Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

MCNP Simulations of Measurement of Insulation Compaction in the Cryogenic Rocket Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

MCNP simulations have been run to evaluate the feasibility of using a combination of fast and thermal neutrons as a nondestructive method to measure of the compaction of the perlite insulation in the liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC). Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. When heated it expands from four to twenty times its original volume which makes it very useful for thermal insulation. The cryogenic tanks at Kennedy Space Center are spherical with outer diameters of 69-70 feet and lined with a layer of expanded perlite with thicknesses on the order of 120 cm. There is evidence that some of the perlite has compacted over time since the tanks were built 1965, affecting the thermal properties and possibly also the structural integrity of the tanks. With commercially available portable neutron generators it is possible to produce simultaneously fluxes of neutrons in two energy ranges: fast (14 Me V) and thermal (25 me V). The two energy ranges produce complementary information. Fast neutrons produce gamma rays by inelastic scattering, which is sensitive to Fe and O. Thermal neutrons produce gamma rays by prompt gamma neutron activation (PGNA) and this is sensitive to Si, Al, Na, K and H. The compaction of the perlite can be measured by the change in gamma ray signal strength which is proportional to the atomic number densities of the constituent elements. The MCNP simulations were made to determine the magnitude of this change. The tank wall was approximated by a I-dimensional slab geometry with an 11/16" outer carbon steel wall, an inner stainless wall and 120 cm thick perlite zone. Runs were made for cases with expanded perlite, compacted perlite or with various void fractions. Runs were also made to simulate the effect of adding a moderator. Tallies were made for decay-time analysis from t=0 to 10 ms; total detected gamma-rays; detected gamma-rays from thermal neutron reactions d. detected gamma-rays from non-thermal neutron reactions and total detected gamma-rays as a function of depth into the annulus volume. These indicated a number of possible independent metrics of perlite compaction. For example the count rate for perlite elements increased from 3600 to 8500 cps for an increase in perlite density from 6 lbs/lcf to 16.5 lbs/cf. Thus the MCNP simulations have confirmed the feasibility of using neutron methods to map the compaction of perlite in the walls of the cryogenic tanks.

Livingston, R. A.↗

Polyvinyl Alcohol and Medium Density Polyethylene Composite Materials for Neutron Radiation Shielding

Manned spacecraft venturing beyond the Earth’s Van Allen Belts will be subjected to high levels of radiation from both energetic particles emanating from the sun and from galactic atomic events, such as supernovae. The metal shell of a spacecraft offers some protection from gamma radiation and high energy particles originating from both the sun and cosmic sources. The interaction of these high energy particles and radiation with the spacecraft hull create secondary radiation and neutrons, additional hazards for astronauts and electronic systems. Shielding of neutrons is the most challenging of the high energy radiation, since neutrons have zero charge and are least affected by electrical fields, magnetic fields, and atomic forces. Previous studies showed that polyethylene is an effective neutron shielding material, due to its high hydrogen content. High energy neutrons are slowed to thermal neutrons through multiple collisions with the hydrogen atoms, increasing the effectiveness of neutron capture by boron-10 atoms. This study discusses the fabrication and testing of polyvinyl alcohol (PVOH) samples as a neutron shielding material, with comparison to medium density polyethylene (MDPE) composite samples to be used for neutron shielding for spacecraft. PVOH, an aqueous polymer, was chosen for hydrogen content and for enabling the use of organic reinforcement such as cellulose for secondary structural composites. OLTARIS (On-Line Tool for the Assessment of Radiation in Space) was used for radiation shielding simulation and compared with experimental data. Modeling indicates that the most effective shielding from radiation was in an aluminum layer backed by a polymer layer, either MDPE or PVOH. Cross-linked PVOH was also included in the OLTARIS modeling. All 3 polymer cases showed shielding improvement over aluminum alone, with similar dose equivalent reduction for galactic cosmic radiation(GCR)and for radiation from a solar particle event (SPE). Fourier Transform Infrared (FTIR) Spectroscopy was used to confirm the cross-linking in the PVOH sample and to determine the uniformity through the thickness. PVOH, cross-linked PVOH, and MDPE samples were tested for neutron shielding effectiveness using a 1 curie Americium-Beryllium neutron source. Test results indicated the most shielding in the cross-linked PVOH, followed by the pristine PVOH, and MDPE. Neutron testing suggests that polyvinyl alcohol is a good alternative to polyethylene for neutron shielding. The neutron shielding materials, PVOH and cross-linked PVOH developed under this research will enable the safe operation of spacecraft beyond the Earth’s protective Van Allen Radiation Belts. It will be crucial for NASA’s manned missions to the Moon or Mars to protect the health of astronauts and equipment from the harmful effects of excessive radiation.

neutron, shielding, radiation, polyvinyl alcohol, ↗

Mid-Latitude Composition of Mars from Thermal and Epithermal Neutrons

Epithermal neutron data acquired by Mars Odyssey have been analyzed to determine global maps of water-equivalent hydrogen abundance. By assuming that hydrogen was distributed uniformly with depth within the surface, a map of minimum water abundance was obtained. The addition of thermal neutrons to this analysis could provide information needed to determine water stratigraphy. For example, thermal and epithermal neutrons have been used together to determine the depth and abundance of water-equivalent hydrogen of a buried layer in the south polar region. Because the emission of thermal neutrons from the Martian surface is sensitive to absorption by elements other than hydrogen, analysis of stratigraphy requires that the abundance of these elements be known. For example, recently published studies of the south polar region assumed that the Mars Pathfinder mean soil composition is representative of the regional soil composition. This assumption is partially motivated by the fact that Mars appears to have a well-mixed global dust cover and that the Pathfinder soil composition is representative of the mean composition of the Martian surface. In this study, we have analyzed thermal and epithermal neutron data measured by the neutron spectrometer subsystem of the gamma ray spectrometer to determine the spatial distribution of the composition of elements other than hydrogen. We have restricted our analysis to mid-latitude regions for which we have corrected the neutron counting data for variations in atmospheric thickness.

T H Prettyman↗

Applying Methodology for Evaluating and Validating TSLs to Materials of Interest to NCSP [Slides]

This presentation covers the topic of applying methodology for evaluation validation of TSLs to material of interest to the Nuclear Criticality Safety Program (NCSP). The talk covers recent efforts in validating thermal neutron scattering cross sections. The presentation also proposes a methodology for not only validating thermal scattering files that utilizes all available experimental data, but also for evaluating new libraries as demonstrated on Polystyrene and Lucite

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tensile properties of powder-metallurgical-processed tungsten alloys after neutron irradiation near recrystallization temperatures

The tensile properties of powder-metallurgical-processed Pure W, K-doped W, W-3%Re, and K-doped W-3%Re were examined after neutron irradiation up to 0.7 dpa at 910–1020 °C with a thermal neutron shield in the High Flux Isotope Reactor (HFIR). After irradiation, recrystallized Pure W (R) exhibited a brittle fracture mode, while recrystallized K-doped W-3%Re (R) exhibited a ductile fracture mode at 500 °C. K-doped W-3%Re (R) has fine grains, and hence, contains a considerable number of grain boundaries that act as sinks for irradiation defects. Solid solute Re in the W matrix could improve not only the mechanical properties of W, but also its resistance to neutron irradiation. At 500 °C, the ductility of K-doped W-3%Re after irradiation was significantly higher than that of Pure W. The irradiation at ~1000 °C did not induce hardening of stress-relieved (SR) W materials, but SR W materials tended to exhibit a decrease in the ultimate tensile strength (UTS) and an increase in total elongation (TE). Here, the softening due to the recovery and recrystallization of SR W materials and the hardening due to the formation of irradiation defect clusters were balanced during irradiation at ~1000 °C, and ductility was exhibited without an increase in strength.

36 MATERIALS SCIENCE↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Los Alamos neutron spectrometer for the Lunar Scout-1 mission

We review the current status of the Los Alamos program to develop a neutron spectrometer for the Lunar Scout-1 mission, which is the first of two such missions to obtain global compositional, gravity, topography, and image maps of the lunar surface during nominal one-year missions. The neutron spectrometer will measure fast and slow (epithermal and thermal) neutrons in the ranges of 0.5 MeV to 25 MeV and 0.01 eV to more than 1 keV, respectively. The neutron spectrometer will consist of two independent instruments, a fast-neutron one, and a thermal and epithermal one. The measured neutron fluxes are very sensitive to hydrogen in the top meter of the lunar surface and provide additional information about lunar composition.

Auchampaugh, George↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integral Experiment Request 523 CED-2 Report

This report documents the final design phase of the Critical Experiment Design (CED-2) conducted as part of integral experiment request (IER) 523. The purpose of IER 523 is to determine critical configurations of 35 weight percent (wt%) enriched uranium dioxide beryllium oxide (UO 2 -BeO) material driven by an annular ring of Seven Percent Critical Experiment (7uPCX) fuel rods at Sandia National Laboratories (Sandia). The experiments will provide benchmark data on water moderated, intermediately enriched UO2 systems as well as Be nuclear data. The experiment will also provide partial validation for the beryllium oxide (BeO) thermal neutron scattering law (TSL) in the thermal energy range. Experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented. This report builds on the feasibility and justification of experimental need report (CED-0) and preliminary experiment design report (CED-1) completed in December 2021 and September 2023, respectively [1, 2].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distribution of Neutrons in a Cold Lucite Moderator

A series of experiments was performed in 2010 to study the behavior of neutrons in a cold Lucite moderator. The diffusion of neutrons in a cold moderator is described as a two-step process. In the first step, the fast neutrons produced by a neutron source collide with the nuclei of Lucite, losing energy until they reach thermal energies. In the second step, the thermal neutrons continue to diffuse without any significant loss of energy until they are absorbed or leak out of the system. However, because the Lucite moderator is at low temperature, there is less up scattering in the neutron energy compared to a Lucite moderator at room temperature. Experiments were performed to study the behavior of neutrons and their distribution in a cold Lucite moderator and their results compared to simulations. Based on these measurements, an estimation of the absorption cross section at -78.5 °C yielded a value of 0.54 barns ± 0.02 barns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compositional studies of the lunar regolith at the Apollo 17 site

Major-, minor-, and trace-element abundance data are presented for twenty-two Apollo 17 samples, twelve Apollo 16 samples, and one Apollo 15 basalt. The data were obtained by INAA employing a 14 MeV neutron generator, a Cf-252 isotopic neutron source and nuclear reactor thermal neutrons. Abundance summations for the twenty-four samples analyzed for major and minor abundance elements averaged 98.8 plus or minus 0.3%. Similarities between the Apollo 17 and the Apollo 11 mare basalts are discussed. Abundances in 13 Apollo 17 soils exhibit the greatest compositional range we have observed for soils from a specific landing site. A strong inverse Fe-Al correlation in all lunar materials we have analyzed with the exception of most Apollo 16 samples is defined by the equation: %Fe = -1.36 %Al + 21.5. A strong direct Mn-Fe correlation is defined by the equation: %Fe = 75.9 %Mn + 0.08. Both regression lines appear to have the mare basalts, as one end-member and an unspecified Al-rich component at the other end. Comparisons of the data from direct O determinations and calculated O abundances based on normal stoichiometry are presented.

Miller, M. D.↗

Measuring planetary hydrogen by remote gamma-ray sensing

The detection and measurement of hydrogen concentration and neutron leakage flux in planetary bodies by means of a proximate gamma-ray spectrometer (GRS) are discussed. The H concentration and the neutron flux are intimately linked in the planetary surface, and the measurement of hydrogen is dependent on knowledge of the neutron flux. The capture of thermal neutrons is responsible for the production of the 2.223 MeV line which characterizes hydrogen. The 2.223 MeV H signal is observed in the gamma-ray spectrum against an interference spectrum consisting of cosmic gamma rays, planetary background emission, and gamma rays arising from the interaction of cosmic rays with the GRS and the spacecraft (SC). An interfering line background results from the interaction of slow neutrons with H in the GRS and SC. The sources and magnitudes of the signal and background components in the H band are identified in terms of two missions, a lunar orbiter and a comet nucleus rendezvous. For the lunar mission, a 100 h observation at a 100 km altitude permits the detection of H at a level of 0.06 percent with an uncertainty of about 0.02 percent, while at an altitude equal to the radius of the comet's nucleus, in 100 h a GRS detects H at a level of 0.07 percent with an uncertainty of 0.06 percent.

Haines, E. L.↗