Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Studies of a Proton Bunch Phase Monitor for Range Verification in Proton Therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and is directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a bunch phase monitor can be performed. A first prototype of bunch phase monitor was tested at GSI Darmstadt, where measurements of the energy correlation profile of the ion bunches were performed. At the ELBE accelerator at Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Onco Ray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Mu2e crystal calorimeter and improvements in the $\mu^-\mbox{N} \to e^-\mbox{N}$ search sensitivity

The Mu2e experiment will search for Charged Lepton Flavor Violation (CLFV) looking at the conversion of a muon into an electron in the field of an aluminum nucleus. About $7\cdot 10^{17}$ muons, provided by a dedicated muon beam line in construction at the Fermi National Accelarator Laboratory (Fermilab), will be stopped in 3 years in the Aluminum target. The corresponding single event sensitivity will be $2.5\cdot 10^{-17}$. The Standard Model of particle physics, even extendend to include the finite neutrino masses, predicts the ratio R μe between muon conversions and muon nuclear captures to be $\sim 10^{- 52}$. Several extensions of the Standard Model predict R μe to be in the range of $10^{-14} - 10^{-18}$. % The current best experimental limit, set by the SINDRUM II experiment is $7 \cdot 10^{-13}$ @ $90\%$ CL. The Mu2e experiment plans to improve this experimental limit by four order of magnitude to test many of the possible extensions of the Standard Model. To reach this ambitious goal, the Mu2e experiment is expected to use an intense pulsed muon beam, and rely on a detector system composed of a straw tube tracker and a calorimeter made of pure CsI crystals. The calorimeter plays a central role in the Mu2e measurement, providing particle identification capabilities that are necessary for rejecting two of the most dangerous background sources that can mimic the μ⁻N → e⁻N conversion electron: cosmic muons and $\bar{p}$ induced background. The calorimeter information allows also to improve the tracking performance. Thanks to a calorimeter-seeded track finder algorithm, it is possible to increase the track reconstruction efficiency, and make it more robust with respect to the occupancy level. Expected performances of the calorimeter have been studied in a beam test at the Beam Test Facility in Frascati (Rome, Italy). A reduced scale calorimeter prototype has been exposed to an electron beam, with energy varying from 80 to 140 MeV, for measuring the timing resolution and validate the Monte Carlo prediction. A timing resolution $\sigma_{\rm t}<200$ ps @ 100 MeV has been obtained. Combination of the background rejection performance, and the improvements in the track reconstruction, have then been used in the calculation of the expected Mu2e sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of AXUV diode detectors at ASDEX Upgrade

In the ASDEX Upgrade tokamak, a radiation measurement for a wide spectral range, based on semiconductor detectors, with 256 lines of sight and a time resolution of 5μs was recently installed. In combination with the foil based bolometry, it is now possible to estimate the absolutely calibrated radiated power of the plasma on fast timescales. This work introduces this diagnostic based on AXUV (Absolute eXtended UltraViolet) n-on-p diodes made by International Radiation Detectors, Inc. The measurement and the degradation of the diodes in a tokamak environment is shown. Even though the AXUV diodes are developed to have a constant sensitivity for all photon energies (1 eV-8 keV), degradation leads to a photon energy dependence of the sensitivity. The foil bolometry, which is restricted to a time resolution of less than 1 kHz, offers a basis for a time dependent calibration of the diodes. The measurements of the quasi-calibrated diodes are compared with the foil bolometry and found to be accurate on the kHz time scale. Therefore, it is assumed, that the corrected values are also valid for the highest time resolution (200 kHz). With this improved diagnostic setup, the radiation induced by edge localized modes is analyzed on fast timescales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A new time calibration method for switched-capacitor-array-based waveform samplers

Here we have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. Ultimately, the new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concentration, temperature, and density in a hydrogen-air flame by excimer-induced Raman scattering

Single-pulse, vibrational Raman scattering (VRS) is an attractive laser diagnostic for the study of supersonic hydrogen-air combustion. The VRS technique gives a complete thermodynamic description of the gas mixture at a point in the reacting flow. Single-pulse, vibrational Raman scattering can simultaneously provide independent measurements of density, temperature, and concentration of each major species (H2, H2O, O2 and N2) in a hydrogen/air turbulent combustor. Also the pressure can be calculated using the ideal gas law. However, single-pulse VRS systems in current use for measurement of turbulent combustion have a number of shortcomings when applied to supersonic flows: (1) slow repetition rate (1 to 5 Hz), (2) poor spatial resolution (0.5x0.3x0.3 cu mm), and (3) marginal time resolution. Most of these shortcomings are due to the use of visible wavelength flash-lamp pumped dye lasers. The advent of UV excimer laser allows the possibility of dramatic improvements in the single-pulse, vibrational Raman scattering. The excimer based VRS probe will greatly improve repetition rate (100 to 500 Hz), spatial resolution (0.1x0.1x0.1 cu mm) and time resolution (30ns). These improvements result from the lower divergence of the UV excimer, higher repetition rate, and the increased Raman cross-sections (15 to 20 times higher) at ultra-violet (UV) wavelengths. With this increased capability, single-pulse vibrational Raman scattering promises to be an ideal non-intrusive probe for the study of hypersonic propulsion flows.

Wehrmeyer, Joseph A.↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

We estimate the long-run economic value of variable renewable generation with increasing penetration using a unique investment and dispatch model that captures long-run investment decisions while also incorporating detailed operational constraints and hourly time resolution over a full year. High time resolution and the incorporation of operational constraints are important for estimating the economic value of variable generation, as is the use of a modeling framework that accommodates new investment decisions. The model is herein applied with a case study that is loosely based on California in 2030. Increasing amounts of wind, photovoltaics (PV), and concentrating solar power (CSP) with and without thermal energy storage (TES) are added one at a time. The marginal economic value of these renewable energy sources is estimated and then decomposed into capacity value, energy value, day-ahead forecast error cost, and ancillary services. The marginal economic value, as defined here, is primarily based on the combination of avoided capital investment cost and avoided variable fuel and operations and maintenance costs from other power plants in the power system. Though the model only captures a subset of the benefits and costs of renewable energy, it nonetheless provides unique insights into how the value of that subset changes with technology and penetration level. Specifically, in this case study implementation of the model, the marginal economic value of all three solar options is found to exceed the value of a flat-block of power (as well as wind energy) by \$20--30/MWh at low penetration levels, largely due to the high capacity value of solar at low penetration. Because the value of CSP per unit of energy is found to be high with or without thermal energy storage at low penetration, we find little apparent incremental value to thermal storage at low solar penetration in the present case study analysis. The marginal economic value of PV and CSP without thermal storage is found to drop considerably (by more than \$70/MWh) as the penetration of solar increases toward 30\percent on an energy basis. This is due primarily to a steep drop in capacity value followed by a decrease in energy value. In contrast, the value of CSP with thermal storage drops much less dramatically as penetration increases. As a result, at solar penetration levels above 10\percent, CSP with thermal storage is found to be considerably more valuable relative to PV and CSP without thermal storage. The marginal economic value of wind is found to be largely driven by energy value, and is lower than solar at low penetration. The marginal economic value of wind drops at a relatively slower rate with penetration, however. As a result, at high penetration, the value of wind can exceed the value of PV and CSP without thermal storage. Though some of these findings may be somewhat unique to the specific case study presented here, the results: (1) highlight the importance of an analysis framework that addresses long-term investment decisions as well as short-term dispatch and operational constraints, (2) can help inform long-term decisions about renewable energy procurement and supporting infrastructure, and (3) point to areas where further research is warranted.

14 SOLAR ENERGY↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision timing measurements for high energy photons

Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm 3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm 3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

43 PARTICLE ACCELERATORS↗

Time characteristics of detectors based on silicon photomultipliers for the GlueX experiment

Here, silicon photomultipliers (SiPMs) are used in detectors of the GlueX experiment devoted to studying the nature of confinement. These detectors are operable at counting rates as high as 2 MHz with a time resolution (FWHM) of approximately 0.3 ns and a number of excited pixels of up to 10 4 . For SiPMs that operate under these conditions, the measured dependences of the recovery time and the time resolution are presented as functions of the number of excited pixels and the excitation frequency. Using a picosecond laser, the time resolution has been measured for an array of 4 × 4 SiPMs, which was specially developed for the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for future solar-wind missions

Possible activities and future goals for solar wind research in the post Soho era are discussed. Two major enterprises which will open up important fields in the future study of the Sun are addressed. The first deals with in situ study of the solar corona, a region that has not been accessible for direct study in the past. This exploratory work will include the coronal heating and the acceleration of the solar wind much closer to its origin and the determination of the charge states of a large number of ions as a diagnostic tool for fractionation processes in these regions. The second major goal will be the setting up of a baseline for the isotopic composition in the solar system by studying a sample from the Sun in detail. These studies will be complemented by a direct comparison with extra solar samples of interstellar pick up ions, which become accessible with the same instrumentation as is necessary for the detailed investigation of the solar wind's isotopic composition. In order to achieve these goals, advanced composition experiments are developed to investigate the solar wind with enhanced mass resolution, considerably increased geometrical factor, and improved time resolution. The placing of sophisticated mass/charge spectrometers, with the ability to investigate both charge and velocity distributions with enhanced time resolution, in the solar wind acceleration region, is also proposed.

Bochsler, P.↗

Asynchronous space–time domain decomposition method with localized uncertainty quantification

The computational cost associated with uncertainty quantification of engineering problems featuring localized phenomenon can be reduced by confining the random variability of the model parameters within a region of interest. Here in this case, a localized treatment of mesh and time resolutions is required to capture the effect of the confined material uncertainty on the global response. We present a computational approach for localized uncertainty quantification with the capability of asynchronous treatment of mesh and time resolutions. In particular, we allow each subdomain to have its local uncertainty representation and the corresponding mesh and time resolutions. As a result, computing resources can be directed toward a small region of interest where a model with high spatial and temporal resolutions is required. To verify the numerical implementation, we consider elastic wave propagation in an axially loaded beam. Moreover, we perform convergence studies with respect to the spatial and temporal discretizations as well as the size of an uncertain subdomain. A projectile impacting a composite sandwich plate is considered as an engineering application for the proposed method.

42 ENGINEERING↗

Preliminary design of a tangentially viewing imaging bolometer for NSTX-U

The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm{sup 2} for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $\mu$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100% fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 μm width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. Overall, the experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

47 OTHER INSTRUMENTATION↗