Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Atmospheric temperature measurements, using Raman lidar

The Raman-shifted return of a lidar system had been used to make atmospheric temperature measurements. The measurements were made along a horizontal path at temperatures ranging from -30 to 30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the rotational Raman spectrum, which were simultaneously sampled from a preset range. These tests verified that the theoretical predictions formulated in the design of the system were adequate. Measurements were made to an accuracy of + or - 4 C with 1-minute temporal resolution.

Salzman, J. A.↗

Apparatus Would Measure Temperatures Of Ball Bearings

Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

Gibson, John C.↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Calculation of atmospheric loss from microwave radiometric noise temperature measurements

Microwave propagation loss in the atmosphere can be inferred from microwave radiometric noise temperature measurements. The relevant equations are given and a derivation and calculation is made assuming various physical models. Comparison is made with the commonly used lumped element atmospheric model (isothermal and uniform loss) and the model with linear temperature and exponential loss distributions. The results are useful for estimating the integral inversion differences due to the model selection. This indicates that the commonly used lumped element atmospheric model is a very good approximation with judicious choice of the effective physical temperature. For the worst case comparison, the lumped element model agrees with the variable parameter model within 0.2 dB up to a propagation loss of 3 dB.

Stelzried, C.↗

Melting temperature measurement of refractory oxide ceramics as a function of oxygen fugacity using containerless methods

An aerodynamic conical nozzle levitator (CNL) has been used to measure the melting temperatures of refractory ceramics. The well-established method of cooling traces has been adapted to allow measurements for air-sensitive samples using a controlled atmosphere, where the oxygen partial pressure can be adjusted and monitored in real time. In this study, we explain the details of a system that we developed for use at the Spallation Neutron Source (Oak Ridge National Laboratory). Measurements of the melting behavior of (Fe,Cr,Al) 3 O 4 spinels were made between log (PO 2 (atm)) of -0.7 and -5. The melting temperature of hercynite is found to be oxygen potential dependent, ranging between 1692 and 1767°C at log (PO 2 ) values from -4.42 to -0.70.

36 MATERIALS SCIENCE↗

Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures

The purpose of this study was to determine if intestinal temperature (Tin) might be in acceptable alternative to esophageal (Tes) and rectal temperature (Trec) to assess thermoregulation during supine exercise. We hypothesized that Tin would have values similar to Tes and a response time similar to Trec, but the rate of temperature change across time would not be different between measurement sites. Seven subjects completed a continuous supine protocol of 20 min of rest, 20 min of cycle exercise at 40% peak oxygen consumption (VO2pk), 20 min of cycle exercise at 65% V02pk, and 20 min of recovery. Tes, Trec, and Tin were recorded each min throughout the test. Temperatures were not different after 20 min of rest, but Trec was less than the Tes and Tin at the end of the 40% and 65% VO2pk stages. After 20 min of recovery, Tes was less than either Trec or Tin, which were not different from each other. Time to threshold for increased temperature from rest was greater for Trec than Tes but not different from Tin. Time to reach peak temperature was greater for Tin and Trec than Tes. Similarly, time to a decrease in temperature after exercise was greater for Trec than Tes, but not different from Tin. The rate of temperature change from threshold to the end of the 40% VO2pk stage was not different between measurement sites. However, the rate of change during recovery was more negative for Tes than Tin and Trec, which were different from each other. Measurement of Tin may he an acceptable alternative to Tes and Trec with an understanding of its limitations.

Lee, Stuart M. C.↗

How close are ground-based Fabry-Perot thermospheric wind and temperature measurements to exospheric values? A simulation study

A computer simulation model of the measurement process for a ground-based Fabry-Perot interferometer (FPI) has been developed and used to study how variations of wind and temperature along the instrument line-of-sight affect the Doppler shift and width of the observed nightglow O(1D) emission line at high spectral resolution. Ground-based-derived temperatures in the nighttime sector of the winter hemisphere are found to give values that are representative of the peak O(1D) emission altitude. However, when the vertical temperature gradients are large, the ground-based FPI temperature measurement may differ by as much as about 12 percent from the temperature at the peak emission height. Simulations of the FPI measurement of nighttime thermospheric temperatures show that ground-based-derived temperatures may be lower by about 10 percent than the corresponding exospheric temperatures in the winter hemisphere and by about 15 percent in the summer hemisphere.

Mccormac, F. G.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

NASA's Turbulent Heat Flux (THX) task under the Transformational Tools & Technologies project is focused on acquiring benchmark temperature and velocity data in turbulent shear layers for validation of computational fluid dynamics (CFD) codes. Standard CFD turbulence models lack the ability to accurately calculate a number of fundamental flow phenomena, including the turbulent transport of heat. In nearly all production class Reynolds-averaged Navier-Stokes (RANS) CFD codes, a gradient-diffusion approximation is used whereby a constant turbulent Prantdl number, Prt, is used to relate an eddy viscosity calculated for the momentum terms, to the turbulent heat flux terms. The default in most CFD codes is Prt = 0.9, however this is not representative of all flows. As discussed in Yoder et al. (2015) and Reynolds (1974), Prt = 0.7 is felt to be more appropriate for jets. Recent work, as discussed in Yoder (2016a), has explored more complex formulations including variable turbulent Prantdl number models. PARTICLE IMAGE VELOCIMETRY; TEMPERATURE MEASURING INSTRUMENTS; FILM COOLING; HIGH TEMPERATURE GASES; COMPUTATIONAL FLUID DYNAMICS; PREDICTION ANALYSIS TECHNIQUES; TURBULENCE MODELS; RAMAN SPECTRA; VELOCITY; MACH NUMBER; GAS TURBINE ENGINES; NOZZLE FLOW; THERMOCOUPLES; LASER INDUCED FLUORESCENCE; COOLING FLOWS (ASTROPHYSICS); RAMAN SPECTROSCOPY; HEAT FLUX

Wernet, Mark P.↗

iButton and Tinytag snow/ground interface temperature measurements at Teller 27 and Kougarok 64 from 2022-2023, Seward Peninsula, Alaska

Snow/ground interface temperature measurements were collected at the NGEE Arctic Teller Road Site at mile marker 27 (TL_MM27) and at the Kougarok Road Site at mile marker 64 (KG_MM64) on the Seward Peninsula, Alaska. Data were collected between October 1, 2022 to September 18, 2023 using iButton Link DS1921G-F5# Thermochron miniature temperature sensors (https://www.ibuttonlink.com/products/ds1921g) and Tinytag TGP-4017 internal sensors (https://www.micronmeters.com/product/tgp-4017-internal-sensor-40-to-85-c-40-f-to-185-f) deployed across the Kougarok and Teller sites. These sensors are a cost-efficient way to collect snowpack temperatures at a higher spatial resolution than what is normally achieved. iButton data were collected every 4 hours, while Tinytag data were collected every 30 minutes. In total, data were collected from 196 iButtons and 26 Tinytags. This dataset contains four *.csv files of near-ground surface temperatures at various locations throughout each study site and two *.kml files of sensor locations. Data were collected throughout the snow cover season so that snowpack characteristics could be derived using the temperature data. Sensors were placed both inside and outside of vegetation to better capture the spatial variability of snow properties across each domain.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic) was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Instantaneous 2D Velocity and Temperature Measurements in High Speed Flows Based on Spectrally Resolved Molecular Rayleigh Scattering

A Rayleigh scattering diagnostic for high speed flows is described for the simultaneous, instantaneous measurement of gas temperature and velocity at a number (up to about one hundred) of locations in a plane illuminated by an injection-seeded, frequency doubled Nd:YAG laser. Molecular Rayleigh scattered light is collected and passed through a planar mirror Fabry-Perot interferometer. The resulting image is analyzed to determine the gas temperature and bulk velocity at each of the regions. The Cramer Rao lower bound for measurement uncertainty is calculated. Experimental data is presented for a free jet and for preliminary measurements in the Lewis 4 inch by 10 inch supersonic wind tunnel.

Seasholtz, Richard G.↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 ?m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

Nanoscale and Element-Specific Lattice Temperature Measurements Using Core-Loss Electron Energy-Loss Spectroscopy

Measuring nanoscale local temperatures, particularly in vertically integrated and multicomponent systems, remains challenging. Spectroscopic techniques like X-ray absorption and core-loss electron energy-loss spectroscopy (EELS) are sensitive to lattice temperature, but understanding thermal effects is nontrivial. This work explores the potential for nanoscale and element-specific core-loss thermometry by comparing the Si L2,3 edge’s temperature- dependent redshift against plasmon energy expansion thermometry (PEET) in a scanning TEM. Using density functional theory (DFT), time-dependent DFT, and the Bethe−Salpeter equation, we ab initio model both the Si L 2,3 and plasmon redshift. We find that the core-loss redshift occurs due to bandgap reduction from electron−phonon renormalization. Our results indicate that despite lower core-loss signal intensity compared to plasmon features, core-loss thermometry has key advantages and can be more accurate through standard spectral denoising. Specifically, we show that the Varshni equation easily interprets the core-loss redshift for semiconductors, which avoids plasmon spectral convolution for PEET in complex junctions and interfaces. We also find that core-loss thermometry is more accurate than PEET at modeling thermal lattice expansion in semiconductors, unless the specimen’s temperature-dependent dielectric properties are fully characterized. Furthermore, core-loss thermometry has the potential to measure nanoscale heating in multicomponent materials and stacked interfaces with elemental specificity at length scales smaller than the plasmon’s wave function.

Bethe–Salpeter equation↗

Temperature Measurement Comparability in the Presence of a Stratospheric Warming

The MaCWAVE (Mountain and Convective Waves Ascending Vertically) campaign that took place from ESRANGE, Sweden in January 2003 provided extremely useful inflatable falling sphere temperature profiles. The time distribution of the measurements allowed us to portray changes occurring in the atmospheric structure during a stratospheric warming and also permitted us to examine the comparability of in situ and remotely measured temperatures, especially data from SABER and AIRS and the U, Bonn Lidar also operating at ESRANGE. Sphere and retrieved temperature profiles followed changes occurring in the stratospheric warming event, e.g. temperature increase, decrease, and the recovery. It is unavoidable that the remote source measurements were not always coincidental in time or space with the falling sphere measurements. However, we illustrate how well both types of measurements represent the polar winter atmosphere during this STRATWARM event. Our examination of these data indicates that they provide reasonably similar temperature profiles. We also identify whether differences between the two types of measurements were within acceptable accuracy bounds,

Schmidlin, Francis J.↗