SEARCH · Engineering Papers
Results for “Testing and Performance”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Intrusion Simulation Tools and Performance Testing Techniques.
Abstract not provided.
Using LANL Applications for Performance Testing of Cielo Red Sky ...
Abstract not provided.
Performance Tests of Physical Security Technologies How to Test Outline.
Abstract not provided.
Performance Testing of Physical Protection Equipment and Systems.
Abstract not provided.
Solid State Streak Camera Prototype Electronic Performance Testing and Improvements to Dynamic Range
Explore the source record for details and available documents.
Performance Testing and Lessons Learned from the Development of a Prototype 100 kWt Moving Packed-Bed Particle-to-sCO2 Heat Exchanger.
Abstract not provided.
Performance testing of commercially available tools for logo and text detection.
Abstract not provided.
Performance Testing of Cyber Incident Response at Nuclear Power Plant Operators.
Abstract not provided.
High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector
High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)
Development of a New Clearance Monitor for Exemption of NPP Radioactive Wastes and its Performance Test - 17200
In nuclear power plants, it is common practice to clear radioactive wastes for free release by using clearance monitor with plastic scintillation detectors so as to reduce disposal costs. These monitors are possible in part thanks to the excellent detection levels achievable with high energy and high yield photons emitted from contaminants such as Cs-137 and Co-60. However, it is difficult for the monitors to separate Naturally Occurring Radioactive Materials (NORM) from the radioactive wastes because the plastic scintillation detectors have poor resolution compared to NaI or HPGe detectors. KHNP has developed a new clearance monitor for determining whether or not the radioactivity level of metal scraps satisfies regulatory criteria. The monitor is composed of 12 large area plastic scintillation detectors and 3 NaI scintillation detectors. The measuring chamber is surrounded by a 5 cm-thick lead shield with chamber dimensions of 1.5 m x 1.0 m x 1.0 m. Its algorithm has a function of measuring total gamma activity while analyzing gamma nuclides and identifying 27 hotspots in radioactive wastes. The detection limit of this system, according to the MCNP simulation, was determined to be about 45 Bq for Co-60 and 78 Bq for Cs-137 with the condition of an empty chamber and measuring time of 1 minute. We evaluated the self - shielding effect of waste for background correction factor and waste height (volume in the chamber) correction factor. We also tested its MDA, location determination of hot-spots, temperature compensation function and convenience of operation. In the future, we will plan to install it at a nuclear site for more tests including evaluating its durability. (authors)
Experimental Methods for the Performance Test of Environment-Assisted Cracking (EAC) in Nuclear Industry and Examples through NSUF
Environmentally assisted cracking (EAC) is a critical failure mode in nuclear reactor environments, where materials are exposed to high temperatures, radiation, and corrosive media. Specific EAC studies in nuclear environments include stress corrosion cracking in primary water chemistry, irradiation-assisted stress corrosion cracking (IASCC) under neutron exposure, and hydrogen induced cracking (HIC) in reactor pressure vessels. The experimental methodologies of EAC include slow strain rate testing (SSRT), constant load, and cyclic loading techniques, conducted in autoclaves designed to simulate the reactor’s operational environments. This paper highlights several experimental case studies, especially on IASCC, conducted within the Nuclear Science User Facilities (NSUF).
Methodologies and Tools for Testing the Performance of Security Equipment [Slides]
The presentation outline includes these items: physical protection systems definitions/terms, developing security systems performance tests, testing methodologies, system testing process, challenges, and discussion.
Durable, Ultra-Thin Diaphragms for Liquid Alkaline Water Electrolysis
W. L. Gore & Associates assembled a world class team (De Nora Tech, LLC; New York University; and thyssenkrupp nucera) to develop durable, ultra-low resistance diaphragms that dramatically improve system efficiency, dynamic response, and operational flexibility. To enable the use of ultra-thin diaphragms, an optimized electrode package was chosen as part of an electrode down select study. Ultra-thin diaphragms based on microporous polymer scaffolds imbibed with zirconia nanoparticles were developed and tested. Performance and durability on par with incumbent materials was demonstrated. A transparent electrolyzer to directly observe in-situ diaphragm-bubble interactions was designed and built, and simultaneous optical and electrochemical performance tests were performed. A Pressurized Alkaline Water Electrolysis (PAWE) single cell test station was designed to support advanced R&D in high-pressure electrolysis, particularly for evaluating novel electrode and separator configurations under elevated temperature and pressure operating conditions. Due to early project termination, the original scope could not be fully achieved.
Development Of A Compact Photo-injector With RF-focusing Lens For Short Pulse Electron Source Application
For development of compact ultrafast electron source system, we are currently designing a short-pulse RF-gun with RF focusing structure by means of a series of comprehensive modeling analysis processes. EM design of a 2.5 cell resonant cavity with input coupler, acceleration dynamics of photo-emitted electron bunch, EM design of RF-lens with input coupler, and phasespace analysis of focused electron bunch are systematically examined with multi-physics simulators. All the features of the 2.856 GHz cavity geometry were precisely engineered for acceleration energies ranging from 100 keV to 500 keV (safety limited) to be powered by our 5 MW S-band klystron. The klystron (Thales TH2163) and modulator system (ScandiNova K1 turnkey system) were successfully installed and tested. Performance tests of the klystron system show peak output power > 5 MW, as per operation specifications. At the quasi-relativistic energies, the electron source is capable of generating 100fC -- 1 pC electron bunch with pulse duration close to 30 fs -- 1 ps and transverse size of a few hundred microns. PIC simulations have shown that the electron bunch undergoes fast RF acceleration, rapidly reaching the desired energies, which can be controlled by tuning RF injection phase and input driving power. It has been shown that it is possible to also focus/compress the bunch longitudinally using a RF-lens, which would allow us to control the temporal resolution of the system as well. While our primary analysis has been performed on a 2.5 cell design, we are also looking into half-cell (single cavity) design that is expected to provide the same range of beam energy with a simple configuration.