Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Influence of insulating coating on aluminum wire explosions

Single wire explosions are widely used in understanding the early stages of z-pinch experiments. This paper presents a serial of experiments conducted on the pulse power generator with ∼1 kA peak current and ∼10 ns rising time in Xi'an Jiao Tong University. Polyimide coated aluminum wires and uncoated ones were tested under three different voltages to analyze the effect of insulating coating. Experimental results showed that insulating coating can increase the energy deposition 10%∼30% in aluminum wires by delaying the voltage collapse and raising the maximum load resistance. The substantial energy deposition resulted in about 20% faster expansion rates for coated wires. Experimental evidence that plasma channel shunts the current from the wire core was observed by streak camera and schlieren graphs. This paper also briefly discussed the influence of nonuniform coating on the morphology of wire expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of load voltage on voltage breakdown modes of electrical exploding aluminum wires in air

The effects of the load voltage on the breakdown modes are investigated in exploding aluminum wires driven by a 1 kA, 0.1 kA/ns pulsed current in air. From laser probing images taken by laser shadowgraphy, schlieren imaging, and interferometry, the position of the shockwave front, the plasma channel, and the wire core edge of the exploding product can be determined. The breakdown mode makes a transition from the internal mode, which involves breakdown inside the wire core, to the shunting mode, which involves breakdown in the compressed air, with decreasing charging voltage. The breakdown electrical field for a gaseous aluminum wire core of nearly solid density is estimated to be more than 20 kV/cm, while the value for gaseous aluminum of approximately 0.2% solid density decreases to 15–20 kV/cm. The breakdown field in shunting mode is less than 20 kV/cm and is strongly affected by the vaporized aluminum, the desorbed gas, and the electrons emitted from the wire core during the current pause. Ohmic heating during voltage collapses will induce further energy deposition in the current channel and thus will result in different expansion speeds for both the wire core and the shockwave front in the different modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi frame synchrotron radiography of pulsed power driven underwater single wire explosions

We present herein the first use of synchrotron-based phase contrast radiography to study pulsed-power driven high energy density physics experiments. Underwater electrical wire explosions have become of interest to the wider physics community due to their ability to study material properties at extreme conditions and efficiently couple stored electrical energy into intense shock waves in water. The latter can be shaped to provide convergent implosions, resulting in very high pressures (1-10 Mbar) produced on relatively small pulsed power facilities (100s of kA-MA). Multiple experiments have explored single-wire explosions in water, hoping to understand the underlying physics and better optimize this energy transfer process; however, diagnostics can be limited. Optical imaging diagnostics are usually obscured by the shock wave itself; and until now, diode-based X-ray radiography has been of relatively low resolution and rather a broad x-ray energy spectrum. Utilising phase contrast imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility, we were able to image both the exploding wire and the shock wave. Probing radiation of 20-50 keV radiographed 200 μm tungsten and copper wires, in ~2-cm diameter water cylinders with resolutions of 8 μm and 32 μm. The wires were exploded by a ~30-kA, 500-ns compact pulser, and 128 radiographs, each with a 100-ps X-ray pulse exposure, spaced at 704 ns apart were taken in each experiment. Abel inversion was used to obtain the density profile of the wires, and the results are compared to two dimensional hydrodynamic and one dimensional magnetohydrodynamic simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-speed imaging of transition from fluid breakup to phase explosion in electric explosion of tungsten wires in air

High-speed visible imaging of sub-microsecond electric explosion of wires at the low specific energy deposition threshold reveals three distinct modes of wire failure as capacitor charge voltage and energy deposition are increased. For 100 micron diameter gold-plated tungsten wires of 2 cm length, deposited energies of 1.9 eV/atom produces a liquid column that undergoes hydrodynamic breakup into droplets with radii of order of wire diameter on timescales of 200 μs. Instability growth, column breakup, and droplet coalescence follow classic Rayleigh-Plateau predictions for instability of viscous fluid column. Above 3.2 eV/atom of deposited energy, wires are seen to abruptly transition to an expanding mixture of micron scale liquid-droplets and vapor within one frame (less than 3.33 μs), which has been termed ‘phase explosion’ in literature. Between these two limits, at 2.5 eV/atom of deposited energy, wire radius is unchanged for the first 10 μs before the onset of a rapid expansion and disintegration that resembles homogenous nucleation of mechanically unstable bubbles. Here, thermodynamic calculations are presented that separate cases by temperature obtained during heating: below boiling point, near boiling point, and exceeding boiling point.

42 ENGINEERING↗

Study of the implosion characteristics of quasi-spherical wire arrays on the Angara-5-1 facility at currents of up to 4 MA

Results are presented from experimental studies of the spatial distribution of the density of matter in the central part of the discharge gap and the formation of the temporal profile of the X-ray power in the course of implosion of quasi-spherical wire arrays at discharge currents of up to 4 MA. The spatial distribution of the X-ray intensity in the central part of the discharge gap and the temporal profile of the X-ray power are used as implosion characteristics of quasi-spherical wire arrays. The quasi-spherical arrays were formed by the radial stretching of unstrained wires of initially cylindrical and conical wire arrays under the action of the electrostatic field. The temporal profile of the output X-ray pulse in the photon energy range of 0.1-1 keV is shown to depend on both the geometrical parameters of the quasi-spherical array and the longitudinal distribution of its mass. It is found that a 40% increase in the wire mass due to deposition of an additional mass in the equatorial region of a quasi-spherical array leads to a 15% increase in the average current radius of the pinch and a 30% decrease in the X-ray yield. Experiments with quasi-spherical arrays made of kapron fibers with deposited Al and Bi conducting layers were also carried out. It is demonstrated that application of such arrays makes it possible to control the profile and duration of the generated X-ray pulse by varying the mass, material, and location of the deposited layer. It is found that deposition of an additional mass in the form of a thin Bi stripe on tungsten wires near the cathode end of the array allows one to mitigate the influence of the cathode zipper effect on the pinch compression and formation of the X-ray pulse in tungsten arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Temperature Testing of Advanced Manufactured Melt Wire Package

As a part of the In-Pile Instrumentation Program, The Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced manufactured sensors for measuring the peak irradiation temperature inside a nuclear test reactor. Although nuclear test reactors can use standard methods of real-time temperature monitoring, such as thermocouples, the complexity of feedthroughs and attachment complications to collect real-time measurements greatly increases the cost of the experiment. Passive monitoring techniques may be utilized that exploit the melting point of well characterized material (standard melt wires), however, the limited space available for instrumentation during experiments is also a challenge. To accommodate the challenge, INL has expanded its temperature detection instrumentation capabilities paired with the advancement of in-house advanced manufacturing options to include printed melt wires for peak irradiation temperature measurement. The advanced manufactured melt wire package can determine peak temperatures in experiments that can fit the challenging space available during irradiation. Recent results and knowledge from this ongoing work have made it possible to develop unique temperature sensors that can accomplish user specific temperature ranges inside the harsh environments experienced during radiation testing. This report summarizes the initial temperature testing using fabricated melt wires with two different melting temperatures, silver (melting temperature of ~960 °C) and solder (melting temperature of ~160 °C), that were initially tested for their relative melting points using non-standard method of furnace and hot plate testing under normal air conditions. Future work will include more controlled way of testing printed melt wires under inert gas with multiple temperature measurements followed by comparison of standard melt wire package performance for baseline characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additive manufacturing enabled hot-wire apparatus with suppressed edge effect error

This invention describes a method of structuring a metal or metal coated wire in a manner such that it provides enhanced accuracy when used in a hot-wire apparatus for transient thermal conductivity measurements for low-density materials. This is accomplished by using a diameter varying structure with two ends of the wire of sufficiently small diameter that the edge-effect induced error can be reduced by generating a more uniform temperature profile along the wire, whereas in conventional apparatus the temperatures always drop at the ends of a finite wire due to its ends that are being cooled by the wire-supports.

36 MATERIALS SCIENCE↗

Surface characteristics and damage distributions of diamond wire sawn wafers for silicon solar cells

This paper describes surface characteristics, in terms of its morphology, roughness and near-surface damage of Si wafers cut by diamond wire sawing (DWS) of Si ingots under different cutting conditions. Diamond wire sawn Si wafers exhibit nearly-periodic surface features of different spatial wavelengths, which correspond to kinematics of various movements during wafering, such as ingot feed, wire reciprocation, and wire snap. The surface damage occurs in the form of frozen-in dislocations, phase changes, and microcracks. The in-depth damage was determined by conventional methods such as TEM, SEM and angle-polishing/defect-etching. However, because these methods only provide local information, we have also applied a new technique that determines average damage depth over a large area. This technique uses sequential measurement of the minority carrier lifetime after etching thin layers from the surfaces. The lateral spatial damage variations, which seem to be mainly related to wire reciprocation process, were observed by photoluminescence and minority carrier lifetime mapping. Our results show a strong correlation of damage depth on the diamond grit size and wire usage.

14 SOLAR ENERGY↗

Staphylococcus-Infected Tunneled Dialysis Catheters: Is Over-the-Wire Exchange an Appropriate Management Option?

Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n = 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System

PurposeWe retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS).MethodsEleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0.ResultsThe hook wire was successfully placed using the transfissural route in all but one case. Of these ten successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed.ConclusionsThe transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge Transport through Organic Molecular Wires Embedded in Ultrathin Insulating Inorganic Layer

Dense phase silica layers with thickness of a few nanometers featuring embedded organic molecular wires of type p-oligo(phenylenevinylene) are shown by visible light sensitized electrochemical measurements to transport charges across the insulating membrane. Here, we find that such hybrid materials combination allows electronic charge transport only through the wires, while blocking molecular transport. Embodiment of the wire molecules in the silica was accomplished by atomic layer deposition under mild temperature conditions. Grown on Co oxide films for water oxidation, with the wire molecules covalently anchored on the oxide surface, the layer functions as a proton conducting separation membrane. Characterization by XPS, FT-IR and STEM/EDX confirms the integrity of the silica-encapsulated organic wires. Cyclic voltammetry with redox couple of selected potential relative to the energy levels of the wire molecules shows that the membrane is free of pinholes. The new type of membrane allows separation of incompatible redox reaction environments on the length scale of nanometers while enabling controlled electron transport between them. Finally, this opens up the coupling of carbon dioxide reduction with water oxidation, the essential reactions of artificial photosynthesis, in an integrated nanoscale photosystem.

36 MATERIALS SCIENCE↗

Magnetic control over the fundamental structure of atomic wires

When reducing the size of materials towards the nanoscale, magnetic properties can emerge due to structural variations. Here, we show the reverse effect, where the structure of nanomaterials is controlled by magnetic manipulations. Using the break-junction technique, we find that the interatomic distance in platinum atomic wires is shorter or longer by up to ~20%, when a magnetic field is applied parallel or perpendicular to the wires during their formation, respectively. The magnetic field direction also affects the wire length, where longer (shorter) wires are formed under a parallel (perpendicular) field. Our experimental analysis, supported by calculations, indicates that the direction of the applied magnetic field promotes the formation of suspended atomic wires with a specific magnetization orientation associated with typical orbital characteristics, interatomic distance, and stability. A similar effect is found for various metal and metal-oxide atomic wires, demonstrating that magnetic fields can control the atomistic structure of different nanomaterials when applied during their formation stage.

36 MATERIALS SCIENCE↗

Self-assembly of tin wires via phase transformation of heteroepitaxial germanium-tin on germanium substrate

This work demonstrates and describes for the first time an unusual strain-relaxation mechanism by the formation and self-assembly of well-ordered tin wires during the thermal annealing of epitaxial Ge{sub 0.83}Sn{sub 0.17}-on-Ge(001) substrate. Fully strained germanium-tin alloys (Ge{sub 0.83}Sn{sub 0.17}) were epitaxially grown on Ge(001) substrate by molecular beam epitaxy. The morphological and compositional evolution of Ge{sub 0.83}Sn{sub 0.17} during thermal annealing is studied by atomic force microscopy, X-ray diffraction, transmission electron microscopy. Under certain annealing conditions, the Ge{sub 0.83}Sn{sub 0.17} layer decomposes into two stable phases, and well-defined Sn wires that are preferentially oriented along two orthogonal 〈100〉 azimuths are formed. The formation of the Sn wires is related to the annealing temperature and the Ge{sub 0.83}Sn{sub 0.17} thickness, and can be explained by the nucleation of a grain with Sn islands on the outer front, followed by grain boundary migration. The Sn wire formation process is found to be thermally activated, and an activation enthalpy (E{sub c}) of 0.41 eV is extracted. This thermally activated phase transformation, i.e., 2D epitaxial layer to 3D wires, occurs via a mechanism akin to “cellular precipitation.” This synthesis route of Sn wires opens new possibilities for creation of nanoscale patterns at high-throughput without the need for lithography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Variation of effective filament diameter, irreversibility field, anisotropy, and pinning efficiency in Bi-2212 round wires

Abstract In recent years Bi 2 Sr 2 CaCu 2 O x (Bi-2212) received increasing attention due to its round wire multifilamentary architecture, a unique feature in high- T c superconductor. In fact, round wires are preferable for magnet designs, including solenoids for nuclear magnetic resonance (NMR) or research purpose and accelerator magnets. However, due to the narrow over-pressure heat treatment conditions necessary to obtain high J c and to the peculiar microstructure of Bi-2212 wires, a full understanding of the correlations between the different properties has not yet been developed. In this paper we investigate the effect of a vital part of Bi-2212 optimization, the maximum heat-treatment temperature T max in the range of 885 °C–896 °C, on the variations of J c , effective filament diameter d eff , anisotropy γ , INTER- and intra-grain irreversibility fields and pinning energies U 0 , all critical parameters in unravelling the complex mix of vortex pinning and connectivity that ultimately determines the critical current density. We found that d eff of the higher J c wires heat-treated at lower temperature is much smaller than for the lower J c wires. Moreover, a systematic increase of the irreversibility field and a decrease of the intrinsic Bi-2212 anisotropy underpins the higher J c . The analysis of the pinning energies reveals that there is little sample-to-sample variation in the INTER-grain pinning, whereas in all samples the intra-grain pinning has an enhancement below ∼40–45 K becoming more and more evident with increasing J c . These results suggest that the overall J c performance are not only related to the wire microstructure and connectivity, which obviously affect the INTER-grain properties, but they are also intimately related to the intrinsic and intra-grain properties such as γ and U 0 .

Physics↗

Optical Absorption Spectroscopy Probes Water Wire and Its Ordering in a Hydrogen-Bond Network

Water wires, quasi-one-dimensional chains composed of hydrogen-bonded (H-bonded) water molecules, play a fundamental role in numerous chemical, physical, and physiological processes. Yet direct experimental detection of water wires has been elusive so far. Based on advanced many-body theory that includes electron-hole interactions, we report that optical absorption spectroscopy can serve as a sensitive probe of water wires and their ordering. In both liquid and solid water, the main peak of the spectrum is discovered to be a charge-transfer exciton. In water, the charge-transfer exciton is strongly coupled to the H-bonding environment where the exciton is excited between H-bonded water molecules with a large spectral intensity. In regular ice, the spectral weight of the charge-transfer exciton is enhanced by a collective excitation occurring on proton-ordered water wires, whose spectral intensity scales with the ordering length of water wire. The spectral intensity and excitonic interaction strength reaches its maximum in ice XI, where the long-range ordering length yields the most pronounced spectral signal. Our findings suggest that water wires, which widely exist in important physiological and biological systems and other phases of ice, can be directly probed by this approach. Published by the American Physical Society 2025

Tang, Fujie (ORCID:0000000197615359)↗

Critical Current Distributions of Recent Bi-2212 Round Wires

Bi 2 Sr 2 CaCu 2 O 8+x (Bi-2212) is the only high-field, high-temperature superconductor (HTS) capable of reaching a critical current density J c (16 T, 4.2 K) of 6500 A·mm –2 in the highly desirable round wire (RW) form. However, state-of-the-art Bi-2212 conductors still have a critical current density (J c ) to depairing current density (J d ) ratio around 20 to 30 times lower than that of state-of-the-art Nb–Ti or REBCO. Previously, we have shown that recent improvements in Bi-2212 RW J c are due to improved connectivity associated with optimization of the heat treatment process, and most recently due to a transition to a finer and more uniform powder manufactured by Engi-Mat. One quantitative measure of connectivity may be the critical current (I c ) distribution, since the local I c in a wire can vary along the length due to variable vortex-microstructure interactions and to factors such as filament shape variations, grain-to-grain connectivity variations and blocking secondary phase distributions. Modeling the experimental V-I transition measured on a low resistance shunt as a complex sum of voltage contributions of individual filament and wire sub-sections allows a numerical extraction of the I c distribution from the d 2 V/dI 2 treatment of the V-I curves. Here we compare ~0.1 m length I c distributions of Bi-2212 RWs with recent state-of-the-art very high-J c Engi-Mat powder and lower J c and older Nexans granulate powder. We do find that the I c spread for Bi-2212 wires is about twice the relative standard of high-J c Nb–Ti well below H irr . We do not yet see any obvious contribution of the Bi-2212 anisotropy to the I c distribution and are rather encouraged that these Bi-2212 round wires show relative I c distributions not too far from high-J c Nb–Ti wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Increase in the energy density of the pinch plasma in 3D implosion of quasi-spherical wire arrays

Results are presented from experimental studies of the characteristics of the soft X-ray (SXR) source formed in the implosion of quasi-spherical arrays made of tungsten wires and metalized kapron fibers. The experiments were carried out at the Angara-5-1 facility at currents of up to 3 MA. Analysis of the spatial distribution of hard X-ray emission with photon energies above 20 keV in the pinch images taken during the implosion of quasi-spherical tungsten wire arrays (QTWAs) showed that a compact quasi-spherical plasma object symmetric with respect to the array axis formed in the central region of the array. Using a diffraction grazing incidence spectrograph, spectra of SXR emission with wavelengths of 20–400 Å from the central, axial, and peripheral regions of the emission source were measured with spatial resolutions along the array radius and height in the implosion of QTWAs. It is shown that the emission spectra of the SXR sources formed under the implosion of quasi-spherical and cylindrical tungsten wire arrays at currents of up to 3 MA have a maximum in the wavelength range of 50–150 Å. It is found that, during the implosion of a QTWA with a profiled linear mass, a redistribution of energy in the emission spectrum takes place, which indicates that, during 3D implosion, the energy of longitudinal motion of the array material additionally contributes to the radiation energy. It is also found that, at close masses of the arrays and close values of the current in the range of 2.4{sup −3} MA, the average energy density in the emission source formed during the implosion of a quasi-spherical wire array is larger by a factor of 7 than in the source formed during the implosion of a cylindrical wire array. The experimental data were compared with results of 3D simulations of plasma dynamics and radiation generation during the implosion of quasi-spherical wire arrays with a profiled mass by using the MARPLE-3D radiative magnetohydrodynamic code, developed at the Keldysh Institute of Applied Mathematics, Russian Academy of Sciences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring Randomly Wired Neural Networks for Climate Model Emulation

Exploring the climate impacts of various anthropogenic emissions scenarios is key to making informed decisions for climate change mitigation and adaptation. State-of-the-art Earth system models can provide detailed insight into these impacts but have a large associated computational cost on a per-scenario basis. This large computational burden has driven recent interest in developing cheap machine learning models for the task of climate model emulation. In this paper, we explore the efficacy of randomly wired neural networks for this task. We describe how they can be constructed and compare them with their standard feedforward counterparts using the ClimateBench dataset. Specifically, we replace the serially connected dense layers in multilayer perceptrons, convolutional neural networks, and convolutional long short-term memory networks with randomly wired dense layers and assess the impact on model performance for models with 1 million and 10 million parameters. We find that models with less-complex architectures see the greatest performance improvement with the addition of random wiring (up to 30.4% for multilayer perceptrons). Furthermore, of 24 different model architecture, parameter count, and prediction task combinations, only one had a statistically significant performance deficit in randomly wired networks relative to their standard counterparts, with 14 cases showing statistically significant improvement. We also find no significant difference in prediction speed between networks with standard feedforward dense layers and those with randomly wired layers. These findings indicate that randomly wired neural networks may be suitable direct replacements for traditional dense layers in many standard models.

54 ENVIRONMENTAL SCIENCES↗