Flexural Fatigue Testing and Qualification of Hybrid PAN-pitch Composite Materials with High Through-Thickness Thermal Conductivity
Carbon-fiber-reinforced polymers (CFRPs) considered for motor components within future electric vertical takeoff and landing (eVTOL) vehicles require not only a high strength-to-weight ratio but also a high through-thickness thermal conductivity (TC) to dissipate heat. Previously, CFRPs incorporating pitch CF interleaves demonstrated an increased through-thickness TC relative to the baseline composite, but the effect on flexural fatigue life was not evaluated. For this work, T700S/TC275–1 braided carbon fiber/epoxy prepreg baseline (no interleave), YSH–60A pitch interleave, and YS–80A pitch interleave configurations were tested for fatigue life. A combination of ASTM International Standards D7264 and D3479 were used to develop a reliable testing method. An Instron® (Illinois Tool Works Inc.) 8501 servohydraulic system with a fatigue test fixture was set up with a 16:1 span:thickness ratio, load ratio R set to 0.1, and frequency of 4 Hz. High-cycle fatigue testing was completed, and it was found that YSH–60A interleave performed slightly better than YS–80A below 100,000 cycles but showed no differences above 100,000 cycles. In all cases, the baseline CFRP had superior fatigue life performance both in terms of stress handled and total cycles to failure. These fatigue testing data will inform future use of hybrid CFRP materials by highlighting the tradeoff between increased through-thickness TC and fatigue life. Testing guidelines, equipment, and parameters for static and fatigue tests were successfully outlined for CFRPs.