Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Performance stability of plastics for neutron-gamma pulse shape discrimination

The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Here, studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5-Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5–10 years in comparison to previous EJ-276 that might lose up to 30–40 % of the scintillation light during 1–2 years of storage or deployment under ambient conditions.

36 MATERIALS SCIENCE↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparisons of Nodal diffusion and whole-core transport methods for multiple cycles of a small Light water reacto

As part of a cooperative research and development agreement between the US department of Energy's Oak Ridge National Laboratory and Holtec International subsidiary SMR LLC, core simulator models of the SMR-160, a light water-cooled and -moderated, natural circulation, small modular reactor, were developed and compared. The model results indicate pin-by-pin power histories, critical boron concentration, and other key performance indicators useful for developing multi-cycle core loading patterns. One model uses industry standard nodal methods with a simple thermal-hydraulics solution, and the other uses an advanced deterministic neutronics solver with a coupled subchannel calculation. The goals of the comparison are to provide the reactor designer with a detailed and coupled core physics reference solution, inform the reactor designer of nodal model best practices based on the code-to-code comparison, and set up a workflow for performing subsequent detailed core simulator calculations. The results of this work will be used in the development of coupled neutronic, thermal hydraulic, and fuel performance models for advanced analysis of the SMR-160. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A IR TMIST 3B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A ATF (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A ATF which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Pulsed Die-Away Experiments at LLNL [Slides]

This presentation discusses why PNDA is ideal for TSL validations as it does not require fissile material, it has very simple target shapes and compositions, it is only sensitive to absorption and scattering of target medium, and that well conducted experiments have uncertainties of 0.1% - 0.5%. The presentation concludes by examining PNDA’s advantages and its role in nuclear data validations as it offers a cost-effective experiment for an integral benchmark, it provides the ability to focus on specific cross section data validation including thermal neutron absorption and thermal scattering laws, and the low experimental uncertainty makes it an excellent benchmark candidate. Additionally, it is easily tunable and can facilitate temperature dependent cross section validation by cooling or heating up targets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 169A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of ( 1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle. All "SR" holder monitor wires for this cycle are 55 inches long. This length allows measurements from 24.73 inches above core midplane to 25.25 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sub-critical assembly die-away analysis with organic scintillators

Determining the reactivity of systems containing fissile material is essential for verifying safety, and possession and enrichment levels. The goal of this experiment was to characterize a subcritical nuclear fuel assembly irradiated by a pulsed neutron generator through differential die-away analysis. Similar characterizations are commonly performed with thermal neutron detectors, but these detectors are bulky and cumbersome, the materials are not widely available, and timing can be clouded by the required thermalization time. In this work, an organic scintillator capable of detecting both neutrons and photons was used to measure the die-away profiles of both particles. These time profiles were then used to estimate the reactivity of the assembly. Here, the calculated reactivity estimates compare favorably to simulated estimates, and therefore provide a useful tool for fissile material characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Fundamental Studies of Tritium Formation and Diffusivity in Pure and Defective Zircaloy-4 Getters

Zirconium (Zr) alloys have excellent mechanical properties at high temperature and are resistant to corrosion in different environmental conditions. These alloys are used as tritium (3H or T) getters in nuclear reactors due to their low absorption cross section to thermal neutrons and excellent thermo-mechanical properties. Zr alloys have better mechanical and thermal properties than many other refractory alloys including stainless steel. After the irradiation of TPBAR by neutron flux, 3H produced during irradiation diffuses though the pellets and is captured by the getter. 3H chemically reacts with Zr metal to form metal hydride (ZrTx). Hydrides thus formed are brittle and adversely affect the mechanical and thermal properties of alloys. The lattice mismatch at the interface of alloy and metal hydrides also creates a stress that significantly reduces the alloy’s performance and operation life. Therefore, understanding the behavior of 3H and its species becomes significant as fuel burnup is increased, which leads to increase in hydrogen pickup and oxide formation.

Duan, Yuhua↗

Thermal Spectrum Molten Salt-Fueled Reactor Reference Plant Model

This report details a fully coupled neutronics thermal hydraulics reference plant model for a thermal spectrum molten salt-fueled reactor. The Multiphysics model is developed on the Nuclear Regulatory Commission's Comprehensive Reactor Analysis Bundle available on the Idaho National Laboratory high-performance computer, which natively and seamlessly couples Griffin and Sam codes of the Multiphysics Object-Oriented Simulation Environment (MOOSE) based applications. Griffin provides the reactor physics capabilities, k-eigenvalue, delayed neutron precursor concentrations, and transient solutions for stationary and flowing fuels. Sam provides the solution of mass, momentum, and energy conservation equations of the whole system with a set of system components for one-dimensional single-phase flow. The neutronics feedback model relies primarily on fuel and moderator temperatures, fuel salt density, and delayed neutron precursors distributions. This report presents our results for the coupled steady state core and an unprotected loss of flow event. Although this model is prototypical regarding capabilities in the Comprehensive Reactor Analysis Bundle, its results are consistent with experimental data of the pump transient tests that were performed at zero power of the Molten Salt Reactor Experiment (MSRE).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene

A critical experiment was performed on the Planet assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Porosity in nuclear graphite and its impact on nuclear reactor science and criticality safety applications

Porosity in nuclear-grade graphite significantly influences its low-energy neutron scattering, yet its effect on underlying phonon properties remains debated. Here, this work integrates inelastic and small-angle neutron scattering (INS/SANS) experiments, advanced atomistic simulations with a novel machine-learned potential (DeepMD), total cross-section measurements, and neutronics calculations (SCALE, MCNP, OpenMC) to investigate porosity’s impact on neutron thermalization. INS measurements on diverse graphite grades reveal no discernible porosity effect on phonon spectra, which align with crystalline graphite. Conversely, total cross-section data below ≈10 meV show increased scattering attributable to SANS. Our DeepMD simulations demonstrate that realistic micropores do not distort phonon spectra, challenging the assumptions in current ENDF/B-VIII.1 porosity thermal scattering laws (TSLs). These TSLs, based on random atom removal, produce unphysical phonon spectra and inflate inelastic cross-sections. Augmenting a crystalline TSL with an SANS component accurately captures experimental total cross-sections. Neutronics benchmarks (ICSBEP/IRPhE) show ENDF porosity TSLs unphysically increase neutron multiplication factor, keff. Crucially, incorporating SANS physics (NCrystal/OpenMC) indicates accurately modeled porosity negligibly affects keff, reactor physics, or criticality safety.

Critical benchmarks↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 167A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 167A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. The report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NASA: Structure and Thermophysical Properties of Delta and Epsilon Zry4H x

Small-modular and micro-reactors are part of an emerging nuclear technology aimed to provide power to decentralized grids in civilian, industrial, and defense energy sectors. Resurgence in microreactor research is partly driven by demands for a mobile, safe, and compact energy platform for remote and strategic locations. The defining characteristics of the microreactor include its high-power density on a small footprint, its highly transportable design, and the use of high-assay low-enriched uranium (HALEU) fuel. Solid-state metal hydride neutron moderator components are considered for microreactor designs where the moderator functions to thermalize neutrons into lower energies for the fuel to achieve high fission rates. Zirconium hydride (ZrH x where x denotes the atomic hydrogen-to-metal ratio) is a leading moderator candidate material due to the combination of its low neutron absorption cross section, irradiation resistance, high hydrogen atomic density (upwards of 7.5 x 10 22 H atoms/cm 3 at low temperatures), and high hydrogen desorption (dissociation) temperature around 600 °C (873 K) compared to other metal hydrides. Its high-temperature stability enables operation of fuel temperatures into several hundred degrees Celsius for overall increased efficiency.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resonant neutron scattering lengths

Unlike most of the periodic table, many rare-earth elements display considerable resonant scattering for thermal neutrons. Although this property is accompanied by strong neutron absorption, modern high-intensity neutron sources make diffraction experiments possible with these elements. Computation of scattering intensities is accomplished by fitting the variation in resonant scattering lengths ( b 0 , b ′ and b ′′) to a semi-empirical Breit–Wigner formalism, which can be evaluated over the range of neutron energies useful for diffraction, typically E = 10–600 meV; λ = 0.4–2.8 Å (with good extrapolation to longer wavelengths).

Von Dreele, Robert B. (ORCID:0000000253390634)↗

Proposed Methodology for Evaluating and Validating TSLs [Slides]

This presentation begins by providing an overview of the research and discusses recent efforts in validating thermal neutron scattering cross sections, including differential cross section measurements at ORNL for evaluation and validation, total cross section measurements at RPI, pulsed-neutron die-away experiments at LLNL, and integral criticality experiments by LLNL. The presentation also proposes a methodology not only for validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on polystyrene. In conclusion, polystyrene evaluation was conducted using multiple experiments, including differential and integral. The proposed methodology has been shown to improve neutron transport and files have been submitted to NNDC for inclusion in ENDF/B-VIII.1 release. MCT-012 & PCM-002 has been relatively insensitive to changes in $\mathcal{S}(α,β)$. The research found that differences in differential results don’t always propagate to differences in integral results, hence why evaluation of differential data important. Future work on the project is also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗