Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Multimodal sensor fusion framework for residential building occupancy detection

For several years now, smart building energy systems have been a research area of intensive activity. In light of the increasing need for sustainable buildings and energy systems, this trend motivates an increasing need for a solution to reduce carbon dioxide emissions and improve energy efficiency. This work proposes a high-performing and transferable occupancy detection framework that combines sensor data from different data modalities, including time series environmental data (temperature, humidity, and illuminance), image data, and acoustic energy data using ensemble method. To draw out the best prediction performance in each modality, the proposed framework was developed, including various models that were designed to learn the occupancy patterns reflected in the physical data streams. To tackle the time series environmental data, we designed two variants of an occupancy detection spatiotemporal pattern network (Occ-STPN) that performs both feature level and decision level fusion, respectively. We also propose a new metric; the fading memory mean square error (FMMSE), that provides a fair evaluation and penalization of delayed occupancy predictions. Multiple open-sourced datasets, including the Electricity Consumption and Occupancy and the University of California, Irvine's (UCI) building occupancy detection dataset, along with our own real data collected from six different houses, were used to validate the algorithms' performance. The experimental results presented herein break down the performance for each sensing modality, and a detailed analysis of the performance is also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process

Recent progress in sensing techniques and data analytics tools have significantly accelerated the development of Wire Arc Additive Manufacturing (WAAM) systems. This data centric approach emphasizes leveraging available data throughout the production process to optimize performance. Integration of extensive data analysis provides the opportunity to improve precision, reduce waste, and enhance the quality of produced parts. This method relies on AI/ML models and optimization techniques, which are developed using the data collected from various sources, including in-situ sensors, ex-situ imaging, and manufacturing process parameters. The quality and diversity of this data, along with the alignment between different data streams (achieved through spatiotemporal registration) are critical for the successful development of AI/ML and optimization models. In this work, we present a spatiotemporally registered dataset generated during the WAAM process of deposition of a rectangular block. The dataset includes the comprehensive description of deposition process, process parameters, in-situ collected welding characteristics, acoustic data, and X-Ray Computed Tomography analysis data for the build. Dataset A Co-Registered In-Situ and Ex-Situ Dataset of Electrical, Acoustic, and CT Characteristics from Wire Arc Additive Manufacturing Process has arisen under UT-Battelle, LLC’s Prime Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy (DOE) to manage and operate the Oak Ridge National Laboratory. UT-Battelle, LLC will not assert any rights under United States law or under the Prime Contract it has in the dataset against any user of the dataset, including any copyrights or patent rights. UT-Battelle, LLC requests that attribution to the dataset is provided as academically appropriate.

42 ENGINEERING↗

Commercial Energy Code Compliance – Just the Facts, Ma’am

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. This paper builds on the methodology presented at the 2016 Summer Study and provides a first glimpse of the results as seen in the field. The field study team has implemented the pilot methodology, compiling a data set of over 200 office and retail buildings in climate zones 2A and 5A. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This paper will review the findings of that analysis, discuss critical aspects of the methodology, such as sampling and recruitment strategies, and identify areas where the greatest return—bang for the buck—exists in improving compliance with codes in commercial buildings. In addition, the team will make specific recommendations for jurisdictions looking to use the methodology to maximize energy code savings achieved in the field.

Cheslak, Kimberly↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying Sample Provenance From SEM/EDS Automated Particle Analysis via Few-Shot Learning Coupled With Similarity Graph Clustering

Automated particle analysis (APA) provides a vast amount of compositional data via energy-dispersive X-ray spectroscopy along with size and shape data via scanning electron microscopy for individual particles in a sample. In many instances, APA data are leveraged to support identification of the source of a sample based on the detection of particles of a specific composition. Often, the particles that provide context make up a minuscule portion of the sample. Additionally, the interpretation of complex samples can be difficult due to the diversity of compositions both in the mixture and within a particle. In this work, we demonstrate a method to compute and cluster similarity graphs that describe inter-particle relationships within a sample using a multi-modal few-shot learning neural network. Here, as a proof-of-concept, we show that samples known to have been exposed to gunshot residue can be distinguished from samples occasionally mistaken for gunshot residue. Our workflow builds upon standard APA techniques and data processing methods to unveil additional information in a readily interpretable and quantitatively comparable format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Commercial Vehicle Electrification Evaluation Toolkit (CVEET)

The CVEET can identify and characterize charging and battery capacity challenges for class 3-8 commercial vehicle electrification, including battery electric and plug in hybrid vehicles for various trucks, vans and buses, over a wide range of vehicle operation. The tool can help build the understanding of the impact of commercial vehicle electrification on energy consumption, payload penalty, and GHG (i.e., CO2) emissions. The tool employs a quantitative approach to estimate electric vehicle energy consumption, characterize component performance and determine appropriate charging assumptions to conduct a comprehensive priority analysis of MD/HD vehicle electrification using public domain data.

Gao, Zhiming↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of charge control techniques on spacecraft thermal surfaces (electrostatic discharge study)

The charging and discharging characteristics of various dielectric materials commonly used on spacecraft were tested. The experimental apparatus and the calculations used to analyze the data generated during the testing are described. The test technique, results, and analysis used are presented. Indium tin oxide coated Teflon, Kapton, and quartz do not charge significantly. CTL 15 white paint shows no large charge build up. Pinholes in Teflon and Kapton increase the leakage through the sample and reduce the energy released in an arc. Conductive grids in Teflon and Kapton reduce the arc energy by two orders of magnitude over untreated samples. Extreme low temperatures (-195 C) do not significantly increase the arc energy of the gridded sample.

Robinson, P. A., Jr.↗

Creating Accurate Methane Emission Inventories through Data-Driven Airborne Survey Strategies

Because natural gas emits less carbon than other fossil fuels, it holds promise as a green energy transition fuel. However, the overall carbon footprint of natural gas is significantly elevated by methane emissions that occur during its production and transmission (Cusworth et al. 2022). Methane “super-emitters,” while comprising only about 1% of sites, are responsible for the majority of oil- and gas-sourced methane emissions, making their detection and mitigation critical in reducing the climate impact of natural gas and in meeting national and global sustainability goals (Sherwin et al. 2024). Yet, despite advancements in detection, significant uncertainties remain regarding the size, frequency, and duration distributions of methane emissions (e.g., Frankenberg et al. 2016, Cusworth et al. 2022, Chen, Sherwin et al. 2022, Conrad et al. 2023, Johnson et al. 2023, Sherwin et al. 2024) underscoring the need for comprehensive emissions inventories segmented by basin across the US. Airborne surveys are well-suited for collecting data to build these comprehensive, basin-level inventories because they allow for extensive spatial coverage, and have the spatial resolution, and the sensitivity to pinpoint individual methane sources. As remote sensing technologies enable rapid basin-scale surveys, it is imperative to establish scientifically and statistically robust standards to generate reliable and actionable emissions inventories. Recent work has shown that differences in airborne sampling strategies, detection technologies, and analysis can lead to large differences between survey conclusions if not correctly accounted for (Chen et al. 2024). This elevates the importance of incorporating proper sampling and analysis techniques when designing a methane emissions monitoring campaign to produce accurate results and facilitate cross-study comparisons. In this paper, we describe a survey strategy designed using the latest conclusions from the literature to align results from different aerial surveys. We identify several sampling and analysis principles, including large sample sizes, balanced sampling across oil and gas production, careful survey area definition, and a unified protocol for analysis, to be vital to producing an unbiased estimate of basin-scale emissions. We present results from a Department of Energy-funded project that deployed this survey strategy in two understudied oil and gas- producing regions in the United States: the Haynesville Basin in Texas and Louisiana, and the Woodford Shale in the Anadarko Basin in Oklahoma.

03 NATURAL GAS↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Quantum Machine Learning Applications in High-Energy Physics

Some of the most significant achievements of the modern era of particle physics, such as the discovery of the Higgs boson, have been made possible by the tremendous effort in building and operating large-scale experiments like the Large Hadron Collider or the Tevatron. In these facilities, the ultimate theory to describe matter at the most fundamental level is constantly probed and verified. These experiments often produce large amounts of data that require storing, processing, and analysis techniques that continually push the limits of traditional information processing schemes. Thus, the High-Energy Physics (HEP) field has benefited from advancements in information processing and the development of algorithms and tools for large datasets. More recently, quantum computing applications have been investigated to understand how the community can benefit from the advantages of quantum information science. Nonetheless, to unleash the full potential of quantum computing, there is a need to understand the quantum behavior and, thus, scale up current algorithms beyond what can be simulated in classical processors. In this work, we explore potential applications of quantum machine learning to data analysis tasks in HEP and how to overcome the limitations of algorithms targeted for Noisy Intermediate-Scale Quantum (NISQ) devices.

Delgado, Andrea↗

U.S. Department of Energy Collegiate Wind Competition 2025: Rules - Phases 2 and 3

The U.S. Department of Energy (DOE) Wind Energy Technologies Office's (WETO) Collegiate Wind Competition (CWC, also referred to as the "competition" in this rules document) invites interdisciplinary teams of undergraduate students from a variety of academic programs to solve complex wind energy challenges. Through the competition, WETO intends to offer students direct industry experience, valuable exposure to wind energy career pathways, and greater knowledge of wind energy's potential to contribute to a clean energy future. The competition will select up to 35 teams to start, making them eligible to compete for a cash prize pool of up to $280,000. Each year, the competition identifies a new challenge and set of activities that address real-world research questions, thus demonstrating skills that students will need to work in the wind or wider renewable energy industries. The Collegiate Wind Competition 2025 challenge requires participants to compete simultaneously in four contests: 1) Turbine Design Contest: Design, build, and present a unique, wind-driven power system. 2) Turbine Testing Contest: Test the wind turbine in a competition wind tunnel at the final event. 3) Project Development Contest: Research wind resource data, transmission infrastructure, and environmental factors to create a site plan and financial analysis for a hypothetical wind farm. 4) Connection Creation Contest: Partner with wind industry professionals, raise awareness of wind energy in your local community, and work with local media to promote your team's accomplishments. The competition does not prescribe a power system market or wind regime. It is expected that each team will participate in all four contests.

Collegiate Wind Competition↗

U.S. Department of Energy Collegiate Wind Competition 2025 Rules - Phase 1

The U.S. Department of Energy (DOE) Wind Energy Technologies Office's (WETO) Collegiate Wind Competition (CWC, also referred to as the "Competition" in this rules document) invites interdisciplinary teams of undergraduate students from a variety of academic programs to solve complex wind energy challenges. Through the competition, WETO intends to offer students direct industry experience, valuable exposure to wind energy career pathways, and greater knowledge of wind energy's potential to contribute to a clean energy future. The competition will select up to 35 teams to start, making them eligible to compete for a cash prize pool of up to $280,000 . Each year, the competition identifies a new challenge and set of activities that address real-world research questions, thus demonstrating skills that students will need to work in the wind or wider renewable energy industries. The Collegiate Wind Competition 2025 challenge requires participants to compete simultaneously in four contests: 1) Turbine Prototype Contest: Design, build, and present a unique, wind-driven power system based on market research; 2) Turbine Testing Contest: Test the wind turbine in a competition wind tunnel at the final event; 3) Project Development Contest: Research wind resource data, transmission infrastructure, and environmental factors to create a site plan and financial analysis for a hypothetical wind farm; and Connection Creation Contest: Partner with wind industry professionals, raise awareness of wind energy in your local community, and work with local media to promote your team's accomplishments. The competition does not prescribe a power system market or wind regime. It is expected that each team will participate in all four contests.

collegiate wind competition↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗