Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberration correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On the Localized Nature of the Structural Transformations of Li2MnO 3 Following Electrochemical Cycling

Although the Li-excess layered-oxide Li2MnO3 has a high theoretical capacity, structural transformations within the oxide during electrochemical cycling lead to relatively low experimental capacities, hindering its use in practical applications. Here, aberration-corrected scanning transmission electron microscopy/electron energy loss spectroscopy and high-resolution X-ray diffraction are used to characterize the oxide following electrochemical cycling. Microscopy reveals the coexistence of regions with local monoclinic, spinel, and rock-salt symmetries, indicating localized and inhomogeneous structural evolutions. Crystal structure transformations are observed both at the particle surface and in the bulk. At the surface, these transformed regions resemble spinel Mn3O4 or rock-salt MnO, consistent with oxygen loss. In the bulk, the regions resemble defect spinels, such as the layered-spinel LixMn4/3O4, which suggest a partial phase transformation consistent with oxygen retention. Both microscopy and diffraction data of the cycled sample indicate areas of pristine Li2MnO3; the presence of such areas, in close proximity to LixMn4/3O4 areas, suggests that the layered to spinel structure transformation is partially reversible. Spinel, disordered rock salt, and pristine areas are also observed in Li2MnO3 samples intentionally damaged by electron beam irradiation. This observation indicates that the dynamic processes resulting in phase transformations can be studied for a variety of oxide systems by a judicious selection of irradiation conditions.

aberration-corrected scanning transmission electro↗

Controlling electron beam-induced structure modifications and cation exchange in cadmium sulfide–copper sulfide heterostructured nanorods

The atomic structure and interfaces of CdS/Cu 2 S heterostructured nanorods are explored with the aberration-corrected TEAM 0.5 electron microscope operated at 80 kV and 300 kV applying in-line holography and complementary techniques. Cu 2 S exhibits a low-chalcocite structure in pristine CdS/Cu 2 S nanorods. Under electron beam irradiation the Cu 2 S phase transforms into a high-chalcocite phase while the CdS phase maintains its wurtzite structure. Time-resolved experiments reveal that Cu + -Cd 2+ cation exchange at the CdS/Cu 2 S interfaces is stimulated by the electron beam and proceeds within an undisturbed and coherent sulfur sub-lattice. A variation of the electron beam current provides an efficient way to control and exploit such irreversible solid-state chemical processes that provide unique information about system dynamics at the atomic scale. Particularly, we show that the electron beam-induced copper-cadmium exchange is site specific and anisotropic. A resulting displacement of the CdS/Cu 2 S interfaces caused by beam-induced cation interdiffusion equals within a factor of 3-10 previously reported Cu diffusion length measurements in heterostructured CdS/Cu 2 S thin film solar cells with an activation energy of 0.96 eV.

36 MATERIALS SCIENCE↗

Surface-structure sensitivity of CeO 2 nanocrystals in photocatalysis and enhancing the reactivity with nanogold

Structure–function correlations are a central theme in heterogeneous (photo)catalysis. In this research, using aberration-corrected scanning transmission electron microscopy (STEM), the atomic surface structures of well-defined one-dimensional (1D) CeO 2 nanorods (NRs) and 3D nanocubes (NCs) are directly visualized at subangstrom resolution. CeO 2 NCs predominantly expose the {100} facet, with {110} and {111} as minor cutoff facets at the respective edges and corners. Notably, the outermost surface layer of the {100} facet is nearly O-terminated. Neither surface relaxations nor reconstructions on {100} are observed, indicating unusual polarity compensation, which is primarily mediated by near-surface oxygen vacancies. The surface of CeO 2 NRs is highly stepped, with the enclosed {110} facet exposing Ce cations and O anions on terraces. On the basis of STEM profile-view imaging and electronic structure analysis, the photoreactivity of CeO2 nanocrystals toward aqueous methyl orange degradation under UV is revealed to be surface-structure-sensitive, following the order: {110} >> {100}. The underlying surface-structure sensitivity can be attributed to the variation in low-coordinate surface cerium cations between {110} and {100} facets. To further enhance light absorption, Au nanoparticles (NPs) are deposited on CeO 2 NRs to form Au/CeO 2 plasmonic nanocomposites, which dramatically promotes the photoreactivity that is Au particle size- and excitation light wavelength-dependent. The mechanisms responsible for the enhancement of photocatalytic activity are discussed, highlighting the crucial role of photoexcited charge carrier transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Origins of Ferroelastic Domain Wall Mobility in Ferroelectric Multilayers

Here we investigate the nanoscale origins of ferroelastic domain wall motion in ferroelectric multilayer thin films that lead to giant electromechanical responses. We present direct evidence for complex underpinning factors that result in ferroelastic domain wall mobility using a combination of atomic-level aberration corrected scanning transmission electron microscopy and phase-field simulations in model epitaxial (001) tetragonal (T) PbZr x Ti 1-x O 3 (PZT)/rhombohedral (R) PbZr x Ti 1-x O 3 (PZT) bilayer heterostructures. The local electric dipole distribution is imaged on an atomic scale for a ferroelastic domain wall that nucleates in the R-layer and cuts through the composition breaking the T/R interface. Our studies reveal a highly complex polarization rotation domain structure that is nearly on the knife-edge at the vicinity of this wall. Induced phases, namely tetragonal-like and rhombohedral-like monoclinic were observed close to the interface, and exotic domain arrangements, such as a half-four-fold closure structure, are observed. Phase field simulations show this is due to the minimization of the excessive elastic and electrostatic energies driven by the enormous strain gradient present at the location of the ferroelastic domain walls. Thus, in response to an applied stimulus, such as an electric field, any polarization reorientation must minimize the elastic and electrostatic discontinuities due to this strain gradient, which would induce a dramatic rearrangement of the domain structure. This insight into the origins of ferroelastic domain wall motion will allow researchers to better “craft” such multilayered ferroelectric systems with precisely tailored domain wall functionality and enhanced sensitivity, which can be exploited for the next generation of integrated piezoelectric technologies.

36 MATERIALS SCIENCE↗

Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects (Final Technical Report)

This is the final technical report for DOE Award DE-SC0005132 entitled “Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects.” This award originated on August 15, 2010 with Principle Investigator Prof. Phil Batson of Rutgers, The State University of New Jersey. Prof. Batson transitioned to Professor Emeritus status on January 31, 2023. At that time PI status was transferred to Prof. Robert Bartynski of the Department of Physics and Astronomy at Rutgers, The State University of New Jersey, and Director of the Rutgers Laboratory for Surface Modification. The central theme of the research performed under this award is develop and refine a NION aberration-corrected Scanning Transmission Electron Microscope to attain atomic spatial resolution and sub 10meV energy resolution in electron energy loss spectroscopy (EELS) performed on the transmitted electron beam. These capabilities allow examination of the excitation properties (primarily plasmonic and vibrational [ie., phonons] of nanoscale objects when excited with a highly-localized (~ Angstrom-scale) high energy (~ 60 keV) electron beam. Direct excitations (i.e., the response to electrons impinging directly on the sample) as well as excitations in response to the dynamic electric (and magnetic!) fields of an aloof electron beam (i.e., a beam that is close to but displaced from the target) have been studied. Our experimental work has benefited greatly from close collaborations with theoretical colleagues, but at Rutgers and from around the world, providing a much more complete understanding of the observed phenomena and suggesting avenues for further study and practical applications. This report summarizes the technical and scientific achievements accomplished during the entire award period. More extensive details are available in the Progress Reports that have already been filed with the Department of Energy. The report is divided into six sections. The first four sections focus on exploring, developing and understanding several unique capabilities and phenomena discovered and accessible owing to the high spatial- and energy-resolution we have been able to achieve. The latter two sections focus on applications of the STEM’s novel capabilities to study atomic- and nanometer-scale properties of solids, as well as broader applications to advanced and bio-materials.

47 OTHER INSTRUMENTATION↗

Automatic software correction of residual aberrations in reconstructed HRTEM exit waves of crystalline samples

Abstract We develop an automatic and objective method to measure and correct residual aberrations in atomic-resolution HRTEM complex exit waves for crystalline samples aligned along a low-index zone axis. Our method uses the approximate rotational point symmetry of a column of atoms or single atom to iteratively calculate a best-fit numerical phase plate for this symmetry condition, and does not require information about the sample thickness or precise structure. We apply our method to two experimental focal series reconstructions, imaging a β-Si 3 N 4 wedge with O and N doping, and a single-layer graphene grain boundary. We use peak and lattice fitting to evaluate the precision of the corrected exit waves. We also apply our method to the exit wave of a Si wedge retrieved by off-axis electron holography. In all cases, the software correction of the residual aberration function improves the accuracy of the measured exit waves.

36 MATERIALS SCIENCE↗

Live imaging using adaptive optics with fluorescent protein guide-stars

Spatially and temporally dependent optical aberrations induced by the inhomogeneous refractive index of live samples limit the resolution of live dynamic imaging. We introduce an adaptive optical microscope with a direct wavefront sensing method using a Shack-Hartmann wavefront sensor and fluorescent protein guide-stars for live imaging. The results of imaging Drosophila embryos demonstrate its ability to correct aberrations and achieve near diffraction limited images of medial sections of large Drosophila embryos. GFP-polo labeled centrosomes can be observed clearly after correction but cannot be observed before correction. Four dimensional time lapse images are achieved with the correction of dynamic aberrations. These studies also demonstrate that the GFP-tagged centrosome proteins, Polo and Cnn, serve as excellent biological guide-stars for adaptive optics based microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Spherical Aberrations - Final Focus and Solenoid Scans

Conclusions: Spherical aberrations in solenoids are unavoidable and problematic whenever the beam is focused; It may be possible to include a spherical aberration correction to the analysis of a solenoid scan in the manner described above although more accurate 2D PIC models should be studied to determine the accuracy of the very simple model used above. This correction would have to be iterated as the beam size in the solenoid is iterated; A quadrupole triplet final focus would not have aberrations (preliminary analysis shows improvement in spot size, very difficult to tune).

43 PARTICLE ACCELERATORS↗

The Electron Ronchigram

The electron Ronchigram is a form of inline hologram that offers a convenient way to directly see and measure electron optical aberrations. Any user of an aberration-corrected STEM is likely to benefit from a basic understanding of how such an image is formed and used. This chapter will review the formation of the electron Ronchigram with a particular emphasis on the effects and measurement of aberrations. This review will be largely based on our own approach and previously published work.

47 OTHER INSTRUMENTATION↗

Spatial Prediction Filtering for Medical Ultrasound in Aberration and Random Noise

While medical ultrasound imaging has become one of the most widely used imaging modalities in clinics, it often suffers from suboptimal image quality especially in technically difficult patients with a large amount of fat content that induces severe phase aberration effects and decreases the signal-to-noise (SNR) ratio. Several researchers have proposed various techniques, which can be broadly categorized as either a phase aberration correction (PAC) technique or a coherence-based imaging technique, to address the challenges in imaging technically difficult patients. Although both families of techniques have shown some success in improving the image quality in the presence of a mild level of phase aberration and/or random noise, they often fail to achieve meaningful improvements in the image quality and in some cases, and even create severe image artifacts. In this work, we employ an adaptive filtering technique called frequency-space (F-X) prediction filtering, which we recently introduced in ultrasound imaging, to overcome the weaknesses of existing techniques and achieve image quality improvements more effectively under varying levels of phase aberration and random noise. Using simulated and experimental phantom data with varying levels of phase aberration and random noise, we evaluate and compare the performance of FXPF with the most representative technique for each category: NNCC-based PAC and the generalized coherence factor (GCF). Our simulation, experimental phantom, and in vivo results demonstrate that FXPF is highly robust in varying levels of phase aberration and noise, and always outperforms both NNCC-based PAC and GCF in terms of the contrast-to-noise ratio (CNR) and the contrast when both random noise and phase aberration are present.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-spectroscopic composition measurements of SrTiO 3 -La 0.7 Sr 0.3 MnO 3 multilayers using scanning convergent beam electron diffraction

The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns to a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.

74 ATOMIC AND MOLECULAR PHYSICS↗

White-Light Phase-Conjugate Mirrors as Distortion Correctors

White-light phase-conjugate mirrors would be incorporated into some optical systems, according to a proposal, as means of correcting for wavefront distortions caused by imperfections in large optical components. The proposal was given impetus by a recent demonstration that white, incoherent light can be made to undergo phase conjugation, whereas previously, only coherent light was known to undergo phase conjugation. This proposal, which is potentially applicable to almost any optical system, was motivated by a need to correct optical aberrations of the primary mirror of the Hubble Space telescope. It is difficult to fabricate large optical components like the Hubble primary mirror and to ensure the high precision typically required of such components. In most cases, despite best efforts, the components as fabricated have small imperfections that introduce optical aberrations that adversely affect imaging quality. Correcting for such aberrations is difficult and costly. The proposed use of white-light phase conjugate mirrors offers a relatively simple and inexpensive solution of the aberration-correction problem. Indeed, it should be possible to simplify the entire approach to making large optical components because there would be no need to fabricate those components with extremely high precision in the first place: A white-light phase-conjugate mirror could correct for all the distortions and aberrations in an optical system. The use of white-light phase-conjugate mirrors would be essential for ensuring high performance in optical systems containing lightweight membrane mirrors, which are highly deformable. As used here, "phase-conjugate mirror" signifies, more specifically, an optical component in which incident light undergoes time-reversal phase conjugation. In practice, a phase-conjugate mirror would typically be implemented by use of a suitably positioned and oriented photorefractive crystal. In the case of a telescope comprising a primary and secondary mirror (see figure) white light from a distant source would not be brought to initial focus on one or more imaging scientific instrument(s) as in customary practice. Instead, the light would be brought to initial focus on a phase-conjugate mirror. The phase-conjugate mirror would send a phase-conjugate image back, along the path of the incoming light, to the primary mirror. A transparent, highly efficient diffractive thin film deposited on the primary mirror would direct the phase-conjugate image to the imaging instrument(s).

Frazier, Donald↗

Optical Design for CETUS a Wide-Field 1.5-m Aperture UV Payload Being Studied for a NASA Probe Class Mission Study

As part of a study funded by NASA headquarters, we are developing a probe-class mission concept called the Cosmic Evolution through UV Spectroscopy (CETUS). CETUS includes a 1.5-m aperture diameter telescope with a large field of view (FOV). CETUS includes three scientific instruments: a far ultraviolet (FUV) and near ultraviolet (NUV) imaging camera (CAM); a NUV multiobject spectrograph (MOS); and a dual-channel point/slit spectrograph (PSS) in the Lyman ultraviolet (LUV), FUV, and NUV spectral regions. The large FOV three-mirror anastigmatic (TMA) optical telescope assembly (OTA) simultaneously feeds the three separate scientific instruments. That is, the instruments view separate portions of the TMA image plane, enabling parallel operation by the three instruments. The field viewed by the MOS, whose design is based on an Offner-type spectrographic configuration to provide wide FOV correction, is actively configured to select and isolate numerous field sources using a next-generation micro-shutter array. The two-channel CAM design is also based on an Offner-like configuration. The PSS performs high spectral resolution spectroscopy on unresolved objects over the NUV region with spectral resolving power, R ~ 40,000, in an echelle mode. The PSS also performs long-slit imaging spectroscopy at R ~ 20,000 in the LUV and FUV spectral regions with two aberration-corrected, blazed, holographic gratings used in a Rowland-like configuration. The optical system also includes two fine guidance sensors, and wavefront sensors that sample numerous locations over the full OTA FOV. In-flight wavelength calibration is performed by a wavelength calibration system, and flat-fielding is also performed, both using in-flight calibration sources. We describe the current optical design of CETUS and the major trade studies leading to the design.

space sensors↗

A transmission hologram for slitless spectrophotometry on a convergent telescope beam. 1. Focus and resolution

We report in this paper the test of a plane holographic optical element to be used as an aberration-corrected grating for a slitless spectrograph, inserted in a convergent telescope beam. Our long-term objective is the optimization of a specific hologram to switch the auxiliary telescope imager of the Vera Rubin Observatory into an accurate slitless spectrograph, dedicated to the atmospheric transmission measurement. We present and discuss here the promising results of tests performed with prototype holograms at the CTIO $0.9\,$m telescope during a run of 17 nights in 2017 May–June. After their on-sky geometrical characterization, the performances of the holograms as aberration-balanced dispersive optical elements have been established by analysing spectra obtained from spectrophotometric standard stars and narrow-band emitter planetary nebulae. Thanks to their additional optical function, our holographic disperser prototypes allow us to produce significantly better focused spectra within the full visible wavelength domain $[370,1050]\,$nm than a regular grating, which suffers from strong defocusing and aberrations when used in similar conditions. We show that the resolution of our slitless on-axis spectrograph equipped with the hologram approaches its theoretical performance. While estimating the benefits of a hologram for the spectrum resolution, the roadmap to produce a competitive holographic element for the Vera Rubin Observatory auxiliary telescope has been established.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

van der Waals Semiconductor Empowered Vertical Color Sensor

We report biomimetic artificial vision is receiving significant attention nowadays, particularly for the development of neuromorphic electronic devices, artificial intelligence, and microrobotics. Nevertheless, color recognition, the most critical vision function, is missed in the current research due to the difficulty of downscaling of the prevailing color sensing devices. Conventional color sensors typically adopt a lateral color sensing channel layout and consume a large amount of physical space, whereas compact designs suffer from an unsatisfactory color detection accuracy. In this work, we report a van der Waals semiconductor-empowered vertical color sensing structure with the emphasis on compact device profile and precise color recognition capability. More attractive, we endow color sensor hardware with the function of chromatic aberration correction, which can simplify the design of an optical lens system and, in turn, further downscales the artificial vision systems. Also, the dimension of a multiple pixel prototype device in our study confirms the scalability and practical potentials of our developed device architecture toward the above applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗