Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SU-F-BRB-05: Collision Avoidance Mapping Using Consumer 3D Camera

Purpose: To develop a fast and economical method of scanning a patient’s full body contour for use in collision avoidance mapping without the use of ionizing radiation. Methods: Two consumer level 3D cameras used in electronic gaming were placed in a CT simulator room to scan a phantom patient set up in a high collision probability position. A registration pattern and computer vision algorithms were used to transform the scan into the appropriate coordinate systems. The cameras were then used to scan the surface of a gantry in the treatment vault. Each scan was converted into a polygon mesh for collision testing in a general purpose polygon interference algorithm. All clinically relevant transforms were applied to the gantry and patient support to create a map of all possible collisions. The map was then tested for accuracy by physically testing the collisions with the phantom in the vault. Results: The scanning fidelity of both the gantry and patient was sufficient to produce a collision prediction accuracy of 97.1% with 64620 geometry states tested in 11.5 s. The total scanning time including computation, transformation, and generation was 22.3 seconds. Conclusion: Our results demonstrate an economical system to generate collision avoidance maps. Future work includes testing the speed of the framework in real-time collision avoidance scenarios. Research partially supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

High sensitivity imaging Thomson scattering for low temperature plasma

A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a ''Generation III'' image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n{sub e}) and 6% in the electron temperature (T{sub e}) at n{sub e}=4x10{sup 19} m{sup -3}. This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9x10{sup 17} m{sup -3} in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n{sub e} and T{sub e} measurement is 7x10{sup 20}/n{sub e} J, which means that single shot measurements are possible for n{sub e}>2x10{sup 21} m{sup -3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

Advanced Thomson scattering system for high-flux linear plasma generator

An advanced Thomson scattering system has been built for a linear plasma generator for plasma surface interaction studies. The Thomson scattering system is based on a Nd:YAG laser operating at the second harmonic and a detection branch featuring a high etendue (f /3) transmission grating spectrometer equipped with an intensified charged coupled device camera. The system is able to measure electron density (n{sub e}) and temperature (T{sub e}) profiles close to the output of the plasma source and, at a distance of 1.25 m, just in front of a target. The detection system enables to measure 50 spatial channels of about 2 mm each, along a laser chord of 95 mm. By summing a total of 30 laser pulses (0.6 J, 10 Hz), an observational error of 3% in n{sub e} and 6% in T{sub e} (at n{sub e}= 9.4 Multiplication-Sign 10{sup 18} m{sup -3}) can be obtained. Single pulse Thomson scattering measurements can be performed with the same accuracy for n{sub e} > 2.8 Multiplication-Sign 10{sup 20} m{sup -3}. The minimum measurable density and temperature are n{sub e} < 1 Multiplication-Sign 10{sup 17} m{sup -3} and T{sub e} < 0.07 eV, respectively. In addition, using the Rayleigh peak, superimposed on the Thomson scattered spectrum, the neutral density (n{sub 0}) of the plasma can be measured with an accuracy of 25% (at n{sub 0}= 1 Multiplication-Sign 10{sup 20} m{sup -3}). In this report, the performance of the Thomson scattering system will be shown along with unprecedented accurate Thomson-Rayleigh scattering measurements on a low-temperature argon plasma expansion into a low-pressure background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving quality assurance for assembled COMS eye plaques using a pinhole gamma camera

A quality assurance system has been designed to verify the location and strength of seeds loaded in a brachytherapy eye plaque. This system consists of (1) a pinhole camera in conjunction with a Lumisys ACR-2000i computed radiography (CR) unit to image the location and measure the relative strength of the seeds with autoradiography, and (2) a source strength jig with a survey meter to estimate the total activity of the seeds in the plaque. Five holders of different sizes were made for fixation of the COMS (Collaborative Ocular Melanoma Study) plaques (12, 14, 16, 18, and 20 mm) in the camera. The plaque-to-pinhole distance (d{sub pp}) has been optimized to be 30 mm to give approximately uniform intensity on the CR image for uniformly loaded COMS plaques. The pinhole-to-detector distance (d{sub pd}) can be kept at either 30 mm for 1:1 scale, or at larger distances for higher magnification. For a 1:1 scaling and pinhole diameter of 0.345 mm, useful images are obtained with time-activity product (mCi sec) ranging from 5 to 250 mCi sec. Within this range, the pinhole system is able to differentiate seed activities of >10%. The resulting pinhole autoradiograph is able to (1) confirm the correct number of seeds loaded in the plaque, (2) verify the proper sitting of the seeds in the silastic carrier and the plaque, (3) verify the relative activity distribution of the seeds loaded in the plaque, and (4) potentially evaluate the integrity of the seed. The source strength measurement system is able to measure the total strength of seeds in the plaque ranging from 10 to 80 mCi with an uncertainty of 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a 3-D visible limiter imaging system for the HSX stellarator

A visible camera diagnostic has been developed to study the Helically Symmetric eXperiment (HSX) limiter plasma interaction. A straight line view from the camera location to the limiter was not possible due to the complex 3D stellarator geometry of HSX, so it was necessary to insert a mirror/lens system into the plasma edge. A custom support structure for this optical system tailored to the HSX geometry was designed and installed. This system holds the optics tube assembly at the required angle for the desired view to both minimize system stress and facilitate robust and repeatable camera positioning. The camera system has been absolutely calibrated and using H α and C-III filters can provide hydrogen and carbon photon fluxes, which through an S/XB coefficient can be converted into particle fluxes. The resulting measurements have been used to obtain the characteristic penetration length of hydrogen and C-III species. Here, the hydrogen λ iz value shows reasonable agreement with the value predicted by a 1D penetration length calculation.

47 OTHER INSTRUMENTATION↗

SU-F-J-190: Time Resolved Range Measurement System Using Scintillator and CCD Camera for the Slow Beam Extraction

Purpose: To investigate the time structure of the range, we have verified the rang shift due to the betatron tune shift with several synchrotron parameters. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. Using image processing, the range was determined the 80 percent of distal dose of the depth light distribution. The root mean square error of the range measurement using the scintillator and CCD system is about 0.2 mm. Range measurement was performed at interval of 170 msec. The chromaticity of the synchrotron was changed in the range of plus or minus 1% from reference chromaticity in this study. All of the particle inside the synchrotron ring were extracted with the output beam intensity 1.8×10{sup 8} and 5.0×10{sub 7} particle per sec. Results: The time strictures of the range were changed by changing of the chromaticity. The reproducibility of the measurement was sufficient to observe the time structures of the range. The range shift was depending on the number of the residual particle inside the synchrotron ring. Conclusion: In slow beam extraction for scanned carbon-ion therapy, the range shift is undesirable because it causes the dose uncertainty in the target. We introduced the time-resolved range measurement using scintillator and CCD system. The scintillator and CCD system have enabled to verify the range shift with sufficient spatial resolution and reproducibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration and operation of a sUAS-based multi-modal imaging payload equipped with a novel communication system enabling autonomous platform control

Oak Ridge National Laboratory presents a new UAS-mounted multi-modal imaging payload containing five sensors. We have integrated several distinct commercially available sensors onto a large Class-1 autonomous quadcopter aircraft: a LIDAR (Light Detection and Ranging) scanner, a hyperspectral pushbroom sensor, a multispectral camera, a longwave infrared thermal camera, and an RGB camera. The system integrates our proprietary Multi-modal Autonomous Vehicle Network (MAVNet) and communication system, allowing autonomous control via multiple communication networks. Using one common Global Navigation Satellite System (GNSS) and inertial navigation system (INS/GPS), imagery from all sensors are accurately and precisely geolocated and co-registered.

Duncan, Andrew↗

Thermal-Mechanical Analysis for in-Vessel Diagnostic Components in W7-X

For long pulse plasma operation of the W7-X stellarator, the most serious challenge for the design of in-vessel diagnostic systems is the thermo-mechanical problem. Thermal load from convective losses and from plasma radiation can be as high as 500 kW/m{sup 2} at some locations close to plasma. The typical thermal load from plasma radiation alone ranges from several 10 to 100 kW/m{sup 2} as derived from 3-D Monte-Carlo simulations. A finite element analysis (FEA-ANSYS) is conducted for a better understanding of thermo-mechanical effects on in-vessel diagnostic components and to guide the design of the diagnostic system for steady state operation. All in-vessel diagnostic components require active cooling. Besides for long-pulse plasma operation optical components must be optimized to minimize thermal deformations. In this paper, we present the thermo-mechanical analyses of the CO{sub 2}-laser interferometer retro-reflectors, the diamagnetic loops and the soft X-ray multi camera tomography system (XMCTS)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

60 APPLIED LIFE SCIENCES↗

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

Smart Infrared Inspection System Field Operational Test (Final Report)

The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

brake system↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is a fast-response, time-dependent beam diagnostic for measuring the emitted spot size and beam target interactions from radiographic x-ray sources. Legacy streaked TRSD analysis requires image processing and data extraction, which give noisy results. Processed data are used to extract edge spread and corresponding line spread functions. Digital TRSD simplifies this process, eliminating the complexity of streak camera–based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the core-corona structure formed during the explosion of an aluminum wire in vacuum

The time evolution of the matter parameters and current distribution in the discharge channel formed during a nanosecond explosion of a 25-{mu}m-diameter 12-mm-long aluminum wire was studied in a series of experiments with the following parameters: the discharge voltage was U{sub 0} = 20 kV, the current amplitude was I{sub max} {approx} 8 kA, and the current rise rate was dI/dt {approx} 40 A/ns. Optical shadow and schlieren images of the discharge channel were obtained using the second harmonic of a YAG: Nd{sup +3} laser, and UV images of the discharge channel self-radiation were recorded using a four-frame camera with a microchannel plate. The process of aluminum wire explosion was simulated numerically (including simulations performed from the 'cold start'). The numerical results were compared with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond laser electronic excitation tagging for quantitative velocity imaging in air

Time-accurate velocity measurements in unseeded air are made by tagging nitrogen with a femtosecond-duration laser pulse and monitoring the displacement of the molecules with a time-delayed, fast-gated camera. Centimeter-long lines are written through the focal region of a {approx}1 mJ, 810 nm laser and are produced by nonlinear excitation and dissociation of nitrogen. Negligible heating is associated with this interaction. The emission arises from recombining nitrogen atoms and lasts for tens of microseconds in natural air. It falls into the 560 to 660 nm spectral region and consists of multiple spectral lines associated with first positive nitrogen transitions. The feasibility of this concept is demonstrated with lines written across a free jet, yielding instantaneous and averaged velocity profiles. The use of high-intensity femtosecond pulses for flow tagging allows the accurate determination of velocity profiles with a single laser system and camera.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Effectiveness of a Detection and Deterrent System in Reducing Golden Eagle Fatalities at Operational Wind Facilities

The Renewable Energy Wildlife Institute (REWI) was appointed as the prime awardee of DOE award number DE-EE0007883 to lead a team of scientists, wind developers, and technology manufacturers toward the overarching goal of evaluating the effectiveness of the current DTBird system in minimizing the risk of golden eagles (Aquila chrysaetos) and other large soaring raptors from approaching the rotor-swept zone (RSZ) of operating wind turbines. As part of this goal, the team set out to 1) quantify the expected reduction in collision risk for golden eagles from operation of the detection and deterrence modules in a manner that supports the approach used by the U.S. Fish and Wildlife Service (USFWS) to assess and credit facility operators for their efforts to minimize predicted collision fatalities and 2) provide information to help improve the technology to maximize its effectiveness. DTBird is an automated detection and audio deterrent system created by the Spanish company Liquen, designed to discourage birds from entering the RSZ of spinning wind turbines. The system uses cameras to automatically detect airborne targets of interest, records each such event in an online database, and triggers a warning signal (loud sound) if the tracked object has moved close to the turbine. If the object moves even closer to the RSZ, a more aggressive dissuasion signal is broadcast. To meet our objectives, the team conducted a two-year experiment at the Goodnoe Hills wind facility in Washington state, in which 14 turbines were outfitted with DTBird units. Daily, each DTBird-equipped turbine was randomly assigned to a control or treatment group. Treatment turbines operated with DTBird running as intended—broadcasting warning or deterrent signals when DTBird detected a target within range. On control turbines, no sound signals were broadcast if a moving target triggered the DTBird system. The team also flew unmanned aerial vehicles (UAVs) designed to coarsely mimic the general size, weight, and coloration of golden eagles in programmed flight transects across DTBird detection ranges to quantify DTBird’s ability to detect intended targets and to evaluate factors that influence the probability of detection and DTBird’s response distances. Additionally, the team evaluated the behavioral responses of in situ eagles exposed to spinning turbines alone (visual and sound influences) versus spinning turbines plus broadcasted DTBird audio deterrents, to estimate the effectiveness of deterrence by the DTBird system. The data and results from these investigations were combined with those from a pilot study conducted at the Manzana Wind Power Project in California to better evaluate DTBird’s effectiveness across different landscapes.

17 WIND ENERGY↗

Multi-point, high-speed passive ion velocity distribution diagnostic on the Pegasus Toroidal Experiment

A passive ion temperature polychromator has been deployed on Pegasus to study power balance and non-thermal ion distributions that arise during point source helicity injection. Spectra are recorded from a 1 m F/8.6 Czerny-Turner polychromator whose output is recorded by an intensified high-speed camera. The use of high orders allows for a dispersion of 0.02 A/mm in 4th order and a bandpass of 0.14 A ({approx}13 km/s) at 3131 A in 4th order with 100 {mu}m entrance slit. The instrument temperature of the spectrometer is 15 eV. Light from the output of an image intensifier in the spectrometer focal plane is coupled to a high-speed CMOS camera. The system can accommodate up to 20 spatial points recorded at 0.5 ms time resolution. During helicity injection, stochastic magnetic fields keep T{sub e} low ({approx}100 eV) and thus low ionization impurities penetrate to the core. Under these conditions, high core ion temperatures are measured (T{sub i} Almost-Equal-To 1.2 keV, T{sub e} Almost-Equal-To 0.1 keV) using spectral lines from carbon III, nitrogen III, and boron IV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗