Computer Simulations of a Rectangular,Sinusoidally Corrugated, 220 GHz Slow-Wave Structure with Path to its 3D-Printing and "Cold" Electromagnetic Analysis
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The critical heat flux (CHF) of potential accident tolerant fuel (ATF) cladding materials and concepts, Cr and FeCrAl coatings on zirconium-alloy substrates, was investigated experimentally. A cold spray process, which involves the propulsion of high velocity powder particles on to the substrate surface to form a coating upon impact, was used to create the coatings. Surface parameters such as contact angle, surface roughness, and morphology that are associated with CHF in pool boiling were characterized. Non-hydrodynamic effects of newly developed ATF candidate coating materials on CHF were also evaluated. The effects of thermal properties and coating thickness and expected challenges for evaluation of CHF for new ATF cladding materials development are discussed.
El Niño–Southern Oscillation (ENSO) is a major source of seasonal western North Pacific (WNP) tropical cyclone (TC) predictability. However, the spatial characteristics of ENSO have changed in recent decades, from warming more typically in the eastern equatorial Pacific during canonical or cold tongue El Niño to warming more typically in the central equatorial Pacific during noncanonical or warm pool El Niño. We investigated the response in basinwide WNP TC activity and spatial clustering of TC tracks to the location and magnitude of El Niño using observations, TC-permitting tropical channel model simulations, and a TC track clustering methodology. We found that simulated western North Pacific TC activity, including accumulated cyclone energy (ACE) and the number of typhoons and intense typhoons, is more effectively enhanced by sea surface temperature warming of the central, compared to the eastern, equatorial Pacific. El Niño also considerably influenced simulated TC tracks regionally, with a decrease in TCs that were generated near the Asian continent and an increase in clusters that were dominated by TC genesis in the southeastern WNP. This response corresponds with the spatial pattern of reduced vertical wind shear and is most effectively driven by central Pacific SST warming. Finally, internal atmospheric variability generated a substantial range in the simulated season total ACE (±25% of the median). However, extremely active WNP seasons were linked with El Niño, rather than internal atmospheric variability, in both observations and climate model simulations.
The Oak Ridge National Laboratory has built and operated 13 nuclear reactors in its 66-year history. The first was the graphite reactor, the world's first operational nuclear reactor, which served as a plutonium production pilot plant during World War II. It was followed by two aqueous-homogeneous reactors and two red-hot molten-salt reactors that were parts of power-reactor development programs and by eight others designed for research and radioisotope production. One of the eight was an all-metal fast burst reactor used for health physics studies. All of the others were light-water cooled and moderated, including the famous swimming-pool reactor that was copied dozens of times around the world. Two of the reactors were hoisted 200 feet into the air to study the shielding needs of proposed nuclear-powered aircraft. The final reactor, and the only one still operating today, is the High Flux Isotope Reactor (HFIR) that was built particularly for the production of californium and other heavy elements. With the world's highest flux and recent upgrades that include the addition of a cold neutron source, the 44-year-old HFIR continues to be a valuable tool for research and isotope production, attracting some 500 scientific visitors and guests to Oak Ridge each year. This report describes all of the reactors and their histories.
Control of the REDuction/OXidation (REDOX) state of glass in High Level Waste (HLW) melters, such as the Defense Waste Processing Facility (DWPF), is critical in order to eliminate the formation of metallic species from overly reduced melts while minimizing foaming from overly oxidized melts. The REDOX control is normally a balance of the oxidants and reductants from the feed and from processing additives. However, after reflux in the Sludge Receipt and Adjustment Tank (SRAT) and the Slurry Mix Evaporator (SME), the balance between the oxidizing salts vs. reducing salts can be altered once the mixture is fed to the melter if the melt pool is bubbled with gaseous species that either oxidize or sparge the melt of oxygen. Hence, for a bubbled melt pool, the REDOX of the melt pool must be targeted based on the balance of the oxidizing and reducing salts from the feed and from the processing additives, as well as, accounting for the effects of any gas being bubbled through the melt to improve convection and mixing while also increasing melt rate. For example, one would not set a REDOX target of Fe 2+ /ΣFe of 0.20 based on chemical balancing and then bubble pure air through the melter as pure air would oxidize the melt pool to an Fe 2+ /ΣFe ~0. Some gases, such as argon, are inert but act as chemical sparging agents or “degassing” agents that can sparge out oxygen from the melt and cause the glass to become more reducing. This study examines DWPF flowsheets at various concentrations of antifoam (a reducing processing additive) in the absence of melt pool bubbling (crucible and production data) and in the presence of melt pool bubbling with argon (crucible and production data), a known sparging/degassing agent. In order to de-convolute the impacts of antifoam on the melt pool REDOX from the impacts of melt pool bubbling, crucible studies were performed with (1) varying antifoam concentrations without bubbling, and (2) minimal antifoam with Ar bubbling. This allowed an antifoam term to be added to the REDOX model and suggested that (1) more oxidizing Fe 2+ /ΣFe ratios could be targeted which would create more oxidizing species in the cold cap to offset the effects of Ar-sparging or (2) Ar-air gas mixtures could be blended with a mixing valve to control the melt pool REDOX at the same Fe 2+ /ΣFe ratios (same –log fO 2 ) as chosen for the chemical REDOX balancing. The 2006 EE REDOX model is an electron equivalents (EE) model that balances the electrons lost during oxidation of a reductant against the electrons gained during the reduction of an oxidant. The EE terms for the formates, nitrates, and oxalates in the REDOX model are based on the formatted salts like NaCOOH, the nitrated salts like NaNO 3 , and the oxalated salts like Na 2 C 2 O 4 that have higher decomposition temperatures than their acidic counterparts which flash off. Thus it is the higher decomposition salts that participate in the establishing the melt REDOX during their interactions in the melter cold cap.
Over the convectively active tropical ocean regions, the measurement made from space in the IR and visible spectrum have revealed the presence of optically thin cirrus clouds, which are quite transparent in the visible and nearly opaque in the IR. The Nimbus-4 IR Interferometer Spectrometer (IRIS), which has a field of view (FOV) of approximately 100 km, was utilized to examine the IR optical characteristics of these cirrus clouds. From the IRIS data, it was observed that these optically thin cirrus clouds prevail extensively over the warm pool region of the equatorial western Pacific, surrounding Indonesia. It is found that the seasonal cloud cover caused by these thin cirrus clouds exceeds 50 percent near the central regions of the warm pool. For most of these clouds, the optical thickness in the IR is less than or = 2. It is deduced that the dense cold anvil clouds associated with deep convection spread extensively and are responsible for the formation of the thin cirrus clouds. This is supported by the observation that the coverage of the dense anvil clouds is an order of magnitude less than that of the thin cirrus clouds. From these observations, together with a simple radiative-convective model, it is inferred that the optically thin cirrus can provide a greenhouse effect, which can be a significant factor in maintaining the warm pool. In the absence of fluid transports, it is found that these cirrus clouds could lead to a runaway greenhouse effect. The presence of fluid transport processes, however, act to moderate this effect. Thus, if a modest 20 W/sq m energy input is considered to be available to warm the ocean, then it is found that the ocean mixed-layer of a 50-m depth will be heated by approximately 1 C in 100 days.
Nuclear reactor safety analysis requires identifying various credible accident scenarios and determining their consequences. For a full-scale nuclear power plant system behavior, it is impossible to obtain sufficient experimental data for a broad range of risk-significant accident scenarios. In single-phase flow convective problems, Direct Numerical Simulation (DNS) and Large Eddy Simulation (LES) can provide us with high fidelity results when physical data are unavailable. However, these methods are computationally expensive and cannot be afforded for simulation of long transient scenarios in nuclear accidents despite extraordinary advances in high performance scientific computing over the past decades. The major issue is the inability to make the transient computation parallel, thus making number of time steps required in high-fidelity methods unaffordable for long transients. In this work, we propose to apply a high fidelity simulation-driven approach to model sub-grid scale (SGS) effect in Coarse Grained Computational Fluid Dynamics CG-CFD. This approach aims to develop a statistical surrogate model instead of the deterministic SGS model. We chose to start with a turbulent natural convection case with volumetric heating in a horizontal fluid layer with a rigid, insulated lower boundary and isothermal (cold) upper boundary. This scenario of unstable stratification is relevant to turbulent natural convection in a molten corium pool during a severe nuclear reactor accident, as well as in containment mixing and passive cooling. The presented approach demonstrates how to create a correction for the CG-CFD solution by modifying the energy balance equation. A global correction for the temperature equation proves to achieve a significant improvement to the prediction of steady state temperature distribution through the fluid layer.
Observations from a geostationary satellite are used to study the life cycle of mesoscale convective systems (MCS), their associated anvil clouds, and their effects on the radiation balance over the warm pool of the tropical western Pacific Ocean. In their developing stages, MCS primarily consist of clouds that are optically thick and have a negative net cloud radiative effect (CRE). As MCS age, ice crystals in the anvil become larger, the cloud top lowers somewhat, and cloud radiative effects decrease in magnitude. Shading from anvils causes cool anomalies in the underlying sea surface temperature (SST) of up to −0.6°C. MCS often occur in clusters that are embedded within large westward-propagating disturbances, and therefore shading from anvils can cool SSTs over regions spanning hundreds of kilometers. Triggering of convection is more likely to follow a warm SST anomaly than a cold SST anomaly on a time scale of several days. This information is used to evaluate hypotheses for why, over the warm pool, the average shortwave and longwave CRE are individually large but nearly cancel. The results are consistent with the hypothesis that the cancellation in CRE is caused by feedbacks among cloud albedo, large-scale circulation, and SST.
This dataset contains bud cold hardiness measurements from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site (Hanson et al, 2017) within the Marcell Experimental Forest in northern Minnesota, USA. Cold hardiness was quantified as the temperature at which low temperature exotherms (LTEs) were identified (i.e., the temperature at which supercooled water within a bud freezes) measured by differential thermal analysis (DTA). Buds were sampled at semi-regular intervals from September 2021 through May 2025 (2021-09-25 to 2025-05-21) across four seasons (2021-2022 through 2024-2025) for four co-occurring boreal peatland tree and shrub species: Picea mariana (PIMA), Larix laricina (LALA), Rhododendron groenlandicum (RHGR), and Chamaedaphne calyculata (CHCA). Samples were collected across the experiment's warming gradient (ambient to +9 degrees Celsius (C)) and pooled by species within each enclosure. These data were used to assess the species- and season-specific effects of experimental warming on cold hardiness and cold damage risk in boreal peatland vegetation (Campos-Arguedas et al, accepted). This dataset contains one data file in comma-separate values (*.csv) format. Additional metadata are provided: a data dictionary and a file-level metadata file in comma-separate values (*.csv) format and a user guide in PDF (*.pdf) format.
The work described in this report is preliminary in nature since its goal was to demonstrate the feasibility of estimating the off-gas entrainment rates from the Defense Waste Processing Facility (DWPF) melter based on a simple mass balance using measured feed and glass pour stream compositions and time-averaged melter operating data over the duration of one canister-filling cycle. The only case considered in this study involved the SB6 pour stream sample taken while Canister #3472 was being filled over a 20-hour period on 12/20/2010, approximately three months after the bubblers were installed. The analytical results for that pour stream sample provided the necessary glass composition data for the mass balance calculations. To estimate the “matching” feed composition, which is not necessarily the same as that of the Melter Feed Tank (MFT) batch being fed at the time of pour stream sampling, a mixing model was developed involving three preceding MFT batches as well as the one being fed at that time based on the assumption of perfect mixing in the glass pool but with an induction period to account for the process delays involved in the calcination/fusion step in the cold cap and the melter turnover.
The conceptual research reactor design with a split core for a replacement reactor project at the NIST (National Institute of Standards and Technology) Center for Neutron Research is underway. The reactor core is cooled and moderated by light water and reflected by heavy water in a reflector tank. The reactor core is immersed in light water, which is isolated from heavy water with a slightly pressurized boundary box made of zirconium alloy. The heavy water is contained in a large size cylindrical tank which also provides ample space to accommodate neutron beam tubes, cold sources and other irradiation equipment. The reflector tank is placed in the center of a large light water pool, which provides thermal and biological shielding to the reactor. Light water and heavy water have distinct physical properties in regard to neutron moderation. Light water is generally known to have greater moderating power and absorption cross-sections, while heavy water has a higher moderating ratio. Due to these differences in properties, the accidental mixing of light water and heavy water in either direction will inevitably affect the reactivity of the reactor. Moreover, since the neutron flux spectrum at different locations of the reactor will have significantly different characteristics (for example, the spectrum at the heavy tank should be much softer than that at the core center region), the effect of reactivity changes becomes complicated and will depend on the water mixing locations. From the reactor safety analysis perspective, the water ingress reactivity change is one of the required design base reactivity accidents that must be evaluated in the final safety analysis report. Given these concerns, neutronics calculations have been performed to determine the effect and trend of the reactivity changes due to water ingress in different scenarios by purposely mixing the waters at three representative places in the reactor: the reflector area, the center coolant area and the peripheral coolant area. These three places were selected for the study because of their uniqueness in the flux spectrum (as shown in the results section). Simple static neutronics calculations were performed using MCNP6 to examine the reactivity effects due to water ingress. It should be noted that all calculations performed in this study assume homogeneous water mixing in the area of interest; therefore, the local effect of the mixing situation would possibly be missed by this study. (authors)
The concept of coating the currently used nuclear fuel cladding (zirconium-based alloy, typically Zircaloy-4 or Zirc-4) with an oxidation preventive layer is a progressing Accident tolerant Fuel (ATF) candidate alloys. The coated Zirc-4-based alloys could be a solution to suppress undesirable fast reaction kinetics with high-temperature steam. Zirc-4 has been the most preferred cladding material in pressurized water reactors (PWRs). Chromium (Cr) based alloys as a coating material provides excellent corrosion protection and good strength and wear resistance. In this paper, we present the surface wettability measurements and pool boiling Critical Heat Flux (CHF) for Cr-coated Zirc-4 claddings pre- and post-exposure to an ion irradiation environment. The wettability measurements, including static contact angle (contact angle, θ) and average surface roughness (surface roughness, Ra), are introduced for samples of different coating thicknesses (5–30 μm thick). The coatings fabricated by the cold spray of Cr-Al particles to 10 mm × 10 mm × 1.95 mm Zirc-4 substrates. Post fabrication, a Pilgering (cold rolling) process, was applied to finalize the coating thickness and resulted in a significant reduction in surface roughness of initially fabricated rough surfaces. The process produced three distinguished samples 5-μm unpolished (as machined), 5-μm, and 30-μm polished (cold rolled). The measurements are presented for the three surfaces and bare Zirc-4 as a baseline surface. The contact angle analyses were implemented in theoretical models from the literature to predict pool boiling CHF. Pool boiling experiments were conducted to measure the pool boiling CHF values and compare them to the predicted values. Scanning Electron Microscope (SEM) images and Energy Dispersive X-ray Spectroscopy (EDS) analysis was performed to characterize the surfaces for better understanding and interpreting the results. The SEM images showed localized surface damage due to ion irradiation. No recognized change in the measured surface roughness due to ion irradiation. The contact angles of irradiated Cr-coated surfaces are consistently higher (10°) than pre-irradiated surfaces. Decreasing the Cr-coating layer thickness resulted in lower contact angle pre- and post- ion irradiation. The predicted pool boiling CHF using the Kandlikar model is in good agreement with the experimentally measured CHF values within ±12% for all samples.
This paper presents preliminary analysis using a finite volume based computational method for network flow analysis for the simulation of chill and fill of a cryogenic tank. An axisymmetric two-dimensional model of a spherical tank was developed using a nodal approach. No Vent Filling (NVF) was accomplished using a Thermodynamic Vent System assisted injector where the injector was cooled by the cold gas generated by Joule-Thompson expansion of the liquid propellant. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around spray droplets, and c) condensation of vapor at the interface of the cooled injector and ullage. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data and one-dimensional (1D) model predictions. It was demonstrated that the axisymmetric 2D model provided a more realistic prediction than the 1D model.
The principal objective of this work was to determine the glass production rate increase and ancillary effects of adding more bubbler outlets to the current WTP HLW melter baseline. This was accomplished through testing on the HLW Pilot Melter (DM1200) at VSL. The DM1200 unit was selected for these tests since it was used previously with several HLW waste streams including the four tank wastes proposed for initial processing at Hanford. This melter system was also used for the development and optimization of the present baseline WTP HLW bubbler configuration for the WTP HLW melter, as well as for MACT testing for both HLW and LAW. Specific objectives of these tests were to: Conduct DM1200 melter testing with the baseline WTP bubbling configuration and as augmented with additional bubblers. Conduct DM1200 melter testing to differentiate the effects of total bubbler air flow and bubbler distribution on glass production rate and cold cap formation. Collect melter operating data including processing rate, temperatures at a variety of locations within the melter plenum space, melt pool temperature, glass melt density, and melter pressure with the baseline WTP bubbling configuration and as augmented with additional bubblers. Collect melter exhaust samples to compare particulate carryover for different bubbler configurations. Analyze all collected data to determine the effects of adding more bubblers to the WTP HLW melter to inform decisions regarding future lid re-designs. The work used a high aluminum HLW stream composition defined by ORP, for which an appropriate simulant and high waste loading glass formulation were developed and have been previously processed on the DM1200.
We analyzed the relationship between net ecosystem exchange of carbon dioxide (NEE) and irradiance (as photosynthetic photon flux density or PPFD), using published and unpublished data that have been collected during midgrowing season for carbon balance studies at seven peatlands in North America and Europe, NEE measurements included both eddy-correlation tower and clear, static chamber methods, which gave very similar results. Data were analyzed by site, as aggregated data sets by peatland type (bog, poor fen, rich fen, and all fens) and as a single aggregated data set for all peatlands. In all cases, a fit with a rectangular hyperbola (NEE = alpha PPFD P(sub max)/(alpha PPFD + P(sub max) + R) better described the NEE-PPFD relationship than did a linear fit (NEE = beta PPFD + R). Poor and rich fens generally had similar NEE-PPFD relationships, while bogs had lower respiration rates (R = -2.0 micro mol m(exp -2) s(exp -1) for bogs and -2.7 micro mol m(exp -2) s(exp -1)) for fens) and lower NEE at moderate and high light levels (P(sub max)= 5.2 micro mol m(exp -2) s(exp -1) for bogs and 10.8 micro mol m(exp -2) s(exp -1) for fens). As a single class, northern peatlands had much smaller ecosystem respiration (R = -2.4 micro mol m(exp -2) s(exp -1)) and NEE rates (alpha = 0.020 and P(sub max)= 9.2 micro mol m(exp -2) s(exp -1)) than the upland ecosystems (closed canopy forest, grassland, and cropland). Despite this low productivity, northern peatland soil carbon pools are generally 5-50 times larger than upland ecosystems because of slow rates of decomposition caused by litter quality and anaerobic, cold soils.
Since the beginning of the World Climate Research Program's Global Precipitation Climatology Project (GPCP) satellite remote sensing of precipitation has made dramatic improvements, particularly for tropical regions. Data from microwave and infrared sensors now form the most critical input to precipitation data sets and can be calibrated with surface gauges to so that the strengths of each data source can be maximized in some statistically optimal sense. It is clear however that there still remain significant uncertainties with satellite precipitation retrievals which limit their usefulness for many purposes. Systematic differences i'A tropical precipitation estimates have been brought to light in comparison activities such as the GPCP Algorithm Intercomparison Project and more recent Wetnet Precipitation Intercomparison Project 3. These uncertainties are assuming more importance because of the demands for validation associated with global climate modeling and data assimilation methodologies. The objective of the present study is to determine the physical basis for systematic differences in spatial structure of tropical precipitation as portrayed by several different satellite-based data sets. The study is limited to oceanic regions only and deals primarily with aspects of spatial variability. We are specifically interested in why MSU channel 1 and GPI precipitation differences are so striking over the Eastern Pacific ITCZ and why they both differ from other microwave emission-based precipitation estimates from SSM/I and a scattering-based deep convective ice index from MSU channel 2. Our results to date have shown that MSU channel I precipitation estimates are biased high over the Eastern Pacific ITCZ because of two factors: (1) the hypersensitivity of this frequency to cloud water in contrast to falling rain drops, and (2) unaccounted for scattering effects by precipitation-size ice which depresses the signal of the liquid water emission. Likewise, cold cloud top climatologies such as the GPI show an excess (a deficit) in estimated rainfall over the E. Pacific ITCZ (Warm Pool region). We show that these algorithms need to account for regionally varying heights (or temperatures) at which tropical convection detrains to form cirrus shields. A second objective we pursue is to identify variations in the macroscale cloud physical and thermodynamic properties of precipitation regimes" and relate these differences to tropical dynamical mechanisms of tropical heat and moisture balance. Finally, we interpret the algorithm differences and their associations with tropical dynamics in terms of WCRP GPCP goals for constructing precipitation climatologies.
Here, methane cold seep systems typically exhibit extensive buildups of authigenic carbonate minerals, resulting from local increases in alkalinity driven by methane oxidation. Here, we demonstrate that modern seep authigenic carbonates exhibit anomalously low clumped isotope values (Δ47), as much as ~0.2‰ lower than expected values. In modern seeps, this range of disequilibrium translates into apparent temperatures that are always warmer than ambient temperatures, by up to 50 °C. We examine various mechanisms that may induce disequilibrium behaviour in modern seep carbonates, and suggest that the observed values result from several factors including kinetic isotopic effects during methane oxidation, mixing of inorganic carbon pools, pH effects and rapid precipitation. Ancient seep carbonates studied here also exhibit potential disequilibrium signals. Ultimately, these findings indicate the predominance of disequilibrium clumped isotope behaviour in modern cold seep carbonates that must be considered when characterizing environmental conditions in both modern and ancient cold seep settings.
The pool of three Minus Eighty Laboratory freezer for ISS (MELFI) units continues providing the scientific community with robust and permanent freezer and refrigeration capabilities for life science experiments on the International Space Station (ISS). Launched in 2006, the first unit will complete, by summer 2013, seven years of continuous operations without intervention on the internal Nitrogen gas cycle, while all necessary hardware and operations were initially planned for preventive maintenance every two years. This unit has demonstrated outstanding performance on orbit and proved the technical decisions made during the development program. Current utilization of MELFI units in the ISS is taking full benefit of the initial specifications, which allows for wide adaptations to cope with the mission scenario imposed by the life extension in orbit. The two other MELFI units, launched respectively in 2008 and 2009, are supporting the first unit providing additional conditioned volume necessary for the science on board, and also for preparing thermal mass used to protect the samples on their way down to earth. The MELFI pool is outfitted with all supporting hardware to allow for extended operation on orbit including preventive and corrective maintenance. The internal components were designed to allow for easy on board maintenance. Spare equipment was installed in the MELFI rack on ISS and specific maintenance means were developed which required crew training before the cold gas cycle could be accessed. The paper will present first how the design choices made for the initial missions are identifying features necessary for extended duration missions, and will then give highlights on the utilization of the MELFI refrigeration pool during the recent years in ISS.