An Empirical Roofline Methodology for Quantitatively Assessing Performance Portability

System and node architectures continue to diversify to better balance on-node computation, memory capacity, memory bandwidth, interconnect bandwidth, power, and cost for specific computational workloads. For many application developers, achieving performance portability (effectively exploiting the capabilities of multiple architectures) is a desired goal. Unfortunately, dramatically different per-node performance coupled with differences in machine balance can lead to developers being unable to determine whether they have attained performance portability or simply written portable code. The Roofline model provides a means of quantitatively assessing how well a given application makes use of a target platform’s computational capabilities. In this paper, we extend the Roofline model so that it 1) empirically captures a more realistic set of performance bounds for CPUs and GPUs, 2) factors in the true cost of different floating-point instructions when counting FLOPs, 3) incorporates the effects of different memory access patterns, and 4) with appropriate pairing of code performance and Roofline ceiling, facilitates the performance portability analysis.

Computer Science↗

Vacant niches help predict invasion risk by birds

Abstract Aim If communities have a ceiling determining the number of species that can coexist, then the ability of alien species to establish at any given location should be related to the quantity of vacant niches available. We developed a new approach to estimate the extent to which niches are vacant and then explored the relationship between vacant niches and alien species. Location Global with focal tests in Europe and North America. Taxon Birds. Methods Drawing on a global classification of trophic structures for birds, we calculated a ‘vacant niche ratio’ metric to quantify the expected level of saturation (i.e. number of vacant niches) for each 1° × 1° grid cell globally, based on the difference between expected and observed numbers of bird species for all trophic guilds. Next, we used random forests to examine if the presence of plant‐invertivore (whose food source represents plants, seeds, fruits and invertebrates) and granivore alien bird species was associated with the vacant niche ratio across well‐sampled regions. Results In Europe, we found a significant relationship between alien species and vacant niches, with greater numbers of alien species being found in communities that offered greater numbers of vacant niches overall, and across habitat types. In North America, we found no significant relationship between plant‐invertivores and vacant niches, while for granivores, we found that areas with fewer vacant niches had greater numbers of alien species, especially in forests. However, vacant niches alone correctly predict 69% of the presence of alien bird species when combining both regions and trophic guilds. Main Conclusions Most regions of the world have unsaturated bird communities, with the level of saturation in communities varying within regions and trophic guilds. We found that although often‐neglected, vacant niches are likely to be, at least partially, related with the successful establishment of alien bird species.

González‐del‐Pliego, Pamela↗

Management of the decommissioning of the Thetis reactor

The Thetis research reactor on the site of the Nuclear Sciences Institute of the Ghent University has been in operation from 1967 until December 2003. This light-water moderated graphite-reflected low-enriched uranium pool-type reactor has been used for various purposes e.g. the production of radioisotopes and activation analyses. During the first years its core power was 15 kW. In the early '70, a core enlargement allowed for operation at typically 150 kW, while the maximum was allowed to be 250 kW In September 2007, Ghent University entrusted to SCK-CEN the management of the back-end of the spent fuel and the decommissioning of the reactor. In 2010, the spent fuel was removed from the reactor and transported to Belgoprocess for cementation in 400 l drums and interim storage awaiting final disposal. This activity allows tackling the decommissioning of the reactor. The objective is to complete its decommissioning by the end of 2014. In the framework of the decommissioning of the Thetis reactor, SCK-CEN set-up the final decommissioning plan and the decommissioning licensing file. These documents include among others a radiological inventory of the reactor. The graphite moderator blocks, the control and the safety pates, the liner of the pool were modeled to assess the activation products (isotopic vector and intensity). At the end of the unloading of the reactor in 2010 a brief mapping of the equipment's and internals of the reactor pool was performed. In 2012, we realized a more detailed mapping. These results confirmed those performed earlier and allowed to confirm the assumptions made in the final decommissioning plan. We set-up the terms of reference for the first decommissioning phase of the reactor namely the dismantling of the reactor i.e. reactor pool, circuits and rabbit system, equipment's and ventilation ducts. The removal of asbestos is also included into this phase. We conducted the selection process and the awarding of this decommissioning job. We gained the decommissioning license in May 2012. We also prepared the software tool allowing managing the decommissioning project by updating the inventory and recording the progress, the characterization measurements and the material and waste production. This software allows also to trace all the material streams and to report to the Authorities. This software is a simplified release of the ones developed by SCK-CEN in the framework of other decommissioning projects like BR3 and Belgonucleaire. The dismantling of the reactor i.e. reactor pool, circuits and rabbit system, will be performed in 2013. In 2014, it is planned to map all the surfaces of the infrastructure to highlight residual contamination of floor, walls and ceiling. The contaminated surfaces will be decontaminated and controlled. The objective is to reach the free release of the reactor building and laboratories by the end of 2014. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator

Purpose: The purpose of this study was to explore the effects of a paraffin screen located at various positions in the maze on the neutron dose equivalent at the maze door.Methods: The neutron dose equivalent was measured at the maze door of a room containing a 15 MV linear accelerator for x-ray therapy. Measurements were performed for several positions of the paraffin screen covering only 27.5% of the cross-sectional area of the maze. The neutron dose equivalent was also measured at all screen positions. Two simple models of the neutron source were considered in which the first assumed that the source was the cross-sectional area at the inner entrance of the maze, radiating neutrons in an isotropic manner. In the second model the reduction in the neutron dose equivalent at the maze door due to the paraffin screen was considered to be a function of the mean values of the neutron fluence and energy at the screen.Results: The results of this study indicate that the equivalent dose at the maze door was reduced by a factor of 3 through the use of a paraffin screen that was placed inside the maze. It was also determined that the contributions to the dosage from areas that were not covered by the paraffin screen as viewed from the dosimeter, were 2.5 times higher than the contributions from the covered areas. This study also concluded that the contributions of the maze walls, ceiling, and floor to the total neutron dose equivalent were an order of magnitude lower than those from the surface at the far end of the maze.Conclusions: This study demonstrated that a paraffin screen could be used to reduce the neutron dose equivalent at the maze door by a factor of 3. This paper also found that the reduction of the neutron dose equivalent was a linear function of the area covered by the maze screen and that the decrease in the dose at the maze door could be modeled as an exponential function of the product φ·E at the screen.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-184: Stereo Time-Of-Flight System for Patient Positioning in Radiotherapy

Purpose: The objective of this work is to test the advantage of using the surface acquired by two stereo Time-of-Flight (ToF) cameras in comparison of the use of one camera only for patient positioning in radiotherapy. Methods: A first step consisted on validating the use of a stereo ToFcamera system for positioning management of a phantom mounted on a linear actuator producing very accurate and repeatable displacements. The displacements between two positions were computed from the surface point cloud acquired by either one or two cameras thanks to an iterative closest point algorithm. A second step consisted on determining the displacements on patient datasets, with two cameras fixed on the ceiling of the radiotherapy room. Measurements were done first on voluntary subject with fixed translations, then on patients during the normal clinical radiotherapy routine. Results: The phantom tests showed a major improvement in lateral and depth axis for motions above 10 mm when using the stereo-system instead of a unique camera (Fig1). Patient measurements validate these results with a mean real and measured displacement differences in the depth direction of 1.5 mm when using one camera and 0.9 mm when using two cameras (Fig2). In the lateral direction, a mean difference of 1 mm was obtained by the stereo-system instead of 3.2 mm. Along the longitudinal axis mean differences of 5.4 and 3.4 mm with one and two cameras respectively were noticed but these measurements were still inaccurate and globally underestimated in this direction as in the literature. Similar results were also found for patient subjects with a mean difference reduction of 35%, 7%, and 25% for the lateral, depth, and longitudinal displacement with the stereo-system. Conclusion: The addition of a second ToF-camera to determine patient displacement strongly improved patient repositioning results and therefore insures better radiation delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP Report 147 is still sufficient for the Hologic DBT system given the workload from a previous survey at MGH. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch errors within the criteria suggested by AAPM TG142 for linacs used for IMRT.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

TU-D-209-07: Monte Carlo Assessment of Dose to the Lens of the Eye of Radiologist Using Realistic Phantoms and Eyeglass Models

Purpose: To study how eyeglass design features and postures of the interventional radiologist affect the radiation dose to the lens of the eye. Methods: A mesh-based deformable phantom, consisting of an ultra-fine eye model, was used to simulate postures of a radiologist in fluoroscopically guided interventional procedure (facing the patient, 45 degree to the left, and 45 degree to the right). Various eyewear design features were studied, including the shape, lead-equivalent thickness, and separation from the face. The MCNPX Monte Carlo code was used to simulate the X-ray source used for the transcatheter arterial chemoembolization procedure (The X-ray tube is located 35 cm from the ground, emitting X-rays toward to the ceiling; Field size is 40cm X 40cm; X-ray tube voltage is 90 kVp). Experiments were also performed using dosimeter placed on a physical phantom behind eyeglasses. Results: Without protective eyewear, the radiologist’s eye lens can receive an annual dose equivalent of about 80 mSv. When wearing a pair of lead eyeglasses with lead-equivalent of 0.5-mm Pb, the annual dose equivalent of the eye lens is reduced to 31.47 mSv, but both exceed the new ICRP limit of 20 mSv. A face shield with a lead-equivalent of 0.125-mm Pb in the shape of a semi-cylinder (13cm in radius and 20-cm in height) would further reduce the exposure to the lens of the eye. Examination of postures and eyeglass features reveal surprising information, including that the glass-to-eye separation also plays an important role in the dose to the eye lens from scattered X-ray from underneath and the side. Results are in general agreement with measurements. Conclusion: There is an urgent need to further understand the relationship between the radiation environment and the radiologist’s eyewear and posture in order to provide necessary protection to the interventional radiologists under newly reduced dose limits.

60 APPLIED LIFE SCIENCES↗

WE-DE-207B-09: Scatter Radiation Measurement From a Digital Breast Tomosynthesis System and Its Impact On Shielding Consideration

Purpose: To accurately measure the scatter radiation from a Hologic digital breast tomosynthesis (DBT) system and to provide updated scatter distribution to guide radiation shielding calculation for DBT rooms. Methods: A high sensitivity GOS-based linear detector was used to measure the angular distribution of scatter radiation from a Hologic Selenia Dimensions DBT system. The linear detector was calibrated for its energy response of typical DBT spectra. Following the NCRP147 approach, the measured scatter intensity was normalized by the primary beam area and primary air kerma at 1m from the scatter phantom center and presented as the scatter fraction. Direct comparison was made against Simpkin’s initial measurement. Key parameters including the phantom size, primary beam area, and kV/anode/target combination were also studied. Results: The measured scatter-to-primary-ratio and scatter fraction data closely matched with previous data from Simpkin. The measured data demonstrated the unique nonisotropic distribution of the scattered radiation around a Hologic DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous local survey, the scatter air kerma at 1m from the phantom center for wall/door is 0.018mGy/patient, for floor is 0.164mGy/patient, and for ceiling is 0.037mGy/patient. Conclusion: Comparing to Simpkin’s previous data, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload, added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP147 is still sufficient for the Hologic DBT system given the workload from a previous local survey. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

60 APPLIED LIFE SCIENCES↗

Benchmark analytical solutions for steady state high frequency broadband sound fields in three rectangular enclosures

Analytical solutions are presented for broadband sound fields in three rectangular enclosures with absorption applied on the floor and ceiling, rigid sidewalls, and a vertically oriented dipole source. The solutions are intended to serve as benchmarks that can be used to assess the performance of broadband techniques, particularly energy-based methods, in a relatively straightforward configuration with precisely specified boundary conditions. A broadband Helmholtz solution is developed using a frequency-by-frequency modal approach to determine the exact band averaged mean-square pressures along spatial trajectories within each enclosure. Due to the specific choice of enclosure configuration and absorption distribution, an approximate specular solution can be obtained through a summation of uncorrelated image sources. Comparisons between the band averaged Helmholtz solution and the uncorrelated image solution reveal excellent agreement for a wide range of absorption levels and improve the understanding of correlation effects in broadband sound fields. In conclusion, a boundary element solution with diffuse boundaries is also presented, which produces consistently higher mean-square pressures in comparison with the specular solution, emphasizing the careful attention that must be placed on correctly modeling reflecting boundary conditions and demonstrating the errors that can result from assuming a Lambertian surface.

42 ENGINEERING↗

Dataset: Occupancy Detection, Tracking, and Estimation Using a Vertically Mounted Depth Sensor

Occupancy detection, tracking, and estimation has a wide range of applications including improving building energy efficiency, safety, and security of the occupants. As depth sensors are getting cheaper, they offer a viable solution to estimate occupancy accurately in a non-privacy invasive manner. Even though there are publicly available depth datasets, they do not consider placing the sensor in the ceiling looking downwards to estimate occupancy. We deployed four Kinect for XBOX One in four CMU classrooms and conference rooms for a period of four weeks in 2017 and collected over 6 TB of depth data. We annotate this huge dataset by labelling bounding boxes around occupants and release the annotated dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of MCNP Critical Benchmark Models of Moderated Highly Enriched Uranium Slabs

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with HEU-MET-FAST-007, “Uranium Metal Slabs Moderated with Polyethylene, Plexiglas, and Teflon”. The Monte Carlo n-Particle (MCNP) models were compared to the second revision of HEU-MET-FAST-007. The experiment considered critical configurations of highly enriched uranium (HEU) metal slabs and various moderators in 43 unique cases. The slabs of uranium were separated by layers of moderating material, forming an assembly. The assembly was separated in two halves with one half placed on a stationary table and the other attached to a moveable table that could be raised and lowered via pulleys connected to the ceiling of the shielded room. To reach criticality, the two halves were brought together with a negligible gap between the assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving the spatial dynamic range of digital inline particle holography

Digital in-line holography (DIH) has been proven to provide three-dimensional droplet position, size, and velocity distributions with a single-camera. This data is crucial for understanding multi-phase flows. In this work, we examine the performance of this diagnostic in the limit of very small particles, on the order of a pixel in diameter and smaller, and propose a post-processing method to improve them: Lanczos interpolation. The Lanczos interpolation kernel is the digital implementation of the Whittaker sinc filter, and strikes a compromise between maintaining the spatial frequency ceiling of the original digital image and computational cost of the interpolation. Without Lanczos interpolation, or super-sampling, the ultimate detectable particle size floor is on the order of 4 pixel widths. We show in this work that this limit can be reduced by 50% or more with super-sampling, depending upon the desired diameter accuracy, and examine the effect of super-sampling on the resulting accuracy of the extracted size and position of spherical particles. Extending this resolution limit increases the overall detection efficiency of the diagnostic. Since this increases the spatial dynamic range of the diagnostic, it can also allow a larger field-of-view to be captured with the same particle size floor.

47 OTHER INSTRUMENTATION↗

Scaling the polymerization of polyaldehydes through continuous flow synthesis

Abstract A plug flow reactor was constructed to scale the synthesis of metastable, phthalaldehyde-based polymers to achieve production rates of 1–2 kg per day. The flow-induced mixing and in-line polymerization quench and precipitation sequences resulted in improved polymer purity and long-term stability compared to the same materials made from a conventional batch process. Cryogenic rheology was used to probe the complex fluid dynamics encountered during the polymerization of PPA homopolymers. It is envisioned that this continuous flow manufacturing approach could be extended to other low ceiling temperature or aldehyde monomer systems to help implement and support a plastic circular economy. Graphical abstract

Schwartz, Jared M.↗