Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Angle between DNA linker and nucleosome core particle regulates array compaction revealed by individual-particle cryo-electron tomography

Abstract The conformational dynamics of nucleosome arrays generate a diverse spectrum of microscopic states, posing challenges to their structural determination. Leveraging cryogenic electron tomography (cryo-ET), we determine the three-dimensional (3D) structures of individual mononucleosomes and arrays comprising di-, tri-, and tetranucleosomes. By slowing the rate of condensation through a reduction in ionic strength, we probe the intra-array structural transitions that precede inter-array interactions and liquid droplet formation. Under these conditions, the arrays exhibite irregular zig-zag conformations with loose packing. Increasing the ionic strength promoted intra-array compaction, yet we do not observe the previously reported regular 30-nanometer fibers. Interestingly, the presence of H1 do not induce array compaction; instead, one-third of the arrays display nucleosomes invaded by foreign DNA, suggesting an alternative role for H1 in chromatin network construction. We also find that the crucial parameter determining the structure adopted by chromatin arrays is the angle between the entry and exit of the DNA and the corresponding tangents to the nucleosomal disc. Our results provide insights into the initial stages of intra-array compaction, a critical precursor to condensation in the regulation of chromatin organization.

59 BASIC BIOLOGICAL SCIENCES↗

Continuity of Mitochondrial Budding: Insights from BS-C-1 Cells by In Situ Cryo-electron Tomography

Mitochondrial division is a fundamental biological process essensial for cellular functionality and vitality. The prevailing hypothesis that dynamin related protein 1 (Drp1) provides principal control in mitochondrial division, in which it also involves the endoplasmic reticulum (ER) and the cytoskeleton, does not account for all the observations. Therefore. the hypothesis may be incomplete. Our previous study in HeLa cells led to a new hypothesis of mitochondrial division by budding. To follow-up our previous study, we employed in situ cryo-electron tomography to visualize mitochondrial budding in the intact healthy monkey kidney cells (BS-C-1 cells). Our findings reaffirm single and multiple mitochondrial budding, consistent with our observations in HeLa cells. Notably, the budding regions vary significantly in diameter and length, which may represent different stages of budding. More interestingly, neither rings nor ring-like structures, nor the wrapping of ER tubes was observed in the budding regions, suggesting mitochondrial budding is independent from Drp1 and ER. Meanwhile, we uncovered direct interactions between mitochondria and large vesicles that are distinct from small mitochondrial-derived vesicles and extracellular mitovesicles. In conclusion, we propose that these interacting vesicles may have mitochondrial origins.

(Cryo-EM)↗

Versatile compact heater design for in situ nano-tomography by transmission X-ray microscopy

A versatile, compact heater designed at National Synchrotron Light Source-II for in situ X-ray nano-imaging in a full-field transmission X-ray microscope is presented. Heater design for nano-imaging is challenging, combining tight spatial constraints with stringent design requirements for the temperature range and stability. Finite-element modeling and analytical calculations were used to determine the heater design parameters. Performance tests demonstrated reliable and stable performance, including maintaining the exterior casing close to room temperature while the heater is operating at above 1100°C, a homogenous heating zone and small temperature fluctuations. Two scientific experiments are presented to demonstrate the heater capabilities: (i) in situ 3D nano-tomography including a study of metal dealloying in a liquid molten salt extreme environment, and (ii) a study of pore formation in icosahedral quasicrystals. The progression of structural changes in both studies were clearly resolved in 3D, showing that the new heater enables powerful capabilities to directly visualize and quantify 3D morphological evolution of materials under real conditions by X-ray nano-imaging at elevated temperature during synthesis, fabrication and operation processes. This heater design concept can be applied to other applications where a precise, compact heater design is required.

36 MATERIALS SCIENCE↗

TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion

Synchrotron-based x-ray tomography is a noninvasive imaging technique that allows for reconstructing the internal structure of materials at high spatial resolutions from tens of micrometers to a few nanometers. In order to resolve sample features at smaller length scales, however, a higher radiation dose is required. Therefore, the limitation on the achievable resolution is set primarily by noise at these length scales. We present TomoGAN, a denoising technique based on generative adversarial networks, for improving the quality of reconstructed images for low-dose imaging conditions. We evaluate our approach in two photon-budget-limited experimental conditions: (1) sufficient number of low-dose projections (based on Nyquist sampling), and (2) insufficient or limited number of high-dose projections. In both cases, the angular sampling is assumed to be isotropic, and the photon budget throughout the experiment is fixed based on the maximum allowable radiation dose on the sample. Evaluation with both simulated and experimental datasets shows that our approach can significantly reduce noise in reconstructed images, improving the structural similarity score of simulation and experimental data from 0.18 to 0.9 and from 0.18 to 0.41, respectively. Furthermore, the quality of the reconstructed images with filtered back projection followed by our denoising approach exceeds that of reconstructions with the simultaneous iterative reconstruction technique, showing the computational superiority of our approach.

42 ENGINEERING↗

EGS Collab Experiment 1: 3D Seismic Velocity Model and Updated Microseismic Catalog from Double-Difference Seismic Tomography

This package contains a 3D Seismic velocity model and an updated microseismic catalog obtained for a double-difference seismic tomography study. The 3D_seismic_velocity_model text file contains x (m), y(m), z(m), P-wave velocity (km/s), P-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained), S-wave velocity (km/s), and S-wave velocity quality indicator (1 for well-constrained; 0 for poorly constrained). The Updated_MEQ_catalog text file contains event origin time, x(m), y(m), z(m), error in x (m), error in y (m), error in z (m), and RMS misfit (millisecond). The 3D_seismic_P-wave_velocity_model animation file shows slices of the 3D P-wave velocity model. The 3D_seismic_S-wave_velocity_model animation file shows slices of the 3D S-wave velocity model. The Interactive_MEQ_location_comparison API file is an interactive visualization of the updated microseismic event locations and the original seismic catalog. The visualization allows users to view and compare the event locations by dragging, rotating, and zooming in. An updated version of 3D_seismic_velocity_model and associated animations were included, which were calculated with a more strict assumption for quality indicators.

15 GEOTHERMAL ENERGY↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

Automated Image Segmentation and Processing Pipeline Applied to X–Ray Computed Tomography Studies of Pitting Corrosion in Aluminum Wires

Understanding pitting corrosion is critical, yet its kinetics and morphology remain challenging to study from X-ray computed tomography (XCT) due to manual segmentation barriers. To address this, an automated pipeline leveraging deep learning for efficient large-scale XCT analysis is developed, revealing new corrosion insights. The pipeline enables pit segmentation, 3D reconstruction, statistical characterization, and a topological transformation for visualization. Here, the pipeline is applied to 87 648 XCT images capturing commercial purity aluminum (1100 Al) wire exposed to sodium chloride (NaCl) salt particles over a period of 122 h. The pipeline achieves complete feature extraction and statistical quantification across the entire XCT dataset, leveraging distributed computing environment for high efficiency. Global growth kinetics such as high-level stepwise sigmoidal volume loss patterns and granular individual pit developments are both captured for 36 detected pits. By combining automation, computer vision, and extensive XCT datasets, this research accelerates precise corrosion assessment to enable materials science discoveries at scale.

36 MATERIALS SCIENCE↗

Direct Observation of Interfacial Mechanical Failure in Thiophosphate Solid Electrolytes with Operando X-Ray Tomography

Herein, the mechanical behaviors of Li 10 GeP 2 S 12 (LGPS) solid electrolytes during electrochemical cycling using operando X-ray tomography are investigated. It is demonstrated that the bulk mechanical decomposition of LGPS when cycled against lithium is a direct result of electrochemical reduction of the solid electrolyte at the LGPS/Li 0 interface. The reductive decomposition of LGPS during lithium plating results in the formation of low-density domains at the electrode/electrolyte interface, which impose sufficient mechanical stress on the underlying LGPS to crack the SE pellet. The critical stress developed prior to pellet fracture is significantly lower than the bulk shear modulus of LGPS, suggesting that the electrochemical instability of LGPS dramatically worsens the mechanical stability of the material near the LGPS/Li 0 interface. It is also shown that the application of a highly concentrated liquid electrolyte to the LGPS surface suppresses the reductive decomposition of LGPS, improving both the electrochemical performance and mechanical stability of the bulk LGPS solid electrolyte.

36 MATERIALS SCIENCE↗

Visualizing the Nanoscale Oxygen and Cation Transport Mechanisms during the Early Stages of Oxidation of Fe–Cr–Ni Alloy Using In Situ Atom Probe Tomography

Abstract Understanding the early stages of interactions between oxygen and material surfaces—especially at very high spatial resolutions—is highly beneficial for fields ranging from materials degradation, corrosion, geological sciences, forensics, and catalysis. The ability of in situ atom probe tomography (APT) is demonstrated to track the diffusion of oxygen and metal ions at nanoscale spatial resolution during the early stages of oxidation of a model Fe–Cr–Ni alloy. Using 18 O isotope tracers in these in situ APT experiments and complementary ex situ multimodal microscopy, spectroscopy, and computational simulations allows to precisely analyze the kinetics of oxidation and determine that outward cation diffusion to oxide/air interface is the primary mechanism for intragranular oxide growth in this alloy at 300 °C. This unique in situ isotopic tracer APT approach and the insights gained can be highly beneficial for studying early stages of gas–surface reactions in a broad array of materials.

36 MATERIALS SCIENCE↗

Cryogenic Correlative Single-Particle Photoluminescence Spectroscopy and Electron Tomography for Investigation of Nanomaterials

Cryogenic single-particle photoluminescence (PL) spectroscopy has been used with great success to directly observe the heterogeneous photophysical states present in a population of luminescent particles. Cryogenic electron tomography provides complementary nanometer scale structural information to PL spectroscopy, but the two techniques have not been correlated due to technical challenges. Here, we present a method for correlating single-particle information from these two powerful microscopy modalities. We simultaneously observe PL brightness, emission spectrum, and in-plane excitation dipole orientation of CdSSe/ZnS quantum dots suspended in vitreous ice. Stable and fluctuating emitters were observed, as well as a surprising splitting of the PL spectrum into two bands with an average energy separation of 80 meV. In some cases, the onset of the splitting corresponded to changes in the in-plane excitation dipole orientation. These dynamics were assigned to structures of individual quantum dots and the excitation dipoles were visualized in the context of structural features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro‐ and Nanoscale Heterogeneities in Zeolite Beta as Measured by Atom Probe Tomography and Confocal Fluorescence Microscopy

Micro- and nanoscale information on the activating and deactivating coking behaviour of zeolite catalyst materials increases our current understanding of many industrially applied processes, such as the methanol-to-hydrocarbon (MTH) reaction. Atom probe tomography (APT) was used to reveal the link between framework and coke elemental distributions in 3D with sub-nanometre resolution. APT revealed 10–20 nanometre-sized Al-rich regions and short-range ordering (within nanometres) between Al atoms. With confocal fluorescence microscopy, it was found that the morphology of the zeolite crystal as well as the secondary mesoporous structures have a great effect on the microscale coke distribution throughout individual zeolite crystals over time. Additionally, a nanoscale heterogeneous distribution of carbon as residue from the MTH reaction was determined with carbon-rich areas of tens of nanometres within the zeolite crystals. Finally, a short length-scale affinity between C and Al atoms, as revealed by APT, indicates the formation of carbon-containing molecules next to the acidic sites in the zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computer-aided Veress needle guidance using endoscopic optical coherence tomography and convolutional neural networks

During laparoscopic surgery, the Veress needle is commonly used in pneumoperitoneum establishment. Precise placement of the Veress needle is still a challenge for the surgeon. In this study, a computer-aided endoscopic optical coherence tomography (OCT) system was developed to effectively and safely guide Veress needle insertion. This endoscopic system was tested by imaging subcutaneous fat, muscle, abdominal space, and the small intestine from swine samples to simulate the surgical process, including the situation with small intestine injury. Each tissue layer was visualized in OCT images with unique features and subsequently used to develop a system for automatic localization of the Veress needle tip by identifying tissue layers (or spaces) and estimating the needle-to-tissue distance. We used convolutional neural networks (CNNs) in automatic tissue classification and distance estimation. In conclusion, the average testing accuracy in tissue classification was 98.53 ± 0.39%, and the average testing relative error in distance estimation reached 4.42 ± 0.56% (36.09 ± 4.92 μm).

59 BASIC BIOLOGICAL SCIENCES↗

Effect of hydration on morphology of thin phosphonate block copolymer electrolyte membranes studied by electron tomography

The morphological changes of phosphonate polypeptoid electrolyte membranes, poly-N-(2-ethyl)hexylglycine-block-poly-N-phosphonomethylglycine (pNeh m -b-pNpm n ), in hydrated and dry states were characterized by cryogenic transmission electron microscopy (cryo-TEM) and cryogenic electron tomography (cryo-ET). The analysis of 3D tomograms revealed that the pNeh 9 -b-pNpm 9 thin films absorbed a large amount of water, resulting in the formation of membranes that were nearly flat and giant multicompartment vesicles dispersed in the water phase. A simple lamellar phase appeared when the films were dried. In contrast, pNeh 18 -b-pNpm 18 thin films absorbed little water and formed small highly curved unilamellar and multilamellar vesicles. Water was located mainly outside the closely-packed vesicles. When water was removed by drying, the walls of adjacent vesicles collapsed to form honeycomb-like capsules. Here, the changes in domain size reflected changes in chain conformations. The pNpm9 blocks were saturated by water and fully extended, while pNpm 18 blocks were neither saturated by water nor fully extended. In addition, the thicknesses of hydrophobic blocks in the hydrated films of both pNeh 9 -b-pNpm 9 and pNeh 18 -b-pNpm 18 were smaller than those in the dry films, reflecting an increase of the average distance between the neighboring junctions of polypeptoid molecules.

36 MATERIALS SCIENCE↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Nanoscale Perspectives of Metal Degradation via In Situ Atom Probe Tomography

Abstract We report a unique in situ instrument development effort dedicated to studying gas/solid interactions relevant to heterogeneous catalysis and early stages of oxidation of materials via atom probe tomography and microscopy (APM). An in situ reactor cell, similar in concept to other reports, has been developed to expose nanoscale volumes of material to reactive gas environments, in which temperature, pressure, and gas chemistry are well controlled. We demonstrate that the combination of this reactor cell with APM techniques can aid in building a better mechanistic understanding of resultant composition and surface and subsurface structure changes accompanying gas/surface reactions in metal and metal alloy systems through a series of case studies: O 2 /Rh, O 2 /Co, and O 2 /Zircaloy-4. In addition, the basis of a novel operando mode of analysis within an atom probe instrument is also reported. The work presented here supports the implementation of APM techniques dedicated to atomic to near-atomically resolved gas/surface interaction studies of materials broadly relevant to heterogeneous catalysis and oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Quantifying Pore Morphology in Spray-Formed Tantalum Using X-ray Micro-computed Tomography

In order to establish quantitative process–structure–property relationships in thermal spray coatings, a robust framework for defining (micro)structural characteristics is needed. Here, we present a quantitative characterization of the three-dimensional morphology of porosity in spray-formed tantalum samples based on high-resolution X-ray micro-computed tomography. Using synchrotron facilities, we acquired dozens of high-resolution scans, enabling a statistically meaningful comparison across multiple samples, different regions within samples, and spray processes. We quantify the spatial distribution, size, and topology of porous inclusions, with a significant focus on variability across samples and different spray processes (plasma and cold sprayed), as well as sensitivity to image segmentation and resolution. Based on a typical segmentation, we report porosities ranging from 0.9 to 1.7 pct for all samples tested, with significant sensitivity due to image segmentation resulting in estimates as low as 0.6 pct and as high as 4.8 pct. For the complex pore space morphology observed in these materials, we argue that a conventional analysis based on identifying individual pores is not well suited, and propose an alternative approach based on morphological metrics with a rich history in porous media literature, such as spatial correlations, local pore thickness, and scale-dependent sub-sampling. Spatial correlations indicate anisotropic splat structures, but only mildly anisotropic pores. Various measures of pore size show a wide distribution of sizes, ranging from sub-micron to 10-micron length scales. Scale-dependent variations in porosity suggest that representative volumes of several hundred microns are required for convergence of morphological metrics, with larger volumes for cold-spray materials. This work provides a robust quantitative basis for describing three-dimensional pore structure in thermal spray coatings.

36 MATERIALS SCIENCE↗