SEARCH · Engineering Papers
Results for “TES”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.
TES for Residential Settings
The article discusses thermal energy storage approaches for residential buildings. This article addresses both brick bank storage and phase change material technologies. The energy savings and market potential of these thermal energy storage methods are reviewed as well.
THERMAplus, TES Optimized for Integration with Chillers and Heat Pumps - FINAL REPORT, SBIR Phase 1
Explore the source record for details and available documents.
First Operation of TES Microcalorimeters in Space with the Micro-X Sounding Rocket
Explore the source record for details and available documents.
Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser
Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.
Low Noise Frequency-Domain Multiplexing of TES Bolometers Using SQUIDs at Sub-Kelvin Temperature
Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of transition edge sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3 G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single-carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz1 1/2 , which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.
Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers
Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.
Technical and economic evaluation of heat transfer fluids for a TES system integrated to an advanced nuclear reactor
The utilization of thermal energy storage technology has emerged as a potential enhancement for nuclear power plants. Although nuclear energy systems possess the ability to adjust their energy output, prolonged variations in production can impact the plant's overall efficiency and economic viability. However, the nuclear industry can capitalize on thermal energy storage to bolster the power plant's economics by leveraging ancillary services and market hedging strategies. Here this research aims to advance the development of thermal energy storage for advanced nuclear reactors by assessing the thermophysical properties of various heat transfer fluids, including FLiNaK, KCl-MgCl 2 , LiCl-KCl, (LiNaK) 2 CO 3 , NaF-ZrF 4 , and KF-ZrF 4 , at temperatures ranging from 500 to 900oC. The assessment is conducted based on thermophysical correlations established in previous studies and employs figures of merit as a metric to evaluate the heat transfer performance of different salt candidates. Additionally, a cost analysis is conducted to provide an idea of the potential cost associated with each salt candidate.
Modelling and cooling power control of a TES-backed-up vapour-compression refrigeration system
Not Available
Nonlinear optimal filter technique for analyzing energy depositions in TES sensors driven into saturation
Not Available
Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors
In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.
The TES Beamline (8-BM) at NSLS-II: tender-energy spatially resolved X-ray absorption spectroscopy and X-ray fluorescence imaging
Explore the source record for details and available documents.
Design and fabrication of 90 GHz TES polarimeter detectors for the South Pole telescope
Abstract not provided
Extended line spread function of TES microcalorimeters with Au/Bi absorbers
Explore the source record for details and available documents.
Demonstration of a Full-scale Brassboard TES Microcalorimeter Array for the Athena X-IFU
Explore the source record for details and available documents.
Correcting Gain Drift in TES Detectors for Future X-ray Satellite Missions
Explore the source record for details and available documents.
DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]
This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.