Synthesis and characterization of CuInS{sub 2} nanostructure by ultrasonic-assisted method and different precursors

Graphical abstract: Display Omitted Highlights: ► CuInS{sub 2} nanoparticles were synthesized by ultrasonic assisted method. ► CuInS{sub 2} nanoparticles obtained after annealing at 350 °C for 1 h. ► The effect of some parameters including ultrasonic was investigated. -- Abstract: This paper reports on the synthesis of CuInS{sub 2} nanostructure via an ultrasonic assisted method by employing different sulfur source. Morphology, structure and composition of the obtained products were characterized by X-ray diffraction (XRD), energy dispersive X-ray analysis (EDX), scanning electron microscope (SEM), infrared (IR) spectrum, and photoluminescence (PL) spectroscopy. The effects of ultrasonic irradiation, power and time of irradiation, surfactant, and type of copper source were investigated.

36 MATERIALS SCIENCE↗

Illumination of Damage in Intact Rocks by Ultrasonic Transmission-Reflection and Digital Image Correlation

aboratory-scale experiments on intact rocks are critical to the development of physics-based fundamental understanding of various geophysical phenomena. In this work, the capability of ultrasonic wave transmission (T-mode) and reflection (R-mode) to monitor damage progression in uniaxially loaded prismatic intact rock specimens has been analyzed, as it is imperative to study the observations and document the capabilities of these techniques in a controlled environment. This study is novel in the sense that the R-mode linear ultrasonic testing (LUT) has been rarely employed in studying intact rock damage processes in a laboratory setting, with most of the studies utilizing a direct transmission (T-mode) approach or focusing on macroscopically fractured material. The two-dimensional digital image correlation (2-D DIC) full-field strain measurement approach was also used in-sync with the LUT monitoring to explicitly correlate the stress-induced damage in the specimens with the changes observed in the ultrasonic (T-mode and R-mode) signals. The results show that both the T-mode and R-mode LUT approaches are sensitive to detect the evolution of tensile and shear damage in the specimens, with the R-mode ultrasonic signals showing higher degree of sensitivity to the damage in the rocks, immediately following the initiation of damage in the rock volume.

58 GEOSCIENCES↗

Ultrasonic detection technology based on joint robot on composite component with complex surface

Some components have complex surface, such as the airplane wing and the shell of a pressure vessel etc. The quality of these components determines the reliability and safety of related equipment. Ultrasonic nondestructive detection is one of the main methods used for testing material defects at present. In order to improve the testing precision, the acoustic axis of the ultrasonic transducer should be consistent with the normal direction of the measured points. When we use joint robots, automatic ultrasonic scan along the component surface normal direction can be realized by motion trajectory planning and coordinate transformation etc. In order to express the defects accurately and truly, the robot position and the signal of the ultrasonic transducer should be synchronized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An approach to improving transporting velocity in the long-range ultrasonic transportation of micro-particles

In existing ultrasonic transportation methods, the long-range transportation of micro-particles is always realized in step-by-step way. Due to the substantial decrease of the driving force in each step, the transportation is lower-speed and stair-stepping. To improve the transporting velocity, a non-stepping ultrasonic transportation approach is proposed. By quantitatively analyzing the acoustic potential well, an optimal region is defined as the position, where the largest driving force is provided under the condition that the driving force is simultaneously the major component of an acoustic radiation force. To keep the micro-particle trapped in the optimal region during the whole transportation process, an approach of optimizing the phase-shifting velocity and phase-shifting step is adopted. Due to the stable and large driving force, the displacement of the micro-particle is an approximately linear function of time, instead of a stair-stepping function of time as in the existing step-by-step methods. An experimental setup is also developed to validate this approach. Long-range ultrasonic transportations of zirconium beads with high transporting velocity were realized. The experimental results demonstrated that this approach is an effective way to improve transporting velocity in the long-range ultrasonic transportation of micro-particles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic properties of micro-particles in ultrasonic transportation using phase-controllable standing waves

Ultrasonic manipulation has become an attractive method for surface-sensitive objects in micro-technology. Related phenomena, such as radiation force, multiple scattering, and acoustic streaming, have been widely studied. However, in current studies, the behavior of micro-particles in potential force fields is always analyzed in a quasi-static manner. We developed a dynamic model of a dilute micro-particle in the commonly used two-dimensional ultrasonic manipulation system to provide a systemic and quantitative analysis of the transient properties of particle movement. In this model, the acoustic streaming and hydrodynamic forces, omitted in previous work, were both considered. The trajectory of a spherical silica particle with different initial conditions was derived by numerically solving the established nonlinear differential integral equation system, which was then validated experimentally. The envelope of the experimental data on the x-axis showed good agreement with the theoretical calculation, and the greater influence on the y-axis of the deviation between the actual sound field and the ideal distribution employed in our dynamic model could account for the differences in displacement in that direction. Finally, the influence of particle size on its movement and the effect of acoustic streaming on calculating the hydrodynamic forces for an isolated particle with motion relative to the fluid were analyzed theoretically. It was found that the ultrasonic manipulation system will translate from an under-damped system to an over-damped system with a decrease in particle size and the micro-scale acoustic streaming velocity was negligible when calculating the hydrodynamic forces on the particle in the ultrasonic manipulation system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superparamagnetic iron oxide nanoparticles incorporated into silica nanoparticles by inelastic collision via ultrasonic field: Role of colloidal stability

Superparamagnetic iron oxide nanoparticles (SPION)/Silica composite nanoparticles were prepared by ultrasonically irradiating colloidal suspension of silica and SPION mixture. Both silica and SPION were synthesized independently via co-precipitation and sol-gel method, respectively. Their mixtures were sonicated at different pH between 3 and 5. Electrophoresis measurement and other physicochemical analyses of the products demonstrate that at lower pH SPION was found incorporated into the silica. However, at pH greater than 4, SPION was unstable and unable to withstand the turbulence flow and shock wave from the ultrasonic field. Results suggest that the formation of the SPION/silica composite nanoparticles is strongly related to the inelastic collision induced by ultrasonic irradiation. More so, the formation the composite nanoparticles via the ultrasonic field are dependent on the zeta potential and colloidal stability of the particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis mechanism and improved (100) oriented NaNbO{sub 3} templates by ultrasonication

The plate-like NaNbO{sub 3} (NN) templates with (100) preferential orientation was synthesized from bismuth layer structured ferroelectric Bi{sub 2.5}Na{sub 3.5}Nb{sub 5}O{sub 18} (BNN) precursor by topochemical microcrystal conversion (TMC) method. The large platelets of BNN were first obtained by molten salt synthesis at the 1125 °C with a salt-to oxide weight ratio 1.5: 1. The anisotropic NN templates were derived from BNN at the 975 °C with BNN/ Na{sub 2}CO{sub 3} molar ratio of 1:1.5. The NaNbO{sub 3} templates have an average length of ~ 10-14 µm. The NN templates retains their elemental constitutes of Na, Nb and O in stoichiometric proportion. The effect of ultrasonication on the orientation factor (F{sub h00}) of NN templates was understood by X-ray diffraction (XRD) and scanning electron microscopy (SEM) results. The degree of (100) orientation of as synthesized NN templates (~57%) was found to be increased (~89%) after ultrasonication. Moreover, the microstructure i.e. alignment / shape of as synthesized NN templates was changed from rectangular (110) orientation to square (100) orientation geometry after ultrasonication. Hence, ultrasonication is a cost effective approach to preparing the textured piezoelectric ceramics by the template grain growth technique using tape casting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Full-waveform inversion and least-squares reverse-time migration imaging of collimated ultrasonic-beam data for high-resolution wellbore integrity monitoring

Los Alamos National Laboratory (LANL) has recently developed an ultrasonic side-lobe suppressed Bessel collimated beam transducer for low-frequency imaging through highly attenuating materials. In this paper, we study the effectiveness of using such a collimated ultrasonic-beam transducer for imaging concrete heterogeneities outside borehole casing for high-resolution borehole imaging and wellbore integrity monitoring. We obtain detailed concrete heterogeneities including a low-velocity zone using ultrasound data acquired with a 3D imaging prototype and our recently developed full-waveform inversion and least-squares reverse-time migration methods. Full-waveform inversion fits synthetic ultrasonic waveforms with recorded waveforms to build a high-resolution velocity model. Least-squares reverse-time migration produces a high-resolution structural image showing material discontinuities. Finally, our results demonstrate that LANL's 3D imaging system with a collimated ultrasonic-beam transducer together with full-waveform inversion and least-squares reverse-time migration imaging has great potential for high-resolution single-well borehole imaging and non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Ultrasonic Measurements of Temperature Distribution in Extreme Environments: Results of Power Plant Testing

The most hardened insertion sensors do not perform reliably in extreme environmental conditions. We address this problem by developing an ultrasonic thermometry system for the measurements of segmental temperature distributions (MSTD) in solid materials and, specifically, across containments of energy conversion processes. The MSTD approach uses an echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features. In pulse-echo mode, these features produce a train of echoes in response to an external pulse of ultrasonic excitation created and acquired by a transducer located outside the extreme environment. The delays between the echoes encode the information on the temperature distribution in the corresponding segments of the ultrasonic propagation path, which we use to reconstruct an unknown temperature profile. This note describes the preliminary results and initial experience in applying the developed MSTD ultrasonic thermometry system to the measurements of temperatures in a utility-scale 500MW coal-fired boiler.

John, Mason↗

Novel Experimental Study of Fabric Drying Using Direct-Contact Ultrasonic Vibration

Here, fabric drying is an energy-intensive process, which generally involves blowing hot dry air across tumbling wet fabric to facilitate evaporation and moisture removal. Most of the energy supplied is used to overcome the enthalpy of vaporization for water. Although this process tends to be inefficient, it is fairly simple and forms the basis for the majority of existing clothes dryer technology today. To address the relatively low efficiency, a new method of drying called “direct contact ultrasonic fabric drying” is proposed. The process involves using high-frequency vibration introduced by piezoelectric transducers, which are in contact with wet fabric. The vibration is used to extract water droplets from the fabric mechanically. In this study, a total of 24 individual transducers are used in a module to dry a 142 cm 2 sized fabric. The performance characterization of this single module has enabled successful scale-up of the system to a midscale prototype dryer, which can be used to ultrasonically dry clothing-sized fabric (~750 cm 2 ). The first-generation ultrasonic fabric dryer fabricated uses as little as 17% of the energy needed by traditional evaporation-based drying techniques. In addition to experimental data, this paper presents the results of a kinetic and scaling analysis that provides some important insights into ultrasonic drying.

42 ENGINEERING↗

Implementation and validation of an ultrasonic tissue characterization technique for quantitative assessment of normal-tissue toxicity in radiation therapy

The goal of this study was to implement and validate a noninvasive, quantitative ultrasonic technique for accurate and reproducible measurement of normal-tissue toxicity in radiation therapy. The authors adapted an existing ultrasonic tissue characterization (UTC) technique that used a calibrated 1D spectrum based on region-of-interest analysis. They modified the calibration procedure by using a reference phantom instead of a planar reflector. This UTC method utilized ultrasonic radio-frequency echo signals to generate spectral parameters related to the physical properties (e.g., size, shape, and relative acoustic impedance) of tissue microstructures. Three spectral parameters were investigated for quantification of normal-tissue injury: Spectral slope, intercept, and midband fit. They conducted a tissue-mimicking phantom study to verify the reproducibility of UTC measurements and initiated a clinical study of radiation-induced breast-tissue toxicity. Spectral parameter values from measurements on two phantoms were reproducible within 1% of each other. Eleven postradiation breast-cancer patients were studied and significant differences between the irradiated and untreated (contralateral) breasts were observed for spectral intercept (p=0.003) and midband fit (p<0.001) but not for slope (p=0.14). In comparison to the untreated breast, the average difference in the spectral intercept was 2.99{+-}0.75 dB and the average difference in the midband fit was 3.99{+-}0.65 dB. The preliminary clinical study demonstrated the feasibility of using the quantitative ultrasonic method to evaluate normal-tissue toxicity in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-Based Ultrasonic SignalProcessing for the Nondestructive Evaluation of Additive Manufacturing Components

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detection of the part under investigation. A primary ingredient in UT besides the required precision robotic hardware for the acquisition of high quality measurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report, we discuss the basic steps in UT signal processing along with current and future capabilities that must be achieved in order to satisfy the critical demands created by the AM process. In its basic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques to extract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonic excitation from a physics-based perspective. Once developed, we briefly discuss the various choices of excitation signals and their tradeoffs. Next we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.” The underlying pre- and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data. Finally, we discuss some open problems in UT and suggest a much more sophisticated model-based approach expanding these revolutionary ideas and encompassing more realistic signal models that incorporate noise, jitter and other pertinent uncertainties into the processor.

36 MATERIALS SCIENCE↗

Development of an advanced ultrasonic phased array for the characterization of thick, reinforced concrete components (Final Scientific/Technical Report)

There are no nondestructive evaluation (NDE) tools capable of characterizing microscale damage throughout the thickness of concrete components, due to the multiphase, heterogeneous and multiscale nature of concrete. Ultrasound is only scattered by features at the same length scale, or smaller, than the wavelength of a wave’s dominant frequency. Successful imaging of microscale damage using ultrasound requires that the ultrasonic wavelength be on the order of a few millimeters (or smaller), yet the heterogeneous microstructure of concrete, with its fine and coarse aggregates, is on this same (and higher) micrometer/millimeter length scale, causing excessive ultrasonic wave scattering even in “good” concrete. The proposed solution applies non-collinear wave mixing to spatially image microscale damage, while still maintaining penetration through thick concrete components. This microscale imaging is possible by combining nonlinear wave mixing, with advanced phased array hardware and software to develop a breakthrough tool that will bring revolutionary changes in NDE of concrete infrastructure in terms of image resolution and depth of penetration. This work uses non-collinear wave mixing which exploits the physics that material nonlinearities such as microscale damage, cause interactions between two intersecting ultrasonic waves due to cross-mixing, which can lead to the generation of a third wave with a frequency and wave number of the sum or difference of the incident waves. The concrete material volume at this mixing point is characterized/imaged. This project delivered a single-sided nonlinear ultrasonic phased array imaging device, that can image microscale damage (microcracks of 100 micrometers) through a 0.5 m thick concrete component and assessed the commercial feasibility of such arrays for improved crack detection.

42 ENGINEERING↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

36 MATERIALS SCIENCE↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Study of the Effects of Ultrasonic Waves on the Reproductive Integrity of Mammalian Cells Cultured in Vitro

The effects of monochromatic ultrasonic waves of 0.1, 0.5, 1.0, 2.0 and, 3.3 MHz frequency on the colony-forming ability of mammalian cells (M3-1,V79, Chang's and T-1) cultured in vitro have been studied to determine the nature of the action of ultrasonic energy on biological systems at the cellular level. The combined effect of ultrasound and X-rays has also been studied. It is concluded: (1) Ultrasonic irradiation causes both lethal and sublethal damage. (2) There is a threshold dose rate for lethal effects. (3) The effectiveness of ultrasonic waves in causing cell death probably depends on the frequency and the amplitude of the waves for a given cell line, indicating a possible resonance phenomenon.

Martins, B. I.↗

Semiconductor measurement technology: Microelectronic ultrasonic bonding

Information for making high quality ultrasonic wire bonds is presented as well as data to provide a basic understanding of the ultrasonic systems used. The work emphasizes problems and methods of solving them. The required measurement equipment is first introduced. This is followed by procedures and techniques used in setting up a bonding machine, and then various machine- or operator-induced reliability problems are discussed. The characterization of the ultrasonic system and its problems are followed by in-process bonding studies and work on the ultrasonic bonding (welding) mechanism. The report concludes with a discussion of various effects of bond geometry and wire metallurgical characteristics. Where appropriate, the latest, most accurate value of a particular measurement has been substituted for an earlier reported one.

Harman, G. G.↗

Ultrasonic bone densitometer

A device, for measuring the density of a bone structure so as to monitor the calcium content, is described. A pair of opposed spaced ultrasonic transducers are held within a clamping apparatus closely adjacent the bone being analyzed. These ultrasonic transducers incude piezoelectric crystals shaped to direct signals through the bone encompassed in the heel and finger of the subject being tested. A pulse generator is coupled to one of the transducers and generates an electric pulse for causing the transducers to generate an ultrasonic sound wave which is directed through the bone structure to the other transducer. An electric circuit, including an amplifier and a bandpass filter couples the signals from the receiver transducer back to the pulse generator for retriggering the pulse generator at a frequency proportional to the duration that the ultrasonic wave takes to travel through the bone structure being examined.

Hoop, J. M.↗