Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window Length”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

225 records · Page 13

Predictive Modeling for Differential Diagnosis and Mortality Risk Assessment

The prevalence of electronic health record (EHR) systems has brought prodigious biomedical informatics opportunity. Automated machine learning methods can effectively utilize such data and have become common tools for healthcare predictive modeling. Researches in medical informatics have explored the potential of deep learning and classical models in emergent care scenarios. In particular, predicting differential diagnoses for admissions have proven useful in decreasing unnecessary lab tests and improving inpatient triage decision-making. Moreover, identification of high-risk patients for in-hospital mortality is vitally important to maximize allocation of medical resources.The Medical Information Mart for Intensive Care (MIMIC-III) database, containing de-identified critical care inpatient was used in our study. This data set captures hospital patient laboratory measurements, pharmacologic prescriptions, diagnostic data and procedure event recordings. When considering adult patients and discounting admissions with ICU length of stay less than 24 hours, there were 37,787 unique admissions and 30,414 total patients. We examined the top 25 most prevalent ICD-9 group-level disease specificities in MIMIC-III using a multi-label classification model. In-hospital mortality was modeled as binary classification with 4,155 (13%) adult patients that expired, of which 3,138 (75.5%) were in the ICU setting. The metrics AUC, F1 score, sensitivity and specificity values calculated for each disease label measured prediction performance.The usage of ICD-9 group codes reduced feature dimension from 14,567 to 942 and greatly improved distribution of patient diagnostic categories. Disease temporal patterns were captured by considering the most frequently sampled 6 vital signs and 13 laboratory values. Missing data were imputed at each time-stamp. Time-series raw hourly average values were converted into 5 summary features (mean, standard deviation, number of observations, min & max values). Patient demographic variables such as age, gender, marital status and ethnicity were also factored into the modeling. Choi et al showed that contextual embedding of medical data, diagnostic and procedural codes alone can predict future diagnoses with sensitivity as high as 0.79. We utilized an embedding technique called word2vec which allowed sparse representations of medical history to be transformed into dense word vectors. The mappings captured contextual information by treating each admission as a sentence and learning the most likely neighboring words in a sliding window fashion. Binary and multi-label classification was achieved via collapse models, which do not consider temporal information, as well as recurrent neural networks with regularization, Softmax output layer activation together with categorical cross-entropy as the loss function.

US Army collaboration↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

In Situ Visualization of Local Distortions in the High- T c Molecule-Intercalated Li x (C 5 H 5 N) y Fe 2– z Se 2 Superconductor

A time-resolved synchrotron X-ray total scattering study sheds light on the evolution of the different structural length scales involved during the intercalation of the layered iron–selenide host by organic molecular donors, aiming at the formation of the expanded-lattice Li x (C 5 H 5 N) y Fe 2– z Se 2 hybrid superconductor. The intercalates are found to crystallize in the tetragonal ThCr 2 Si 2 -type structure at the average level, however, with an enhanced interlayer iron–selenide spacing ( d = 16.2 Å) that accommodates the heterocyclic molecular spacers. Quantitative atomic pair distribution function (PDF) analysis at variable times suggests distorted FeSe 4 tetrahedral local environments that appear swollen with respect to those in the parent β-FeSe. Simultaneously acquired in situ synchrotron X-ray powder diffraction data disclose that secondary phases (α-Fe and Li 2 Se) grow significantly when a higher lithium concentration is used in the solvothermal reaction or when the solution is aged. These observations are in line with the strongly reducing character of the intercalation medium’s solvated electrons that mediate the defect chemistry of the expanded-lattice superconductor. In the latter, intralayer correlated local distortions indicate electron-donating aspects that reflect in somewhat enlarged Fe–Se bonds. Additionally, they also reveal a degree of relief of chemical pressure associated with a large distance between Fe and Se sheets (“taller” anion height) and a stretched Fe–Fe square planar topology. The elongation of the latter, derived from the in situ PDF study, speaks for a plausible increase in the Fe-site vacancy concentration. The evolution of the local structural parameters suggests an optimum reaction window where kinetically stabilized phases resemble the distortions of the edge-sharing Fe–Se tetrahedra, required for a high- T c in expanded-lattice iron-chalcogenides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multimodal Friction Ignition Tester

The multimodal friction ignition tester (MFIT) is a testbed for experiments on the thermal and mechanical effects of friction on material specimens in pressurized, oxygen-rich atmospheres. In simplest terms, a test involves recording sensory data while rubbing two specimens against each other at a controlled normal force, with either a random stroke or a sinusoidal stroke having controlled amplitude and frequency. The term multimodal in the full name of the apparatus refers to a capability for imposing any combination of widely ranging values of the atmospheric pressure, atmospheric oxygen content, stroke length, stroke frequency, and normal force. The MFIT was designed especially for studying the tendency toward heating and combustion of nonmetallic composite materials and the fretting of metals subjected to dynamic (vibrational) friction forces in the presence of liquid oxygen or pressurized gaseous oxygen test conditions approximating conditions expected to be encountered in proposed composite material oxygen tanks aboard aircraft and spacecraft in flight. The MFIT includes a stainless-steel pressure vessel capable of retaining the required test atmosphere. Mounted atop the vessel is a pneumatic cylinder containing a piston for exerting the specified normal force between the two specimens. Through a shaft seal, the piston shaft extends downward into the vessel. One of the specimens is mounted on a block, denoted the pressure block, at the lower end of the piston shaft. This specimen is pressed down against the other specimen, which is mounted in a recess in another block, denoted the slip block, that can be moved horizontally but not vertically. The slip block is driven in reciprocating horizontal motion by an electrodynamic vibration exciter outside the pressure vessel. The armature of the electrodynamic exciter is connected to the slip block via a horizontal shaft that extends into the pressure vessel via a second shaft seal. The reciprocating horizontal motion can be chosen to be random with a flat spectrum over the frequency range of 10 Hz to 1 kHz, or to be sinusoidal at any peak-to-peak amplitude up to 0.8 in. (.2 cm) and fixed or varying frequency up to 1 kHz. The temperatures of the specimen and of the vessel are measured by thermocouples. A digital video camera mounted outside the pressure vessel is aimed into the vessel through a sapphire window, with its focus fixed on the interface between the two specimens. A position transducer monitors the displacement of the pneumatic-cylinder shaft. The pressure in the vessel is also monitored. During a test, the output of the video camera, the temperatures, and the pneumatic-shaft displacement are monitored and recorded. The test is continued for a predetermined amount of time (typically, 10 minutes) or until either (1) the output of the position transducer shows a sudden change indicative of degradation of either or both specimens, (2) ignition or another significant reaction is observed, or (3) pressure in the vessel increases beyond a pre-set level that triggers an automatic shutdown.

Davis, Eddie↗

Sensorimotor Results from the Joint NASA and Russian Pilot Field Test

Testing of crew responses following long-duration flights has not previously been possible until a minimum of 24 hours after landing. As a result, it has not been possible to estimate the nonlinear trend of the early (<24 hours) recovery process, nor has it been possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented testing at the Soyuz landing site. This research effort has been identified as the Field Test (FT). For operational reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The PFT has now been completed with the landing of the crew of International Space Station Increment 42/43 (Soyuz expedition 41S). RESEARCH: The primary goal of this research was to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible (< 2 hours) with an additional two follow-up measurement sessions within 24 hours after landing. This study goal has both sensorimotor and cardiovascular elements. The PFT represented a initial evaluation of the feasibility of testing in the field and was comprised of a jointly agreed upon subset of tests drawn from the full FT and relied heavily on Russia's Institute of Biomedical Problems Sensory-Motor and Countermeasures Department for content and implementation. Data from the PFT was collected following several ISS missions. Testing on the U.S. side has included: (1) a sit-to-stand test, (2) recovery from a fall stand test where the crewmember begins in the prone position on the ground and then stands for 3.5 minutes while cardiovascular performance and postural ataxia data are acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors, and severity of postflight motion sickness were collected during each test session. In addition our Russian investigators have made measurements associated with: (a) obstacle avoidance, (b) muscle compliance, (c) postural adjustments to perturbations (pushes) applied to the subject's chest area and (d) center of mass measurements made across most test objectives with insoles inserted into the subjects' shoes. Data from 18 subjects have been obtained for a majority of the PFT objectives. SUMMARY: The increased level of functional deficit observed in the crewmembers tested with the PFT objectives has been typically greater than previously observed when measurements were collected after the 2 hr window. Significant improvement in crew performance was observed within 24 hours, but full recovery appears to require 6 to 16 days. Clearly measureable performance parameters such as ability to perform a seat egress, recovery from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured.

Reschke, Millard↗

U.S. Coast Guard Boat Recovery Simulation at the NASA Ames Vertical Motion Simulator

The U.S. Coast Guard routinely uses the Over-The-Horizon (OTH-IV), a cutter deployed, rigid-hulled inflatable boat for rescue and law enforcement operations. The term "cutter" refers to a Coast Guard vessel 65 feet in length or greater with accommodations for crew to live aboard and the ability to deploy smaller boats including the OTH-IV. A deployment method employed by some cutter class vessels is a davit crane system and specialized hook mechanism to connect the smaller boat. The launch and recovery operation requires several crewmembers, where one is tasked with releasing and connecting the hook to the small boat. Manipulating the hook can pose a risk to the crewmember depending on sea conditions combined with fatigue level or task expertise. Equipment and crewmembers are tested extensively due to the inherent risk of the task, but the sea conditions cannot be controlled. To address the sea condition variable, the U.S. Coast Guard and NASA leveraged the Vertical Motion Simulator (VMS) as a platform to test new equipment or train crewmembers in varying sea conditions. With 6 degrees of freedom and a vertical displacement of +/- 22ft, the VMS is capable of simulating conditions up to sea-state 5. The proof of concept experiment took place in September 2018 and demonstrated that the VMS can accurately simulate varying sea-states, collect performance data, and design a reliable and safe system for participants. The U.S. Coast Guard provided boat displacement data from the Large Amplitude Motion Program (LAMP). The program generates multi-directional waves with a cosine squared spreading function which produced a time history response of displacement data (surge, sway, heave, roll, pitch, yaw) of the OTH-IV's center of gravity (C.G). The displacement data was differentiated into acceleration evaluated at the crewmember's position at the front (bow) of the boat. Those accelerations were transformed to the VMS coordinate system and used as command inputs to the motion system's washout filters. The VMS uses Interchangeable Cabs (ICab) to perform flight simulations on a variety of aircraft or spacecraft configurations. An ICab typically contains seats, restraints, pilot controls, instrument panel, and out-the-window projectors all enclosed in a familiar cockpit configuration. To replicate the launch and recovery of a small boat, all the conventional features of a flight simulator and canopy were removed to be replaced with a to-scale OTH-IV bow mockup. The bow section was constructed from aluminum, and a connection point known as the davit ring. Additionally, a hook replica was suspended by a cable from the ceiling as if it were hanging from a davit crane aboard a cutter vessel. The last step was providing an auxiliary control to close the distance between suspended hook and the davit ring on the bow mockup. Without control the boat would simulate the wave motion, but with no guarantee that the crewmember will be in reach of the hook. Since the wave motion was repeatable, an additional acceleration command sent to the washout filters to move the simulator in the surge, sway, and heave directions, independently. The commands were rate limited such that the additional movement was not detectable with respect to the wave motion. The results showed that for each wave profile, a unique set of acceleration commands provided opportunities for crewmembers to gain control of the hook and connect it to the davit ring.

Riccobono, Nicholas S.↗

Mechanoadaptive strain and functional osseointegration of dental implants in rats

Spatiotemporal implant-bone biomechanics and mechanoadaptive strains in peri-implant tissue are poorly understood. Physical and chemical characteristics of an implant-bone complex (IBC) were correlated in three-dimensional space (along the length and around a dental implant) to gather insights into time related integration of the implant with the cortical portion of a jaw bone in a rat. Rats (N = 9) were divided into three experimental groups with three rats per time point; 3-, 11-, and 24-day. All rats were fed crumbled hard pellets mixed with water (soft-food diet) for the first 3 days followed by a hard-food diet with intact hard-food pellets (groups of 11- and 24-day only). Biomechanics of the IBCs harvested from rats at each time point was evaluated by performing mechanical testing in situ in tandem with X-ray imaging. The effect of physical association (contact area) of a loaded implant with adapting peri-implant tissue, and resulting strain within was mapped by using digital volume correlation (DVC) technique. The IBC stiffness at respective time points was correlated with mechanical strain in peri-implant tissue. Results illustrated that IBC stiffness at 11-day was lower than that observed at 3-day. However, at 24-day, IBC stiffness recovered to that which was observed at 3-day. Furthermore, correlative microscopy and spectroscopy illustrated that the lower IBC stiffness was constituted by softer and less mineralized peri-implant tissue that contained varying expressions of osteoconductive elements. Lower IBC stiffness observed at 11-day was constituted by less mineralized peri-implant tissue with osteoconductive elements that included phosphorus (P) which was co-localized with higher expression of zinc (Zn), and lower expression of calcium (Ca). Higher IBC stiffness at 24-day was constituted by mineralized peri-implant tissue with higher expressions of osteoconductive elements including Ca and P, and lower expressions of Zn. These spatiotemporal correlative maps of peri-implant tissue architecture, heterogeneous distribution of mineral density, and elemental colocalization underscore mechanoadaptive physicochemical properties of peri-implant tissue that facilitate functional osseointegration of an implant. These results provided insights into 1) plausible "prescription" of mechanical loads as an osteoinductive "therapeutic dose" to encourage osteoconductive elements in the peri-implant tissue that would facilitate functional osseointegration of the implant; 2) a "critical temporal window" between 3 and 11 days, and perhaps it is this acute phase during which key candidate regenerative molecules can be harnessed to accelerate osseointegration of an implant under load.

60 APPLIED LIFE SCIENCES↗

Data from: "Lab and Field Warming Similarly Advance Germination Date and Limit Germination Rate for High and Low Elevation Provenances of Two Widespread Subalpine Conifers"

This archive contains data used to draw conclusions in “Lab and Field Warming Similarly Advance Germination Date and Limit Germination Rate for High and Low Elevation Provenances of Two Widespread Subalpine Conifers”, by Kueppers et al. 2017. Cone collection and field experiments were conducted on Niwot Ridge, Colorado, with the latter completed within the Alpine Treeline Warming Experiment (ATWE). Laboratory germination experiments were conducted at the University of California Merced. Geospatial files are also provided for additional geographical context.There are four data file formats in this package: comma-separated values (.csv), Microsoft Excel (.xlsx), keyhole markup language (.kml), and ESRI shapefile (.shp). The latter two are geospatial file formats. .csv files can be opened using any simple text editor program such as TextEdit (Mac) and Notepad (Windows), and .xlsx files can be opened using Microsoft Excel or Google Sheets. The .kml file contains coordinate data, and is compatible with Google Earth and Google Maps. ESRI shapefiles (.shp) are compatible with any geospatial software able to read the file type, such as QGIS and ESRI’s ArcGIS Suite. This data user’s guide is available in as a .pdf, and can be opened using software such as Adobe Acrobat Reader.-----------------------------------------------------------------------------------------------------------------------------------Accurately predicting upslope shifts in subalpine tree ranges with warming requires understanding how future forest populations will be affected by climate change, as these are the seed sources for new tree line and alpine populations. Early life history stages are particularly sensitive to climate and are also influenced by genetic variation among populations. We tested the climate sensitivity of germination and initial development for two widely distributed subalpine conifers, using controlled-environment growth chambers with one temperature regime from subalpine forest in the Colorado Rocky Mountains and one 5 °C warmer, and two soil moisture levels. We tracked germination rate and timing, rate of seedling development, and seedling morphology for two seed provenances separated by ~300 m elevation. Warming advanced germination timing and initial seedling development by a total of ~2 weeks, advances comparable to mean differences between provenances. Advances were similar for both provenances and species; however, warming reduced the overall germination rate, as did low soil moisture, only for Picea engelmannii. A three-year field warming and watering experiment planted with the same species and provenances yielded responses qualitatively consistent with the lab trials. Together these experiments indicate that in a warmer, drier climate, P. engelmannii germination, and thus regeneration, could decline, which could lead to declining subalpine forest populations, while Pinus flexilis forest populations could remain robust as a seed source for upslope range shifts.

54 ENVIRONMENTAL SCIENCES↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗