Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Snake River Plain Geothermal Play Fairway Analysis - Volcanic Vents, Lacustrine Sediments, and post-Miocene Faults KMZ files

This dataset contain raw data files in kmz files (Google Earth georeference format). These files include volcanic vent locations and age, the distribution of fine-grained lacustrine sediments (which act as both a seal and an insulating layer for hydrothermal fluids), and post-Miocene faults compiled from the Idaho Geological Survey, the USGS Quaternary Fault database, and unpublished mapping. It also contains the Composite Common Risk Segment Map created during Phase 1 studies, as well as a file with locations of select deep wells used to interrogate the subsurface.

15 GEOTHERMAL ENERGY↗

Evaluation of Passive Vents in New Construction Multifamily Buildings

Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as a potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Evaluation of Passive Vents in New-Construction Multifamily Buildings, New York, New York

Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as a potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PRex: An Experiment to Investigate Detection of Near-field Particulate Deposition from a Simulated Underground Nuclear Weapons Test Vent

An experiment to release radioactive particles representative of small-scale venting from an underground nuclear test was conducted to gather data in support of treaty capability development activities. For this experiment, a CO2-driven “air cannon” was used to release lanthanum-140 at ambient temperatures. The radioisotope 140La was chosen as a representative fission fragment with a short half-life and prominent gamma-ray emissions; the choice was also influenced by the successful production and use of 140La with low levels of radioactive contaminants in the Defence Research and Development Canada Field Trials. The source was created through activation of high-purity lanthanum oxide at the TRIGA research reactor of Washington State University, Pullman, Washington. Witness plates and air samplers were laid out in an irregular grid covering the area for which the plume was anticipated to deposit based on climatological wind records. A vehicle-mounted spectrometer, and handheld and backpack instruments ranging from polyvinyl toluene to high purity germanium, were used to survey the plume. Additionally, three soil sampling techniques were investigated. The relative sensitivity and utility of sampling and survey methods are discussed in the context of On-Site Inspection.

atmospheric dispersion↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

This research involved construction of a conditioned test hut in a cold climate (Climate Zone 5A) with multiple side-by-side instrumented roof rafter bays. This work examined seven experimental unvented roofs and one code-compliant control hybrid ccSPF-cellulose roof over three winters and following summers. Examined variables included insulation material (fiberglass and cellulose), the presence or absence of a ridge diffusion vent (vapor-open material at the roof ridge to promote drying), the effect of various interior vapor control membranes (fixed and variable permeance), the effect of interior relative humidity, and the effect of interstitial airflow (from the interior into the cavity). This experiment was run over three winters, changing variables of interior conditions, roof configurations/materials, and the addition of intentional air leakage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid-State Thermodynamic Vent System (STVS) for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellant condition. By exploiting the vacuum-induced cryocooling (VIC) potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger (HX) can expel some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. Testing proved the effectiveness of the concept by reducing the liquid nitrogen (LN 2 ) boiloff rate and tank pressure by roughly 70% and 77%, respectively, during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Cryogenic Fluid↗

A Case Study of AI-assisted Creation of a Thermodynamics Model of Precipitation Formation During Rapid Depressurization of a Vented Container

Precipitation may form in humid containers undergoing rapid depressurization. This precipitation may be liquid, i.e. fog, if the dewpoint is crossed above the freezing point of water, or direct snow crystallization if the dewpoint is crossed below the freezing point. Accurate modeling of this effect is potentially important for rapidly ascending vented containers in aircraft, spacecraft, and launch vehicles, as well as rapidly depressurizing vacuum chambers. A transient thermodynamics model of precipitation formation during the rapid depressurization of a container was developed in python. The model is written for a generic container and includes an optional water pool and water vapor source. Details of the model and results from several example cases spanning the full capabilities of the model, including a validation case, will be presented. Although the model is not novel, in contrast to prior works, this one was treated as a case study of the assistance of AI Large Language Models (LLMs) to create physical models. Impressions, performance, time, and cost of using AI for this task will be discussed.

precipitation↗

Numerical study of multi-component flow and mixing in a scaled fission product venting system

Numerical simulation of isothermal multi-component gas flow was conducted to study fluid flow and mixing in a scaled low-pressure, low-temperature test facility for the fission product venting system (FPVS) of a gas cooled fast reactor (GFR). The geometry of FPVS test facility was an open loop including gradual expansion coupling and two 90°pipe elbows. First, the validation of large eddy simulation (LES) wall-adapting local eddy-viscosity (WALE) turbulent model was performed for transitional flow in a circular pipe with gradual expansion. The reactingFOAM solver in OpenFOAM v8 was employed. By introducing appropriate turbulence disturbance at the flow inlet, such as turbulence intensity, the numerical results showed good agreement in (1) the velocity profile downstream of the pipe expansion measured by particle image velocimetry (PIV) in this study, and (2) the reattachment length reported in the literature. Using this validated model, the numerical simulation of flow and component mixing was performed for the FPVS with an inlet flowrate corresponding to a Reynolds number of 2,400 to investigate the flow behavior and component mixing. Standard deviation of the mass fraction of component, referred to as absolute mixing index (AMI), was calculated to quantify the mixing of components, showing that the component mixing length determined by AMI is related to the reattachment length downstream of the expansion. Additionally, this study was able to identify the best location in the FPVS test facility to measure the velocity and concentration profies where multicomponent flow is well mixed.

15 GEOTHERMAL ENERGY↗

Venting temperature determines surface chemistry of magnetron sputtered TiN films

Surface properties of refractory ceramic transition metal nitride thin films grown by magnetron sputtering are essential for resistance towards oxidation necessary in all modern applications. Here, typically neglected factors, including exposure to residual process gases following the growth and the venting temperature T{sub v}, each affecting the surface chemistry, are addressed. It is demonstrated for the TiN model materials system that T{sub v} has a substantial effect on the composition and thickness-evolution of the reacted surface layer and should therefore be reported. The phenomena are also shown to have impact on the reliable surface characterization by x-ray photoelectron spectroscopy.

36 MATERIALS SCIENCE↗

Vented and sealed cookoff of powdered and pressed ε-CL-20

In this work, we have completed a series of vented and sealed cookoff experiments of the ε-polymorph of CL-20 in our Sandia Instrumented Thermal Ignition (SITI) apparatus using both powder and pressed pellets at nominal densities of 313 ± 8 kg/m 3 and 1030 ± 4 kg/m 3 , respectively. The boundary temperature of our aluminum confinement cylinder was ramped in 10 minutes from room temperature to a prescribed set-point temperature ranging between 448 nd 468 K and held at the set-point temperature until ignition. A universal cookoff model (UCM) has been calibrated using the ε-CL-20 SITI data to predict pressurization and thermal ignition of ε-CL-20. The ignition model was validated by using one-dimensional time-to-explosion (ODTX) ignition data from a different laboratory. We found that a thirtyfold increase in the reaction rates due to liquefaction at 520 K could explain the high temperature ODTX cookoff data. The model gives a plausible explanation of why melting is important in fast cookoff events involving CL-20. Our model also gives support to 520 K as the liquefaction point of CL-20, which has different values in the literature.

36 MATERIALS SCIENCE↗

Lithium-Ion Battery Vent Gas Tools

The spreadsheets and Python scripts are used to determine vent gas hazard metrics (i.e. flammability limits, flame speed, etc.). These scripts and spreadsheets use open source literature to determine these hazard metrics. SAND2020-12540 O Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Baird, Austin↗