nuclear track detectors were used to measure both the primary proton spectrum and the fusion products. From the primary proton spectrum, we calculated (p, n) and (α,n) reactions in the catcher and compare with our measurements. The nuclear activation results agree quantitatively and neutron signals agree qualitatively with the calculations, giving confidence that primary particle distributions can be obtained from such measurements. These results provide new insights for measuring the ion distributions inside of proton-boron fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the Relationship between the Total and Window Channel Nighttime Radiances for the CERES Instrument

Observing Earth s radiant energy budget from space is critical to improving our understanding of Earth s climate system. The Earth Radiation Budget Experiment (ERBE) was the first initiative to provide simultaneous observations of Earth s radiant energy with identical instruments flying aboard separate satellites. The design of the ERBE instrument was based upon three complementary broadband radiometers which measured the shortwave (< 5 mm), longwave (> 5 mm), and total regions of the spectrum. Since any two of the ERBE radiometers could be used to simulate the third, a three channel intercomparison, based on redundancy, was available to uncover any changes in the relative sensitivities of the individual radiometers. Such a three channel intercomparison thus provided confidence in the application of the ERBE measurements over the lifetime of the instrument while mitigating the concern over instrument degradation.

Kratz, David P.↗

How To Maintain Effective IAEA Safeguards While Reducing Facility Impact

For almost twenty years, inspectors from the International Atomic Energy Agency have been visiting the K-Area Material Storage facility at the Savannah River Site where excess plutonium has been placed under IAEA safeguards as part of the United States Volunatary Offer Agreement. During that time, the mission of K-Area Complex has expanded from storage of nuclear matieral to glovebox operations in support of the National Nuclear Security Administration’s Plutonium Disposition program. With this change in mission, it is becoming increasingly challenging to manage facility staff radiation exposure and operating activities during the IAEA’s annual Physcial Inventory Verifications (PIV). This study has identified both near-term and long-term recommendations for IAEA monitoring protocols that would allow the IAEA to maintain effective safeguards of the material while decreasing the impact to the facility. A statisitical analysis has shown that reducing the number of containers measured during an annual PIV from 12 to 4 still ensures a high level of confidence in the confidence while reducing the inspector time in the facility amd with a corresponding significant reduction in personnel radiation exposure. A modified installation pattern of Remotely Monitored Sealing Arrays (RMSAs) is also proposed utilizing only the outer rows of arrays of stored material containers in the Stack Area (SA). The modified RMSA placement will provide equivalent protection, while significantly reducing personnel radiological exposure, manpower requirements and associated costs. With advances in technology, there are additional potential options in containment/surveillance and continuity of knowledge that would allow the agency to be outside of the facility during PIV measurements and have confidence in the accuracy and authencitity of the results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equibiaxial Flexure Strength of a Superfine-Grained Nuclear Graphite

The strength of advanced graphite is reported in accordance with ASTM D7846-16 using a two-parameter Weibull distribution for uniaxial strength testing. The rule of thumb for Weibull distributions is to use a minimum of 30 strength measurements to have a high level of confidence in the Weibull characteristic strength and the Weibull modulus. These large sample sets for statistical confidence are easily obtained for as-manufactured graphite, but determination of the Weibull two-factor parameters on graphite that has been exposed to neutron irradiation is nearly impossible due to irradiation testing restraints on specimen size and space limitations in test reactors for the accommodation of specimens. These restrictions have resulted in irradiation programs that use sub-sized specimens to measure uniaxial strength change, but the specimen geometries still hinder the number of replicate specimens for each irradiation condition. In contrast, this work used an advanced ceramic standard, ASTM C1499-05, as the foundation for equibiaxial strength testing of a superfine-grained nuclear graphite to investigate the irradiation-induced strength change and any changes to the two-parameter Weibull distribution. The goal was to investigate the effect of specimen size on the two-parameter Weibull distribution parameters in support of the small specimens and geometry desired for irradiation. A study of the effect of a reduced sample population was also undertaken to investigate the reliability of using the two-parameter Weibull distribution to study changes to the materials properties caused by neutron irradiation damage. The results of this work suggest that these equibiaxial specimens would be ideal for statistically significant studies of the effects of irradiation on the Weibull characteristic strength (but not the modulus) and for providing a method for surveillance specimen campaigns for future operating commercial reactors.

Campbell, Anne↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an infrared analyzer following the

A radar calibration subsystem for measuring the radar backscattering characteristics of an imaged terrain is described. To achieve the required accuracy for the backscattering coefficient measurement (about 2 dB with 80 percent confidence), the space hardware design includes a means of monitoring the state parameters of the radar. For example, the transmitter output power is sampled and a replica of its output waveform is circulated through the receiver. These are recorded digitally and are used on the ground to determine such radar parameters as the transmitter power and the receiver gain. This part of the data is needed by the ground processor to measure the terrain backscattering characteristics.

Advanced Projects Lab↗