At least 235 records · Page 13

Water-Cooled Optical Thermometer

Water-cooled optical probe measures temperature of nearby radiating object. Intended primarily for use in silicon-growing furnace for measuring and controlling temperatures of silicon ribbon, meniscus, cartridge surfaces, heaters, or other parts. Cooling water and flushing gas cool fiber-optic probe and keep it clean. Fiber passes thermal radiation from observed surface to measuring instrument.

Menna, A. A.↗

An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently

A gas containment vessel that is not in thermal equilibrium with the bulk gas can affect its temperature measurement. The physical nature of many gas dynamics experiments often makes the accurate measurement of temperature a challenge. The environment itself typically requires that the thermocouple be sheathed, both to protect the wires and hot junction of the instrument from their environment, and to provide a smooth, rigid surface for pressure sealing of the enclosure. However, that enclosure may also be much colder than the gas to be sensed, or vice-versa. Either way, the effect of such gradients is to potentially skew the temperature measurements themselves, since heat may then be conducted by the instrument. Thermocouple designers traditionally address this problem by insulating the sheath from the thermocouple leads and hot junction as much as possible. The thermocouple leads are typically packed in a ceramic powder inside the sheath, protecting them somewhat from temperature gradients along the sheath, but there is no effective mechanism to shield the sheath from the enclosure body itself. Standard practice dictates that thermocouples be used in installations that do not present large thermal gradients along the probe. If this conduction dominates heat transfer near the tip of the probe, then temperature measurements may be expected to be skewed. While the same problem may be experienced in the measurement of temperature at various points within a solid in a gradient, it tends to be aggravated in the measurements of gas temperature, since heat transfer dependent on convection is often less efficient than conduction along the thermocouple. The proposed solution is an inefficient fin thermocouple probe. Conventional wisdom suggests that in many experiments where gas flows through an enclosure (e.g., flow in pipe, manifold, nozzle, etc.), the thermocouple be introduced flush to the surface, so as not to interfere with the flow. In practice, however, many such experiments take place where the flow is already turbulent, so that a protruding thermocouple probe has a negligible effect on the flow characteristics. The key question then becomes just how far into the flow should a thermocouple protrude in order to properly sense the gas temperature at that point. Modeling the thermocouple as an "inefficient fin" directly addresses this question. The appropriate assumptions in this case are: one-dimensional conduction along the fin; steady-state, constant, and homogeneous thermal conductivity; negligible radiation; and a uniform, constant heat transfer coefficient over the probe surface. It is noted that the nature of the ceramic-filled probe makes the key assumption of homogeneous thermal conductivity that much more conservative.

Lemieux, Patrick↗

Atmospheric Dynamics on Venus, Jupiter, and Saturn: An Observational and Analytical Study

Determining the static stability of Jupiter's atmosphere below the visible cloud levels is important for understanding the dynamical modes by which energy and momentum are transported through Jupiter's deep troposphere. The Galileo Probe Atmospheric Structure Investigation (ASI) employed pressure and temperature sensors to directly measure these state variables during the parachute-descent phase, which started at a pressure (p) of 0.4 bars and ended at p= 22 bars. The internal temperature of the probe underwent large temperature fluctuations which significantly exceeded design specifications. Corrections for these anomalous interior temperatures have been evaluated based on laboratory data acquired after the mission using the flight spare hardware. The corrections to the pressure sensor readings was particularly large and the uncertainties in the atmospheric pressures derived from the p sensor measurements may still be significant. We have sought to estimate the formal uncertainties in the static stability derived from the p and T sensor measurements directly and to devise means of assessing the static stability of Jupiter's atmosphere which do not rely on the p sensor data.

Bridger, Alison↗

A new method for in situ electron temperature determinations from plasma wave phenomena

A discrepancy has been reported between the values of the electron temperature t sub e deduced from satellite electrostatic probe measurements and ground based radar backscatter measurements. This discrepancy (radar backscatter temperature less than the probe temperature) is not present when the probe experiment is flown on a rocket to lower altitudes but reappears when the rocket probe attains higher altitudes. There is a need for an independent radio wave method for making in-situ t sub e measurements in order to help resolve this problem. A new method of determining t sub e from the satellite resonant phenomena is presented. It is based on the splitting (observed at high latitudes) of the diffuse resonance which occurs at the frequency f sub d1 between f sub h and 2 f sub h. The advantage of this method over the other methods involving ionospheric resonances is the simplicity of the required calculations. There is, however, the limitation of plasma conditions where the f sub d1 resonance can be observed and the limitation to mid-to-high latitudes where the splitting is observed.

Oya, H.↗

Plume characteristics of MPD thrusters: A preliminary examination

A diagnostics facility for MPD thruster plume measurements was built and is currently undergoing testing. The facility includes electrostatic probes for electron temperature and density measurements, Hall probes for magnetic field and current distribution mapping, and an imaging system to establish the global distribution of plasma species. Preliminary results for MPD thrusters operated at power levels between 30 and 60 kW with solenoidal applied magnetic fields show that the electron density decreases exponentially from 1x10(2) to 2x10(18)/cu m over the first 30 cm of the expansion, while the electron temperature distribution is relatively uniform, decreasing from approximately 2.5 eV to 1.5 eV over the same distance. The radiant intensity of the ArII 4879 A line emission also decays exponentially. Current distribution measurements indicate that a significant fraction of the discharge current is blown into the plume region, and that its distribution depends on the magnitudes of both the discharge current and the applied magnetic field.

Myers, Roger M.↗

Plume characteristics of MPD thrusters - A preliminary examination

A diagnostics facility for MPD thruster plume measurements has been built and is currently undergoing testing. The facility includes electrostatic probes for electron temperature and density measurements, Hall probes for magnetic field and current distribution mapping, and an imaging system to establish the global distribution of plasma species. Preliminary results for MPD thrusters operated at power levels between 30 and 60 kW with solenoidal applied magnetic fields show that the electron density decreases exponentially from 1 x 10 to the 20th/cu m to 2 x 10 to the 18th/cu m over the first 30 cm of the expansion, while the electron temperature distribution is relatively uniform, decreasing from approximately 2.5 eV to 1.5 eV over the same distance. The radiant intensity of the ArII 4879 A line emission follows similar patterns. Current distribution measurements indicate that significant fraction of the discharge current is blown into the plume region, and that its distribution depends on the magnitudes of both the discharge current and the applied magnetic field.

Myers, R. M.↗

A compact battery powered digital thermometer

Development of thermometer to provide quick and accurate temperature readings using thermal resistance probe as temperature-to-resistance transducer is discussed. Details of construction and operations are described. Illustration of circuit and components is provided.

Zivley, G.↗

Experimental Techniques Verified for Determining Yield and Flow Surfaces

Structural components in aircraft engines are subjected to multiaxial loads when in service. For such components, life prediction methodologies are dependent on the accuracy of the constitutive models that determine the elastic and inelastic portions of a loading cycle. A threshold surface (such as a yield surface) is customarily used to differentiate between reversible and irreversible flow. For elastoplastic materials, a yield surface can be used to delimit the elastic region in a given stress space. The concept of a yield surface is central to the mathematical formulation of a classical plasticity theory, but at elevated temperatures, material response can be highly time dependent. Thus, viscoplastic theories have been developed to account for this time dependency. Since the key to many of these theories is experimental validation, the objective of this work (refs. 1 and 2) at the NASA Lewis Research Center was to verify that current laboratory techniques and equipment are sufficient to determine flow surfaces at elevated temperatures. By probing many times in the axial-torsional stress space, we could define the yield and flow surfaces. A small offset definition of yield (10 me) was used to delineate the boundary between reversible and irreversible behavior so that the material state remained essentially unchanged and multiple probes could be done on the same specimen. The strain was measured with an off-the-shelf multiaxial extensometer that could measure the axial and torsional strains over a wide range of temperatures. The accuracy and resolution of this extensometer was verified by comparing its data with strain gauge data at room temperature. The extensometer was found to have sufficient resolution for these experiments. In addition, the amount of crosstalk (i.e., the accumulation of apparent strain in one direction when strain in the other direction is applied) was found to be negligible. Tubular specimens were induction heated to determine the flow surfaces at elevated temperatures. The heating system induced a large amount of noise in the data. By reducing thermal fluctuations and using appropriate data averaging schemes, we could render the noise inconsequential. Thus, accurate and reproducible flow surfaces (see the figure) could be obtained.

Lerch, Brad A.↗

Atmosphere structure instruments on the four Pioneer Venus entry probes

Measurements of temperature, pressure, and deceleration during descent, and of deceleration during high speed entry of the four Pioneer Venus entry probes were used to define the structure, and differences in structure of the atmosphere of Venus at the four widely separated entry sites. This paper describes the sensors and steps taken to realize highly accurate measurements in the design and selection of the sensors and analog electronics.

Seiff, A.↗

Total Temperature Measurements using a Rearward Facing Probe in Supercooled Liquid Droplet and Ice Crystal Clouds

This paper presents an analysis of local total temperature and humidity experimental measurement taken in atmospheric ice cloud flows. The measurements were obtained in a series of tests in NASA's Propulsion Systems Laboratory. The probe used in the tests is referred to as the Rearward Facing Probe which was designed to mitigate the contamination effects of ice accretion and ingestion into the probe. The data provided important insights in the interaction of the ice cloud and the atmospheric flow. For the majority of the test runs, small temperature drops in the range of 0.6 to 2.8 C and up to 1.5 g/kg of water vapor rise were found as a result of the interaction. Under certain very low temperature or high TWC conditions, the interaction with the cloud produced a warming of the airflow. A thermal model based on evaporative and convective heat transfer mechanisms between the spray droplets and the airflow showed good agreement with the experimental data. Detailed analyses of the response of the probe under various flow, thermodynamic, and cloud conditions, are provided in the paper.

ice crystal↗

Transit Thermal Control Design for Galileo Entry Probe for Planet Jupiter

A totally passive design was completed for the thermal control of the Galileo entry probe during its transit to the planet Jupiter. The design utilizes radio isotope heater units, multilayer insulation blankets and a thermal radiator in conjunction with a design conductance support structure to achieve both the required storage and critical initial planet atmosphere entry temperatures. The probe transit thermal design was completed and verified based on thermal vacuum testing of a prototype probe thermal test model.

Haverly, George C.↗

Cryogenic wind tunnels: Problems of continuous operation at low temperatures

The design of a cryogenic wind tunnel which operates continuously, and is capable of attaining transonic speeds at generating pressures of about 3 bars is described. Its stainless steel construction with inside insulation allows for very rapid temperature variations promoted by rapid changes in the liquid nitrogen flow. A comparative study of temperature measuring probes shows a good reliability of thin sheet thermocouples. To measure fluctuations, only a cold wire makes it possible to record frequencies of about 300 Hz. The use of an integral computer method makes it possible to determine the impact of the wall temperature ratio to the adiabatic wall temperature for the various parameters characterizing the boundary layer. These cases are processed with positive and negative pressure gradients.

Faulmann, D.↗

Microgravity combustion discipline working group summary of requirements for noncontact temperature measurements

Current efforts of the Microgravity Combustion Working Group are summarized and the temperature measurement requirements for the combustion studies are defined. Many of the combustion systems that are studied in the low gravity environment are near-limit systems, that is, systems that are acting near the limit of flammability in terms of oxygen concentration or fuel concentration. Systems of this type are normally weak in the sense that there is a delicate balance between the heat released in the flame and the heat required to sustain the flame. Intrusive or perturbative temperature measurement probes can be inaccurate in these situations and in the limiting case extinguish the flame. Noncontact techniques then become the only way to obtain the required measurements. Noncontact measurement requirements for each of the three thermodynamic phases are described in terms of spatial and temporal resolution and temperature range.

Sacksteder, Kurt↗