Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clean electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Machine Learning-Accelerated First-Principles Molecular Dynamics Explains Anomalous Lattice Thermal Expansion in BaZr 0.78 Y 0.22 O 3-δ

Fuel cells are a vital clean energy technology that converts chemical energy directly into electricity with high efficiency, making them a cornerstone of a sustainable energy future. Herein we investigate the thermal and chemical lattice expansion behavior of hydrated BaZr 0.78 Y 0.22 O 3-δ using machine learning-accelerated ab initio molecular dynamics simulations. Here, our results reproduce the experimentally observed non-monotonic and anomalous temperature dependence of lattice expansion, which we attribute to the competing effects of thermal expansion and dehydration—two mechanisms that influence the lattice expansion in opposite directions. The importance of this work lies in its detailed demonstration of how advanced computational techniques can accurately capture complex environmental effects, providing a valuable framework for modeling similar phenomena in a variety of material systems and applications.

Proton conducting fuel cell↗

Thermal transport in compensated semimetals: Effect of electron-electron scattering on Lorenz ratio

It is well known that the electronic thermal conductivity of clean compensated semimetals can be greatly enhanced over the electric conductivity by the availability of an ambipolar mechanism of conduction, whereby electrons and holes flow in the same direction experiencing negligible Coulomb scattering as well as negligible impurity scattering. This enhancement—resulting in a breakdown of the Wiedemann-Franz law with an anomalously large Lorenz ratio—has been recently observed in two-dimensional monolayer and bilayer graphene near the charge neutrality point. In contrast to this, three-dimensional compensated semimetals such as WP 2 and Sb are typically found to show a reduced Lorenz ratio. Here, we investigate the reasons for this difference, focusing on the low-temperature regime where the electron-electron scattering is expected to dominate over other scattering mechanisms. We show that the different regimes of Fermi statistics (nondegenerate electron-hole liquid in graphene versus degenerate electron-hole liquid in compensated semimetals) are not sufficient to explain the reduction of the Lorenz ratio in the latter. We propose that the solution of the puzzle lies in the large separation of electron and hole pockets in momentum space, which allows compensated semimetals to sustain sizable regions of electron-hole accumulation near the contacts. These accumulations suppress the ambipolar conduction mechanism and effectively split the system into two independent electron and hole conductors. We present a quantitative theory of the crossover from ambipolar to unipolar conduction as a function of the size of the electron-hole accumulation regions, and show that it naturally leads to a sample-size-dependent thermal conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ground state of Ce 3 Bi 4 Pd 3 unraveled by hydrostatic pressure

Noncentrosymmetric Ce 3 Bi 4 Pd 3 has attracted a lot of attention as a candidate for strongly correlated topological material, yet its experimental ground state remains a matter of contention. Two conflicting scenarios have emerged from a comparison to the prototypical Kondo insulator Ce 3 Bi 4 Pd 3 : Either Ce 3 Bi 4 Pd 3 is a spin-orbit-driven topological semimetal or a Kondo insulator with smaller Kondo coupling than its Pt counterpart. Here, we determine the ground state of Ce 3 Bi 4 Pd 3 via electrical resistivity measurements under hydrostatic pressure, which is a clean symmetry-preserving tuning parameter that increases hybridization but virtually preserves spin-orbit coupling. Ce 3 Bi 4 Pd 3 becomes more insulating under pressures up to 2.3 GPa, which is a signature of Ce-based Kondo insulating materials in the considered pressure range. Its small zero-pressure gap increases quadratically with pressure, similar to the behavior observed in the series Ce 3 Bi 4 (Pt 1 - x Pd x ) 3 , which indicates that Pt substitution and applied pressure have a similar effect. Finally, our result not only demonstrates that Kondo coupling, rather than spin-orbit coupling, is the main tuning parameter in this class of materials, but it also establishes that Ce 3 Bi 4 Pd 3 has a narrow-gap Kondo insulating ground state.

36 MATERIALS SCIENCE↗

NREL Support to Louisville Metro Government [Slides]

This slide deck summarizes a project in which NREL is providing support to the Louisville Metro Government regarding efforts to achieve a 100% renewable electricity goal for municipal operations.

100% clean energy target↗

Introducing Small Scale Waste-to-Energy Technology in Microgrids (Cooperative Research and Development Final Report, CRADA Number CRD-17-00703)

Cogent has developed an innovative, proprietary waste-to-energy (WTE) system, the HelioStorm(TM) Gasifier, capable of efficiently operating on small amounts of heterogeneous municipal solid waste feedstocks, converting them into a clean syngas that can be used to fuel an electricity generator, all with rapid on/off cycle times. NREL will work with Cogent to complete a computer simulation of an integrated HelioStorm(TM) plasma gasifier system and dual fuel diesel generator. Cogent will test the performance of an actual HelioStorm(TM) WTE system and dual fuel diesel generator at their test facility using steady state electrical loads and provide a report describing the performance of the integrated system.

09 BIOMASS FUELS↗

Extremely Durable Concrete using Methane Decarbonization Nanofiber Co-products with Hydrogen

This project successfully developed a scalable, low-cost co-production process for hydrogen (H₂) and carbon nanofibers (CNFs) using methane through catalytic chemical vapor deposition (CVD). CNFs are high-value materials with exceptional mechanical, electrical, and chemical properties, while hydrogen is a critical clean energy resource. By leveraging vapor deposition to create highly dispersed metal catalysts, this work addressed the dual challenge of producing low-cost hydrogen and enhancing the durability of concrete using co-produced CNFs. Unlike prior approaches, which required separating the carbon product from the catalyst, this innovative method integrated the carbon product, catalyst, and silica support as a crack-bridging additive for Portland cement. This novel application aimed to advance the performance of high-performance concrete (HPC) by improving its flexural toughness, durability, and resistance to environmental degradation.

08 HYDROGEN↗

Clean Cities and Communities Partnership 2023 Activity Report

This is the 2023 report for the Clean Cities and Communities (CC&C) partnership. It tracks the metrics that have been reported by individual coalitions and aggregated to the national level. It looks at the various outreach activities, grant activities, and implementation of clean transportation technologies. Such technologies include natural gas vehicles, electric vehicles, propane vehicles, hydrogen fuel cell vehicles, biodiesel, ethanol, idle reduction technologies, fuel economy improvement technologies, vehicle-miles-traveled reduction technologies, and off-road technologies. The CC&C partnership had an energy use impact of over 1 billion gallons in 2023 and reduced emissions by nine million tons. Outreach, engagement, and training activities increased 18% from last year.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Achieving Economy-wide Net-Zero Solutions: The Essential Role of Nuclear Energy

The Biden administration has committed to full decarbonization of the U.S. electricity grid by 2035 and economy-wide net zero emissions by 2050. These aggressive goals demand immediate action if we are to be successful, and they require us to think more holistically about our clean energy options. Programs within the Department of Energy are addressing these holistic solutions. Traditionally, electricity generation and management and meeting energy demands for industry and transportation are considered independently. As we seek to achieve net zero, we need to reassess our energy demands. When we consider overall energy use, only one-third is in the form of electricity. Additional energy demands are in the form of heat or steam for industrial processes, as well as transportation. These sectors are much harder to abate, and electrification may not be the best option. Reducing environmental emissions at an affordable cost, while maintaining grid reliability and resilience, will require us to use all of the clean energy resources that we have available. That means coordinating the use of nuclear, renewables, and fossil fuels with carbon capture to meet growing demands for electricity, industrial applications, and mobility. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. This presentation will highlight advanced nuclear technologies under development today and will provide a glimpse into the wide array of R&D being conducted across multiple DOE-funded programs.

08 HYDROGEN↗

A Power Take-Off (PTO) for Wave Energy Converters Based on the Hybrid Hydraulic-Electric Architecture (HHEA)

Wave energy is a promising renewable energy resource for coastal regions around the world, but is not yet an economically competitive source of electricity. More effective power take-off (PTO) designs would help to make wave power a feasible and clean source of energy. To do this, PTOs need to: i) enable controlled actuation, ii) convert absorbed energy into electricity efficiently, and iii) have minimal manufacturing costs. We propose a new PTO architecture that can exert arbitrary control loads on the WEC to maximize energy capture, enabling the downsizing of expensive electrical components while maintaining high efficiency. Our PTO design is based upon a hybrid hydraulic-electric architecture (HHEA). This paper compares the performance of the HHEA PTO against two other PTO designs: 1) a baseline PTO consisting of a system of rectifying check valves and accumulators, and 2) a PTO consisting of an electro-hydraulic actuator (EHA). The HHEA PTO is shown to produce much more power than the check valve PTO and the EHA PTO. Also, the required electric generator sizes for the HHEA are smaller than that of the EHA PTO. The reduced size of these components allows for a WEC which is less expensive to manufacture.

16 TIDAL AND WAVE POWER↗

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

The Yucatan Peninsula Energy Assessment: Pathways for a Clean and Sustainable Power System

This report begins with an overview of the status of the power sector in Mexico's Yucatán peninsula, including key challenges, followed by policy and program solutions that pave the way for a cleaner, more sustainable power sector in the Yucatan. This work is intended to provide information to the states of the Yucatán peninsula - Yucatán, Campeche, and Quintana Roo - for prioritization and future technical assistance from the 21st Century Power Partnership (21CPP) program, in Mexico including data gathering, capacity building, modelling and analysis, program and policy setting to help the states and the region overall best utilize its resources to meet its electricity needs while implementing energy efficiency measures towards a more sustainable, clean, reliable system with lower prices. This report is also available in Spanish: https://www.nrel.gov/docs/fy21osti/81142.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of Poly(ether sulfone)‐Based Membranes in Clean Energy Technology

Abstract Poly(ether sulfone) (PES) is a kind of polymer materials with excellent electrical insulation and acid/alkali stability. PES can be operated at high temperature continuously for a long time and still maintain excellent property stability in the environments with rapidly changed temperature, namely, great thermostability. Moreover, PES has low molding shrinkage, good dimensional stability and excellent film‐forming characteristics. Compared with inorganic membranes, PES‐based membranes have lower cost, which have received more attention and wide recognition in the field of clean energy technologies in recent years, such as flow batteries, fuel cells, water treatment, and gas separation. Therefore, this review summarizes the research status and prospect of the utilization of PES‐based membranes in clean energy fields, in order to further promote their development and application.

Chemistry↗

Energy storage solutions to decarbonize electricity through enhanced capacity expansion modelling

To meet ambitious global decarbonization goals, electricity system planning and operations will change fundamentally. With increasing reliance on variable renewable energy resources, energy storage is likely to play a critical accompanying role to help balance generation and consumption patterns. As grid planners, non-profit organizations, non-governmental organizations, policy makers, regulators and other key stakeholders commonly use capacity expansion modelling to inform energy policy and investment decisions, it is crucial that these processes capture the value of energy storage in energy-system decarbonization. Here we conduct an extensive review of literature on the representation of energy storage in capacity expansion modelling. We identify challenges related to enhancing modelling capabilities to inform decarbonization policies and electricity system investments, and to improve societal outcomes throughout the clean energy transition. Additionally, we further identify corresponding research activities that can help overcome these challenges and conclude by highlighting tangible real-world outcomes that will result from pursuing these research activities. Capacity expansion modelling (CEM) approaches need to account for the value of energy storage in energy-system decarbonization. A new Review considers the representation of energy storage in the CEM literature and identifies approaches to overcome the challenges such approaches face when it comes to better informing policy and investment decisions.

25 ENERGY STORAGE↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

Size-Dependent Adsorption and Adhesion Energetics of Ag Nanoparticles on Graphene Films on Ni(111) by Calorimetry

Interest in the use of carbon supports for late transition metal nanoparticle catalysts has expanded rapidly due to the increasing importance of electrocatalysts for clean energy and environmental technologies and the use and storage of renewable electricity. Compared to oxide supports, almost nothing is known about the effect of metal nanoparticle size on the energies of the metal atoms within carbon-supported nanoparticles, yet these energies are crucial for understanding their surface reactivity and sintering kinetics. Here, the growth morphology and adsorption energetics of vapor-deposited Ag onto clean graphene/Ni(111) surfaces have been studied using a combination of single-crystal adsorption calorimetry (SCAC) and He + low-energy ion scattering (LEIS). The differential heat of Ag adsorption is 207 kJ/mol for making ~30 atom Ag particles on graphene terraces at 100 K and 16 kJ/mol higher for making ~9 atom Ag clusters at defect sites at the same temperature. The heat of adsorption increases rapidly with Ag coverage as 3D Ag nanoparticles nucleate and grow in size, asymptotically reaching within 5 kJ/mol of the bulk Ag sublimation enthalpy (285 kJ/mol) by 2 ML. The heats of adsorption and Ag nanoparticle densities from LEIS (~10 16 /m 2 ) were combined to provide the Ag/graphene adhesion energy (E adh = 1.8 J/m 2 in the large-particle limit) and the Ag chemical potential (μ) versus effective particle diameter (D). The Ag chemical potential was well-fitted by μ(D) = (3γ v /M – E adh )(1 + (1.5 nm)/D)(2V m /D), where γ v /M is the surface energy of bulk Ag and V m is its molar volume. The same equation is known to fit similar data for late transition metals on clean surfaces of metal oxide single crystals. The adhesion energy of Ag measured here on graphene falls within the wide range measured for Ag on those oxide surfaces and is almost as large as on the oxide that binds Ag particles most strongly, namely CeO 2 (111), which is well-known to be very effective at resisting catalyst deactivation by metal sintering. Furthermore, these results imply that carbon supports will be effective at resisting sintering and that Ag particles smaller than 6 nm on graphene will bind small adsorbed reaction intermediates more weakly than supports with weaker adhesion to Ag, like MgO(100).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗