Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Ground and In-Flight Calibration of the OSIRIS-REx Camera Suite

The OSIRIS-REx Camera Suite (OCAMS) onboard the OSIRIS-REx spacecraft is used to study the shape and surface of the mission’s target, asteroid (101955) Bennu,in support of the selection of a sampling site. We present calibration methods and results for the three OCAMS cameras—MapCam, PolyCam, and SamCam—using data from pre-flight and in-flight calibration campaigns. Pre-flight calibrations established a baseline fora variety of camera properties, including bias and dark behavior, flat fields, stray light, and radiometric calibration. In-flight activities updated these calibrations where possible, allowing us to confidently measure Bennu’s surface. Accurate calibration is critical not only for establishing a global understanding of Bennu, but also for enabling analyses of potential sampling locations and for providing scientific context for the returned sample.

E Mazarico↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

Operational support for Upper Atmosphere Research Satellite (UARS) attitude sensors

The Upper Atmosphere Research Satellite (UARS) has several sensors that can provide observations for attitude determination: star trackers, Sun sensors (gimbaled as well as fixed), magnetometers, Earth sensors, and gyroscopes. The accuracy of these observations is important for mission success. Analysts on the Flight Dynamics Facility (FDF) UARS Attitude task monitor these data to evaluate the performance of the sensors taking corrective action when appropriate. Monitoring activities range from examining the data during real-time passes to constructing long-term trend plots. Increasing residuals (differences) between the observed and expected quantities is a prime indicator of sensor problems. Residual increases may be due to alignment shifts and/or degradation in sensor output. Residuals from star tracker data revealed and anomalous behavior that contributes to attitude errors. Compensating for this behavior has significantly reduced the attitude errors. This paper discusses the methods used by the FDF UARS attitude task for maintenance of the attitude sensors, including short- and long-term monitoring, trend analysis, and calibration methods, and presents the results obtained through corrective action.

Lee, M.↗

Dual Ion Spectrometers and Their Calibration for the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

The scientific target of NASA's Magnetospheric Multiscale (MMS) mission is to study the fundamentally important phenomenon of magnetic reconnection. Theoretical models of this process predict a small size, on the order of hundred kilometers, for the ion diffusion region where ions are demagnetized at the dayside magnetopause. This region may typically sweep over the spacecraft at relatively high speeds of 50 km/s, requiring the fast plasma investigation (FPI) instrument suite to have an extremely high time resolution for measurements of the 3D particle distribution functions. As part of the FPI on MMS, the 16 dual ion spectrometers (DIS) will provide fast (150 ms) 3D ion velocity distributions, from 10 to 30,000 eV/q, by combining the measurements from four dual spectrometers on each of four MMS spacecraft. For any multispacecraft mission, the response uniformity among the spectrometer set assumes an enhanced importance. Due to these demanding instrument requirements and the effort of calibrating more than 32 sensors (16 × 2) within a tight schedule, a highly systematic and precise calibration was required for measurement repeatability. To illustrate how this challenge was met, a brief overview of the FPI DIS was presented with a detailed discussion of the calibration method of approach and implementation. Finally, a discussion of DIS performance results, their unit-to-unit variation, and the lessons learned from this calibration effort are presented.

Coffey, V. N.↗

Calibration Designs for Non-Monolithic Wind Tunnel Force Balances

This research paper investigates current experimental designs and regression models for calibrating internal wind tunnel force balances of non-monolithic design. Such calibration methods are necessary for this class of balance because it has an electrical response that is dependent upon the sign of the applied forces and moments. This dependency gives rise to discontinuities in the response surfaces that are not easily modeled using traditional response surface methodologies. An analysis of current recommended calibration models is shown to lead to correlated response model terms. Alternative modeling methods are explored which feature orthogonal or near-orthogonal terms.

Wind tunnel models↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗

The AGORA High-resolution Galaxy Simulations Comparison Project. III. Cosmological Zoom-in Simulation of a Milky Way–mass Halo

In this work, we present a suite of high-resolution cosmological zoom-in simulations to z = 4 of a 10 12 M⊙ halo at z = 0, obtained using seven contemporary astrophysical simulation codes (Art-I, Enzo, Ramses, Changa, Gadget-3, Gear, and Gizmo) widely used in the numerical galaxy formation community. The physics prescriptions for gas cooling and heating and star formation are the same as the ones used in our previous Assembling Galaxies of Resolved Anatomy (AGORA) disk comparison but now account for the effects of cosmological processes such as the expansion of the universe, intergalactic gas inflow, and the cosmic ultraviolet background radiation emitted by massive stars and quasars. In this work, we introduce the most careful comparison yet of galaxy formation simulations run by different code groups, together with a series of four calibration steps each of which is designed to reduce the number of tunable simulation parameters adopted in the final run. In the first two steps, we methodically calibrate the gas physics, such as cooling and heating, in simulations without star formation. In the third step, we seek agreement on the total stellar mass produced with the common star formation prescription used in the AGORA disk comparison, in stellar-feedback-free simulations. In the last calibration step, we activate stellar feedback, where each code group is asked to set the feedback prescription to as close to the most widely used one in its code community as possible, while aiming for convergence in the stellar mass at z = 4 to the values predicted by semiempirical models. After all the participating code groups successfully complete the calibration steps, we achieve a suite of cosmological simulations with similar mass assembly histories down to z = 4. With numerical accuracy that resolves the internal structure of a target halo (≲100 physical pc at z = 4), we find that the codes overall agree well with one another, e.g., in gas and stellar properties, but also show differences, e.g., in circumgalactic medium (CGM) properties. We argue that, if adequately tested in accordance with our proposed calibration steps and common parameters, high-resolution cosmological zoom-in simulations can have robust and reproducible results. New code groups are invited to join and enrich this comparison by generating equivalent models or to test the code's compatibility on their own, by adopting the common initial conditions, the common easy-to-implement physics package, and the proposed calibration steps. Further analyses of the zoom-in simulations presented here will be presented in forthcoming reports from the AGORA Collaboration, including studies of the CGM, simulations by additional codes, and results at lower redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser-induced incandescence calibration via gravimetric sampling

Absolute calibration of laser-induced incandescence (LII) is demonstrated via comparison of LII signal intensities with gravimetrically determined soot volume fractions. This calibration technique does not rely upon calculated or measured optical characteristics of soot. The variation of the LII signal with gravimetrically measured soot volume fractions ranging from 0.078 to 1.1 ppm established the linearly of the calibration. With the high spatial and temporal resolution capabilities of laser-induced incandescence (LII), the spatial and temporal fluctuations of the soot field within a gravimetric chimney were characterized. Radial uniformity of the soot volume fraction, f(sub v) was demonstrated with sufficient averaging of the single laser-shot LII images of the soot field thus confirming the validity of the calibration method for imaging applications. As illustration, instantaneous soot volume fractions within a Re = 5000 ethylene/air diffusion flame measured via planar LII were established quantitatively with this calibration.

Choi, M. Y.↗

Cross Calibration and Validation Using CLARREO

The presentation focuses on study questions, effort, and result. Study questions include a focus on MW/LW, error sources and what can be expected, how validation will be performed and what resolution is required, and spatial resolution required for cross-calibration. Study effort includes empirical approach by examining AIRS ,IASI and MODIS cross-calibration methods already in place and estimate the number of clear and Dome C observations possible versus spatial resolution. Study results include 5000 sampler per cross-calibration recommended, insufficient cloud free and Dome C AWS observations for cross calibration and validation at 100km, and less than 20 km IFOV at 100 km swath needed to achieve sufficient samples for cross-calibration of CLARREO.

calibration↗

Reliable Power Rating of Perovskite PV Modules: Preprint

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group’s steady-state performance calibration protocol (i.e., Asymptotic PMAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic PMAX. Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Method and Apparatus for Spacecraft Gyroscope Scale Factor Calibration

A method and apparatus for estimating gyro scale factor during normal spacecraft operations, using small attitude motions that are compliant with mission pointing accuracy and stability requirements and a signal processing method that specifically detects the intentionally induced motions. This process increases operational availability by avoiding the need to take the spacecraft offline for large calibration maneuvers.

Reth, Alan D↗

Hand-Eye Calibration Using Active Vision

The project described in this paper designed and implemented a hand-eye calibration method for manipulators under observation by stereo cameras. This method has been utilized on Johnson Space Center's Robonaut, and on a planetary manipulator mock-up at the Jet Propulsion Laboratory. The intent of this calibration is to improve the manipulator's hand-eye coordination.

manipulation↗

Soil Moisture Active Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude. Since April, 2015, the radiometer is under calibration and validation to assess the quality of the radiometer L1B data product. Calibration methods including the SMAP L1B TA2TB (from Antenna Temperature (TA) to the Earth's surface Brightness Temperature (TB)) algorithm and TA forward models are outlined, and validation approaches to calibration stability/quality are described in this paper including future work. Results show that the current radiometer L1B data satisfies its requirements.

simulation↗

Soil Moisture ActivePassive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude. Since April, 2015, the radiometer is under calibration and validation to assess the quality of the radiometer L1B data product. Calibration methods including the SMAP L1B TA2TB (from Antenna Temperature (TA) to the Earth’s surface Brightness Temperature (TB)) algorithm and TA forward models are outlined, and validation approaches to calibration stability/quality are described in this paper including future work. Results show that the current radiometer L1B data satisfies its requirements.

radiometers↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Aero-Propulsion CFD Methodology for the Hyper-X Flight Experiment

Computational fluid dynamics (CFD) tools have been used extensively in the analysis and development of the X-43A Hyper-X Research Vehicle (HXRV). A significant element of this analysis is the prediction of integrated vehicle aero-propulsive performance, which includes an integration of aerodynamic and propulsion flow fields. This paper describes analysis tools used and the methodology for obtaining pre-flight predictions of longitudinal performance increments. The use of higher-fidelity methods to examine flow-field characteristics and scramjet flowpath component performance is also discussed. Limited comparisons with available ground test data are shown to illustrate the approach used to calibrate methods and assess solution accuracy. Inviscid calculations to evaluate lateral-directional stability characteristics are discussed. The methodology behind 3D tip-to-tail calculations is described and the impact of 3D exhaust plume expansion in the afterbody region is illustrated. Finally, future technology development needs in the area of hypersonic propulsion-airframe integration analysis are discussed.

Cockrell, Charles E., Jr.↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗