Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “average atom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Monte Carlo techniques for solving transport problems

The Monte Carlo procedure is a model sampling technique. A model is established, and the behavior of sample units in this model is followed. A sufficient number of sample units are followed to obtain a statistical average or macroscopic quantities, which are the quantities of interest. This technique was used in crude form by Fermi in connection with the building of the first atomic pile. Later, Von Neumann and Ulam developed and used the Monte Carlo procedure extensively in developing the atomic bomb. Since then this technique has gained considerable use in nuclear reactor problems (refs. 1 and 2), and we at the Lewis Research Center have been extending it to thermal radiation (refs. 3 and 4), rarefied gas flows, and plasma flow problems (ref. 5). This technique, which requires a large number of sample histories to obtain solutions with small variances, is receiving greater use because of the development of the high-speed electronic computers.

SAMPLED DATA SYSTEM↗

Line-by-line transport calculations for Jupiter entry probes

Line-by-line calculations of the radiative transport for a condition near peak heating for entry of the Galileo probe into the Jovian atmosphere are described. The discussion includes a thorough specification of the atomic and molecular input data used in the calculations that could be useful to others working in the field. The results show that the use of spectrally averaged cross sections for diatomic absorbers such as CO and C2 in the boundary layer can lead to an underestimation (by as much as 29%) of the spectral flux at the stagnation point. On the other hand, for the turbulent region near the cone frustum on the probe, the flow tends to be optically thin, and the spectrally averaged results commonly used in coupled radiative transport-flow field calculations are in good agreement with the present line-by-line results. It is recommended that these results be taken into account in sizing the final thickness of the Galileo's heat shield.

Arnold, J. O.↗

Shear coaxial injector atomization phenomena for combusting and non-combusting conditions

Measurements of LOX drop size and velocity in a uni-element liquid propellant rocket chamber are presented. The use of the Phase Doppler Particle Analyzer in obtaining temporally-averaged probability density functions of drop size in a harsh rocket environment has been demonstrated. Complementary measurements of drop size/velocity for simulants under cold flow conditions are also presented. The drop size/velocity measurements made for combusting and cold flow conditions are compared, and the results indicate that there are significant differences in the two flowfields.

Pal, S.↗

Atomic data from the iron project. 3: Rate coefficients for electron impact excitation of boron-like ions: Ne VI, Mg VIII, Al IX, Si X, S XII, Ar XIV, Ca XVI and Fe XXII

Collison strengths and maxwellian averaged rate coefficients have been calculated for the 105 transitions among all 15 fine structure levels of the 8 LS terms 2s(sup 2) 2 P(P-2(sup 0 sub 1/, 3/2)), 2s2p(sup 2)(P-4(sub 1/2,3/2,5/2), D-2(sub 3/2, 5/2), S-2(sub 1/2), P-2(sub 1/2, 3/2)), 2p(sup 3)(S-4(sup 0)(sub 3/2), D-2(sup 0 sub 3/2, 5/2), P-2(sup 0 sub 1/2, 3/2)) in highly- charged B-like Ne, Mg, Al, Si, S, Ar, Ca and Fe. Rate coefficients have been tabulated at a wide range of temperatures, depending on the ion charge and abundance in plasma sources. Earlier work for O IV has also been extended to include the high temperature range. A brief discussion of the calculations, sample results, and comparison with earlier works is also given. While much of the new data should be applicable to UV spectral diagnostics, the new rates for the important ground state fine structure transition P-2(sup 0 sub 1/2)-P-2(sup 0 sub 3/2) should result in significant revision of the IR cooling rates in plasmas where B-like ions are prominent constituents, since the new rate coefficients are generally higher by several factors compared with the older data.

Zhang, Hong Lin↗

Viscosity Relaxation in Molten HgZnTe

Rotating cup measurements of the viscosity of the pseudo-binary melt, HgZnTe have shown that the isothermal liquid with zinc mole fraction 0.16 requires tens of hours of equilibration time before a steady viscous state can be achieved. Over this relaxation period, the viscosity at 790 C increases by a factor of two, while the viscosity at 810 C increases by 40%. Noting that the Group VI elements tend to polymerize when molten, we suggest that the viscosity of the melt is enhanced by the slow formation of Te atom chains. To explain the build-up of linear Te n-mers, we propose a scheme, which contains formation reactions with second order kinetics that increase the molecular weight, and decomposition reactions with first order kinetics that inactivate the chains. The resulting rate equations can be solved for the time dependence of each molecular weight fraction. Using these molecular weight fractions, we calculate the time dependence of the average molecular weight. Using the standard semi-empirical relation between polymer average molecular weight and viscosity, we then calculate the viscosity relaxation curve. By curve fitting, we find that the data imply that the rate constant for n-mer formation is much smaller than the rate constant for n-mer deactivation, suggesting that Te atoms only weakly polymerize in molten HgZnTe. The steady state toward which the melt relaxes occurs as the rate of formation of an n-mer becomes exactly balanced by the sum of the rate for its deactivation and the rate for its polymerization to form an (n+1)-mer.

Su, Ching-Hua↗

A rocket observation of the far-ultraviolet spectrum of Saturn

Far-ultraviolet (1160-1750 A) spectra of the Saturnian disk and the ring system have been obtained by using a very sensitive rocket-borne spectrograph with a microchannel plate detector. The use of two apertures of different diameter in the telescope focal plane permitted the separation of the contribution of the planetary disk from that of the rings. H I lambda 1216 was the only atomic spectral line emission detected in the planet and the rings. A weak signal from the disk between 1300 A and 1500 A was observed. Geometric disk albedos, averaged over 50 A, were determined from 1500 A to 1700 A. Measurements of the ring reflectivity longward of 1650 A are compatible with H2O frost but not NH3 frost.

Weiser, H.↗

Mass spectrometric measurements of the neutral gas composition of the thermosphere and exosphere of Venus

The neutral gas composition and density in the thermosphere of Venus is being measured with a quadrupole mass spectrometer on the Pioneer Venus orbiter. Data are obtained near periapsis once per day approximately 150-250 km above the surface. The principal gases in the thermosphere are CO2, CO, N2, O, N, and He. Atomic oxygen is the major constituent above 155 km on the dayside and also on the nightside up to 180 km when helium becomes the major constituent. The average values of CO2, CO, N2, O, and N remain nearly constant during day and night, but an abrupt change occurs across the terminator from a high dayside value to a low nightside value. The helium density varies in the opposite way, and a distinct bulge was observed at night near the morning terminator. The data have been used as the basis of an empirical model. Large orbit to orbit variations in densities were also observed on the nightside, suggesting perhaps strong turbulent motion in the atmosphere below. Kinetic temperatures inferred from scale heights are approximately 285 K on the dayside and 110 K at night. The average global temperature obtained from the model is 199 K.

Niemann, H. B.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed.

Jones, W. R.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed. Previously announced in STAR as N82-24322

Jones, W. R., Jr.↗

The interstellar abundances of tin and four other heavy elements

Spectra recorded at 1150-1600 A with an instrumental resolution near 16 km/s were obtained with the Goddard High-Resolution Spectrograph on board the HST. The gaseous interstellar abundances of five heavy elements along the light paths to 23 Ori, 15 Mon, 1 Sco, Pi Sco, and Pi Aqr were determined from the observations. The 1400.450 A line of Sn II was detected and identified toward three stars; at Z = 50, tin is the first element from the fifth row of the periodic table to be identified in the interstellar medium. One spectral line of each of Cu II (Z = 29) and Ga II (Z = 31), three lines of Ge II (Z = 32), and two lines of Kr I (Z = 36) were also detected toward some or all of the five stars. The depletions of these five heavy elements generally decrease monotonically with increasing atomic number toward each of the six stars, and tin is generally undepleted within the observational errors. The depletions of 26 elements from the interstellar gas in an average dense interstellar cloud appear to correlate with the elemental 'nebular' condensation temperatures more closely than with the first ionization potentials.

Hobbs, L. M.↗

A new transient pulsar in the Small Magellanic Cloud with an unusual x-ray spectrum

This article reports the discovery of a luminous (3.5 x 10(exp 37) ergs/sec over the 0.2 to 2 keV band) transient X-ray pulsar in the Small Magellanic Cloud (SMC) with an extremely soft component to its X-ray spectrum. This is the first time that a spectrum of this type has been seen in this class of X-ray source. The pulse period is 2.7632 s, and the pulse modulation appears to vary with energy from nearly unpulsed in the low-energy band of the ROSAT Position Sensitive Proportional Counter (PSPC) (0.07 to 0.4 keV) to about 50% in the high-energy band (1.0 to 2.4 keV). The object, RX J0059.2-7138, also shows flickering variability in its X-ray emission on timescales of 50 to 100s. The pulse-phase-averaged PSPC X-ray spectrum can be well described by a two-component source model seen through an absorbing column density of approximately 10(exp 21) atoms cm(exp -2). One spectral component is a power law with photon index 2.4. The other component is significantly softer and can be described by either a steeply falling power law or a blackbody with a temperature KT(sub BB) approximately 35 eV. Ths component is transient, but evidently upulsed, and, for the blackbody model fits, requires a large bolometric luminosity: near, or even several times greater than, the Eddington luminosity for a 1.4 solar mass object. When these characteristics of its soft emission are considered, RX J0059.2-7138 appears quite similar to other X-ray sources in the magellanic Clouds, such as CAL 83, CAL 87, and RX J0527.8-6954, which show only extreme ultrasoft (EUS) X-ray spectra. The discovery of RX J0059.2-7138, a probably high-mass X-ray binary, clearly indicates that EUS spectra may arise from accretion-powered neutron-star X-ray sources. This result lends support to the idea that some of the 'pure' EUS sources may be shrouded low-mass X-ray binaries rather than accreting white dwarfs.

Hughes, John P.↗

Ratio of Sodium to Potassium in the Mercurian Exosphere

Sodium (Na) and Potassium (K) atoms can be seen in the exosphere of Mercury and the Moon because they are extremely efficient at scattering sunlight. These species must be derived from surface materials, so that we might expect the ratio of sodium to potassium to reflect the ratio of these elements in the surface crust. This expectation is approximately born out for the Moon, where the ratio of sodium to potassium in the lunar exosphere averages to be about 6, not too far from the ratio in lunar rocks of 2 to 7. However, the ratio in the Mercury exosphere was found to be in the range 80 to 190, and at least once, as high as 400. The sodium and potassium atoms seen in the Mercury exosphere represent a balance between production from the surface and loss to space. Only if the production efficiencies and loss rates for Na and K were equal, would the ratio of Na to K in the exosphere reflect the ratio in the surface rocks. Since a value of 100 or more for the ratio of sodium to potassium in the surface rocks seems very unlikely, the high values of the observed ratios suggests that either production efficiencies or loss processes for the two elements are not equivalent. It does not seem likely that source processes should be different on the Moon and Mercury by an order of magnitude. This suggests that loss processes rather than source processes are the cause of the difference between the two. The major loss processes for sodium and potassium on Mercury are radiation pressure and trapping of photoions by the solar wind. Radiation pressure can reach 50-70% of surface gravity, and can sweep sodium and potassium atoms off the planet, provided they are sufficiently hot. Photoionization followed by trapping of the ions in the solar wind is the other major loss process. Photoions are accelerated to keV energies in the magnetosphere, and may either intercept the magnetopause, and be lost from the planet, or impact the planetary surface. Ions that impact the surface are neutralized, and are then available for resupply to the exosphere. The loss efficiency depends on characteristics of the magnetosphere that determine the fraction of the ions that are recycled by neutralization on the surface. Over the preceding decade, we have collected sodium and potassium data for Mercury at irregular intervals. We analyzed these data to extract values for the Na/K ratio at a variety of conditions on Mercury. Additional information is contained in the original extended abstract.

Potter, A. E.↗

Atomic Oxygen Abundance in Molecular Clouds: Absorption Toward Sagittarius B2

We have obtained high-resolution (approximately 35 km/s) spectra toward the molecular cloud Sgr B2 at 63 micrometers, the wavelength of the ground-state fine-structure line of atomic oxygen (O(I)), using the ISO-LWS instrument. Four separate velocity components are seen in the deconvolved spectrum, in absorption against the dust continuum emission of Sgr B2. Three of these components, corresponding to foreground clouds, are used to study the O(I) content of the cool molecular gas along the line of sight. In principle, the atomic oxygen that produces a particular velocity component could exist in any, or all, of three physically distinct regions: inside a dense molecular cloud, in the UV illuminated surface layer (PDR) of a cloud, and in an atomic (H(I)) gas halo. For each of the three foreground clouds, we estimate, and subtract from the observed O(I) column density, the oxygen content of the H(I) halo gas, by scaling from a published high-resolution 21 cm spectrum. We find that the remaining O(I) column density is correlated with the observed (13)CO column density. From the slope of this correlation, an average [O(I)]/[(13)CO] ratio of 270 +/- 120 (3-sigma) is derived, which corresponds to [O(I)]/[(13)CO] = 9 for a CO to (13)CO abundance ratio of 30. Assuming a (13)CO abundance of 1x10(exp -6) with respect to H nuclei, we derive an atomic oxygen abundance of 2.7x10(exp -4) in the dense gas phase, corresponding to a 15% oxygen depletion compared to the diffuse ISM in our Galactic neighborhood. The presence of multiple, spectrally resolved velocity components in the Sgr B2 absorption spectrum allows, for the first time, a direct determination of the PDR contribution to the O(I) column density. The PDR regions should contain O(I) but not (13)CO, and would thus be expected to produce an offset in the O(I)-(13)CO correlation. Our data do not show such an offset, suggesting that within our beam O(I) is spatially coexistent with the molecular gas, as traced by (13)CO. This may be a result of the inhomogeneous nature of the clouds.

Lis, D. C.↗

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John↗

Distribution and evolution of Zn, Cd, and Pb in Apollo 16 regolith samples and the average U-Pb ages of the parent rocks

The concentration of surface (low temperature site) and interior (high temperature site) Cd, Zn, and Pb in 13 Apollo 16 highland fines samples, pristine rock 65325, and mare fines sample 75081 were analyzed directly from the thermal release profiles obtained by flameless atomic absorption technique (FLAA). Cd and Zn in pristine ferroan anothosite 65325, anorthositic grains of the most mature fines 65701, and basaltic rock fragments of mare fines 75081 were almost all surface Cd and Zn indicating that most volatiles were deposited on the surfaces of vugs, vesicles and microcracks during the initial cooling process. A considerable amount of interior Cd and Zn was observed in agglutinates. This result suggests that high temperature site interior volatiles originate from entrapment during the lunar maturation processes. Interior Cd found in the most mature fines sample 65701 was only about 15% of the total Cd in the sample. Interior Pb present in Apollo 16 fines samples went up to 60%. From our Cd studies we can assume that this interior Pb in highland fines samples is largely due to the radiogenic decay which occurred after the redistribution of the volatiles took place. We obtained an average age of 4.0 b.y. for the parent rocks of Apollo 16 highland regolith from our interior Pb analyses.

Cirlin, E. H.↗

An angular momentum approximation for molecular collisions in the presence of intense laser radiation

An approximation to a previously presented rigorous description of molecular (atom-atom) collisions occurring in the presence of intense radiation is investigated. This rigorous description explicitly considers the angular momentum transferred between the molecule and the radiation field in the absorption or emission of a photon, but involves a complicated system of close-coupled equations which must be solved independently for each projection M of the initial, total molecular angular momentum. (This is a direct consequence of the lack of rotational invariance in the molecule-field problem). These equations are solved for a model system which mimics the collision of a halogen with a rare gas atom. Empirical observations made in the course of performing these calculations lead to the development of an approximation which avoids the repeated calculations for each initial M. This orientational average approximation greatly reduces the effort required to describe the system, and for the model calculation, yields accurate results for field intensities as high as 10 GW/sq cm.

Devries, P. L.↗

The interstellar medium on the Gamma Cassiopeiae line of sight

The interstellar medium on the Gamma Cas line of sight is studied through the observations of O I, H2, H I, D I, and Ar I absorption features with the Copernicus satellite. By using the velocity structure of the line of sight previously determined through atomic nitrogen, it is demonstrated that these neutrals are located in the same physical regions and that the O I and Ar I abundances could be solar, on the average, relative to N I in all components. The 1066.660 A Ar I line profile is contaminated by an unidentified line, already detected in the spectrum of Zeta Pup. Furthermore, a peculiar behavior of the Ar I abundance in the different components is reported, possibly associated with high-velocity interstellar gas present on the line of sight. It is concluded that the Gamma Cas line of sight could intercept a dense cloud which has been engulfed and disrupted by a shock.

Ferlet, R.↗

Flame Structure Comparison using Jet-A and an isoparaffinic fuel in a lean direct injection flame tube combustor

This paper offers a first look at some recently acquired optical data. The effect of reference velocity on flame thickness, fuel atomization, and relative speciation of OH, CH, C2, and soot for two National Jet Fuel Combustion Program (NJFCP) fuels are explored in this paper. The NJFCP fuels are an average Jet-A, designated A-2 with a derived cetane number (DCN) of 49, and an isoparaffinic kerosene, C-4. C-4 fuel is made up primarily of C9 - C13, and C16 isoparaffins and is a combination of 60% Sasol IPK and 40% GEVO alcohol-to-jet (ATJ). C-4 has a DCN of 28. Both fuels begin distillation at about the same temperature, but C-4 completes about 30 degrees Celsius lower than A-2. Chemiluminescence images were acquired in a 5-atm gas turbine flame tube combustor using the NASA 7-point lean direct injector (LDI). The flame characteristics were determined through imaging with three scientific cameras. OH*, CH*, and C2* chemiluminescence were collected through narrow bandpass filters centered at 313nm, 430nm and 515nm onto an intensified high-speed camera framed at 8-kHz. A second high-speed camera collected color flame images at rates between 40 and 50 kHz. An ICCD camera framed at 20 Hz was used to record planar laser scatter from liquid fuel. Differences in speciation for the chemiluminescent species was observed between the two fuels. Some reasons for the differences are explored in this paper.

gas turbine combustion↗