Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Beam current effect as a potential challenge in SEM-EBSD in situ tensile testing

Highlights: • In situ SEM-EBSD tensile tests were conducted using 304L steels with 8 and 10.4% Ni. • KAM and GROD evolution, twinning, and phase instability were investigated. • Phase transformation in 8% Ni-steel was sensitive to the electron beam current. In situ mechanical tensile tests coupled with electron backscatter diffraction (EBSD) analysis were conducted using specimens of two 304L steels with ~8 and 10.4% Ni content, respectively. Twinning was observed in steel with 10.4% Ni content, whereas steel with 8% Ni content demonstrated martensitic transformation. Testing showed that the kinetics of martensitic transformation in steel with 8% Ni content was influenced by the electron beam current used during EBSD scans. Continuous scanning using 32 nA nominal beam current led to suppression of the phase instability in the near-surface layer, but acceptable comparable-to-the-bulk results were obtained using 8 nA beam current. The exact mechanism of the beam current role is unclear, but it appears to be neutral regarding Kernel Average Misorientation behavior and deformation-induced twinning.

36 MATERIALS SCIENCE↗

The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC

Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uniform Beam Distributions Of Charged Particle Beams

The use of octupole elements was originally suggested [1] to transform the transverse Gaussian distribution of a charged particle beam into a uniform beam distribution having rectangular cross section. The first experimental realization of this concept was materialized at the Radiation Effects Facility (REF) of the Brookhaven National Laboratory (BNL)[2] where the transverse Gaussian distribution of a 200 MeV H{sup -} beam was transformed into a rectangular uniform distribution. Later, the beam line of the NASA Space Radiation Laboratory (NSRL) facility [3,4] built at BNL, was specifically designed to generate uniform beam distributions with rectangular cross sections, in both, the horizontal and vertical directions, at the location of the target. The NSRL facility generates uniform beam distributions of various nuclear species, which may vary in energy, and also vary in size of the uniform beam distribution. We will present an overview of the method to generate uniform beam distributions, show some results from the NSRL facility, and suggest other possibilities for generating such beam distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complex source beam: A tool to describe highly focused vector beams analytically

The scalar-complex-source model is used to develop an accurate description of highly focused radially, azimuthally, linearly, and circularly polarized monochromatic vector beams. We investigate the power and full beam widths at half maximum of vigorous Maxwell equation solutions. The analytical expressions are employed to compare the vector complex source beams with the real beams produced by various high-numerical-aperture (NA) focusing systems. We find a parameter set for which the spatial extents of the analytical beams are the same as those of experimentally realized ones. We ensure the same shape of the considered beams by investigating an overlap of the complex source beams with high-NA beams. We demonstrate that the analytical expressions are good approximations for realistic highly focused beams.

43 PARTICLE ACCELERATORS↗

Long-Range Beam-Beam Compensation in RHIC

In order to avoid the effects of long-range beam-beam interactions which produce beam blow-up and deteriorate beam life time, a compensation scheme with current carrying wires has been proposed. Two long-range beam-beam compensators were installed in RHIC rings in 2006. The effects of the compensators have been experimentally investigated. An indication was observed that the compensators are beneficial to beam life time in measurements performed in RHIC during 2009. In this paper, we report the effects of wire compensator on beam loss and emittance for proton-proton beams at collision energy.

43 PARTICLE ACCELERATORS↗

High-intensity ion sources for accelerators with emphasis on H{sup -} beam formation and transport (invited)

This paper lays out the fundamental working principles of a variety of high-current ion sources for accelerators in a tutorial manner, and gives examples of specific source types such as dc discharge-driven and rf-driven multicusp sources, Penning-type, and electron cyclotron resonance-based sources while discussing those principles, pointing out general performance limits as well as the performance parameters of specific sources. Laser-based, two-chamber, and surface-ionization sources are briefly mentioned. Main aspects of this review are particle feed, ionization mechanism, beam formation, and beam transport. Issues seen with beam formation and low-energy transport of negative hydrogen-ion beams are treated in detail.

43 PARTICLE ACCELERATORS↗

H{sup -} beam transport experiments in a solenoid low energy beam transport

The Front End Test Stand (FETS) is located at Rutherford Appleton Laboratory and aims for a high current, fast chopped 3 MeV H{sup -} ion beam suitable for future high power proton accelerators like ISIS upgrade. The main components of the front end are the Penning ion source, a low energy beam transport line, an radio-frequency quadrupole (RFQ) and a medium energy beam transport (MEBT) providing also a chopper section and rebuncher. FETS is in the stage of commissioning its low energy beam transport (LEBT) line consisting of three solenoids. The LEBT has to transport an H{sup -} high current beam (up to 60 mA) at 65 keV. This is the injection energy of the beam into the RFQ. The main diagnostics are slit-slit emittance scanners for each transversal plane. For optimizing the matching to the RFQ, experiments have been performed with a variety of solenoid settings to better understand the actual beam transport. Occasionally, source parameters such as extractor slit width and beam energy were varied as well. The paper also discusses simulations based on these measurements.

43 PARTICLE ACCELERATORS↗

Quantitative comparison of self-healing ability between Bessel–Gaussian beam and Airy beam

The self-healing ability during propagation process is one of the most important properties of non-diffracting beams. This ability has crucial advantages to light sheet-based microscopy to reduce scattering artefacts, increase the quality of the image and enhance the resolution of microscopy. Based on similarity between two infinite-dimensional complex vectors in Hilbert space, the ability to a Bessel–Gaussian beam and an Airy beam have been studied and compared. Comparing the evolution of the similarity of Bessel–Gaussian beam with Airy beam under the same conditions, we find that Bessel–Gaussian beam has stronger self-healing ability and is more stable than that of Airy beam. To confirm this result, the intensity profiles of Bessel–Gaussian beam and Airy beam with different similarities are numerically calculated and compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation and characterization of magnetized electron beam from a DC high voltage photogun for electron beam cooling application

One of the most challenging requirements for the proposed Electron-Ion Collider is the strong cooling of the proton beam, which is key to achieving the collider’s desired luminosity of order 10 33 -10 34 cm -2 s -1 . Magnetized bunched-beam electron cooling could be a means to achieve the required high luminosity, where strong cooling is accomplished inside a cooling solenoid where the ions co-propagate with an electron beam generated from a source immersed in a magnetic field. To increase the cooling efficiency, a bunched electron beam with high bunch charge and high repetition rate is required. This work describes the production and characterization of magnetized electron beam using a compact 300 kV DC high voltage photogun and bi-alkali antimonide photocathode. Beam magnetization was studied using a diagnostic beamline that includes viewer screens for measuring the shearing angle of the electron beamlet passing through a narrow upstream slit. Simulations and corresponding measurements of beam magnetization are presented as a function of laser spot size and magnetic field strength. Correlated beam emittance with magnetic field (0–0.15 T) at the photocathode was measured for various laser spot sizes. Measurements of photocathode lifetime were carried out at different magnetized electron beam currents up to 28 mA, and bunch charge up to 0.7 nC (not simultaneously).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam emittance preservation using Gaussian density ramps in a beam-driven plasma wakefield accelerator

A current challenge that is facing the plasma wakefield accelerator (PWFA) community is transverse beam emittance preservation. This can be achieved by balancing the natural divergence of the beam against the strong focusing force provided by the PWFA plasma source in a scheme referred to as beam matching. One method to accomplish beam matching is through the gradual focusing of a beam with a plasma density ramp leading into the bulk plasma. Here, the beam dynamics in a Gaussian plasma density ramp are considered, and an empirical formula is identified that gives the ramp length and beam vacuum waist location needed to achieve near-perfect matching. The method uses only the beam vacuum waist beta function as an input. Numerical studies show that the Gaussian ramp focusing formula is robust for beta function demagnification factors spanning more than an order of magnitude with experimentally favourable tolerances for future PWFA research facilities. This article is part of the Theo Murphy meeting issue ‘Directions in particle beam-driven plasma wakefield acceleration’.

43 PARTICLE ACCELERATORS↗

Compressed Streak Imaging Beam Diagnostic

We are planning a new beam diagnostic based on Compressed Ultrafast Photography (CUP)1.A foil inserted in the beam path is used to generate a continuous optical image of the beam, which is the same technique used on the existing DARHT II beam imaging diagnostic. This existing diagnostic compresses the beam image with anamorphic lenses into four views that are streaked simultaneously on two streak cameras. In our new beam diagnostic design the anamorphic lenses are replaced with regular lenses and the beam image is stamped with a pseudo-random mask pattern. The full image is imaged onto a streak camera with its entrance slit expanded. Modifying the CUP technique, which uses a single streaked image, our design splits the image into four rotated copies and puts all four images on two streak cameras. A data cube of multiple image frames is reconstructed from the streak camera data through the use of the TwiST algorithm2 combined with total variation denoising3. The additional rotated images improve spatial resolution and reduce noise and image artifacts compared to using a single streaked image. In reconstructions of simulated data, fine detail in the beam profile can be seen and there is a remarkable absence of image artifacts compared to the existing DARHT II beam imaging diagnostic. Performance was evaluated using a pseudo-MTF derived from a simulated wave pattern test object.

Marks, Daniel G.↗

Beam commissioning and measurements validating the beam model in a new TPS that converts helical tomotherapy plans to step-and-shoot IMRT plans

Purpose: A new type of treatment planning system called SHAREPLAN has been studied, which enables the transfer of treatment plans generated for helical tomotherapy delivery to plans that can be delivered on C-arm linacs. The purpose is to ensure continuous patient treatment during periods of unscheduled downtime for the TomoTherapy unit, particularly in clinics without a backup unit. The purpose of this work was to verify that the plans generated in this novel planning system are deliverable and accurate. The work consists primarily of beam commissioning, verification of the beam model, and measurements verifying that generated plans are deliverable with sufficient accuracy. Methods: The beam commissioning process involves input of general geometric properties of the modeled linac, profiles and depth dose curves for a specific photon nominal energy (6 MV), and the automated modeling of other beam properties. Some manual tuning of the beam model is required. To evaluate its accuracy, the confidence limit concept [J. Venselaar et al., ''Tolerances for the accuracy of photon beam dose calculations of treatment planning systems,'' Radiother. Oncol. 60, 191-201 (2001)] was used, which is a method supported by ESTRO. Measurements were conducted with a 2D diode array at the commissioned linac as a final check of the beam model and to evaluate whether the generated plans were deliverable and accurate. Results: The comparison and evaluation of calculated data points and measured data according to the method applied confirmed the accuracy of the beam model. The profiles had a confidence limit of 1.1% and the depth dose curves had a confidence limit of 1.7%, both of which were well below the tolerance limit of 2%. Plan specific QC measurements and evaluation verified that different plans generated in the TPS were deliverable with sufficient accuracy at the commissioned linac, as none of the 160 beams for the 20 different plans evaluated had a fraction of approved data points below 90%, the local clinical approval criterion for delivery QA measurements. Conclusions: This study is a validation of the new TPS as it verifies that the generated plans are deliverable at a commissioned linac with adequate accuracy. A thorough investigation of the treatment plan quality will require a separate study. The TPS is proving to be a useful and time-saving complement, especially for clinics having a single unit for helical delivery among its conventional linacs.

43 PARTICLE ACCELERATORS↗

SU-E-T-153: Burst-Mode Modulated Arc Therapy with Flattening-Filter-Free Beams Versus Flattening-Filtered Beams

Purpose: To compare the dosimetry and delivery of burst-mode modulated arc radiotherapy using flattening-filter-free (FFF) and flattening-filtered (FF) beams. Methods: Burst-mode modulated arc therapy (mARC, Siemens) plans were generated for six prostate cases with FFF and FF beam models, using the Elekta Monaco v. 5.00 planning system. One 360-degree arc was used for five cases, and for one case two 360-degree coplanar arcs were used. The maximum number of optimization points (OPs) per arc was set to 91, and OPs with less than 4 MU were disregarded. All plans were delivered on the Siemens Artiste linear accelerator with 6MV FF (300 MU/min) and comparable-energy FFF (2000 MU/min, labeled as 7UF) beams. Results: For all cases studied, the plans with FFF beams exhibited DVHs for the PTV, rectum, and bladder that were nearly identical to those for the plans with FF beams. The FFF plan yielded reduced dose to the right femoral head for 5 cases, and lower mean dose to the left femoral head for 4 cases. For all but the two-arc case, the FFF and FF plans resulted in an identical number of segments. The total number of MUs was slightly lower for the FF plans for five cases. The total delivery time per fraction was substantially lower for the FFF plans, ranging from 25 to 50 percent among all cases, as compared to the FF plans. Conclusion: For mARC plans, FFF and FF beams provided comparable PTV coverage and rectum and bladder sparing. For the femoral heads, the mean dose was slightly lower in most cases when using the FFF beam. Although the flat beam plans typically required slightly fewer MUs, FFF beams required substantially less time to deliver a plan of similar quality. This work was supported by Siemens Medical Solutions and the MCW Cancer Center Fotsch Foundation.

60 APPLIED LIFE SCIENCES↗

eRHIC ring-ring design with head-on beam-beam compensation

The luminosity of the eRHIC ring-ring design is limited by the beam-beam effect exerted on the electron beam. Recent simulation studies have shown that the beam-beam limit can be increased by means of an electron lens that compensates the beam-beam effect experienced by the electron beam. This scheme requires proper design of the electron ring, providing the correct betatron phase advance between interaction point and electron lens. We review the performance of the eRHIC ring-ring version and discuss various parameter sets, based on different cooling schemes for the proton/ion beam.

43 PARTICLE ACCELERATORS↗

Compact electrostatic beam optics for multi-element focused ion beams: Simulation and experiments

Electrostatic beam optics for a multi-element focused ion beam (MEFIB) system comprising of a microwave multicusp plasma (ion) source is designed with the help of two widely known and commercially available beam simulation codes: AXCEL-INP and SIMION. The input parameters to the simulations are obtained from experiments carried out in the system. A single and a double Einzel lens system (ELS) with and without beam limiting apertures (S) have been investigated. For a 1 mm beam at the plasma electrode aperture, the rms emittance of the focused ion beam is found to reduce from {approx}0.9 mm mrad for single ELS to {approx}0.5 mm mrad for a double ELS, when S of 0.5 mm aperture size is employed. The emittance can be further improved to {approx}0.1 mm mrad by maintaining S at ground potential, leading to reduction in beam spot size ({approx}10 {mu}m). The double ELS design is optimized for different electrode geometrical parameters with tolerances of {+-}1 mm in electrode thickness, electrode aperture, inter electrode distance, and {+-}1{sup o} in electrode angle, providing a robust design. Experimental results obtained with the double ELS for the focused beam current and spot size, agree reasonably well with the simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Negative Hydrogen Ion Source for Spatial Beam Profile Measurement of a High Intensity Positive Ion Beam

We have been developing a negative hydrogen ion (H{sup -} ion) source for a spatial beam profile monitor of a high intensity positive ion beam as a new diagnostic tool. In case of a high intensity continuous-wave (CW) deuteron (D{sup +}) beam for the International Fusion Materials Irradiation Facility (IFMIF), it is difficult to measure the beam qualities in the severe high radiation environment during about one-year cyclic operation period. Conventional techniques are next to unusable for diagnostics in the operation period of about eleven months and for maintenance in the one-month shutdown period. Therefore, we have proposed an active beam probe system by using a negative ion beam and started an experimental study for the proof-of-principle (PoP) of the new spatial beam profile monitoring tool. In this paper, we present the status of development of the H{sup -} ion source as a probe beam source for the PoP experiment.

43 PARTICLE ACCELERATORS↗

Effect of subdominant species on the evolution of intense primary beam in a low energy beam transport line

The dynamics of space-charge-dominated multispecies beam with different distributions has been studied in a solenoid based low energy beam transport line using a particle-in-cell simulation method. Results are presented in wide parameter regimes covering emittance dominated as well as space charge dominated multispecies beams consisting of p, H{sub 2}{sup +}, and H{sub 3}{sup +} beams. Simulation shows the formation of hollow distribution of H{sub 2}{sup +} and H{sub 3}{sup +} beams around the desired proton beam and separation is more distinct as the fraction of proton is increased. The hollow formation is almost independent of combination of H{sub 2}{sup +} and H{sub 3}{sup +} beams, once the fraction of proton beam is fixed. The emittance growth of proton is found to increase sharply in the space-charge-dominated regime and is more in the cases where proton fraction is low.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of a radial self-field diode geometry for intense pulsed ion beam generation at 6 MeV on Hermes III

We investigate the generation of intense pulsed focused ion beams at the 6 MeV level using an inductive voltage adder (IVA) pulsed-power generator, which employs a magnetically insulated transmission line (MITL). Such IVA machines typical run at an impedance of few tens of Ohms. Previous successful intense ion beam generation experiments have often featured an “axial” pinch-reflex ion diode (i.e., with an axial anode-cathode gap) and operated on a conventional Marx generator/water line driver with an impedance of a few Ohms and no need for an MITL. The goals of these experiments are to develop a pinch-reflex ion diode geometry that has an impedance to efficiently match to an IVA, produces a reasonably high ion current fraction, captures the vacuum electron current flowing forward in the MITL, and focuses the resulting ion beam to small spot size. A new “radial” pinch-reflex ion diode (i.e., with a radial anode-cathode gap) is found to best demonstrate these properties. Operation in both positive and negative polarities was undertaken, although the negative polarity experiments are emphasized. Particle-in-cell (PIC) simulations are consistent with experimental results indicating that, for diode impedances less than the self-limited impedance of the MITL, almost all of the forward-going IVA vacuum electron flow current is incorporated into the diode current. PIC results also provide understanding of the diode-impedance and ion-focusing properties of the diode. In addition, a substantial high-energy ion population is also identified propagating in the “reverse” direction, i.e., from the back side of the anode foil in the electron beam dump.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗