At least 235 records · Page 13

Wavelength scaling and multicolor operation of a plasma-driven attosecond x-ray source via harmonic generation

The generation of high-power coherent soft x-ray pulses of sub-100 as duration and 10 nm wavelength using beams from a GeV energy plasma wakefield accelerator has been recently investigated in Emma []. As a future upgrade to this concept, this contribution investigates scaling to shorter x-ray wavelengths by cascading undulators tuned to higher harmonics of the fundamental. We present two simulation studies for plasma-driven attosecond harmonic generation schemes with final photon wavelengths of 2 and 0.40 nm. We demonstrate in these schemes that using undulators with retuned fundamental frequencies can produce GW-scale pulses of sub-nm radiation with tens of attosecond-scale pulse lengths, an order of magnitude shorter than current state-of-the-art attosecond x-ray free electron lasers (XFELs). This multipulse multicolor operation will be broadly applicable to attosecond pump-probe experiments. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Numerical investigation of nonequilibrium electron effects on the collisional ionization rate in the collisional-radiative model

In this study, the interplay of kinetic electron physics and atomic processes in ultrashort laser-plasma interactions provides a comprehensive understanding of the impact of the electron energy distribution on plasma properties. Notably, nonequilibrium electrons play a vital role in collisional ionization, influencing ionization degrees and spectra. This paper introduces a computational model that integrates the physics of kinetic electrons and atomic processes, utilizing a Boltzmann equation for nonequilibrium electrons and a collisional-radiative model for atomic state populations. The model is used to investigate the influence of nonequilibrium electrons on collisional ionization rates and its effect on the population distribution, as observed in a widely known experiment. The study reveals a significant nonequilibrium electron presence during XFEL-matter interactions, profoundly affecting collisional ionization rates in the gas plasma, thereby necessitating careful consideration of the Collisional-Radiative model applied to such systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonance-Enhanced Multiphoton Ionization in the X-Ray Regime

In this work, we report on the nonlinear ionization of argon atoms in the short wavelength regime using ultraintense x rays from the European XFEL. After sequential multiphoton ionization, high charge states are obtained. For photon energies that are insufficient to directly ionize a 1s electron, a different mechanism is required to obtain ionization to Ar 17+ . We propose this occurs through a two-color process where the second harmonic of the FEL pulse resonantly excites the system via a 1s→2p transition followed by ionization by the fundamental FEL pulse, which is a type of x-ray resonance-enhanced multiphoton ionization (REMPI). This resonant phenomenon occurs not only for Ar 16+ , but also through lower charge states, where multiple ionization competes with decay lifetimes, making x-ray REMPI distinctive from conventional REMPI. With the aid of state-of-the-art theoretical calculations, we explain the effects of x-ray REMPI on the relevant ion yields and spectral profile.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectrotemporal Shaping of Attosecond X-Ray Pulses with a Fresh-Slice Free-Electron Laser

We propose a scheme allowing coherent shaping, i.e., controlling both the amplitude and phase, of attosecond x-ray pulses at free-electron lasers. Here, we show that by seeding an FEL with a short coherent seed that overfills the amplification bandwidth, one can shape the Wigner function of the pulse by controlling the undulator taper profile. The examples of controllable pulse pairs and trains, as well as isolated spectrotemporally shaped pulses with very broad bandwidths are examined in detail. Existing attosecond XFELs can achieve these experimental conditions in a two-stage cascade, in which the seed is generated by a short current spike in an electron bunch and shaped in an unspoiled region within the same bunch. We experimentally demonstrate the production and control of phase-stable pulse trains using this method at the Linac Coherent Light Source II.

47 OTHER INSTRUMENTATION↗

Investigation of the damping wiggler effect and application on the PAL fourth-generation storage ring

An investigation of the damping wiggler effect to reduce the emittance in the Pohang Accelerator Laboratory (PAL), a fourth-generation storage ring (4GSR) that uses a multi-bend achromat, is presented. Furthermore, a 4GSR lattice which has reduced emittance and increased dynamic aperture to amplify the synergy with two existing light sources (PLS-II and PAL-XFEL) at PAL is described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION↗

Comparing serial X-ray crystallography and microcrystal electron diffraction (MicroED) as methods for routine structure determination from small macromolecular crystals

Innovative new crystallographic methods are facilitating structural studies from ever smaller crystals of biological macromolecules. In particular, serial X-ray crystallography and microcrystal electron diffraction (MicroED) have emerged as useful methods for obtaining structural information from crystals on the nanometre to micrometre scale. Despite the utility of these methods, their implementation can often be difficult, as they present many challenges that are not encountered in traditional macromolecular crystallography experiments. Here, XFEL serial crystallography experiments and MicroED experiments using batch-grown microcrystals of the enzyme cyclophilin A are described. The results provide a roadmap for researchers hoping to design macromolecular microcrystallography experiments, and they highlight the strengths and weaknesses of the two methods. Specifically, we focus on how the different physical conditions imposed by the sample-preparation and delivery methods required for each type of experiment affect the crystal structure of the enzyme.

36 MATERIALS SCIENCE↗

Observation of substrate diffusion and ligand binding in enzyme crystals using high-repetition-rate mix-and-inject serial crystallography

Here, we illustrate what happens inside the catalytic cleft of an enzyme when substrate or ligand binds on single-millisecond timescales. The initial phase of the enzymatic cycle is observed with near-atomic resolution using the most advanced X-ray source currently available: the European XFEL (EuXFEL). The high repetition rate of the EuXFEL combined with our mix-and-inject technology enables the initial phase of ceftriaxone binding to the Mycobacterium tuberculosis β-lactamase to be followed using time-resolved crystallography in real time. It is shown how a diffusion coefficient in enzyme crystals can be derived directly from the X-ray data, enabling the determination of ligand and enzyme–ligand concentrations at any position in the crystal volume as a function of time. In addition, the structure of the irreversible inhibitor sulbactam bound to the enzyme at a 66 ms time delay after mixing is described. This demonstrates that the EuXFEL can be used as an important tool for biomedically relevant research.

36 MATERIALS SCIENCE↗

Robust error calibration for serial crystallography

Serial crystallography is an important technique with unique abilities to resolve enzymatic transition states, minimize radiation damage to sensitive metalloenzymes and perform de novo structure determination from micrometre-sized crystals. This technique requires the merging of data from thousands of crystals, making manual identification of errant crystals unfeasible. cctbx.xfel.merge uses filtering to remove problematic data. However, this process is imperfect, and data reduction must be robust to outliers. We add robustness to cctbx.xfel.merge at the step of uncertainty determination for reflection intensities. This step is a critical point for robustness because it is the first step where the data sets are considered as a whole, as opposed to individual lattices. Robustness is conferred by reformulating the error-calibration procedure to have fewer and less stringent statistical assumptions and incorporating the ability to down-weight low-quality lattices. We then apply this method to five macromolecular XFEL data sets and observe the improvements to each. The appropriateness of the intensity uncertainties is demonstrated through internal consistency. This is performed through theoretical CC 1/2 and I /σ relationships and by weighted second moments, which use Wilson's prior to connect intensity uncertainties with their expected distribution. This work presents new mathematical tools to analyze intensity statistics and demonstrates their effectiveness through the often underappreciated process of uncertainty analysis.

Mittan-Moreau, David W.↗

Phase Drifts and Signal Dispersion in Coaxial Cables

Phase reference distribution is a critical challenge in modern linear particle accelerators, such as European Spallation Source (ESS), European X-ray Free Electron Laser (E-XFEL), or Proton Improvement Plan II (PIP-II). Similar issues may also arise in other RF systems that need to synchronize many independent circuits. Achieving low phase drift of the reference signal requires careful selection of cables and their environmental operating conditions. Due to the limited data provided by cable manufacturers, it is necessary to characterize the cable performance. This article investigates the phase drifts in coaxial cables and presents a dedicated measurement methodology. The dispersion characteristics of the cables are also examined. The measurement results of various coaxial cables are presented, along with conclusions and practical guidelines for designers of phase reference distribution lines.

coaxial cables↗

First Soft X-ray Quantum Efficiency Measurements on Microwave Annealed Thin-Entrance Window Sensors

Free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250eV-1.5KeV. In addition, there are other light sources such as the FERMI, EuXFEL, and FLASH XFELs, as well as numerous synchrotrons such as the ALS, where soft x-ray science would benefit from detectors with higher quantum efficiency in the 20 eV to 1.5KeV range.A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. Previously, SRP and SIMS measurements were used to characterize the shallow dopant profile, and sensors with the new entrance window process were deployed successfully to measure an Fe-55 x-ray spectrum. For the first time, we present quantum efficiency measurement for soft x-rays. Furthermore, the resulting estimate of the entrance window is 20nm for an arsenic implanted entrance window and 55nm for a boron implanted entrance window.

47 OTHER INSTRUMENTATION↗

Optical damage considerations in the design of the matter in extreme condition upgrade (MEC-U) laser systems

The Matter in Extreme Conditions Upgrade (MEC-U) project is a major upgrade to the MEC instrument of the LINAC Coherent Light Source (LCLS) X-ray free electron laser (XFEL) user facility at SLAC National Accelerator Laboratory. Here, the envisioned MEC upgrade will significantly enhance the capabilities of the pump laser sources in current MEC experimental station, boosting the energy of the nanosecond shock driver from 100 J to the kJ level, and increasing the power and repetition rate of the short pulse laser from 25 TW at 5 Hz to 1 PW at 10 Hz rate. Building such high energy/power pump laser systems presents challenges to minimize and mitigate against laser-induced optical damage. Here, as part of the system design, we have identified the optics at high-risk to damage and we have designed the laser systems to mitigate against these damage risks to ensure sustained facility operation.

Coating↗

Double grating shearing interferometry for X-ray free-electron laser beams

The advancements in bright and coherent X-ray free-electron lasers (XFEL) have in the last decade revolutionized diverse fields of study, leading to an ever-increasing demand in more intense X-ray pulses. The accurate knowledge of the wavefront and the focal profile of such pulses ultimately dictates much of the experimental outcome.Herewe present a singleshot shearing interferometry method to measure the wavefront of a focused hardXFELpulse.Twoidentical transmission gratings are placed near the focus, and the interference pattern of overlapping diffraction orders is analyzed, resulting in a two-dimensional reconstruction of the X-ray wavefront. The spatial resolution and wavefront sensitivity can be tuned insitu during the measurement. The method is non-invasive (i.e., the zeroth order or transmitted pulse is not modified in intensity or profile), allowing for either a simultaneous intensity measurement at high resolution or a fully characterized transmitted pulse for general experimental use.

47 OTHER INSTRUMENTATION↗

Toward particle accelerator machine state embeddings as a modality for large language models

Understanding and diagnosing the state of a particle accelerator requires navigating high-dimensional control system data, often involving hundreds of interdependent parameters. We propose a novel multimodal embedding framework that jointly learns representations of machine states from both numerical control system readouts and natural language descriptions. This enables the translation of complex machine conditions into human-readable summaries while maintaining fidelity to the underlying physical system. The obtained embeddings are subsequently adapted to an open-weights large language model via cross-attention conditioning. We demonstrate a first implementation trained on European XFEL machine state data. This work covers the embedding model architecture, training methodology, and presents initial examples demonstrating the model's capabilities in action. Due to the general concept of machine state, the model can be easily adapted to other facilities and control system environments.

Accelerator Physics↗