Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charge storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

DC Fast Charging Infrastructure for Electrified Road Trips

To assess DC fast charging station network required for electrified road trips by 2030 in California, a new charging infrastructure simulation tool/model, EVI-Pro (Electric Vehicle Infrastructure Projection) RoadTrip, has been developed. In contrast to the existing EVI-Pro model that is primarily for short-distance travels, EVI-Pro RoadTrip is exclusively focused on road trips (long-distance travels, 100 or miles per day per vehicle). Also, the charging paradigm or strategy is different. EVI-Pro RoadTrip is built upon waypoint charging, in which vehicles are forced to stop to charge or replenish the on-board batteries, along the routes between origins and destinations. On the other hand, EVI-Pro is based on destination charging, in which charging is conducted when vehicles are parked in destinations (e.g., work, home). EVI-Pro RoadTrip takes coordinate-level origin and destination data for road trips (intra-state as well as domestic or international out-of-state) and estimates energy consumption and charging needs along the routes between origins and destinations on a minute-by-minute resolution. Based on charging demands for electrified road trips across the state, the optimal locations of charging stations are determined accounting for preferred land use types (e.g., commercial areas) and station service area (e.g., 5 or less miles). Based on station-by-station charging load profiles, the required number of plugs/connectors is estimated for each station and entire state. By comparing hosting capacity of the electric grid (circuit-level) and the charging load output from EVI-Pro RoadTrip, capacity deficit is also evaluated.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Economic dispatch for electricity merchant with energy storage and wind plant: State of charge based decision making considering market impact and uncertainties

Here this paper investigates how the market impact of electricity merchants and uncertainty of wind generation affect their co-optimized scheduling policy, specifically for merchants who have both energy storage and wind plants. In the existing literature, merchants' trading actions are usually assumed not to affect market prices; however, a large-scale energy storage merchant's actions can affect market prices. To this end, we approximate the electricity price by a linear function of the quantity of power traded by the merchant in the reward function to achieve decision-making incorporating the market impact. This paper utilizes the dynamic programming approach to analyze merchants' optimal multi-period decision-making incorporating market impact, uncertain wind generation, and energy storage constraints. First, our results demonstrate that for a merchant with co-located energy storage facilities and wind power plants, the energy storage's feasible state of charge (SOC) range can be segmented into four possible sub-ranges by three analytically developed SOC reference points. The unique optimal trading decision can be achieved by comparing the current energy inventory and the SOC references of the next period. Second, our results show that market impact and uncertainties substantially change the optimal storage scheduling policy by impacting the values of the reference points. To mitigate the negative effect of the merchant's market impact on buying and selling actions, the merchant may reduce the amount of generating or pumping electricity each period to maximize profit. Moreover, we identify and investigate the trade-off between market price and transaction quantity. Our findings provide co-optimized scheduling guidance for electricity merchants with co-located energy storage and renewable power plants systems.

17 WIND ENERGY↗

A simple way to integrate distributed storage into a wholesale electricity market

Abstract Current plans to decarbonize the electric supply system imply that the generation from wind and solar sources will grow substantially. This growth will increase the uncertainty of system operations due to the inherent variability of these renewable sources, and as a result, more reserve capacity will be required to provide the ramping (flexibility) needed for reliable operations. This paper assumes that all of the increased uncertainty comes from wind farms on the grid, and it shows how distributed storage managed locally by aggregators can provide the ramping needed without introducing a separate market for flexibility. This can be accomplished when the aggregators minimize the expected daily cost of the energy purchased from the grid for their customers by submitting optimal bids into the wholesale market with high and low price thresholds for discharging and charging the storage. This model is illustrated using a stochastic multi-period security constrained optimal power flow together with realistic data for a reduction of the network in the Northeast Power Coordinating Council region of the United States. The results show that the bidding strategy for distributed storage provides ramping to the grid just as effectively as storage managed by a system operator.

Lamadrid, Alberto J.↗

Resolving Current-Dependent Regimes of Electroplating Mechanisms for Fast Charging Lithium Metal Anodes

Poor fast-charge capabilities limit the usage of rechargeable Li metal anodes. Understanding the connection between charging rate, electroplating mechanism, and Li morphology could enable fast-charging solutions. In this report we develop a combined electroanalytical and nanoscale characterization approach to resolve the current-dependent regimes of Li plating mechanisms and morphology. Measurement of Li + transport through the solid electrolyte interphase (SEI) shows that low currents induce plating at buried Li||SEI interfaces, but high currents initiate SEI-breakdown and plating at fresh Li||electrolyte interfaces. The latter pathway can induce uniform growth of {110}-faceted Li at extremely high currents, suggesting ion-transport limitations alone are insufficient to predict Li morphology. At battery relevant fast-charging rates, SEI-breakdown above a critical current density produces detrimental morphology and poor cyclability. Thus, prevention of both SEI-breakdown and slow ion-transport in the electrolyte is essential. This mechanistic insight can inform further electrolyte engineering and customization of fast-charging protocols for Li metal batteries.

25 ENERGY STORAGE↗

Surface coating by mechanofusion modulates bulk charging pathways and battery performance of Ni-rich layered cathodes

Ni-rich layered oxides as high-capacity battery cathodes suffer from degradation at high voltages. Here, we utilize a dry surface modification method, mechanofusion (MF), to achieve enhanced battery stability. The simplicity, high yield, and flexibility make it cost-effective and highly attractive for processing at the industrial scale. The underlying mechanisms responsible for performance improvement are unveiled by a systematic study combining multiple probes, e.g., 3D nano-tomography, spectroscopic imaging, in situ synchrotron diffraction, and finite element analysis (FEA). MF affects the bulk crystallography by introducing partially disordered structure, microstrain, and local lattice variation. Furthermore, the crack initiation and propagation pattern during delithiation are regulated and the overall mechanical fracture is reduced after such surface coating. We validate that MF can alter the bulk charging pathways. Such a synergic effect between surface modification and bulk charge distribution is fundamentally important for designing next-generation battery cathode materials.

25 ENERGY STORAGE↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Consequence-Driven Cybersecurity for High-Power Electric Vehicle Charging Infrastructure

Cybersecurity of high-power charging infrastructure for electric vehicles (EVs) is critical to the safety, reliability, and consumer confidence in this publicly accessible technology. Cybersecurity vulnerabilities in high-power EV charging infrastructure may also present risks to broader transportation and energy-infrastructure systems. Here, this paper details a methodology used to analyze and prioritize high-consequence events that could result from cybersecurity sabotage to high-power charging infrastructure. The highest prioritized events are evaluated under laboratory conditions for the severity of impact and the complexity of cybersecurity manipulation. Mitigation solutions and strategies are presented to secure the vulnerabilities that potentially lead to high-consequence events. These mitigations can be immediately implemented by industry or executed during the design stage.

25 ENERGY STORAGE↗

Energy and Power Evolution Over the Lifetime of a Battery

Li-ion batteries currently are dominant energy storage devices for electric vehicles. Rechargeable batteries with lower cost, longer lifetime, and higher safety are desired in support of building of a green grid infrastructure. The continued investment in new battery materials, novel battery structures, advanced manufacturing processes, and accelerated testing/validation of battery performance has led to significant progress in battery development and deployment. Battery safety/reliability, which is essential to the success of a battery technology in the real world, naturally becomes the next big topic in battery research. Recently, the increasing interest in long-duration storage, fast charging, battery secondary use, and material recycling to build a circular industry and sustainable material supply chain has compelled further attention to understand the energy/power evolution and safety over the lifetime of a battery. Here, in this short Viewpoint, we discuss some high-level analyses on the energy/power evolution of rechargeable batteries over their life cycles aiming to inspire more discussion on the safety and sustainability of some representative and emerging battery technologies.

25 ENERGY STORAGE↗

Rational designs to enable 10-min fast charging and long cycle life in lithium-ion batteries

A daunting challenge in the design of lithium ion batteries (LiBs) is enabling 10-min extreme fast charging (XFC) while achieving appreciable charge acceptance and cycle life. This desirable outcome requires both a comprehensive understanding of LiB operation and aging behavior at different length scales and careful optimization. Lithium plating has been a critical bottleneck because, at XFC rates, it consumes cyclable lithium causing distinct aging and safety concerns even in moderate-loading LiBs. Here, we propose combining multiple solutions, including materials-to-electrode design-to-charging protocols, that are intended to overcome limitations in lithium-ion transport in the electrolyte phase, thus enabling 10-min XFC in LiBs. Some implemented strategies include cathode chemistry, optimized carbon binder domain in the cathode, dual layer anode design, improved separator and advanced electrolyte. Further, innovative charging protocols in moderately loading (~3 mAh/cm 2 anode/2.7 mAh/cm 2 cathode) single-layer pouch cells are proposed, together with demonstrated 10-min XFC with higher charge acceptance between 87.3 and 92.1% (or 2–2.1 mAh/cm 2 ) for 600 cycles without lithium plating. This methodical study with well-defined cells shows promise in combining multiple solution strategies to enable 10-min XFC, charting a pathway to achieve XFC in higher-loading energy-optimized LiBs.

25 ENERGY STORAGE↗

In Silico Discovery of Covalent Organic Frameworks for Carbon Capture

We screen a database of more than 69 000 hypothetical covalent organic frameworks (COFs) for carbon capture using parasitic energy as a metric. To compute CO 2 –framework interactions in molecular simulations, we develop a genetic algorithm to tune the charge equilibration method and derive accurate framework partial charges. Nearly 400 COFs are identified with parasitic energy lower than that of an amine scrubbing process using monoethanolamine; more than 70 are better performers than the best experimental COFs and several perform similarly to Mg-MOF-74. We analyze the effect of pore topology on carbon capture performance to guide the development of improved carbon capture materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge Transport Properties of Lithium Superoxide in Li–O 2 Batteries

The theoretical energy density of lithium–oxygen (Li–O 2 ) batteries is extremely high, although there are many challenges that must be overcome to achieve high energy density in a manufactured cell. For example, little is known about the properties of one of the key intermediates, lithium superoxide (LiO 2 ), which until recently had not been stabilized in bulk form. In this work, lithium superoxide was deposited onto iridium–reduced graphene oxide (Ir–rGO) cathodes in a Li–O 2 system under a flow of O 2 . Lithium peroxide (Li 2 O 2 ) was subsequently produced on the cathode surface in an inert Ar atmosphere. Based on a detailed analysis of electrochemical impedance spectroscopy data, it was demonstrated experimentally for the first time that the charge transport resistance through LiO 2 was much lower than for Li 2 O 2 and correlated with lower LiO 2 charge overpotentials. We report this result indicates that LiO 2 has good electronic conductivity and confirms previous theoretical predictions that bulk LiO 2 has better charge transport properties than Li 2 O 2 . In addition, impedance and other characterization of Li 2 O 2 formation from LiO 2 in an Ar atmosphere revealed that when surface-mediated Li 2 O 2 formation occurs, it has a significantly lower discharge potential than when it forms through a solution-phase-mediated process. These significant findings will contribute to the development of Li–O 2 batteries through better understanding of LiO 2 properties and formation mechanisms.

25 ENERGY STORAGE↗

Strategies for Enhancing Battery Life Under Fast Charging: Insights from NMC-Based Cell Cycling

Fast charging improves the usability of consumer electronics and electric vehicles (EVs) by reducing range anxiety and downtime but accelerates battery degradation and raises safety concerns. Optimizing operational conditions during fast-charging is critical to mitigating aging and ensuring safety. This study evaluated multilayer Gr/NMC811 cells under various conditions, including depths of discharge (DODs of 68%, 84%, and 100%), upper charge cutoff voltages (4.1–4.2 V), and post-charge rest periods (2–30 min), using a 20 min fast charging protocol for up to 500 cycles (up to 150,000 miles of EV use assuming 3.3 mi/kWh vehicle level energy efficiency). Surprisingly, higher DODs under fast charging improved battery life and performance compared to lower DODs. Reducing the upper charge cut-off voltage helped mitigate degradation. A brief 2 min rest period after charging further reduced aging effects. The primary aging modes were loss of lithium inventory and cathode active material. Although minor lithium plating was observed within 500 cycles, it did not affect performance significantly. These findings suggest that, with optimized conditions, cells can sustain hundreds of fast charge cycles—equivalent to over 100,000 miles of EV use—without significant adverse effects on performance or longevity.

25 - ENERGY STORAGE↗

Colloidal synthesis and charge carrier dynamics of Cs 4 Cd 1-x Cu x Sb 2 Cl 12 (0 ≤ x ≤ 1) layered double perovskite nanocrystals

The toxicity and instability of lead-based metal halide perovskites are the two main obstacles that prevent perovskite materials from implementation in applications. Recently, layered double perovskites (LDPs) emerge as a new family of perovskite materials which provide a new route to solve these problems by lead-component replacement and reduction of crystal structure dimensionality. However, LDP nanocrystals (NCs) have been rarely studied, limiting the further property exploration and application realization. In this work, we report the colloidal synthesis of a series of Cs 4 Cd 1-x Cu x Sb 2 Cl 12 (0 ≤ x ≤ 1) LDP NCs by tuning the stoichiometry of metal precursors. The composition-structure-property relationships of the resulting LDP NCs are studied through materials characterizations, density functional theory calculations, and transient-absorption spectroscopy. In addition, we demonstrate that high-performance high-speed photodetectors can be fabricated using the colloidal LDP NCs through solution-processing. This work premises further expansion of such LDP-based materials for both fundamental studies and application integrations.

25 ENERGY STORAGE↗

Preparation and electrochemical properties of high-entropy oxide Li x (CrMnCoNiZn) 3-x O 4

High-entropy oxides (HEOs) have gained significant attention as anode materials for lithium-ion batteries (LIBs) due to their high theoretical specific capacity, synergistic effects of constituent elements, and enhanced structural stability induced by high entropy. Here, this study investigates the electrochemical properties of a novel series of HEOs, Li x (CrMnCoNiZn) 3-x O 4 , synthesized via the sol-gel method. As lithium content increases, the electrochemical lithium storage performance of the HEOs improves, attributed to the rise in high-valence states and oxygen vacancies. The high valence state of elements facilitates greater electron transfer, enhancing the specific capacity during lithium insertion. Additionally, a higher concentration of oxygen vacancies boosts ionic conductivity and lithium ion diffusion kinetics, leading to superior electrochemical performance. Among the synthesized materials, Li 0.11 (CrMnCoNiZn) 2.89 O 4 exhibited the best performance, delivering a discharge capacity of 365 mAh·g −1 after 100 cycles at 100 mA·g −1 , 257 mAh·g −1 after 1000 cycles at 1 A·g −1 , and a rate capacity of 196 mAh·g −1 at 2 A·g −1 . The Li + diffusion coefficient reached 2.78 × 10 −15 cm 2 ·s −1 . This work not only deepens the understanding of HEOs' electrochemical behavior in LIBs but also provides insights into the impact of lithium ion substitution on their performance.

25 ENERGY STORAGE↗

A country-scale green energy-water-hydrogen nexus: Jordan as a case study

Many developing countries suffer from a shortage of clean energy-water production, causing significant dependency on imported fossil fuel to meet the local energy and freshwater demands. Furthermore, when planning a 100 % renewable energy system (RES) to match the energy demand on an hourly basis, the RES is usually oversized. Hence, unavoidable large amounts of excess energy would be generated during hours of high production, low demand, and fully charged energy storage systems (ESSs). Hence, using Jordan as a case study, this work proposes a novel integrated system of wind, solar photovoltaic (PV), and lithium-ion ESS to match 100 % of the country's energy demand while using the excess generated power to drive reverse osmosis water desalination plants to match the demand of freshwater as well. Furthermore, the remaining excess energy is used for producing green hydrogen. A techno-economic optimizer was developed to show that this concept is indeed feasible. Here, the model was used to scan Jordan for the fitting sites of the highest demand-supply matching and the lowest levelized cost of electricity (LCOE), simultaneously. Three different integration scenarios are presented, namely PV-ESS, wind-ESS, and hybrid PV-wind-ESS RESs. The hybrid system showed the best performance, especially compared to the wind-ESS RES, in terms of total installed capacity (33.37 GW), LCOE (0.0492 USD/kWh), specific water cost (0.3629 USD/m 3 ), and energy and water demand-supply fractions (99.47 and 96.16 %, respectively). Storing desalinated water in natural aquifers was found to be a favorable option to enhance the performance of the three systems, where stored water by the end of the year was sufficient to cover the freshwater requirements for several following years. Finally, the remaining excess energy is used to produce green hydrogen with an annual production of up to 1.37 million tons and a specific cost down to 1.08 USD/kg.

14 SOLAR ENERGY↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗