Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Atom probe tomography of segregation at grain boundaries and gas bubbles in neutron irradiated U-10 wt% Mo fuel

During neutron irradiation to fission densities > 5.2 × 10 21 fiss/cm 3 , Xe agglomerates forming gas bubbles of varying size within the U-Mo fuel matrix. Herein, segregation of fission products to Xe bubbles and grain boundaries (GB) were studied using atom probe tomography (APT). Segregation behavior was found to vary among GBs, small bubbles (<10 nm), and larger bubbles (>10 nm). Solid fission products were enriched at GBs and larger bubbles, but not at small bubbles. Finally, a denuded zone was identified adjacent to a > 10 nm Xe gas bubble and a GB.

36 MATERIALS SCIENCE↗

Resolving three-dimensional nanoscale heterogeneities in lithium metal batteries with cryoelectron tomography

Current direct observation of sensitive battery materials and interfaces primarily relies on two-dimensional (2D) imaging, leaving out their three-dimensional (3D) relationship. Here, in this study, we used cryoelectron tomography (cryo-ET) to visualize the lithium metal anode in 3D at nanometer resolution and cryoelectron microscopy (cryo-EM) to reveal atomic details in local regions. We imaged both freshly prepared and calendar-aged Li metal anodes to reveal the development of LiH in Li dendrites and the Li-LiH interface, as well as the development of the solid-electrolyte interphase (SEI). Using a convolutional neural network-based technique, the 3D arrangement of Li metal, along with nanoscale LiH and Cu heterogeneities in dendrites, was visualized and annotated. In longer-term calendar aging, we observed more substantial LiH growth accompanied by extended SEI growth. Our results show that the growth of LiH and the extended SEI during battery calendar aging are temporally and spatially separate processes.

LiH↗

Resolving protein-mineral interfacial interactions during in vitro mineralization by atom probe tomography

Organic macromolecules exert remarkable control over the nucleation and growth of inorganic crystallites during (bio)mineralization, as exemplified during enamel formation where the protein amelogenin regulates the formation of hydroxyapatite (HAP). However, it is poorly understood how fundamental processes at the organic-inorganic interface, such as protein adsorption and/or incorporation into minerals, regulates nucleation and crystal growth due to technical challenges in observing and characterizing mineral-bound organics at high-resolution. Here, atom probe tomography techniques were developed and applied to characterize amelogenin-mineralized HAP particles in vitro, revealing distinct organic-inorganic interfacial structures and processes at the nanoscale. Specifically, visualization of amelogenin across the mineralized particulate demonstrates protein can become entrapped during HAP crystal aggregation and fusion. Identification of protein signatures and structural interpretations were further supported by standards analyses, i.e., defined HAP surfaces with and without amelogenin adsorbed. These findings represent a significant advance in the characterization of interfacial structures and, more so, interpretation of fundamental organic-inorganic processes and mechanisms influencing crystal growth. Ultimately, this approach can be broadly applied to inform how potentially unique and diverse organic-inorganic interactions at different stages regulates the growth and evolution of various biominerals.

36 MATERIALS SCIENCE↗

Micro X-ray computed tomography examination of mini plate fuel with hot isostatic pressed aluminum cladding

In order to minimize proliferation risks and improve security of nuclear material, the United States high performance research and test reactors (USHPRR) program is tasked with converting nuclear reactors that are fueled with highly enriched uranium (HEU) fuels to operate with low-enriched uranium (LEU) nuclear fuels. One favorable LEU fuel configuration is plate fuel with a metallic uranium-molybdenum foil clad within an aluminum alloy (AA 6061). In this fuel, the aluminum cladding is bonded with a hot isostatic pressing (HIP) method to seal the cladding around the fuel meat. However, the HIP process parameters influence the cladding performance, as a defective or incomplete bond can cause a pathway for corrosion. Micro X-ray computed tomography (XCT), a nondestructive technique that provides volumetric imaging, can be applied to inspect fuel plate cladding at the engineering scale. In this work, XCT methodology was developed and successfully utilized to not only observe the bond line of unirradiated mini fuel plates, but to also identify subsurface abnormalities in the plates’ cladding. Importantly, in future work, this technique could be applied to fuel plates, pre- and post-irradiation, to quantify irradiation effects on cladding defects and bond line integrity.

36 MATERIALS SCIENCE↗

Anisotropy evolution of elastomeric foams during uniaxial compression measured via in-situ X-ray computed tomography

We have characterized the three-dimensional evolution of microstructural anisotropy of a family of elastomeric foams during uniaxial compression via in-situ X-ray computed tomography. Flexible polyurethane foam specimens with densities of 136, 160 and 240 kg/m 3 were compressed in uniaxial stress tests both parallel and perpendicular to the foam rise direction, to engineering strains exceeding 70%. The uncompressed microstructures show slightly elongated ellipsoidal pores, with elongation aligned parallel to the foam rise direction. The evolution of this microstructural anisotropy during deformation is quantified based on the autocorrelation of the image intensity, and verified via the mean intercept length as well as the shape of individual pores. Trends are consistent across all three methods. In the rise direction, the material remains transversely anisotropic throughout compression. Anisotropy initially decreases with compression, reaches a minimum, then increases up to large strains, followed by a small decrease in anisotropy at the largest strains as pores collapse. Compression perpendicular to the foam rise direction induces secondary anisotropy with respect to the compression axis, in addition to primary anisotropy associated with the foam rise direction. In contrast to compression in the rise direction, primary anisotropy initially increases with compression, and shows a slight decrease at large strains. These surprising non-monotonic trends and qualitative differences in rise and transverse loading are explained based on the compression of initially ellipsoidal pores. Microstructural anisotropy trends reflect macroscopic stress-strain and lateral strain response. These findings provide novel quantitative connections between three-dimensional microstructure and anisotropy in moderate density polymer foams up to large deformation, with important implications for understanding complex three-dimensional states of deformation.

36 MATERIALS SCIENCE↗

Fourier method for 3-dimensional data fusion of X-ray Computed Tomography and ultrasound

X-ray Computed Tomography (CT) is essential for nondestructive inspection of many manufactured components but is susceptible to various forms of artifacts and noise. In particular, multi-detector row cone-beam CT systems can suffer from so called “cone-beam” artifacts and partial volume effects, particularly on planar edges at the periphery of the field of view in the cone angle dimension. Uni-directional ultrasonic testing methods generally have extremely accurate in-plane depth resolution but poorer lateral resolution due to physical and geometric constraints. This paper presents a novel technique called Computed Tomographic Fusion (CT-F) which uses three-dimensional Fourier filtering to combine x-ray cone-beam CT reconstructions and ultrasound data in the frequency space. The result is a single image with improved accuracy and quality. CT-F mitigates artifacts while allowing for rapid, accurate characterization of large three-dimensional CT volumes. Finally, using simulations and experiments, we demonstrate artifact reduction and edge contrast improvement in volumetric reconstructions.

42 ENGINEERING↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

Nanoscale microstructure and chemistry of transparent gahnite glass-ceramics revealed by atom probe tomography

The nanoscale microstructure and chemistry of a transparent gahnite glass-ceramic and its precursor glass were investigated using atom probe tomography, transmission electron microscopy, and nuclear magnetic resonance spectroscopy. In the annealed precursor glass, statistically significant ZrO clustering was observed along with Si depletion within 2 nm of the ZrO clusters. This clustering is expected to be the first step in the nucleation and crystallization of the nucleating agent, ZrO 2 . In the glass-ceramic, gahnite (ZnAl 2 O 4 ) crystallites were found to exist in proximal locations to ZrO 2 and not in a core-shell arrangement. The residual glass composition was directly measured by atom probe, showing higher concentrations of Al, Zn, and Zr than previously expected. At the interfaces between the crystallites and residual glass, no enrichment or depletion zones were found. Our findings provide answers to outstanding questions surrounding the nucleation and elemental partitioning, microstructure, and the residual glass composition of transparent gahnite glass-ceramics.

36 MATERIALS SCIENCE↗

Critical length scales for chemical heterogeneity at Cu/Nb 3D interfaces by atom probe tomography

Cu/Nb nanocomposites containing sharp, two-dimensional (2D) interfaces have outstanding strength but limited deformability. In contrast, Cu/Nb with three dimensional (3D) biphase interfaces exhibiting crystallographic, topological, and chemical variations in all spatial dimensions overcomes this limitation by simultaneously enhancing material strength and deformability. Here, while structural characterization of 3D interfaces has been performed to understand their mechanical behavior, three dimensional chemical characterization of such interfaces is lacking. In this work we quantify the local chemistry of 3D interfaces in Cu/Nb nanocomposites using atom probe tomography (APT). Our analysis demonstrates chemical heterogeneities along all spatial dimensions in 3D interfaces, establishes the length scale of such features, and quantifies the morphology of 3D interfaces. 3D interface heterogeneities form by surface diffusion during physical vapor deposition (PVD), suggesting that deposition parameters can be used to control interface structure and provide unique ways to explore processing-structure-property relationships in interface-dominated nanocomposites.

36 MATERIALS SCIENCE↗

Porosity evolution under increasing tension in wire-arc additively manufactured aluminum using in-situ micro-computed tomography and convolutional neural network

Internal defects such as porosities are often formed in additively manufactured metal components. The pores nucleate, grow, and coalesce to form cracks under loads, leading to eventual catastrophic failure. Here, in this paper, the full-field porosity evolution, including pore growth and coalescence in a wire-arc additively manufactured (WAAM) aluminum alloy cylinder under tension is observed with in-situ X-ray micro-computed tomography (μCT). The pore size distribution, density, and tensile stress are calculated from the volumetric images analyzed by a convolutional neural network (CNN) algorithm, which provides rapid analysis of 12,950 slice images from μCT volumetric images at the reference state and 13 tensile strains. The results show the quantitative evolution of the growth and coalescence of macropores under tension. A strong correlation is found between the local pore volume fraction and the true tensile stress when the tensile strain is larger than 5%.

36 MATERIALS SCIENCE↗

Soft X-ray tomography to map and quantify organelle interactions at the mesoscale

Inter-organelle interactions are a vital part of normal cellular function; however, these have proven difficult to quantify due to the range of scales encountered in cell biology and the throughput limitations of traditional imaging approaches. Here, we demonstrate that soft X-ray tomography (SXT) can be used to rapidly map ultrastructural reorganization and inter-organelle interactions in intact cells. SXT takes advantage of the naturally occurring, differential X-ray absorption of the carbon-rich compounds in each organelle. Specifically, we use SXT to map the spatiotemporal evolution of insulin vesicles and their co-localization and interaction with mitochondria in pancreatic β cells during insulin secretion and in response to different stimuli. We quantify changes in the morphology, biochemical composition, and relative position of mitochondria and insulin vesicles. These findings highlight the importance of a comprehensive and unbiased mapping at the mesoscale to characterize cell reorganization that would be difficult to detect with other existing methodologies.

3D cell mapping↗

Seeing the whole picture: Methods for getting the most from micro X-ray computed tomography of TRISO nuclear fuel particles

Tristructural isotropic (TRISO) coated fuel particles are a nuclear fuel form under extensive study for use in advanced nuclear reactor concepts. TRISO fuels are subjected to high temperature neutron irradiations and then examined to assess their performance by determining fission product retention and studying morphological changes. Micro X-ray computed tomography is one method of nondestructively studying the effects of TRISO performance. This work addresses the need for image processing to remove X-ray tomographic reconstruction artifacts that prevent the study of TRISO features, as the TRISO particles’ high Z kernel can introduce metal artifacts that degrade the image quality in the surrounding low Z coating layers. These metal artifacts were reduced by imaging the TRISO particles with both high- and low-energy X-rays and applying a mask to the radiographs obtained with low-energy X-rays to digitally remove the dense fuel kernel region. These masked radiographs were then used to produce a tomographic reconstruction which was combined with the tomographic reconstruction of the high-energy data. This enabled the relatively-low-density TRISO buffer layer to be examined in more detail, providing information on irradiation induced dimensional changes of the coatings. This methodology, which helps see the full picture of a TRISO particle, is not limited to nuclear fuels but can be applied to systems that contain highly attenuating material surrounded by less dense materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring thermal curing induced shrinkage of material extrusion based additive manufacturing silicone elastomer lattices by X-ray computed tomography

Thermal curing induces shrinkage in material extrusion based additive manufacturing silicone elastomer samples, resulting in discrepancies between as printed and final geometries. Knowing the extent to which the samples change in shape and size allows us to make appropriate modifications to the printing design to better control the geometry of the samples. We present an X-ray computed tomography (CT) based approach to determine filament-level shrinkage due to thermal curing of silicone elastomer samples printed with direct ink writing (DIW). The approach relies on custom-designed build plates that are resistant to the elevated curing temperatures and that have sufficiently distinct X-ray absorption characteristics from the silicone elastomer to ensure adequate segmentation of the latter in X-ray imaging data. We implement the approach to evaluate shrinkage in DIW ‘log pile’ samples with three distinct strand arrangements and demonstrate of how filament-level information can be extracted from the X-ray CT data.

Additive manufacturing↗

Aggregated nanoparticles: Sample preparation and analysis by atom probe tomography

Atom probe tomography (APT) allows measurement of the three-dimensional structure and composition of materials, but specific sample preparation procedures are required for challenging materials such as aggregates of nanoparticles. Indeed, the presence of porosity within the specimen affects both the stability of the sample and the accuracy of the data. In this work, aggregates of nanoparticles were transferred onto a micromanipulator tip and embedded via electron-beam-assisted deposition of Pt. Successive FIB-millings and Pt-depositions are needed to create suitable APT tips. The 3D reconstruction reveals the presence of 15–20 nm nanoparticles, and massspectral analysis shows the absence of trace elements within the catalyst, thus serving as quality control for the synthesis of nanoparticles with specific compositions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cluster characterization in atom probe tomography: Machine learning using multiple summary functions

In this work, we develop a machine learning-based method to characterize intracluster concentration (ρ c ), background concentration (ρ b ), clustering radius (r̄), and radius dispersity (δ r ) in simulated atom probe tomography data using multiple spatial statistics summary functions to train a Bayesian regularized neural network. Here, we build upon previous work that utilized Ripley’s K-function by incorporating additional features from nearest-neighbor spatial statistics summary functions to better characterize concentration-based metrics. The addition of nearest-neighbor based features allows for highly accurate estimates of ρ c and ρ b , both with 90% of the predictions within 4.0% of the real value; the root-mean-square errors are reduced by 81.5% and 92.8% from predictions using only K-function based features, respectively. Additionally, including these nearest-neighbor based features improves the ability to differentiate between r̄ and δ r .

36 MATERIALS SCIENCE↗

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

Atomic-scale characterization of (electro-)catalysts and battery materials by atom probe tomography

To optimise the performance of heterogeneous (electro-)catalysts and battery electrodes, it is essential to establish the structure-property relationships. This can only be achieved by obtaining a full three-dimensional (3D) characterisation of atomic-scale structure and chemistry of these advanced materials. Atom probe tomography (APT) can provide unique insights into 3D elemental distribution, including low atomic mass elements, with sub-nanometer spatial resolution. Despite its superior chemical analytical capability and spatial resolution, APT has limited applications for sustainable energy materials due to technical and analytical challenges. The recent developments in experimental setups, sample preparation methods and data analysis algorithms have opened the door to the possibility of analysing heterogeneous (electro-)catalysts and battery electrodes. This perspective provides an overview of these developments, exemplified by recent achievements of analyzing model heterogeneous model (electro-)catalysts, nanoparticles, zeolites, MOFs and Li-ion battery electrodes, followed by a discussion of limitations, opportunities, and potentials of APT for future scientific exploration.

atom probe tomography↗

Semi-Automated, Object-Based Tomography of Dislocation Structures

The characterization of the three-dimensional arrangement of dislocations is important for many analyses in materials science. Dislocation tomography in transmission electron microscopy is conventionally accomplished through intensity-based reconstruction algorithms. Although such methods work successfully, a disadvantage is that they require many images to be collected over a large tilt range. Here, we present an alternative, semi-automated object-based approach that reduces the data collection requirements by drawing on the prior knowledge that dislocations are line objects. Our approach consists of three steps: (1) initial extraction of dislocation line objects from the individual frames, (2) alignment and matching of these objects across the frames in the tilt series, and (3) tomographic reconstruction to determine the full three-dimensional configuration of the dislocations. Drawing on innovations in graph theory, we employ a node-line segment representation for the dislocation lines and a novel arc-length mapping scheme to relate the dislocations to each other across the images in the tilt series. We demonstrate the method for a dataset collected from a dislocation network imaged by diffraction-contrast scanning transmission electron microscopy. Based on these results and a detailed uncertainty analysis for the algorithm, we discuss opportunities for optimizing data collection and further automating the method.

47 OTHER INSTRUMENTATION↗