Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Tidal volume single-breath washin of SF6 and CH4 in transient microgravity

We performed tidal volume single-breath washins (SBW) by using tracers of different diffusivity and varied the time spent in microgravity (microG) before the start of the tests to look for time-dependent effects. SF(6) and CH(4) phase III slopes decreased by 35 and 26%, respectively, in microG compared with 1 G (P < 0.05), and the slope difference between gases disappeared. There was no effect of time in microG, suggesting that neither the hypergravity period preceding microG nor the time spent in microG affected gas mixing at volumes near functional residual capacity. In previous studies using SF(6) and He (Lauzon A-M, Prisk GK, Elliott AR, Verbanck S, Paiva M, and West JB. J Appl Physiol 82: 859-865, 1997), the vital capacity SBW showed an increase in slope difference between gases in transient microG, the opposite of the decrease in sustained microG. In contrast, tidal volume SBW showed a decrease in slope difference in both microG conditions. Because it is only the behavior of the more diffusive gas that differed between maneuvers and microG conditions, we speculate that, in the previous vital capacity SBW, the hypergravity period preceding the test in transient microG provoked conformational changes at low lung volumes near the acinar entrance.

Parabolic Flight↗

Restoration of plasma volume after 16 days of head-down tilt induced by a single bout of maximal exercise

Seven healthy men performed maximal exercise 24 h before the end of 16 days exposure to 6 degrees head-down tilt (HDT) to test the hypothesis that such an exercise technique could restore plasma volume (PV) at the end of a simulated space mission. Exercise consisted of supine cycling with graded work rates increasing by 16 W/min to volitional fatigue and required an average of 16 min. The experimental protocol was a standard cross-over design in which the order of treatment (exercise or control) was counterbalanced across all seven subjects. PV, fluid intake (ad libitum), urine output, renal function, and hormones associated with fluid homeostasis were measured before HDT, 24 h before the end of HDT just prior to exercise, and at the end of HDT 24 h after exercise. HDT reduced PV by 16% in both control and exercise conditions. Maximal exercise completely restored plasma volume within 24 h to 3.9 +/- 3.2% of pre-HDT levels despite continued HDT. Compared with control, exercise induced a 660-ml larger positive fluid balance because of greater fluid intake and reduced urine volume during the 24 h after exercise. These results suggest that one bout of maximal leg exercise before return from 16 days of spaceflight may be completely effective in stimulating thirst and restoring plasma volume to preflight levels.

Non-NASA Center↗

Blood volume responses of men and women to bed rest

This paper reviews a series of studies that indicate that estrogens play an important role in blood volume regulation. The first study illustrates that the plasma volume (PV) of ambulatory women fluctuates during the menstrual cycle, increasing during periods of elevated estrogens. In the second study, it was shown that exogenous and endogenous elevations in blood estrogens attenuate the decrease in PV during bed rest. In the third study, the hypothesis was tested that women, who naturally have a higher blood estrogen content compared with men, will have a smaller loss of PV during bed rest. Ten men and ten women underwent a 13-day, 6 degrees head-down bed rest. Plasma volume and red cell mass (RCM) were measured before and after bed rest using 125I and 51Cr labeling, respectively. Before bed rest, the men and women had similar blood volume (BV) and PV (mL/kg body weight), but the women had a smaller (P < .01) RCM (22.2 +/- 0.9 versus 26.2 +/- 0.8 mL/kg, mean +/- SE). During bed rest, the decrease in RCM (mL/kg) was similar in men and women. However, the decrease in BV was greater in men (8.0 +/- 0.8 mL/kg versus 5.8 +/- 0.8 mL/kg), because of a greater reduction in PV (6.3 +/- 0.6 mL/kg versus 4.1 +/- 0.6 mL/kg). Because the decline in BV has been proposed to contribute to the cardiovascular deconditioning after bed rest, it is possible that women may experience less cardiac and circulatory strain on reambulation.

Review, Tutorial↗

A Multi-Sensor, Low Volume, Automated Culture System for Space Biology Experiments

Optical density (absorbance) is commonly used in microbiology to measure cell concentration and other colorimetric indicators. It is the main type of bioscience data returned from the BioSentinel small spacecraft mission, which was recently launched as a secondary payload on Artemis I. The flight unit takes absorbance measurements of yeast cultures at 570 nm, 630 nm, and 850 nm to track cell concentration and oxidation-reduction (redox) state of the metabolic indicator dye alamarBlue over time [1]. Because the data returned from a small spacecraft mission is necessarily limited, BioSentinel uses a specialized ground-based experiment apparatus to map the absorbance data onto several other parameters. This culture apparatus is composed of a polycarbonate base and lid which contain ports for several commercial sensors, including a standard 12 mm dissolved oxygen probe, gaseous CO2, fluid pressure, and two micro-probes for measuring pH and redox potential. It also contains a pressure relief valve, a rubber membrane for culture interaction, and a 12mm port for the custom optical probe designed to match in-flight measurements. Modules in two corners expand the culture volume into narrow columns, enabling solid-state optical density measurement and dielectric spectroscopy. The apparatus can be fit to a plate for magnetic stirring. The apparatus’s optical probe allows mapping between the flight unit’s optical data and the additional parameters measured by the ground-based experiments. Within the probe, a linear actuator pulls a plunger, drawing culture volume into the optical path. The actuator then pushes out the plunger and culture volume, cleaning any stray yeast from the inside surface of the probe. The probe chassis is 3D-printed from biocompatible resin with the optoelectronics cured inside an optically clear conformal coat which functions as a lens. To optimize the probe’s dimensions, including optical path, a test harness was developed to manipulate and measure distance while the LED light sources and photodiode detector are in operation. The test harness was composed of two 3/64” thick polycarbonate plates mounted to a set of calipers. The LEDs and photodiode were mounted on the outside of each plate. A cuvette of sample fluid was then clamped between the plates in line between the LEDs and photodiode. The test harness generated a 78% signal change between water and a dye standard for the green (570 nm) LED, a 90% signal change for the red (630 nm) LED, and a 25% signal change between water and overgrown yeast for the infrared (850 nm) LED. The improvements to the ground experiment apparatus (culture volume reduction, inclusion of an optical probe to measure flight-like optical data, and magnetic stirring for culture homogeneity) allow for more flight-like measurements to be taken and more accurate mapping of these additional parameters to the optical data returned from the flight unit. This enhancement to mission science return will give insight into how deep space radiation may affect human biology for future long-term space exploration.

Multi-Sensor↗

Research Summary No. 36-3, Volume I, Part II

The Research Summary is a bimonthly report of supporting research and development conducted at the Jet Propulsion Laboratory. This periodical is issued in three volumes. Volume I contains summaries of the work accomplished by the Space Sciences, Systems, Guidance and Control, and Telecommunications Divisions of the Laboratory. Volume II contains summaries of the work accomplished by the Physical Sciences, Engineering Mechanics, Engineering Facilities, and Propulsion Divisions. All work of a classified nature is contained in Volume Ill.

Source record↗

Research Summary No. 36-6, Volume II

The Research Summary is a bimonthly report of supporting research and development conducted at the Jet Propulsion Laboratory. This periodical is issued in three volumes. Volume I contains summaries of the work accomplished by the Space Sciences, Systems, Guidance and Control, and Telecommunications Divisions of the Laboratory. Volume II contains summaries of the work accomplished by the Physical Sciences, Engineering Mechanics, Engineering Facilities, and Propulsion Divisions. All work of a classified nature is contained in Volume Ill.

Source record↗

Research Summary No. 36-5, Volume II

The Research Summary is a bimonthly report of supporting research and development conducted at the Jet Propulsion Laboratory. This periodical is issued in three volumes. Volume I contains summaries of the work accomplished by the Space Sciences, Systems, Guidance and Control, and Telecommunications Divisions of the Laboratory. Volume II contains summaries of the work accomplished by the Physical Sciences, Engineering Mechanics, Engineering Facilities, and Propulsion Divisions. All work of a classified nature is contained in Volume Ill.

Source record↗

Research Summary No. 36-3, Volume I, Part I

The Research Summary is a bimonthly report of supporting research and development conducted at the Jet Propulsion Laboratory. This periodical is issued in three volumes. Volume I contains summaries of the work accomplished by the Space Sciences, Systems, Guidance and Control, and Telecommunications Divisions of the Laboratory. Volume II contains summaries of the work accomplished by the Physical Sciences, Engineering Mechanics, Engineering Facilities, and Propulsion Divisions. All work of a classified nature is contained in Volume Ill.

Source record↗

Theory and Practical Design of Phase-locked Receivers, Volume I

This is Volume I of a two-volume work on the theory, of phase-locked receivers, with pertinent reference material on practical receiver design. Volume I is primarily devoted to the performance of carrier-tracking loops, including a rigorous treatment of narrow-band systems having IF limiters. The bulk of the work is based on a theoretical linear model, but a nonlinear method is also presented to predict behavior near the threshold. The emphasis throughout the work is toward completeness, simplicity, and internal consistency of the material assembled. Part I of this Volume is an exposition of the theory, the resulting equations, and the design philosophy that have enabled the phase-lock concept to evolve into the basic principle underlying the most sensitive receivers il, the world today. Part II is a condensed version of Part I, intended as a quick reference to formulas, definitions, and salient design considerations.

RECEIVER↗

Publications of Goddard Space Flight Center, 1964. Volume I - Space sciences

This publication is a collection of articles, papers, talks, and reports generated by the scientific and engineering staff of Goddard Space Flight Center in the year 1964. Many of these articles were originally published in scientific or engineering Journals or as official NASA technical publications, while other are documents of a more informal nature. All are reprinted here as nearly verbatim as typography and format will permit. These articles are grouped into broad subject categories, but no detailed subdivision has been made. Within each category, the articles are arranged alphabetically by author. An overall author index is given in the back of the volume. The years 1963, 1964, and 1965 are being published as whole-year issues, and the resulting size dictates the use of two volumes; the first volume is titled Space Sciences, and the second Space Technology. It is anticipated, however, that future issues will be quarterly single volumes.

IONOSPHERE↗

Water-glycol system volume calculation

Two methods calculate the volume of a thermodynamic system. Integral method uses an iterative solution to determine volume based on constants of liquid mass and gas mass. Differential method approximates volume by its initial values plus first-order differential changes in volume as functions of temperature and pressure.

Liley, B.↗

Peripheral venous scintillation angiocardiography in determination of left ventricular volume in man.

Left ventricular end-diastolic volume was determined by cardiac visualization after peripheral venous injection of a gamma-emitting isotope in 10 patients with organic heart disease. The left ventricular end-diastolic volume measured by the isotope method consistently averaged 9% less than that determined by the X-ray method. The mean difference in left ventricular end-diastolic volume was 21 ml. Excellent correlation between the two methods was observed. It is pointed out that peripheral venous scintillation angiocardiography compares well with left ventriculography in the determination of left ventricular end-diastolic volume in man.

Sullivan, R. W.↗

Passenger fluid volumes measured before and after a prolonged commercial jet flight.

Interstitial and intracellular fluid volumes were calculated from measured plasma volume, extracellular volume and total body water of six subjects before and after a 24-hour commercial overseas flight. No change occurred in these spaces or in peripheral hematocrit or total serum protein concentration. The subjective feeling of dehydration and the actual swelling of the lower extremities characteristically found among passengers at the end of a long trip of this type seems to represent a shift in body fluids to the dependent portions of the body rather than water retention or a decrease in the intravascular water volume.

Johnson, P. C.↗

Comparative changes in plasma protein concentration, hematocrit and plasma volume during exercise, bedrest and + Gz acceleration.

Discussion of experiments which indicate that under conditions of a constant red cell volume the proportional changes in hematocrit and plasma volume during exercise are never equal. On the basis of direct measurements and calculated changes of plasma volume it is concluded that during maximal exercise there is a small loss of protein from the plasma. It is clear that changes in content of blood constituents can only be evaluated correctly after determination of changes in plasma volume.

Van Beaumont, W.↗

Study of X-ray diffraction on aging alloys with different degrees of volume discrepancy between the precipitation phase and the matrix

Study of the diffraction patterns of X rays diffracted by dispersion-hardened alloys with various degrees of difference between the specific atomic volumes of their precipitation phases and matrices. Experiments were performed on aging alloys KhN77TIuR (nimonic) and KhN67VMTIuO, which have the same types of gamma solid solutions and precipitating gamma prime phases, but differ considerably with respect to the volume factor. It is found that in the decay of supersaturated solid solutions for which the difference between the specific atomic volumes of the precipitation phase and the matrix is small (alloy KhN67VMTIuO) the nature of the intensity distribution of the diffraction lines remains practically unchanged regardless of the aging, while in cases where the volume discrepancy is large (alloy KhN77TIuR) significant changes in the appearance of the diffraction lines are recorded.-

Gitgarts, M. I.↗

A dilatometer for volume-temperature determinations of liquids.

An instrument is described for the continuous volume measurement of small (3.7 ml) samples of liquids as a function of temperature. The sample is sealed in a stainless steel bellows chamber. Volume changes are measured with a linear variable differential transformer while temperature is measured by means of a thermistor and associated circuitry. Volume changes can be determined to better than .1 microliter ml over a temperature range of 10-60 C. The maximum sample volume change is 7%.

Rothman, J. E.↗

Disproportional changes in hematocrit, plasma volume, and proteins during exercise and bed rest.

The interrelationships between the changes in plasma volume, hematocrit, and plasma proteins during muscular exercise and bed rest were investigated. Proportionally, the changes in hematocrit are always smaller than the changes in plasma volume. For this reason changes in the concentration of blood constituents can only be quantitated on the basis of plasma volume changes. During short periods of intensive exercise, there was a small loss of plasma proteins. With prolonged submaximal exercise there was a net gain in plasma protein, which contributes to stabilization of the vascular volume. Prolonged bed rest induced hypoproteinemia; this loss of plasma protein probably plays an important role in recumbency hypovolemia.

Van Beaumont, W.↗

The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

Burton, R. R.↗