Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

1:52 Scale Testing of the First US Commercial Scale Floating Wind Turbine, VolturnUS: Testing Overview and the Evolution of Scale Model Testing Methods

Over the past 6 years, the University of Maine (UMaine) has been an active contributor in research and scale-model testing of floating offshore wind turbines (FOWTs). This paper serves to share the evolution of UMaine’s scale-model testing pedigree by exploring the various test campaigns at a high level, culminating with the design validation of the VolturnUS floating platform. These model test campaigns have each provided key insights into the behavior of FOWT platforms as well as improving the ability to perform model tests of FOWTs. In 2011, the UMaine-led DeepCwind Consortium carried out 1/50-scale model tests of a generic tension leg platform (TLP), a semi-submersible (semi), and a spar-buoy (spar) floating platform at the Maritime Research Institute Netherlands (MARIN) test facility. The designs were Froude-scaled and supported a scaled version of the 5-MW National Renewable Energy Laboratory (NREL) offshore research turbine. Data from these tests has been used extensively for numerical simulation validation efforts using NREL’s computer-aided engineering software FAST and laid the foundation for UMaine’s design efforts on VolturnUS. In 2013, UMaine conducted another test campaign at MARIN using the original semi-submersible from 2011 with an improved turbine as well as a 1:50-scale model of the VolturnUS concrete semi-submersible design. The improved DeepCwind semi-submersible data is currently being utilized in the validation of a large number of other analysis codes as part of the International Energy Agency’s OC5 project. In 2015, UMaine opened its own Wind/Wave test facility, the Alfond Wind/Wave Ocean Engineering Laboratory (W2). Utilizing this new facility, UMaine tested the 1:50-scale model DeepCwind semi-submersible, repeating the tests from MARIN, to validate the experimental equipment and procedures as well as demonstrate the capability of the W2. In 2016 UMaine carried out testing of a 1:52-scale model of the 100% design of the VolturnUS with a 6-MW topside as a final design validation to support the US Department of Energy-supported, full-scale Aqua Ventus demonstration project scheduled to be connected to the grid in 2019. A newly designed 6-MW scale model turbine was used in this test and the performance-matched turbine design methodology is described. Selected results from the test campaign and preliminary numerical comparisons are discussed as well as key lessons learned from the model test campaigns are presented.

17 WIND ENERGY↗

Pyrotechnic hazards classification and evaluation program. Phase 3, segments 1-4: Investigation of sensitivity test methods and procedures for pyrotechnic hazards evaluation and classification, part A

The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.

Source record↗

The detection of fatigue cracks by nondestructive test methods

X-radiographic, penetrant, ultrasonic, and eddy current techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 1.27 to 0.018 cm and in depth from 0.451 to 0.003 cm. Specimen thicknesses were nominally 0.152 and 0.532 cm. Specimens were evaluated in the 'as-milled' surface condition, in the etched surface condition, and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test evaluations were compared with actual crack size obtained by analysis of the fractured specimens. Inspection data were then analyzed to provide a statistical basis for determining the threshold crack detection sensitivity for each of the inspection techniques at a 95% probability and 95% confidence level.

Rummel, W. D.↗

Comparison of CO 2 Detection Methods Tested in Shallow Groundwater Monitoring Wells at a Geological Sequestration Site

The geological storage of anthropogenic carbon dioxide (CO 2 ) is one method of reducing the amount of CO 2 released into the atmosphere. Monitoring programs typically determine baseline conditions in surface and near-surface environments before, during, and after CO 2 injection to evaluate if impacts related to injection have occurred. Because CO 2 concentrations in groundwater fluctuate naturally due to complex geochemical and geomicrobiologicalinteractions, a clear understanding of the baseline behavior of CO 2 in groundwater near injection sites is important. Numerous ways of measuring aqueous CO 2 in the field and lab are currently used, but most methods have significant shortcomings (e.g., are tedious, lengthy, have interferences, or have significant lag time before a result is determined). In this study, we examined the effectiveness of two novel CO 2 detection methods and their ability to rapidly detect CO2in shallow groundwater monitoring wells associated with the Illinois Basin –Decatur Project geological sequestration site. The CarboQC beverage carbonation meter was used to measure the concentration of CO 2 in water by monitoring temperature and pressure changes and calculating the PCO 2 from the ideal gas law. Additionally, a non-dispersive infrared (NDIR) CO< sub>2 sensor enclosed in a gas-permeable, water-impermeable membrane measured CO2by determining an equilibrium concentration. Results showed that the CarboQC method provided rapid (< 3 min) and repeatable results under field conditions within a measured concentration range of 15 –125 mg/L CO 2 . The NDIR sensor results correlated well (r 2 = 0.93) with the CarboQC data, but CO 2 equilibration required at least 15 minutes, making the method somewhat less desirable under field conditions. In contrast, NDIR-based sensors have a greater potential for long-term deployment. Both systems are adaptable to in-line groundwater sampling methods. Other specific advantages and disadvantages associated with the two approaches, and anomalies associated with specific samples, are discussed in greater detail in this poster.

54 ENVIRONMENTAL SCIENCES↗

Accelerated/abbreviated test methods for predicting life of solar cell encapsulants to Jet Propulsion Laboratory California Institute of Technology for the encapsulation task of the low-cost solar array project

An important principle is that encapsulants should be tested in a total array system allowing realistic interaction of components. Therefore, micromodule test specimens were fabricated with a variety of encapsulants, substrates, and types of circuitry. One common failure mode was corrosion of circuitry and solar cell metallization due to moisture penetration. Another was darkening and/or opacification of encapsulant. A test program plan was proposed. It includes multicondition accelerated exposure. Another method was hyperaccelerated photochemical exposure using a solar concentrator. It simulates 20 year of sunlight exposure in a short period of one to two weeks. The study was beneficial in identifying some cost effective encapsulants and array designs.

Kolyer, J. M.↗

Comparison of Infiltration Test Methods for Soil Health Assessment

Infiltration rate (IR) has been commonly used as a metric to evaluate soil quality and health. For the USDA Soil Quality Test Kit, a 15-cm (6-in) diameter (ID) cylinder is used to measure IR with 444 cm 3 (equivalent to 2.54 cm or 1 in) of water while other standard IR procedures require substantially larger volumes of water. The general objective of this study was to compare different methods for IR measurement. Using three replications, IR measurements were conducted along a 9-m (27-ft) long transect in two different soil types by the double-ring infiltrometer (DRI) using 25- and 50-cm (10-and 20-in, respectively) cylinders, single-ring infiltrometer (SRI) using 25- and 50-cm cylinders, Cornell sprinkle infiltrometer (CSI) using a 24.1-cm (9.5-in) cylinder, the USDA recommended procedure using a 15-cm diameter cylinder (hereafter referred to as USDA-15 method), and a modified USDA method using a 24.1-cm diameter cylinder. Although the USDA-15 method is simple and requires a small amount of water, based on high variability among replications and significant reduction in IR during early stages of water entry into the soil, the procedure does not offer an accurate estimate of the soil infiltration potential. The CSI procedure was reproducible, but it is more cumbersome to perform than other methods. The DRI, SRI, and CSI methods required a much greater volume of water than the USDA-15 method but produced results that are more consistent. The most consistent results were obtained by the CSI and DRI methods. The modified USDA method results were similar to the SRI method and were an improvement over the original USDA-15 method. For assessing soil health, additional investigations should be conducted to evaluate a modified version of the USDA procedure using a larger cylinder.

54 ENVIRONMENTAL SCIENCES↗

Practical flight test method for determining reciprocating engine cooling requirements

It is pointed out that efficient and effective cooling of air-cooled reciprocating aircraft engines is a continuing problem for the general aviation industry. Miley et al. (1981) have reported results of a study regarding the controlling variables for cooling and installation aerodynamics. The present investigation is concerned with experimental methods which were developed to determine cooling requirements of an instrumented prototype or production aircraft, taking into account a flight test procedure which has been refined and further verified with additional testing. It is shown that this test procedure represents a straightforward means of determining cooling requirements with minimal instrumentation. Attention is given to some background information, the development history of the NACA cooling correlation method, and the proposed modification of the NACA cooling correlation.

Ward, D. T.↗

The detection of fatigue cracks by nondestructive testing methods

X-radiographic penetrant, ultrasonic, eddy current, holographic, and acoustic emission techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 0.500 inch (1.27 cm) to 0.007 inch (0.018 cm) and in depth from 0.178 inch (0.451 cm) and 0.001 inch (0.003 cm). Specimen thicknesses were nominally 0.060 inch (0.152 cm) and 0.210 inch (0.532 cm) and surface finishes were nominally 32 and 125 rms and 64 and 200 rms respectively. Specimens were evaluated in the as-milled surface condition, in the chemically milled surface condition and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test (NDT) evaluations were compared with actual crack size obtained by measurement of the fractured specimens. Inspection data was then analyzed to provide a statistical basis for determinating the threshold crack detection sensitivity (the largest crack size that would be missed) for each of the inspection techniques at a 95% probability and 95% confidence level.

Rummel, W. D.↗

A New Test Method for Material Flammability Assessment in Microgravity and Extraterrestrial Environments

The standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) is modified to provide a bench-scale test environment that simulates the low velocity buoyant or ventilation flow generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire (stagnation flow) configuration. For a fixed radiant flux, ignition delay times for characterization material PMMA are shown to decrease by a factor of three at low stretch, demonstrating that ignition delay times determined from normal cone tests significantly underestimate the risk in microgravity. The critical heat flux for ignition is found to be lowered at low stretch as the convective cooling is reduced. At the limit of no stretch, any heat flux that exceeds the surface radiative loss at the surface ignition temperature is sufficient for ignition. Regression rates for PMMA increase with heat flux and stretch rate, but regression rates are much more sensitive to heat flux at the low stretch rates, where a modest increase in heat flux of 25 kW/m2 increases the burning rates by an order of magnitude. The global equivalence ratio of these flames is very fuel rich, and the quantity of CO produced in this configuration is significantly higher than standard cone tests. These results [2] demonstrate the ELSA apparatus allows us to conduct normal gravity experiments that accurately and quantifiably evaluate a material s flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. These results also demonstrate that current NASA STD 6001 Test 2 (standard cone) is not conservative since it evaluates materials flammability with a much higher inherent buoyant convective flow.

Olson, S. L.↗

Test Method Variability in Slow Crack Growth Properties of Sealing Glasses

The crack growth properties of several sealing glasses were measured by using constant stress rate testing in ~2 and 95 percent RH (relative humidity). Crack growth parameters measured in high humidity are systematically smaller (n and B) than those measured in low humidity, and crack velocities for dry environments are ~100x lower than for wet environments. The crack velocity is very sensitive to small changes in RH at low RH. Biaxial and uniaxial stress states produced similar parameters. Confidence intervals on crack growth parameters that were estimated from propagation of errors solutions were comparable to those from Monte Carlo simulation. Use of scratch-like and indentation flaws produced similar crack growth parameters when residual stresses were considered.

Salem, J. A.↗

Test Methods and Analysis of Anomalous Charging Currents in Polymer Tantalum Capacitors

Due to dry environments, anomalous charging currents (ACC) in polymer tantalum capacitors (PTC) could cause malfunctions or failures in space systems. Currently, there is no standard metric to assess this effect, and factors affecting ACC are not well understood. This paper discusses the benefits and drawbacks of different methods used to reveal ACC including constant voltage ramp and constant current stress and suggest a power surge testing (PST) as a procedure for screening and qualification of PTCs for space applications. The suggested test is similar to the surge current testing that is currently used for MnO2 tantalum capacitors but assures dissipation of high power in the part throughout testing. Using various types of capacitors, the reproducibility of test results for different manufacturing lots of PTCs and from sample to sample within a lot were estimated. The impact of moisture content, test temperature, stress voltages, and preconditioning were assessed. Thermal effects associated with ACC and the possibility of catastrophic failures were studied experimentally using an IR camera and calculated at adiabatic heating conditions. Possible mechanisms of the phenomenon are discussed and recommendations for testing to avoid failures related to ACC are suggested.

Alexander A.Teverovsky↗

Investigation of Test Methods, Material Properties and Processes for Solar Cell Encapsulants

The evaluation of potentially useful low cost encapsulation materials is discussed. The goal is to identify, evaluate, test and recommend encapsulant materials and processes for the production of cost effective, long life solar cell modules. Technical investigations concerned the development of advanced cure chemistries for lamination type pottants; the continued evaluation of soil resistant surface treatment, and the results of an accelerated aging test program for the comparison of material stabilities. New compounds were evaluated for efficiency in curing both ethylene/vinyl acetate and ethylene/methyl acrylate pottants intended for vacuum bag lamination of solar cells. Two component aliphatic urethane casting syrups were evaluated for suitability as solar module pottants on the basis of optical, physical and fabrication characteristics.

Willis, P.↗

A Biochar Classification System and Associated Test Methods

In this chapter, a biochar classification system related to its use as soil amendment is proposed. This document builds upon previous work: “Standardized product definition and product testing guidelines for biochar that is used in soil” (IBI, 2015) (aka IBI Biochar Standards) and “Guidelines for biochar production for a sustainable production of biochar: European Biochar Certificate” (EBC, 2012-2022) (aka EBC Biochar Standards). It should be noted that the EBC guidelines constitute the basis for biochar certification through the independent government accredited inspection agency, Bio.Inspecta AG. The present document constrains its scope to materials with properties that satisfy the criteria for biochar as defined by either the IBI Biochar Standards or the EBC Standards (Annex I), as required by the current methodologies developed for accounting carbon credits associated with the biochar use in the voluntary market (e.g., Verra, Puro.Earth). The classification system envisions enabling stakeholders and commercial entities to (i) identify the most suitable biochar to fulfil the requirements for a particular soil and/or land-use, (ii) distinguish the application of biochar for specific niches (e.g., soilless agriculture), and (iii) assess the climate-impact value based on biochar properties, production efficiency, and alternative feedstock uses. It is based on the best current knowledge and will need to be improved as new data and knowledge become available in the scientific literature.

biochar, climate change impacts, soil amendment, c↗

Flight test method for the determination of reciprocating engine cooling requirements

It is pointed out that the effective cooling of aircraft reciprocating engines is still a problem area for the general aviation industry. Miley et al. (1981) have reported the results of an investigation of problems associated with cooling and installation aerodynamics. A description is given of a flight test procedure which was developed in connection with the considered investigation. It is shown that the test procedure provides valid cooling requirements data for a particular installation. The data are in terms of easily measurable parameters. The employment of the test procedure, which is based on the NACA cooling correlation method, can lead to more effective cooling installations and the solution of existing cooling problems.

Miley, S. J.↗

A polyvalent harmonic coil testing method for small-aperture magnets

A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive nondestructive test method

Various radioisotope techniques were used as diagnostic tools for determining the performance of spacecraft propulsion feed system elements. Applications were studied in four tasks. The first two required experimental testing involving the propellant liquid oxygen difluoride (OF2): the neutron activation analysis of dissolved or suspended metals, and the use of radioactive tracers to evaluate the probability of constrictions in passive components (orifices and filters) becoming clogged by matter dissolved or suspended in the OF2. The other tasks were an appraisal of the applicability of radioisotope techniques to problems arising from the exposure of components to liquid/gas combinations, and an assessment of the applicability of the techniques to other propellants.

Obrien, J. R.↗