Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “active twist”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

222 records · Page 13

Tectonics of the Outer Planet Satellites

Tectonic features on the satellites of the outer planets range from the familiar, such as clearly recognizable graben on many satellites, to the bizarre, such as the ubiquitous double ridges on Europa, the twisting sets of ridges on Triton, or the isolated giant mountains rising from Io's surface. All of the large and middle-sized outer planet satellites except Io are dominated by water ice near their surfaces. Though ice is a brittle material at the cold temperatures found in the outer solar system, the amount of energy it takes to bring it close to its melting point is lower than for a rocky body. Therefore, some unique features of icy satellite tectonics may be influenced by a near-surface ductile layer beneath the brittle surface material, and several of the icy satellites may possess subsurface oceans. Sources of stress to drive tectonism are commonly dominated by the tides that deform these satellites as they orbit their primary giant planets. On several satellites, the observed tectonic features may be the result of changes in their tidal figures, or motions of their solid surfaces with respect to their tidal figures. Other driving mechanisms for tectonics include volume changes due to ice or water phase changes in the interior, thermoelastic stress, deformation of the surface above rising diapirs of warm ice, and motion of subsurface material toward large impact basins as they fill in and relax. Most satellites exhibit evidence for extensional deformation, and some exhibit strike-slip faulting, whereas contractional tectonism appears to be rare. Io s surface is unique, exhibiting huge isolated mountains that may be blocks of crust tilting and foundering into the rapidly emptying interior as the surface is constantly buried by deposits from hyperactive volcanoes. Of the satellites, diminutive Enceladus is spectacularly active; its south polar terrain is a site of young tectonism, copious heat flow, and tall plumes venting into space. Europa's surface is pervasively tectonized, covered with a diverse array of exotic and incompletely understood tectonic features. The paucity of impact craters on Europa suggests that its tectonic activity is ongoing. Geysers on Triton show that some degree of current activity, while tectonic features that cross sparsely cratered terrain indicate that it may also be tectonically active. Ganymede and Miranda both exhibit ancient terrains that have been pulled apart by normal faulting. On Ganymede these faults form a global network, while they are confined to regional provinces on Miranda. Ariel, Dione, Tethys, Rhea, and Titania all have systems of normal faults cutting across their surfaces, though the rifting is less pronounced than it is on Ganymede and Miranda. Iapetus exhibits a giant equatorial ridge that has defied simple explanation. The rest of the large and middle-sized satellites show very little evidence for tectonic features on their surfaces, though the exploration of Titan's surface has just begun.

McKinnon, W. B.↗

3D-Stereoscopic Analysis of Solar Active Region Loops: SoHo/EIT Observations at Temperatures of 1.5-2.5 MK - 2

In this paper we study the three-dimensional (3D) structure of hot (T(sub e) approximately equals 1.5 - 2.5 MK) loops in solar active region NOAA 7986, observed on 1996 August 30 with the Extreme-ultraviolet Imaging Telescope (EIT) onboard the Solar and Heliospheric Observatory (SoHO). This complements a first study on cooler (T(sub e) approximately equals 1.0 - 1.5 MK) loops of the same active region, using the same method of Dynamic Stereoscopy to reconstruct the 3D geometry. We reconstruct the 3D-coordinates x(s), y(s), z(s), the density n(sub e)(s), and temperature profile T(sub e)(s) of 35 individual loop segments (as function of the loop coordinate s) using EIT 195 A and 284 A images. The major findings are: (1) All loops are found to be in hydrostatic equilibrium, in the entire temperature regime of T(sub e) = 1.0 - 2.5 MK; (2) The analyzed loops have a height of 2-3 scale heights, and thus only segments extending over about one vertical scale height have sufficient emission measure contrast for detection; (3) The temperature gradient over the lowest scale height is of order dT/ds is approximately 1 - 4 K/km; (4) The radiative loss rate is found to exceed the conductive loss rate by about two orders or magnitude, making thermal conduction negligible to explain the temperature structure of the loops; (5) A steady-state can only be achieved when the heating rate E(sub H) matches the radiative loss rate in hydrostatic equilibrium, requiring a heat deposition length lambda(sub H) of the half density scale height lambda, predicting a scaling law with the loop base pressure, EH varies as p(sub 0 exp 2). This favors coronal heating mechanisms that operate near the loop footpoints; (6) We find a reciprocal correlation between the loop pressure p(sub 0) and loop length L, i.e. p(sub 0) varies as 1/L, implying a scaling law of the steady-state requirement with loop length, i.e. E(sub H ) varies as 1/L(exp 2). The heating rate shows no correlation with the loop-aligned magnetic field component B(sub z) at the footpoints, but is correlated with the azimuthal field B(sub phi) = Bz(RDelta Phi/L) of a twisted loop, and is thus consistent with heating mechanisms based on field-aligned currents.

Aschwanden, Markus J.↗

Ames Optimized TCA Configuration

Configuration design at Ames was carried out with the SYN87-SB (single block) Euler code using a 193 x 49 x 65 C-H grid. The Euler solver is coupled to the constrained (NPSOL) and the unconstrained (QNMDIF) optimization packages. Since the single block grid is able to model only wing-body configurations, the nacelle/diverter effects were included in the optimization process by SYN87's option to superimpose the nacelle/diverter interference pressures on the wing. These interference pressures were calculated using the AIRPLANE code. AIRPLANE is an Euler solver that uses a unstructured tetrahedral mesh and is capable of computations about arbitrary complete configurations. In addition, the buoyancy effects of the nacelle/diverters were also included in the design process by imposing the pressure field obtained during the design process onto the triangulated surfaces of the nacelle/diverter mesh generated by AIRPLANE. The interference pressures and nacelle buoyancy effects are added to the final forces after each flow field calculation. Full details of the (recently enhanced) ghost nacelle capability are given in a related talk. The pseudo nacelle corrections were greatly improved during this design cycle. During the Ref H and Cycle 1 design activities, the nacelles were only translated and pitched. In the cycle 2 design effort the nacelles can translate vertically, and pitch to accommodate the changes in the lower surface geometry. The diverter heights (between their leading and trailing edges) were modified during design as the shape of the lower wing changed, with the drag of the diverter changing accordingly. Both adjoint and finite difference gradients were used during optimization. The adjoint-based gradients were found to give good direction in the design space for configurations near the starting point, but as the design approached a minimum, the finite difference gradients were found to be more accurate. Use of finite difference gradients was limited by the CPU time limit available on the Cray machines. A typical optimization run using finite difference gradients can use only 30 to 40 design variables and one optimization iteration within the 8 hour queue limit for the chosen grid size and convergence level. The efficiency afforded by the adjoint method allowed for 50-120 design variables and 5-10 optimization iterations in the 8 hour queue. Geometric perturbations to the wing and fuselage were made using the Hicks/Henne (HH) shape functions. The HH functions were distributed uniformly along the chords of the wing defining sections and lofted linearly. During single-surface design, constraints on thickness and volume at selected wing stations were imposed. Both fuselage camber and cross-sectional area distributions were permitted to change during design. The major disadvantage to the use of these functions is the inherent surface waviness produced by repeated use of such functions. Many smoothing operations were required following optimization runs to produce a configuration with reasonable smoothness. Wagner functions were also used on the wing sections but were never used on the fuselage. The Wagner functions are a family of increasingly oscillatory functions that have also been used extensively in airfoil design. The leading and trailing edge regions of the wing were designed by use of polynomial and monomial functions respectively. Twist was attempted but was abandoned because of little performance improvement available from changing the baseline twist.

Cliff, Susan E.↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗