At least 235 records · Page 13

Crystal Collimation Studies at the Tevatron (T-980)

Bent-crystal channeling is a technique with a potential to increase beam-halo collimation efficiency in high-energy colliders. First measurements at the Tevatron in 2005 have shown that using a thin silicon crystal to deflect the 1-TeV proton beam halo onto a secondary collimator improves the system performance by reducing the machine impedance, beam losses in the collider detectors and irradiation of the superconducting magnets, all in agreement with simulations. Recent results, obtained with an improved goniometer and enhanced beam diagnostics, are reported here for dedicated beam studies and first full collider stores along with simulation results and plans for substantial enhancement of the T-980 experimental setup.

43 PARTICLE ACCELERATORS↗

Investigations on the structure of the extracted ion beam from an electron cyclotron resonance ion source

Using improved beam diagnostic tools, the structure of an ion beam extracted from an electron cyclotron resonance ion source (ECRIS) becomes visible. Especially viewing targets to display the beam profile and pepper pot devices for emittance measurements turned out to be very useful. On the contrary, diagnostic tools integrating over one space coordinate like wire harps for profile measurements or slit-slit devices, respectively slit-grid devices to measure the emittance might be applicable for beam transport investigations in a quadrupole channel, but are not very meaningful for investigations regarding the given ECRIS symmetry. Here we try to reproduce the experimentally found structure on the ion beam by simulation. For the simulation, a certain model has to be used to reproduce the experimental results. The model is also described in this paper.

43 PARTICLE ACCELERATORS↗

Mirascope Luminescent Beam Profile Monitor

Advanced beam diagnostics are essential for reliable operation of high-performance accelerators and the intense beams produced by them. Non-invasive diagnostics can be used continuously with intense beams, while invasive techniques interfere with the beams and distort the beam profiles. In addition, traditional solid-based beam monitoring instrumentation produces unacceptable levels of radiation operating in high power beam environments. Noninvasive determination of accelerated particle distributions and profiles is the most difficult task of bunch diagnostics. Muons, Inc. proposed to develop non-interfering residual-gas beam profile monitors for transfer lines with pulse-to-pulse precision of better than 0.1 mm in position and size that will operate over a wide range of proton beam intensities including those needed for multi-MW beams of future facilities. The approach was to develop a low mass residual-gas profile monitor, where beam induced fluorescence (BIF) will be used to monitor the beam profile. An original scheme of light collection using a mirascope, an optical device invented in the 16th century, is proposed. The gas composition and pressure in the beam pipe are locally controlled to minimize unwanted radiation and to improve resolution.

43 PARTICLE ACCELERATORS↗

The Multi Optical Transition Radiation System

The determination and monitoring of the transverse phase space in ATF2 is crucial in order to meet their performances specifications. Since the beam sizes at the Interaction Point (IP) depend strongly on the aberrations in the Final Focus System (FFS), accurate measurement upstream of the FFS is required to tune the beam sizes at the IP. The beam sizes as well as the emittance are measured in several locations in the beam diagnostic section of the Extraction Line (EXT line) of ATF2. The vertical beam sizes in the diagnostic section are of the order of 10 {mu}m this means that the devices have to image spot sizes as small as 5 {mu}m, with 10% accuracy a 2 {mu}m resolution device is necessary. The ATF2 EXT line is a beam line with low power and low repetition rate that make usable devices using solid targets. In contrast to a ring machine, where an individual bunch can be measured many times as it passes around the ring, the beam size and the emittance measurement in the LC or in the beam lines have to be performed in a single pass. This requires that the wire scan device types (laser or solid) sample across successive bunches within a train, often with an over-estimation of the beam size due to beam position and intensity jitter, and can take up to half a minute to complete the measurement. Although some of these effects could be corrected, as the jitter effect could be subtracted by using the nearby BPMs signals, this can be avoided by using Optical Transition Radiation (OTR) Monitors. These monitors are based on the transition radiation effect, a light cone emitted when the charged particle crosses a metallic interface. This light is emitted in a specular fashion so it can be focused on to a CCD and produces an image of the beam. OTRs are able to take many fast measurements and therefore to measure the emittance with high statistics, giving a low error and a good understanding of the emittance jitter. In this article, simulations of the expected beam sizes and emittance, along with a technical description of the system, its hardware and software implementation are described. Additionally first measurement of the beam size and emittance of the Multi Optical Transition Radiation System located in the Extraction Line of ATF2 are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PARASITIC PROFILE MEASUREMENT OF 1 MW NEUTRON PRODUCTION BEAM AT SNS SUPERCONDUCTING LINAC

A laser wire system has been developed in the Spallation Neutron Source (SNS) superconducting linac (SCL). The SNS laser wire system has a capability of measuring profiles of an operational hydrogen ion beam at 9 cryomodule stations along the SCL by using a single light source. This talk reports our recent study of the laser wire profile measurement performance. Parasitic profile measurements have been conducted at multiple locations of SCL on an operational one-megawatt neutron production beam that SNS recently achieved as a new world record. We will also discuss novel beam diagnostics capabilities at the SNS SCL by using the laser wire system.

43 PARTICLE ACCELERATORS↗

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap↗

Plans for an Integrated Front-End Test Stand at the Spallation Neutron Source

A spare Radio-Frequency Quadrupole (RFQ) is presently being fabricated by industry with delivery to Oak Ridge National Laboratory planned in late 2012. The establishment of a test stand at the Spallation Neutron Source site is underway so that complete acceptance testing can be performed during the winter of 2012-2013. This activity is the first step in the establishment of an integrated front-end test stand that will include an ion source, low-energy beam transport (LEBT), RFQ, medium-energy beam transport, diagnostics, and a beam dump. The test stand will be capable of delivering an H- ion beam of up to 50 mA with a pulse length of 1 ms and a repetition rate of 60 Hz or a proton beam of up to 50 mA, 100us, 1Hz. The test stand will enable the following activities: complete ion source characterization; development of a magnetic LEBT chopper; development of a two-source layout; development of beam diagnostics; and study of beam dynamics of high intensity beam.

Champion, Mark S↗

Multi-GeV Electron Generation Using Texas Petawatt Laser

We present simulation results and experimental setup for multi-GeV electron generation by a laser plasma wake field accelerator (LWFA) driven by the Texas Petawatt (TPW) laser. Simulations show that, in plasma of density n{sub e} = 2-4x10{sup 17} cm{sup -3}, the TPW laser pulse (1.1 PW, 170 fs) can self-guide over 5 Rayleigh ranges, while electrons self-injected into the LWFA can accelerate up to 7 GeV. Optical diagnostic methods employed to observe the laser beam self-guiding, electron trapping and plasma bubble formation and evolution are discussed. Electron beam diagnostics, including optical transition radiation (OTR) and electron gamma ray shower (EGS) generation, are discussed as well.

43 PARTICLE ACCELERATORS↗

Compact Spreader Schemes

This paper describes beam distribution schemes adopting a novel implementation based on low amplitude vertical deflections combined with horizontal ones generated by Lambertson-type septum magnets. This scheme offers substantial compactness in the longitudinal layouts of the beam lines and increased flexibility for beam delivery of multiple beam lines on a shot-to-shot basis. Fast kickers (FK) or transverse electric field RF Deflectors (RFD) provide the low amplitude deflections. Initially proposed at the Stanford Linear Accelerator Center (SLAC) as tools for beam diagnostics and more recently adopted for multiline beam pattern schemes, RFDs offer repetition capabilities and a likely better amplitude reproducibility when compared to FKs, which, in turn, offer more modest financial involvements both in construction and operation. Both solutions represent an ideal approach for the design of compact beam distribution systems resulting in space and cost savings while preserving flexibility and beam quality.

43 PARTICLE ACCELERATORS↗

Linac4 low energy beam measurements with negative hydrogen ions

Linac4, a 160 MeV normal-conducting H{sup −} linear accelerator, is the first step in the upgrade of the beam intensity available from the LHC proton injectors at CERN. The Linac4 Low Energy Beam Transport (LEBT) line from the pulsed 2 MHz RF driven ion source, to the 352 MHz RFQ (Radiofrequency Quadrupole) has been built and installed at a test stand, and has been used to transport and match to the RFQ a pulsed 14 mA H{sup −} beam at 45 keV. A temporary slit-and-grid emittance measurement system has been put in place to characterize the beam delivered to the RFQ. In this paper a description of the LEBT and its beam diagnostics is given, and the results of beam emittance measurements and beam transmission measurements through the RFQ are compared with the expectation from simulations.

43 PARTICLE ACCELERATORS↗

Observation of electron cloud instabilities and emittance dilution at the Cornell electron-positron Storage ring Test Accelerator

Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnostics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains, 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this study we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions.

43 PARTICLE ACCELERATORS↗

A New Luminescence Beam Profile Monitor for Intense Proton and Heavy Ion Beams

A new luminescence beam profile monitor is realized in the polarized hydrogen gas jet target at the Relativistic Heavy Ion Collider (RHIC) facility. In addition to the spin polarization of the proton beam being routinely measured by the hydrogen gas jet, the luminescence produced by beam-hydrogen excitation leads to a strong Balmer series lines emission. A selected hydrogen Balmer line is spectrally filtered and imaged to produce the transverse RHIC proton beam shape with unprecedented details on the RHIC beam profile. Alternatively, when the passage of the high energy RHIC gold ion beam excited only the residual gas molecules in the beam path, sufficient ion beam induced luminescence is produced and the transverse gold ion beam profile is obtained. The measured transverse beam sizes and the calculated emittances provide an independent confirmation of the RHIC beam characteristics and to verify the emittance conservation along the RHIC accelerator. This optical beam diagnostic technique by making use of the beam induced fluorescence from injected or residual gas offers a truly noninvasive particle beam characterization, and provides a visual observation of proton and heavy ion beams. Combined with a longitudinal bunch measurement system, a 3-dimensional spatial particle beam profile can be reconstructed tomographically.

43 PARTICLE ACCELERATORS↗

Scorpius Accelerator Emittance Diagnostic Design

The 14th International Particle Accelerator Conference (IPAC’23) will be held in Venice, Italy from 7 to 12 May 2023 at the Venice Convention Centre. Website: https://www.ipac23.org/ Presenter: Mark Raphaelian Dear Mark, we acknowledge reception of your abstract #1268 for IPAC'23 - 14th International Particle Accelerator Conference. Here follow the details: Title: The Design of the Emittance Diagnostic for the Scorpius Accelerator Classification: MC6.T03: Beam Diagnostics and Instrumentation Type of presentation: Poster Presentation Submitter: Mark Raphaelian Authors: Mark Raphaelian Co-Authors: Daniel Dzenitis, Franz Weber, Nathaniel Pogue, Sean Littleton, Steven Falabella, Patrick Duffy, William Stem

47 OTHER INSTRUMENTATION↗

ADVANCED X-BAND TEST ACCELERATOR FOR HIGH BRIGHTNESS ELECTRON AND GAMMA RAY BEAMS

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

42 ENGINEERING↗

Advanced X-Band Test Accelerator for High Brightness Electron and Gamma Ray Beams

In support of Compton scattering gamma-ray source efforts at LLNL, a multi-bunch test stand is being developed to investigate accelerator optimization for future upgrades. This test stand will enable work to explore the science and technology paths required to boost the current 10 Hz monoenergetic gamma-ray (MEGa-Ray) technology to an effective repetition rate exceeding 1 kHz, potentially increasing the average gamma-ray brightness by two orders of magnitude. Multiple bunches must be of exceedingly high quality to produce narrow-bandwidth gamma-rays. Modeling efforts will be presented, along with plans for a multi-bunch test stand at LLNL. The test stand will consist of a 5.5 cell X-band rf photoinjector, single accelerator section, and beam diagnostics. The photoinjector will be a high gradient standing wave structure, featuring a dual feed racetrack coupler. The accelerator will increase the electron energy so that the emittance can be measured using quadrupole scanning techniques. Multi-bunch diagnostics will be developed so that the beam quality can be measured and compared with theory. Design will be presented with modeling simulations, and layout plans.

43 PARTICLE ACCELERATORS↗

Validation of the beam tracing method for heating and diagnostics

The beam tracing approximate description of the propagation and absorption of wave beams is studied and compared to the corresponding exact solution of the wave equation for two simplified models relevant to electron cyclotron resonance heating and reflectometry diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved chopping of a lithium beam for plasma edge diagnostic at ASDEX Upgrade

The lithium beam diagnostic at ASDEX Upgrade routinely delivers electron density profiles in the plasma edge by lithium beam impact excitation spectroscopy. An accurate background subtraction requires a periodically chopped lithium beam. A new, improved chopping system was developed and installed. It involves a voltage modulation for the extractor electrode and the beam deflection plates. The modulation of the extractor electrode reduces the unused portion of lithium ions and improves the stability of the beam with respect to its position. Furthermore, the data indicate an extended emitter lifetime. The extractor chopping was also found to be insensitive to sparks. The deflection chopping experiments demonstrated beam chopping in the kilohertz range. The significantly higher modulation frequency of the deflection chopping improves background subtraction of fast transient events. It allows a more accurate density measurements in the scrape off layer during impurity injections and edge localized modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy resolution Thomson Parabola spectrometer for laser plasma diagnostics

Thomson Parabola (TP) spectrometers are widely used devices for laser-driven beam diagnostics as they provide a complete set of information on the accelerated particles. A novel TP has been developed at LNS with a design able to detect protons up to 20 MeV. The layout design and some results obtained during the experimental campaign at PALS laboratory will be reported in the following.