Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “close inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Tissue simulating gel for medical research

A tissue simulating gel and a method for preparing the tissue simulating gel are disclosed. The tissue simulating gel is prepared by a process using water, gelatin, ethylene gylcol, and a cross-linking agent. In order to closely approximate the characteristics of the type of tissue being simulated, other material has been added to change the electrical, sound conducting, and wave scattering properties of the tissue simulating gel. The result of the entire process is a formulation that will not melt at the elevated temperatures involved in hyperthermia medical research. Furthermore, the tissue simulating gel will not support mold or bacterial growth, is of a sufficient mechanical strength to maintain a desired shape without a supporting shell, and is non-hardening and non-drying. Substances were injected into the tissue simulating gel prior to the setting-up thereof just as they could be injected into actual tissue, and the tissue simulating gel is translucent so as to permit visual inspection of its interior. A polyurethane spray often used for coating circuit boards can be applied to the surface of the tissue simulating gel to give a texture similar to human skin, making the tissue simulating gel easier to handle and contributing to its longevity.

Companion, John A.↗

Tissue simulating gel for medical research

A tissue simulating gel and a method for preparing the tissue simulating gel are disclosed. The tissue simulating gel is prepared by a process using water, gelatin, ethylene glycol, and a cross-linking agent. In order to closely approximate the characteristics of the type of tissue being simulated, other material has been added to change the electrical, sound conducting, and wave scattering properties of the tissue simulating gel. The result of the entire process is a formulation that will not melt at the elevated temperatures involved in hyperthermia medical research. Furthermore, the tissue simulating gel will not support mold or bacterial growth, is of a sufficient mechanical strength to maintain a desired shape without a supporting shell, and is non-hardening and non-drying. Substances have been injected into the tissue simulating gel prior to the setting-up thereof just as they could be injected into actual tissue, and the tissue simulating gel is translucent so as to permit visual inspection of its interior. A polyurethane spray often used for coating circuit boards can be applied to the surface of the tissue simulating gel to give a texture similar to human skin, making the tissue simulating gel easier to handle and contributing to its longevity.

Companion, John A.↗

Design of a High-Pressure Fuel System for Use with Dimethyl Ether

The paper documents the modeling and experimental work on a common rail fuel injection system for Dimethyl Ether, a potential diesel substitute with a low carbon intensity signature. The DME fuel system is deployed on a light duty 2.2L compression ignition engine. The paper describes the injector optimization to shift to higher flows to account for the lower heating value and density of the DME when compared to diesel. The type of the injection system used for the DME application is an advanced rendering of the Common rail noted for a one-piece piston-needle injector construction and a solenoid driven spill valve featuring a pressure balanced poppet. A dedicated high-pressure fuel pump designed to pressurize DME is used. The design results in a fast acting open and close injection event, reduced leakage, with reduced cavitation in the fuel injector volume. Design parameters for system optimization included fill and spill orifices, needle lift, bias spring, and injector hole size. The design model provides good correlation of the instantaneous rates of injection with experiments across a wide range of pressure and injection timings. Proposed performance milestones for the design included similar DME injection duration to the diesel counterpart for same fuel energy injected into the cylinder to retain high engine cycle efficiency. Here, the dedicated DME design provided reduced hydraulic delays of 50%. Tests demonstrated sustained operation at pressures of 1000 bar, with capability to reach 1500bar. Durability tests showed no cavitation-deterioration over a 200-hour test cycle by means of spray imaging and hardware inspection.

De Ojeda, William [WM International Engineering, L↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Examining Weathering of Magnesite in an Arid Environment: Implications For Jezero Crater

Introduction:Orbiter data indicatethe presence of carbonates in severallocations on the surface of Mars[1],but Jezero crater, landing site of the Perseverancerover,is the only known location where carbonatesap-pear coincident with evidence of fluvialand lacustrineactivity [2].On Earth, carbonates in close proximity to these paleoenvironments mayindicatethe presence of past microbial life,like stromatolites[3], that could re-sult inbiosignatures [2]. However,in other cases,car-bonates can also form throughthe alteration of mafic materialwiththe introductionof carbonic acid[4].Hy-drated magnesites have also been found in evaporative environments along lake shores, and in playas[5,6,7].Correctly interpreting past carbonates on Mars is there-fore critical in the search for past signs of life. In Jezero crater,both thenorthernand western fans haveMg-rich carbonates intermixed with olivine-rich material[8].According to CRISM data, magnesite(MgCO3), along with hydromagnesite(Mg5(CO3)4(OH)2•4H2O), arepotential candidatesfor these Mg-carbonates [2]. Considering the spatial con-text with olivine,there aremultiplepotential explana-tions for the presence ofMg-carbonatesin this locationincludingin-situformation via alterationof olivine-rich materialwith carbonic acid,transportationfrom farther up in the watershed, or precipitation of lacustrine car-bonates[2]. The formation of hydromagnesite rather than magnesite is favored when Mg2+saturated solutions have a high CO32-/HCO3-ratio, which, on Earth, is thought to be caused byinflow of groundwater [4]. Additionally, Mg-carbonates tend to precipitate under high pH condi-tions and are unstable at lower pH conditions [5]. Hy-dromagnesite is stable at atmospheric CO2pressure and temperature conditions common to most Earth surface environments [9]. However, it is subject to transfor-mation to magnesite after dehydration and concomitant brucite formation or dissolution and reprecipitation [10].Previousresearch suggests that hydrated car-bonates, including hydromagnesite, can formas weath-ering productsof mafic minerals in the presenceof H2O and CO2in subfreezing temperatures and would not de-hydrate under Martian atmospheric conditions [11,12].It is critical to understand the formation conditions of Mg-carbonatesbecause of the different implications for the past history of Martian environments. Therefore, in this work we are investigating the weathering of Mg-carbonatesin arid environments to helpbetter understand Mg-carbonates in Jezero crater. Study Area:The Ala-Mar Mines(East and West)near Ely, NVare the site ofmultiple magnesitedepositsfound within a calcareous tuff formationthat overlies Tertiary aged volcanic rocks.Here,magnesiteis formed via the alteration of the calcareous tuff and occurs innodules, veins,and lenses[13]. Previous work suggests magnesite deposits are associated with faults [13]. Within the West Mine, magnesite can be found in two maincontexts: (1) relatively circular zones of cauli-flower-like material found within (2) a more massivelensthat is heavily fractured on the surface.Methods.Samplesof both the cauliflower texture and more massive materialwere collectedat Ala Mar West Mine. Both samples were thenpowdered, sieved and analyzed with an inXitu Terra Portable XRD. The program QualX was used to identify potential mineral phases [14].Both samples were also optically inspected using 10x and 20x hand lenses.Figure 1. XRD patterns for the cauliflower magnesite (top) and massive magnesite (bottom). Ongoing and future work on the samples discussed above includes scanning electron microscopy (SEM), electron microprobe analysis (EMPA), and near-infra-red spectroscopy to determine whether hydromagnesite is present. Separation and analysis of the clay-size frac-tionby XRD will helpto better identify any phyllosili-cate phases present. Results and Discussion:Both textures are a white to light tan with a porcelain luster on weathered sur-faces, along with minor iron staining in some areas. Likewise, both textures are white with a porcelain luster on fresh surfaces. When broken apart, the massive mag-nesite shows macroscopic crystals, unlike the cauli-flower magnesite. XRD analysis shows that both samples have high concentrationsof magnesite with lesser amounts of thecarbonatemineral huntite(Mg3Ca(CO3)4; Figure1).The more massive samplecontainsa serpentine-groupmineral,with lizardite being apotential candidate. The cauliflower sample has several minor peaks that may correspond to hydromagnesite(Figure 1), although more work is needed to confirm this.Additionally, thecauliflower deposits closely resemble hydromagnesite deposits found in southwestern Turkey, formed via mi-crobialites[15].As such, it is likely that moreaqueous alterationor weatheringis occurring at the locations where the cauliflower magnesite is present. However, additional field work will need to be conducted to con-firm this hypothesis. Conclusions and Future Work:Future work will include field mapping of fault locations andadditional samplingof the different magnesite types as well as of the calcareous tuffmaterial.We will also look specifi-cally for potential weathering products of magnesite in this arid location, which may yield important insight into the Mg-carbonates located in Jezero crater. XRD analyses on aPANalytical XRDusing non-ambient stages will be used to investigate the stability of hydro-magnesiteat different humiditiesand temperatures, which has implications for samples to bereturned to Earth in the future. Additionally, thermal and evolved gas analysis of magnesite and hydromagnesite will be compared to results from Gale Craterto help interpret the mineralogy inthat location[16]. The results of this research will further ourunderstanding of carbonate for-mationin volcanic settingsandtheirweathering pro-cessesin arid environments. Acknowledgments:We acknowledge funding for this research from Jacobs Technology at the Johnson Space Center.We would also like to thank Ngoc Luu, Christopher Adcock, Richard Allanson, and the rest of the UNLV Soil Science Teamfor their continued sup-portwith troubleshooting and otherlab work. References:[1] Ehlmann, B.L., and Edwards, C.S. (2014) Annual Review of Earth and Planetary Sci., 42, 291–315. [2] Horgan, B.H.N., et al. (2020) Icarus, 339, 113526. [3] Bosak, T., et al. (2013) Annual Review of Earth and Planetary Sci, 41, 21–44. [4] Pohl, W.L. (1989) Gebriider Borntraege, 28, 1-13. [5] Müller, G., et al. (1972) Die Naturwissenschaften, 59, 158–164. [6] Walter, M.R., et al. (1973) Journal of Sedimentary Pe-trology, 43, 1021–1030. [7] Braithwaite, C.J.R., and Zedef, V. (1994) Sedimentary Geology, 92, 1–5. [8] Goudge, T.A., et al. (2015) JGR: Planets, 120, 775–808. [9] Langmuir, D. (1965) Journal of Geology, 73, 730–754. [10] Zhang, P., et al. (2000) Applied Geo-chem., 286, 1748–1753. [11] Calvin, W.M., et al. (1994) JGR, 99, 14659-14675. [12]Russell, M.J., et al. (1999) Journal of the Geological Society of London, v. 156, p. 869–888. [13] Faust, G.T., and Callaghan, E. (1948) GSA Bulletin, 59, 11–74. [14] Altomare, A., et al. (2015) J. of Applied Crystallography, 48, 598–603. [15] Zedef, V.,et al. (2000) Economic Geology, 95, 429–445. [16] Leshin, L.A. et al., (2013) Science, 341, 1–9

A W Provow↗

Damage Detection and Self-Repair in Inflatable/Deployable Structures

Inflatable/deployable structures are under consideration for applications as varied as expansion modules for the International Space Station to destinations for space tourism to habitats for the lunar surface. Monitoring and maintaining the integrity of the physical structure is critical, particularly since these structures rely on non-traditional engineering materials such as fabrics, foams, and elastomeric polymers to provide the primary protection for the human crew. The closely related prior concept of monitoring structural integrity by use of built-in or permanently attached sensors has been applied to structures made of such standard engineering materials as metals, alloys, and rigid composites. To effect monitoring of flexible structures comprised mainly of soft goods, however, it will be necessary to solve a different set of problems - especially those of integrating power and data-transfer cabling that can withstand, and not unduly interfere with, stowage and subsequent deployment of the structures. By incorporating capabilities for self-repair along with capabilities for structural health monitoring, successful implementation of these technologies would be a significant step toward semi-autonomous structures, which need little human intervention to maintain. This would not only increase the safety of these structures, but also reduce the inspection and maintenance costs associated with more conventional structures.

Brandon, Erik↗

The NASA JSC Hypervelocity Impact Technology (HVIT) Office

The Hypervelocity Impact Technology (HVIT) office at the National Aeronautical and Space Administration (NASA) Johnson Space Center (JSC) is dedicated to support NASA flight programs in meeting their meteoroid and orbital debris (MMOD) protection requirements both efficiently and effectively, with a minimum of shielding mass, volume, and cost. This paper provides an overview of HVIT capabilities in providing hypervelocity tests, analyses, MMOD risk assessments and shielding expertise. HVIT personnel work closely with NASA program and safety/mission assurance personnel to develop program-specific MMOD protection requirements which are both achievable based on initial risk assessments and will meet overall safety and mission success requirements. HVIT then proceeds with hypervelocity impact testing and hydrocode assessments to update and verify ballistic limit equations used in the MMOD risk assessment. Hypervelocity impact tests are primarily performed at the NASA WSTF Remote Hypervelocity Test Laboratory (RHTL). Other hypervelocity facilities that provide complementary test capabilities are called on when necessary to fill data gaps. The goal of the final pre-flight MMOD risk assessment is to show compliance with MMOD requirements prior to flight. This final assessment will also incorporate changes in the MMOD environment from meteoroid showers and orbital debris breakups. After the mission is flown, post-flight inspections are performed by HVIT to document and trend MMOD damage to returned spacecraft surfaces and hardware. HVIT accomplishments in NASA mission support are described. In addition, current HVIT activities to aid on-going NASA crewed missions and science missions are presented.

Meteoroid↗

ASME Code Rules and ASTM Standards Integration for Ceramic Composite Core Materials and Components 1

Fiber-reinforced ceramic matrix composites have many desirable properties for high-temperature nuclear applications, including excellent thermal and mechanical properties and reasonable to outstanding radiation resistance. Over the last 20 years, the use of ceramic composite materials has already expanded in many commercial nonnuclear industries as fabrication and application technologies mature. The new ASME design and construction rules under Section III, Subsection HH, Subpart B lay out the requirements and criteria for materials, design, machining and installation, inspection, examination, testing, and the marking procedure for ceramic composite core components, which is similar to the established graphite code under Section III, Subsection HH, Subpart A. Moreover, the general requirements listed in Section III, Subsection HA, Subpart B are also expanded to include ceramic composite materials. The code rules rely heavily on the development and publication of standards for composite specification, classification, and testing of mechanical, thermal, and other properties. These test methods are developed in the American Society for Testing and Materials Committee C28 on Advanced Ceramics with a current focus on ceramic composite tubes. Details of the composites code, design methodology, and similarities to the graphite code, as well as guidance for the development of specifications for ceramic composites for nuclear application and recent standard developments, are discussed. The next step is to "close the gap" to support licensing aspects by validating the code with benchmarking data.

Geringer, Josina↗

(abstract) Characterization of Structural Response for Systems with Loose Joints

This paper describes a technique to locate and characterize loose joints in a large truss structure to generate an accurate structural model. The joint looseness is modeled as a gap in the member that opens and closes depending on the loading. Arbitrarily placed actuators are used to prestress the structure to first linearize the response. Next the actuator displacements are systematically reduced while monitoring the displacement response. The gap locations are determined by comparing the measured displacements with sets of calculated displacements and the sizes are estimated by monitoring the gap member length changes using the appropriate linear force-displacement relationship for the load level. The effect of measurement error in the truss displacements and the actuator length changes are investigated.

truss structures loose joints displacements actuat↗

High Pressure Vent Line Mishap: Investigation Summary

During testing on the E-1 Test Stand, the High Pressure (HP) Liquid Hydrogen (LH) vent line was displaced off its supports, damaging the expansion joints (EJ), piping, and pipe supports of the line. The damage to the vent line is believed to have occurred during Cell 3 testing on Thursday, September 21, during the first test of the day. The fuel systems being used for Cell 3 testing are connected to the LP and HP LH Vent systems and are being used in Liquid Natural Gas (LNG) service. The Cell 3 interface bleed valve that discharges to the HP LH Vent system was inadvertently left at 100% open during the chill-in process for longer than the typical amount of time. Since this valve is usually at a lower set point or intermittently closed during the chill-in process, more than the typical amount of LNG flowed into the vent line as pre-test procedures continued as normal. The open bleed valve was noticed before test preparations were completed and prior to refilling of the HP LH Tank before test. The test sequence was started, run, and shutdown normally. Video of the flare stack showed an atypical discharge of liquid at the flare stack exit. Pressure downstream of the Cell 3 interface bleed valve (a valve connected to the southernmost part of the vent system) spiked to a higher-than-normal level. No evidence of damage was captured at the time of the event. The system was used in a typical fashion after the event and for 4 subsequent tests on Thursday and Friday, before the damage was observed. A drive-by inspection of the flare stack was performed on Friday (September 22nd) morning before sunrise and before test activities began, but no damage of the vent line was observed at that time. No abnormal system behavior was observed during testing on Friday. The damage was discovered and reported to NASA Test Operations on Monday, initiating the Incident Response Team. The Mishap appointment letter was issued September 27th to formally initiate the Mishap Investigation.

LNG↗

Investigation of MMOD Impact on Shuttle Payload Bay Door Radiator

Post flight inspections on the Space Shuttle Atlantis conducted after the STS-115 mission revealed a 0.11 inch (2.8 mm) hole in the outer facesheet of the starboard payload bay door radiator panel #4. This hole is the possible result of micrometeoroid/orbiting debris (MMOD) impact. The payload bay door radiators in this region are 0.5 inch (12.7 mm) thick aluminum honeycomb with 0.011 in (0.279 mm) thick aluminum facesheets topped with 0.005 in (0.127 mm) silver-Teflon tape. Inner facesheet damage included a 0.267 in (6.78 mm) long through crack with measurable deformation in the area of 0.2 in (5.1 mm). There was also a 0.031 in (0.787 mm) diameter hole in the rear facesheet. A large approximately 1 in (25 mm) diameter region of honeycomb was also destroyed. Since the radiators are located on the inside of the shuttle payload bay doors which are closed during ascent and reentry, the damage could only have occurred during the on-orbit portion of the mission. This paper will document the data collected from the impact site and will include results of the SEM/EDX analysis. Evidence will be presented that suggests a source of the impact as well as an analysis of the impact site features that indicate projectile directionality. Results of hypervelocity impact testing on representative samples in an attempt to simulate the impact event will be presented and discussed. Finally, the results of a study showing the regions of the orbiter vehicle that would be vulnerable to an equivalent projectile will be given.

Hyde, J. L.↗

Nuclear Thermal Propulsion Ground Test History

Nuclear Thermal Propulsion (NTP) was started in ~1955 under the Atomic Energy Commission as project Rover and was assigned to Los Alamos National Laboratory. The Nevada Test Site was selected in 1956 and facility construction began in 1957. The KIWI-A was tested on July 1, 1959 for 5 minutes at 70MW. KIWI-A1 was tested on July 8, 1960 for 6 minutes at 85MW. KIWI-A3 was tested on October 10, 1960 for 5 minutes at 100MW. The National Aeronautics and Space Administration (NASA) was formed in 1958. On August 31, 1960 the AEC and NASA established the Space Nuclear Propulsion Office and named Harold Finger as Director. Immediately following the formation of SNPO, contracts were awarded for the Reactor In Flight Test (RIFT), master plan for the Nuclear Rocket Engine Development Station (NRDS), and the Nuclear Engine for Rocket Vehicle Application (NERVA). From December 7, 1961 to November 30, 1962, the KIWI-B1A, KIWI-B1B, and KIWI-B4A were tested at test cell A. The last two engines were only tested for several seconds before noticeable failure of the fuel elements. Harold Finger called a stop to any further hot fire testing until the problem was well understood. The KIWI-B4A cold flow test showed the problem to be related to fluid dynamics of hydrogen interstitial flow causing fuel element vibrations. President Kennedy visited the NTS one week after the KIWI-B4A failure and got to see the engine starting to be disassembled in the maintenance facility. The KIWI-B4D and KIWI-B4E were modified to not have the vibration problems and were tested in test cell C. The NERVA NRX program started testing in early 1964 with NRX-A1 cold flow test series (unfueled graphite core), NRX-A2 and NRX-A3 power test series up to 1122 MW for 13 minutes. In March 1966, the NRX-EST (Engine System Test) was the first breadboard using flight functional relationship and total operating time of 116 minutes. The NRX-EST demonstrated the feasibility of a hot bleed cycle. The NRX-A5 had multiple start-ups in May-June 1966 with 30.75 minutes accumulative operating time at or above 1GW. The NRX-A6 was tested in December 1969 and ran for 62 minutes at 1100 MW. Each engine had post-test examination and found various structure anomalies which were identified for correction and the fuel element corrosion rate was reduced. The Phoebus series of research reactors began testing at test cell C, in June 1965 with Phoebus 1A. Phoebus 1A operated for 10.5 minutes at 1100 MW before unexpected loss of propellant and leading to an engine breakdown. Phoebus 1B ran for 30 minutes in February of 1967. Phoebus 2A was the highest steady state reactor built at 5GW. Phoebus 2A ran for 12 minutes at 4100 MW demonstrating sufficient power is available. The Peewee test bed reactor was tested November- December 1968 in test cell C for 40 minutes at 500MW with overall performance close to pre-run predictions. The XE' engine was the only engine tested with close to a flight configuration and fired downward into a diffuser at the Engine Test Stand (ETS) in 1969. The XE' was 1100 MW and had ~28 start-ups. The nuclear furnace NF-1 was operated at 44 MW with multiple test runs at 90 minutes in the summer of 1972. The NF-1 was the last NTP reactor tested. The Rover/NERVA program was cancelled in 1973. However, before cancellation, a lot of other engineering work was conducted by Aerojet on a 75, 000 lbf prototype flight engine and by Los Alamos on a ~16,000 lbf "Small Engine" nuclear rocket design. The ground test history of NTP at the NRDS also offers many lessons learned on how best to setup, operate, emergency shutdown, and post-test examine NTP engines. The reactor and engine maintenance and disassembly facilities were used for assembly and inspection of radioactive engines after testing. Most reactor/ engines were run at test cell A or test cell C with open air exhaust. The Rover/NERVA program became aware of a new environmental regulation that would restrict the amount of radioactive particulates allowed to be release in open air and successfully demonstrated a scrubber concept with the NF-1. The ETS stand was the only one with a high altitude test chamber used for XE'. The ETS and other test cells showed the effects the engine's radiation had on the facility materials and instrumentation as well as side effects the ground test facility has back on the engine operation. The breakdown of Phoebus 1A at test cell C showed how the site was cleaned up and back to operation for five more engines before the program was cancelled.

Gerrish, Harold P.↗

Hyperspectral Imager-Tracker

The Hyperspectral Imager-Tracker (HIT) is a technique for visualization and tracking of low-contrast, fast-moving objects. The HIT architecture is based on an innovative and only recently developed concept in imaging optics. This innovative architecture will give the Light Prescriptions Innovators (LPI) HIT the possibility of simultaneously collecting the spectral band images (hyperspectral cube), IR images, and to operate with high-light-gathering power and high magnification for multiple fast- moving objects. Adaptive Spectral Filtering algorithms will efficiently increase the contrast of low-contrast scenes. The most hazardous parts of a space mission are the first stage of a launch and the last 10 kilometers of the landing trajectory. In general, a close watch on spacecraft operation is required at distances up to 70 km. Tracking at such distances is usually associated with the use of radar, but its milliradian angular resolution translates to 100- m spatial resolution at 70-km distance. With sufficient power, radar can track a spacecraft as a whole object, but will not provide detail in the case of an accident, particularly for small debris in the onemeter range, which can only be achieved optically. It will be important to track the debris, which could disintegrate further into more debris, all the way to the ground. Such fragmentation could cause ballistic predictions, based on observations using high-resolution but narrow-field optics for only the first few seconds of the event, to be inaccurate. No optical imager architecture exists to satisfy NASA requirements. The HIT was developed for space vehicle tracking, in-flight inspection, and in the case of an accident, a detailed recording of the event. The system is a combination of five subsystems: (1) a roving fovea telescope with a wide 30 field of regard; (2) narrow, high-resolution fovea field optics; (3) a Coude optics system for telescope output beam stabilization; (4) a hyperspectral-mutispectral imaging assembly; and (5) image analysis software with effective adaptive spectral filtering algorithm for real-time contrast enhancement.

Agurok, Llya↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Developmental testing resulting in a simplified liquid oxygen check valve for the Space Shuttle Main Propulsion System

The coil spring in a Space Shuttle liquid oxygen check valve failed due to cyclic fatigue in September, 1991. The dual-flapper, swing check valve is used to prevent reverse flow to the Space Shuttle Main Engines. Upon inspection of the failed component, the spring tangs were found to be missing and heavy wear was observed on the inner diameter of the spring coils. The fracture surfaces revealed that the metal had been steadily worn away until a simple overload caused the final fracture. A series of flow tests using water and a water/gas mixture was conducted to identify the flow phenomenon which produced the cyclic wear. A Plexiglas outlet housing was utilized to view the flapper behavior under different flow conditions and to aid in high speed photography. The tests revealed that flow instabilities induced two oscillatory flapper responses: a rocking mode and a chattering mode. Initially, attempts were made to reduce the spring-flapper oscillations. However, the final solution to the problem was a springless configuration which satisfied the valve's design requirements and eliminated the oscillations. The springless design relied on the inherent ability of the reverse flow momentum to close the flappers.

Aber, Gregory S.↗

The Plasma Wave Environment of Europa

The Galileo spacecraft has executed nine close flybys of Jupiter's moon Europa for which plasma wave observations were obtained. This paper presents an analysis of the observations from these flybys taking into consideration the variable geometry of the trajectories in an attempt to characterize the general plasma-wave environment associated with the interaction of the Jovian magnetosphere with the moon. A wide variety of plasma-wave phenomena are found to be associated with this interaction. While there are apparently temporal variations which complicate the analysis, a crude model of the distribution of these phenomena around Europa is derived. Primarily on the upstream side of Europa, and working inward to the moon, electron-cyclotron harmonics are first observed, followed by a region within about two Europa radii of the moon with whistler-mode hiss or chorus, and culminating in a region closest to the moon where a band at the upper hybrid resonance frequency is sometimes enhanced over its ambient intensity. The wake region is approximately two Europa radii across and comprises a broadband, highly variable, and bursty electrostatic phenomenon. Upon closer inspection, these bursty emissions appear as solitary structures similar to those in Earth's auroral zone and plasma sheet boundary layer. In addition to the survey of wave phenomena in the vicinity of Europa, we provide density profiles derived primarily from the upper hybrid resonance frequency which is readily apparent throughout most of each of the flybys. Finally, we suggest that the whistler mode, electron cyclotron harmonic, and upper hybrid resonance emissions are driven by some combination of factors including variations in the magnetic field near Europa and the loss and production of plasma at Europa as a result of the interaction of the Jovian magnetosphere with the moon. By analogy with studies of the ion and electron holes and broadband electrostatic noise at Earth and Jupiter, we argue that the electrostatic solitary structures in the wake are associated with currents and beams coupling Europa to Jupiter's ionosphere.

Kurth, W. S.↗

Second-Generation Six-Limbed Experimental Robot

The figure shows the LEMUR II - the second generation of the Limbed Excursion Mechanical Utility Robot (LEMUR), which was described in "Six-Legged Experimental Robot" (NPO-20897), NASA Tech Briefs, Vol. 25, No. 12 (December 2001), page 58. The LEMUR II incorporates a number of improvements, including new features, that extend its capabilities beyond those of its predecessor, which is now denoted the LEMUR I. To recapitulate: the LEMUR I was a six-limbed robot for demonstrating robotic capabilities for assembly, maintenance, and inspection. The LEMUR I was designed to be capable of walking autonomously along a truss structure toward a mechanical assembly at a prescribed location and to perform other operations. The LEMUR I was equipped with stereoscopic video cameras and image-data-processing circuitry for navigation and mechanical operations. It was also equipped with a wireless modem, through which it could be commanded remotely. Upon arrival at a mechanical assembly, the LEMUR I would perform simple mechanical operations with one or both of its front limbs. It could also transmit images to a host computer. Each of the six limbs of the LEMUR I was operated independently. Each of the four rear limbs had three degrees of freedom (DOFs), while each of the front two limbs had four DOFs. The front two limbs were designed to hold, operate, and/or be integrated with tools. The LEMUR I included an onboard computer equipped with an assortment of digital control circuits, digital input/output circuits, analog-to-digital converters for input, and digital-to-analog (D/A) converters for output. Feedback from optical encoders in the limb actuators was utilized for closed-loop microcomputer control of the positions and velocities of the actuators. The LEMUR II incorporates the following improvements over the LEMUR I: a) The drive trains for the joints of the LEMUR II are more sophisticated, providing greater torque and accuracy. b) The six limbs are arranged symmetrically about a hexagonal body platform instead of in straight lines along the sides. This symmetrical arrangement is more conducive to omnidirectional movement in a plane. c) The number of degrees of freedom of each of the rear four limbs has been increased by one. Now, every limb has four degrees of freedom: three at the hip (or shoulder, depending on one s perspective) and one at the knee (or elbow, depending on one s perspective). d) Now every limb (instead of only the two front limbs) can perform operations. For this purpose, each limb is tipped with an improved quick-release mechanism for swapping of end-effector tools. e) New end-effector tools have been developed. These include an instrumented rotary driver that accepts all tool bits that have 0.125-in. (3.175-mm)-diameter shanks, a charge-coupled-device video camera, a super bright light-emitting diode for illuminating the work area of the robot, and a generic collet tool that can be quickly and inexpensively modified to accept any cylindrical object up to 0.5 in. (12.7 mm) in diameter. f) The stereoscopic cameras are mounted on a carriage that moves along a circular track, thereby providing for omnidirectional machine vision. g) The control software has been augmented with software that implements innovations reported in two prior NASA Tech Briefs articles: the HIPS algorithm ["Hybrid Image-Plane/Stereo Manipulation" (NPO-30492), Vol. 28, No. 7 (July 2004), page 55] and the CAMPOUT architecture ["An Architecture for Controlling Multiple Robots" (NPO-30345), Vol. 28, No. 10 (October 2004), page 65].

Kennedy, Brett↗

Ensemble Manufacturing Techniques for Steam Turbine Components Across Length Scales

Faster design to manufacturing requirements were sought for steam turbine components to meet the changing demands of today’s power grid of improved efficiency through operating temperature increases and enhanced operational flexibility from baseload to cyclic operations. Advances in multiple advanced manufacturing (AM) process enabled redesign of turbine components for extreme environments with the potential to reduce cost. AM is of particular interest to improve component functionality, higher temperature capability, and superior durability in large scale steam turbine applications. AM methods have an immense potential to open-up the design space by working directly with the 3D model to produce near-net shapes, enable fast design-manufacturing iterations, thereby significantly reducing product cost and lead-time up to 25 % from current baseline. However, these benefits cannot be fully realized due to the potential for unknown AM processing defects and their resultant effect upon component performance in service. Siemens is partnering with Oak Ridge National Laboratory (ORNL), Electric Power Research Institute (EPRI), and Connecticut Center for Advanced Technology (CCAT) to advance the knowledge of complex process-material interactions for desired microstructures and properties that are closely interlinked to component geometries across different length scales. The proposed program utilized an ensemble of multidisciplinary technologies to accelerate the development of materials, high-throughput experiments for their qualification, and design flexibility/topology optimization for repair/redesign of components to address critical failure mechanisms for improved performance and increased reliability of existing power plant components. The proposed activities, if successfully demonstrated for identified components, will enable paradigm shift in customized manufacturing and accelerated qualification/certification towards increased steam turbine component durability, increased turbine efficiency, and reduced CO 2 emissions in load-following environments compared to today’s technology. Technology maturation is built into the project as successful research will include customized process-component down-selection enabling AM methodologies to be incorporated directly into the existing supply chain. The specific activities of the proposed effort are: 1. Topology optimization of down-selected steam turbine parts that are amenable to additive and hybrid manufacturing for cost/performance improvement. 2. Process-structure-property relationships for five AM processes for steam turbine materials of interest to compare with conventional materials. 3. Perform part/assembly build process using advanced additive/hybrid machine tools followed by quality inspection of the built components for insight into qualification for production scale-up. Steam turbine rig testing of printed components under targeted, well monitored and characterized environmental conditions of for performance comparison of baseline and redesigned components.

36 MATERIALS SCIENCE↗