Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transition Edge Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The SPT-3G+ Experiment on the South Pole Telescope

Observations of the cosmic microwave background (CMB) offer an unparalleled opportunity to advance our understanding of fundamental physics. SPT-3G+ is an upgraded receiver for the arcminute-resolution South Pole Telescope (SPT) that plans to deploy in late 2028. SPT-3G+ will increase the CMB mapping speed of SPT by nearly an order of magnitude over the currently installed SPT-3G receiver. SPT-3G+ will have ~24,000 transition-edge sensor (TES) bolometers in two frequency bands with center frequencies at 95 GHz and 150 GHz that will be read out with microwave multiplexing. SPT-3G+ will measure the CMB lensing spectrum and galaxy clusters to constrain the growth of structure, dark matter, and dark energy. SPT-3G+ will also reach critical thresholds on inflationary constraints by combining data with BICEP/Keck, forming the South Pole Observatory (SPO). BICEP/Keck has deep degree-angular scale measurements but is currently delensing-limited, while SPT-3G+ will provide deep lensing measurements. Forecasts show that SPO will reach an uncertainty on the tensor-to-scalar ratio $r$ of $\sigma(r) \sim 1.2\times 10^{-3}$ by 2034. A detection at these levels would provide evidence of inflation and probe new physics at grand unified theory energy scales, while no detection would exclude large classes of models and shift the scientific paradigm describing the early universe. I will give an overview of SPT-3G+ including its design and current status.

Simon, Sara M. [Fermilab] (ORCID:0009000006683584)↗

The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection

The Cryogenic Dark Matter Search (CDMS) is searching for Weakly Interacting Massive Particles (WIMPs) with cryogenic particle detectors. These detectors have the ability to discriminate between nuclear recoil candidate and electron recoil background events by collecting both phonon and ionization energy from recoils in the detector crystals. The CDMS-II experiment has completed analysis of the first data runs with 30 semiconductor detectors at the Soudan Underground Laboratory, resulting in a world leading WIMP-nucleon spin-independent cross section limit for WIMP masses above 44 GeV/c 2 . As CDMS aims to achieve greater WIMP sensitivity, it is necessary to increase the detector mass and discrimination between signal and background events. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices has shown that hydrogen passivation of the amorphous silicon blocking layer worsens surface trapping. Additional data has shown that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors causes a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and in situ at the experimental site have provided methods to optimize the neutralization process and monitor running conditions to maintain full ionization collection. This work details my contribution to the 5-tower data taking, monitoring, and analysis effort as well as the SuperCDMS detector development with the focus on monitoring and improving ionization collection in the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

Abstract We report on the design and performance of the B icep3 instrument and its first three-year data set collected from 2016 to 2018. B icep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. B icep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μ K CMB s and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μ K arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μ K arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

The EBEX Balloon-borne Experiment—Optics, Receiver, and Polarimetry

The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric method and discuss their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make effective use of limited mass and space, we created a 115 cm 2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0$^{°}_{.}$1. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.

polarization↗

The EBEX Balloon-borne Experiment—Gondola, Attitude Control, and Control Software

The E and B Experiment (EBEX) was a long-duration balloon-borne instrument created to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We report on the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We demonstrate flight performance data reflecting faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.

polarization↗

The Simons Observatory: Design, Integration, and Testing of the Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of σ(r) = 0.002, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35° field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and <0.1 K focal plane that holds >12,000 transition edge sensor detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Furthermore we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

Astronomical instrumentation↗

Ultra-high-resolution alpha spectrometry for nuclear forensics and safeguards applications

We will present our work on the development of ultra-high-resolution detectors for alpha particle spectrometry. These detectors, based on superconducting transition-edge sensors, offer energy resolution that is five to ten times better than conventional silicon detectors. Using these microcalorimeter detectors, the isotopic composition of mixed-actinide samples can be determined rapidly without the need for actinide separation chemistry to isolate each element, or mass spectrometry to separate isotopic signatures that can not be resolved using traditional alpha spectrometry (e.g. Pu-239/Pu-240, or Pu-238/Am-241). This paper will cover the detector and measurement system, actinide source preparation, and the quantitative isotopic analysis of a number of forensics- and safeguards-relevant radioactive sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SPIDER: CMB Polarimetry from the Edge of Space

SPIDER is a balloon-borne instrument designed to map the polarization of the millimeter-wave sky at large angular scales. SPIDER targets the B-mode signature of primordial gravitational waves in the cosmic microwave background (CMB), with a focus on mapping a large sky area with high fidelity at multiple frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015 deployed a total of 2400 antenna-coupled Transition Edge Sensors (TESs) at 90 GHz and 150 GHz. In this work we review the design and in-flight performance of the SPIDER instrument, with a particular focus on the measured performance of the detectors and instrument in a space-like loading and radiation environment. SPIDER's second flight in December 2018 will incorporate payload upgrades and new receivers to map the sky at 285 GHz, providing valuable information for cleaning polarized dust emission from CMB maps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Physics with the Cosmic Microwave Background with SPT-3G

The cosmic microwave background (CMB) encodes information about the content and evolution of the universe. The presence of light, weakly interacting particles impacts the expansion history of the early universe, which alters the temperature and polarization anisotropies of the CMB. In this way, current measurements of the CMB place interesting constraints on the neutrino energy density and mass, as well as on the abundance of other possible light relativistic particle species. We present the status of an on-going 1500 sq. deg. survey with the SPT-3G receiver, a new mm-wavelength camera on the 10-m diameter South Pole Telescope (SPT). The SPT-3G camera consists of 16,000 superconducting transition edge sensors, a 10x increase over the previous generation camera, which allows it to map the CMB with an unprecedented combination of sensitivity and angular resolution. We highlight projected constraints on the abundance of sterile neutrinos and the sum of the neutrino masses for the SPT-3G survey, which could help determine the neutrino mass hierarchy.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

A Liquid-Cryogen-Free Cryostat for Ultrahigh Resolution Gamma-Ray Spectrometers

We are developing ultra-high energy resolution gamma-ray detectors based on superconducting transition edge sensors (TESs) for nuclear non-proliferation and fundamental science applications. They use bulk tin absorbers attached to molybdenum-copper multilayer TESs, and have achieved an energy resolution between 50 and 90 eV FWHM for gamma-ray energies below 122 keV. For increased user-friendliness, we have built a cryostat that attains the required detector operating temperature of 0.1 K at the push of a button without the use of cryogenic liquids. It uses a two-stage mechanical pulse tube refrigerator for precooling to {approx}3 K, and a two-stage adiabatic demagnetization refrigerator for cooling to the base temperature. The cryostat is fully automated, attains a base temperature below 30 mK without the use of cryogenic liquids, and has a hold time of {approx}2 days at 0.1 K between 1-hour demagnetization cycles. Here we discuss the performance of the cryostat for operation in a Gamma-spectrometer with 112-pixel arrays of superconducting TES detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Sunyaev-Zel'Dovich effect observations of the bullet cluster (1E 0657-56) with APEX-SZ

We present observations of the Sunyaev-Zel'dovich effect (SZE) in the Bullet cluster (1E 0657-56) using the APEX-SZ instrument at 150 GHz with a resolution of 1'. The main results are maps of the SZE in this massive, merging galaxy cluster. The cluster is detected with 23 sigma significance within the central 1' radius of the source position. The SZE map has a broadly similar morphology to that in existing X-ray maps of this system, and we find no evidence for significant contamination of the SZE emission by radio or IR sources. In order to make simple quantitative comparisons with cluster gas models derived from X-ray observations, we fit our data to an isothermal elliptical beta model, despite the inadequacy of such a model for this complex merging system. With an X-ray derived prior on the power-law index, beta = 1.04+0.16-0.10, we find a core radius rc = 142" +- 18", an axial ratio of 0.889 +- 0.072, and a central temperature decrement of -771 +- 71 muKCMB, including a +-5.5percent flux calibration uncertainty. Combining the APEX-SZ map with a map of projected electron surface density from Chandra X-ray observations, we determine the mass-weighted temperature of the cluster gas to be Tmg = 10.8 +- 0.9 keV, significantly lower than some previously reported X-ray spectroscopic temperatures. Under the assumption of an isothermal cluster gas distribution in hydrostatic equilibrium, we compute the gas mass fraction for prolate and oblate spheroidal geometries and find it to be consistent with previous results from X-ray and weak-lensing observations. This work is the first result from the APEX-SZ experiment and represents the first reported scientific result from observations with a large array of multiplexed superconducting transition-edge sensor bolometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and fabrication of Argonne/KICP detectors for CMB polarization.

We present the design, microfabrication and assembly of dual-polarization absorber-coupled Transition Edge Sensor (TES) bolometer detectors for cosmic microwave background B-mode polarization studies. The device consists of two separate dies incorporating suspended silicon nitride membranes within silicon frames, carefully aligned perpendicularly and fixtured face-to-face. Polarization sensitivity around 95 GHz is provided by a single dipole-like absorber element; we briefly analyze this absorber-in-waveguide configuration in closed form using the EMF method. Proximity effect Mo/Au bilayers provide control of the TES critical temperature between 400 mK and 600 mK, with a normal resistance R{sub n} {approx} 1{Omega}. DC magnetron sputtering, wet etching, and liftoff were employed for TES fabrication. Optimization of the superconducting Mo thin film utilized independent RF bias applied to the substrate during deposition in a confocal geometry. This technique allows outstanding thin film uniformity and stress to be achieved simultaneously over a 4-inch wafer surface, leading to excellent superconducting properties. Device thermal conductance in the range from 25-250pW/K was achieved using suspended silicon nitride membranes 1 micron thick. The value of the thermal conductance depends very strongly upon the surface roughness, and therefore in turn upon the treatment of the silicon nitride material during fabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical properties of Argonne/KICP TES bolometers for CMB polarimetry.

We present optical data on prototype polarization sensitive Argonne/KICP detectors fabricated at Argonne National Labs which are designed to be installed on the South Pole Telescope and used to measure the polarization of the Cosmic Microwave Background radiation. The detectors are Mo/Au transition edge sensors (TES) suspended on silicon nitride, with radiation coupled to the TES using a gold bar absorber. Two stacked detectors with bars in orthogonal directions will be used to measure both polarizations. We discuss measurements of the optical bandpass, time constants and cross-polarization of the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗