Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Biospecimen Retrieval from NASA's Rodent Research-1: Maximizing Science Return from Flight Missions

Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed to support long duration missions on the International Space Station. After 37 days in microgravity twenty mice were euthanized and frozen on orbit. Upon return to Earth the carcasses were dissected and yielded 32 different types of tissues from each mouse and over 3200 tissue aliquots. Many tissues were distributed to the Space Life and Physical Sciences (SLPS) Biospecimen Sharing Program (BSP) Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). A second round of dissections was performed to collect additional tissues from the remaining carcasses thawed for a second time for additional BSP PIs. Tissues retrieved included vaginal walls, aorta, pelvis, brown adipose tissue, tail, spine and forearms. Although the analyses are still in progress, some of the PIs have reported that the quality of the tissues was acceptable for their study. In a separate experiment we tested the RNA quality of the tissues that were dissected from frozen carcasses that were subjected to euthanasia, freezing, first and second thaw dissections. Timelines simulated the on-orbit RR-1 procedures to assess the quality of the tissues retrieved from the second thaw dissections. We analyzed the RIN values of select tissues including kidney, brain, white adipose tissue (WAT) and brown adipose tissue (BAT). Overall the RIN values from the second thaw were lower compared to those from the first by about a half unit; however, the tissues yielded RNA that are acceptable quality for some quantitative gene expression assays. Interestingly, RIN values of brain tissues were 8.4+/-0.6 and 7.9+/-0.7 from first and second round dissections, respectively (n=5). Kidney and WAT yielded RIN values less than 8 but they can still be used for qPCR. BAT yielded higher quality RNA (8.2+/-0.5) than WAT (5.22+/-0.9), possibly due to the high fat content. Together, these data show that select tissues can be utilized for gene expression studies even if they are retrieved from carcasses that were subjected to at least two freezing and thawing processes; this further expands science return from valuable and infrequent rodent experiments in space.

rodent↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗

Biospecimen Retrieval from NASA's Rodent Research-1: Maximizing Science Return from Flight Missions

Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed to support long duration missions on the International Space Station. After 37 days in microgravity twenty mice were euthanized and frozen on orbit. Upon return to Earth the carcasses were dissected and yielded 32 different types of tissues from each mouse and over 3200 tissue aliquots. Many tissues were distributed to the Space Life and Physical Sciences (SLPS) Biospecimen Sharing Program (BSP) Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). A second round of dissections was performed to collect additional tissues from the remaining carcasses thawed for a second time for additional BSP PIs. Tissues retrieved included vaginal walls, aorta, pelvis, brown adipose tissue, tail, spine and forearms. Although the analyses are still in progress, some of the PIs have reported that the quality of the tissues was acceptable for their study. In a separate experiment we tested the RNA quality of the tissues that were dissected from frozen carcasses that were subjected to euthanasia, freezing, first and second thaw dissections. Timelines simulated the on-orbit RR-1 procedures to assess the quality of the tissues retrieved from the second thaw dissections. We analyzed the RIN values of select tissues including kidney, brain, white adipose tissue (WAT) and brown adipose tissue (BAT). Overall the RIN values from the second thaw were lower compared to those from the first by about a half unit; however, the tissues yielded RNA that are acceptable quality for some quantitative gene expression assays. Interestingly, RIN values of brain tissues were 8.4+/-0.6 and 7.9+/-0.7 from first and second round dissections, respectively (n5). Kidney and WAT yielded RIN values less than 8 but they can still be used for qPCR. BAT yielded higher quality RNA (8.2+/-0.5) than WAT (5.2+/-20.9), possibly due to the high fat content. Together, these data show that select tissues can be utilized for gene expression studies even if they are retrieved from carcasses that were subjected to at least two freezing and thawing processes; this further expands science return from valuable and infrequent rodent experiments in space.

rodents↗

Polarimetry and Flux Distribution in the Debris Disk Around HD 32297

We present high-contrast angular differential imaging (ADI) observations of the debris disk around HD32297 in H-band, as well as the first polarimetric images for this system in polarized differential imaging (PDI) mode with Subaru/HICIAO. In ADI, we detect the nearly edge-on disk at > or = 5(sigma) levels from approx. 0.45" to approx.1.7" (50-192AU) from the star and recover the spine deviation from the midplane already found in previous works. We also find for the first time imaging and surface brightness (SB) indications for the presence of a gapped structure on both sides of the disk at distances of approx. 0.75" (NE side) and approx. 0.65" (SW side). Global forward-modeling work delivers a best-fit model disk and well-fitting parameter intervals that essentially match previous results, with high-forward scattering grains and a ring located at 110AU. However, this single ring model cannot account for the gapped structure seen in our SB profiles. We create simple double ring models and achieve a satisfactory fit with two rings located at 60 and 95AU, respectively, low-forward scattering grains and very sharp inner slopes. In polarized light we retrieve the disk extending from approx. 0.25-1.6", although the central region is quite noisy and high S/N are only found in the range approx. 0.75-1.2". The disk is polarized in the azimuthal direction, as expected, and the departure from the midplane is also clearly observed. Evidence for a gapped scenario is not found in the PDI data. We obtain a linear polarization degree of the grains that increases from approx. 10% at 0.55" to approx. 25% at 1.6". The maximum is found at scattering angles of 90, either from the main components of the disk or from dust grains blown out to larger radii.

high-contrast angular differential imaging (ADI)↗

Risk Of Early Onset Osteoporosis Due To Spaceflight

Bone minerals decline in microgravity, and bone mineral density (BMD) losses of approximately -1 to -1.5% per month were calculated for astronauts serving on long-duration missions prior to 2009. It is unclear whether BMD losses will stabilize with time in space, or continue to diminish with time. In addition, it is unknown if fractional gravity, present on the moon and Mars, will mitigate the mineral loss. Clinicians diagnose osteoporosis in premenopausal females and males younger than 50 years on the basis of BMD T-scores < -2.5 (hip and lumbar spine) accompanied by clinical evidence of a fragility fracture. If mission-related changes to the skeleton cannot be corrected by rehabilitation after the mission, crewmembers could be at risk for premature osteoporosis-related fractures in later life. To mitigate this risk it is necessary to understand the dynamics underlying the BMD changes that occur in microgravity, to monitor for the persistence of changes after space flight, and to evaluate if and how current and future osteoporosis treatments might be used to mitigate the risk of long-term skeletal problems in astronauts.

Sibonga, Jean↗

GONG Catalog of Solar Filament Oscillations Near Solar Maximum

We have cataloged 196 filament oscillations from the Global Oscillation Network Group Hα network data during several months near the maximum of solar cycle 24 (2014 January–June). Selected examples from the catalog are described in detail, along with our statistical analyses of all events. Oscillations were classified according to their velocity amplitude: 106 small-amplitude oscillations (SAOs), with velocities <10 km s-1, and 90 large-amplitude oscillations (LAOs), with velocities >10 km s-1. Both SAOs and LAOs are common, with one event of each class every two days on the visible side of the Sun. For nearly half of the events, we identified their apparent trigger. The period distribution has a mean value of 58 ± 15 minutes for both types of oscillations. The distribution of the damping time per period peaks at τ/P = 1.75 and 1.25 for SAOs and LAOs, respectively. We confirmed that LAO damping rates depend nonlinearly on the oscillation velocity. The angle between the direction of motion and the filament spine has a distribution centered at 27° for all filament types. This angle agrees with the observed direction of filament-channel magnetic fields, indicating that most of the cataloged events are longitudinal (i.e., undergo field-aligned motions). We applied seismology to determine the average radius of curvature in the magnetic dips, R ≈ 89 Mm, and the average minimum magnetic field strength, B ≈ 16 G. The catalog is available to the community online and is intended to be expanded to cover at least 1 solar cycle.

Filaments↗

Safe, High Power/Voltage Battery Module Design Challenges

NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.

Thermal runaway↗

Multiwavelength Study of Equatorial Coronal-Hole Jets

Jets (transient/collimated plasma ejections) occur frequently throughout the solar corona and contribute mass/energy to the corona and solar wind. By combining numerical simulations and high-resolution observations, we have made substantial progress recently on determining the energy buildup and release processes in these jets. Here we describe a study of 27 equatorial coronal-hole jets using Solar Dynamics Observatory/Atmospheric Imaging Assembly and Helioseismic and Magnetic Imager observations on 2013 June 27–28 and 2014 January 8–10. Out of 27 jets, 18 (67%) are associated with mini-filament ejections; the other nine (33%) do not show mini-filament eruptions but do exhibit mini-flare arcades and other eruptive signatures. This indicates that every jet in our sample involved a filament-channel eruption. From the complete set of events, six jets (22%) are apparently associated with tiny flux-cancellation events at the polarity inversion line, and two jets (7%) are associated with sympathetic eruptions of filaments from neighboring bright points. Potential-field extrapolations of the source-region photospheric magnetic fields reveal that all jets originated in the fan-spine topology of an embedded bipole associated with an extreme ultraviolet coronal bright point. Hence, all our jets are in agreement with the breakout model of solar eruptions. We present selected examples and discuss the implications for the jet energy buildup and initiation mechanisms.

Sun Activity↗

Analysis of Interactions Between Urban Air Mobility (UAM) Operations and Conventional Traffic in Urban Areas: Traffic Alert and Collision Avoidance System (TCAS) Study for UAM Operations

This paper presents results on potential interaction effects from UAM (Urban Air Mobility) operations integrated into current operational scenarios by evaluating if/where/how Traffic alert and Collision Avoidance System (TCAS) alerts are triggered on-board commercial aircraft. A range of operational scenarios are evaluated with combinations of UAM vehicle route, speed, altitude, and direction along the DFW (Dallas-Fort Worth) "spine route." The effect of UAM altitude uncertainty on the above is also explored. The analysis was done for both South flow and North flow configurations of DFW. When UAM operations are deterministic, no TCAS RAs (Resolution Advisories) are issued. However, UAM altitude uncertainties point out geographic areas of concern with the associated severity of interactions.

Airspace↗

First Detection of Plasmoids from Breakout Reconnection on the Sun

Transient collimated plasma ejections (jets) occur frequently throughout the solar corona, in active regions, quiet Sun, and coronal holes. Although magnetic reconnection is generally agreed to be the mechanism of energy release in jets, the factors that dictate the location and rate of reconnection remain unclear. Our previous studies demonstrated that the magnetic breakout model explains the triggering and evolution of most jets over a wide range of scales, through detailed comparisons between our numerical simulations and high-resolution observations. An alternative explanation, the resistive-kink model, invokes breakout reconnection without forming and explosively expelling a flux rope. Here we report direct observations of breakout reconnection and plasmoid formation during two jets in the fan-spine topology of an embedded bipole. For the first time, we observed the formation and evolution of multiple small plasmoids with bidirectional flows associated with fast reconnection in 3D breakout current sheets (BCSs) in the solar corona. The first narrow jet was launched by reconnection at the BCS originating at the deformed 3D null, without significant flare reconnection or a filament eruption. In contrast, the second jet and release of cool filament plasma were triggered by explosive breakout reconnection when the leading edge of the rising flux rope formed by flare reconnection beneath the filament encountered the preexisting BCS. These observations solidly support both reconnection-driven jet models: the resistive kink for the first jet, and the breakout model for the second explosive jet with a filament eruption.

Kumar, Pankaj↗

Occupant Response Analysis of a Full-Scale Crash Test of a Fokker F28 Fellowship Aircraft

In this report, the capability of component fuselage testing and finite element models (FEMs) to predict occupant injury risk when applied to full-scale aircraft crash testing was evaluated. Component level and full-scale crash tests of a Fokker-F28 aircraft were performed in conjunction with representative FEM simulations. Lumbar spine injury risk, calculated through Anthropomorphic Test Device (ATD) outputs measured in the full-scale test, was compared with predictions made by component level testing and simulations. A quantitative assessment of FEM prediction accuracy was made using the International Organization for Standardization (ISO) Technical Report (TR) 16250 curve comparison methodology. Lumbar load injury risk measured in the full-scale test configuration was found to be significantly higher than in the component tests performed. The FEM provided a closer prediction of occupant injury risk than component testing but exhibited limitations in the multi-axis load environment. This work will help inform the application of component testing and FEM simulation when used to evaluate aircraft crashworthiness.

Jacob B Putnam↗

Lunar Transient Accelerations White Paper

Recently, the United States announced a plan to return astronauts to the moon by 2024 [8]. Lunar landing (and subsequent Mars landing) architecture was not considered when the current NASA standards and vehicle design requirements for crew injury risk were developed. Therefore a gap exists in protecting the crew in planetary landing scenarios. One of the interesting aspects of this design reference mission (DRM)is the consideration of having the crew stand during dynamic phases of flight. Although this approach was contemplated for the Apollo Lunar Module, current NASA standards do not address design solutions that allow the crew to stand. Currently, NASA uses several tools and associated limits to mitigate crew injury because of dynamic loads. Some of these tools are the Brinkley Dynamic Response Criterion (BDRC) model and Hybrid III Anthropomorphic Test Devices (ATDs) [10]; and these have several limitations for assessing spaceflight loading environments, as well as specific underlying assumptions that may not be applicable in planetary landing vehicles. The BDRC is a simple lumped mass parameter model developed by the U.S. military, and has been used primarily to evaluate injury risk associated with aircraft ejection systems. The model evaluates seat accelerations in each axis to determine injury risk. Because the model treats the human-seat-restraint system as a single system, it is contingent on a restraint system and seat with similar characteristics of the original test data underlying the model. In particular, the model requires a rigid seat with a minimum natural frequency of 15Hz, minimal seat pan padding, side supports, and multipoint harness. The BDRC model uses undamped natural frequency and damping coefficients based on these requirements and any deviations may render the model injury predictions void. In lunar landing, one expects that a minimal or even no seat with minimal restraints will be employed. In this case, the original model parameters are likely to not be applicable. For capsule-based spacecraft returning crew to Earth, the Hybrid III ATD in various sizes also is used to supplement the BDRC. This analytical tool was added to address limitations in the BDRC related to spacecraft landings while wearing a pressure garment and helmet. Although the Hybrid III ATD has additional measurement capability; head, neck,and lumbar spine responses were the only metrics included because of the limitations imposed by the model.Lunar landing acceleration limits must assume the crew is standing during landing, an orientation for which we have limited data.Although the Apollo missions did employ a standing orientation for the crew, much of the data is lost. Therefore data from othersources havebeen examined to inform lunar landing acceleration limits.

Jeffrey T Somers↗

A Ring Accelerator? Unusual Jet Dynamics in the IceCube Candidate PKS 1502+106

On 2019/07/30.86853 UT, IceCube detected a high-energy astrophysical neutrino can-didate. The Flat Spectrum Radio Quasar PKS 1502+106 is located within the 50 percent uncertainty region of the event. Our analysis of 15 GHz Very Long Baseline Ar-ray (VLBA) and astrometric 8 GHz VLBA data, in a time span prior and after theIceCube event, reveals evidence for a radio ring structure which develops with time.Several arc-structures evolve perpendicular to the jet ridge line. We find evidence forprecession of a curved jet based on kinematic modelling and a periodicity analysis.An outflowing broad line region (BLR) based on the C IV line emission (Sloan Dig-ital Sky Survey, SDSS) is found. We attribute the atypical ring to an interaction ofthe precessing jet with the outflowing material.We discuss our findings in thecontext of a spine-sheath scenario where the ring reveals the sheath andits interaction with the surroundings (NLR clouds).We find that the radioemission is correlated with theγ-ray emission, with radio lagging theγ-rays. Basedon theγ-ray variability timescale, we constrain theγ-ray emission zone to the BLR(30-200rg) and within the jet launching region. We discuss that the outflowing BLRprovides the external radiation field forγ-ray production via external Compton scat-tering.The neutrino is most likely produced by proton-proton interactionin the blazar zone (beyond the BLR), enabled by episodic encounters ofthe jet with dense clouds, i.e. some molecular cloud in the NLR.

S Britzen↗

REACCH - Reactive Electro-Adhesive Capture ClotH Mechanism to Enable Safe Grapple of Cooperative/Non-Cooperative Space Debris

USC’s Space Engineering Research Center (SERC) and the Jet Propulsion Laboratory (JPL) have created a unique “octopus” tentacle end effector for robotic systems that uses formable electro-adhesion (EA) and Gecko adhesion capture cloth material. REACCH, or Reactive Electro-Adhesive Capture ClotH, supports soft capture of objects of any size, shape, surface finish or material on-orbit. To-date SERC/JPL have developed initial tentacles and backing spines that can control the EA/G material. Prototypes with two tentacles have been demonstrated and tested on a 3-DOF air bearing device in 1g in one plane of grip. The results show promise to further develop this new type of grappling mechanism able to make first soft contact with an object, with a technology that merges compliance and control elements for future on-orbit servicing and assembly missions. This paper presents the initial design and test results on this type of system.

Narayanan, Sriram↗

Breakout Reconnection and Eruption in a Double Null-point Topology

Basic Question: Why are some eruptions successful while others remain confined? • We analyzed an eruption associated with a C-class flare in a null-point topology (fan-spine/embedded bipole configuration) within NOAA AR 11791, embedded within a large pseudostreamer between two coronal holes. • About 4 hours prior, interchange reconnection at the null produced a faint jet and a B-class flare without any filament eruption. • Continued reconnection below the filament built a flux rope (FR) that rose slowly and later generated the C1.4 flare. The flux rope reconnected with pseudostreamer flux near inner null, producing a remote (third) ribbon at the base of the fan and partial ejection of the flux rope. • Multiple plasmoids appeared in two places: above the rising flux rope in the breakout current sheet (the deformed null), and in a vertical flare current sheet below the flux rope (quasiperiodic flare reconnection). • Weak, narrow, coronal and interplanetary Type-III radio bursts were also detected, suggesting that electron beams from the null were ejected into the heliosphere. • The partial FR ejected from the inner system encountered the overlying arcade and null of the big pseudostreamer higher in the corona and oscillated, but did not escape. • EUV and coronagraph images revealed a wave and a faint ejection from the pseudostreamer that propagated laterally southward with ~270 km s-1. • We suggest that the main factors leading to the confined filament eruption are (i) lack of significant breakout reconnection between the rising flux rope and the overlying arcade due to an unfavorable relative orientation of these flux systems; and/or (ii) insufficient free energy of the flux rope to overcome the tension forces of the overlying arcades.

J Karpen↗

Discovery of X-Ray Polarization Angle Rotation in the Jet From Blazar Mrk 421

The magnetic-field conditions in astrophysical relativistic jets can be probed by multiwavelength polarimetry, which has been recently extended to X-rays. For example, one can track how the magnetic field changes in the flow of the radiating particles by observing rotations of the electric vector position angle Ψ. Here we report the discovery of a ΨX rotation in the X-ray band in the blazar Markarian 421 at an average flux state. Across the 5 days of Imaging X-ray Polarimetry Explorer observations on 4–6 and 7–9 June 2022, ΨX rotated in total by ≥360°. Over the two respective date ranges, we find constant, within uncertainties, rotation rates (80 ± 9° per day and 91 ± 8° per day) and polarization degrees (ΠX = 10% ± 1%). Simulations of a random walk of the polarization vector indicate that it is unlikely that such rotation(s) are produced by a stochastic process. The X-ray-emitting site does not completely overlap the radio, infrared and optical emission sites, as no similar rotation of Ψ was observed in quasi-simultaneous data at longer wavelengths. We propose that the observed rotation was caused by a helical magnetic structure in the jet, illuminated in the X-rays by a localized shock propagating along this helix. The optically emitting region probably lies in a sheath surrounding an inner spine where the X-ray radiation is released.

Makarian 421↗

Risk of Bone Fracture due to Spaceflight-induced Changes to Bone

The Human Research Program (HRP) is taking a biomechanical approach to assessing subsequent fracture risk in active astronauts as a consequence of spaceflight exposure. Triennial testing of active and retired astronauts continues as Space Medicine monitors for a premature diagnosis of primary osteoporosis, which is associated with age-related bone loss and skeletal fragility. This updated 2023 Fracture Evidence Report has expanded the description of skeletal changes to capture the full effects of spaceflight on bone: • Recent analysis of fractures from health records of the full astronaut cohort, suggests an increased incidence rate of hip and spine fractures in astronauts following longer spaceflight duration flights compared to incident rates found in shorter duration flights. • Routine preflight-to-postflight surveillance by DXA (dual-energy x-ray absorptiometry) does not provide the full detection of loss and recovery in the long-duration (LD) astronaut nor the full recovery of hip trabecular bone. • The inclusion of hip quantitative computed tomography (QCT) in flight studies delineates effects of spaceflight, of countermeasures, and of post-flight recovery on cortical and trabecular bone parameters—some of which are verified predictors of hip fracture in the aged. • QCT detects and compares the distinct countermeasure effects of the pharmaceutical alendronate and of resistive exercise (on the Advanced Resistive Exercise Device, ARED) in specific cortical and trabecular bone sub-regions during spaceflight. • A published comparison of QCT-determined loss rates of hip trabecular bone in LD astronauts compared to terrestrial cohorts suggest that accelerated loss rates in trabecular volumetric BMD (vBMD) during spaceflight might be analogous to skeletal effects of accelerated loss rates in females due to menopause, potentially leading to disruptions in trabecular microarchitecture. • A dataset of finite element (FE) estimates of hip bone strength in aging terrestrial cohorts (spanning astronaut age-range) provides comparative context for changes in the FE of hip bone strength in LD astronauts, including comparison (force unit of newton) to percentiles (50th, 75th, and 100th) of sex-matched aged humans with hip fractures. • Risk of fracture, due to the mechanical overloading of bones, is being updated with IMPACT, the next-generation tool suite for probabilistic risk assessment (PRA) for exploration missions being created by the Exploration and Medical Capability Element (ExMC) at NASA. IMPACT is currently in development and will not be included in this 2024 update. The risk for fracture necessitates understanding the relationship between applied loads to bone and the biomechanical competence of bone. The Risk for Early Onset Osteoporosis focuses on the weakened condition of bone (including development of new technologies, measurements of novel skeletal attributes, translation of multiple measures to an index of bone fragility, and interpretations of data used to reflect a weakened bone), while the Risk for Fracture assesses factors that influence the probability an astronaut would encounter applied loads exceeding the biomechanical competence of bones, resulting in fracture. This Evidence Report combines the research gaps and tasks associated with both risks.

Fracture↗

Evaluation of Markerless Motion Capture for Monitoring Sensorimotor Performance

BACKGROUND Astronauts returning from long-duration exposure to microgravity frequently exhibit alterations in sensorimotor function leading to postural imbalance, impaired locomotion, and operational challenges to manual control. Mission duration and individual responses often influence both the severity of performance decrements and the variability in adaptation timelines. Postflight disruptions during functional tasks are often detected through body-worn inertial measurement unit (IMU) devices. While IMU sensors are relatively compact, the long-term wear may lead to discomfort, displacement of the sensors on the body, and restrictions in movement or crew behavior. Although IMU data offers valuable insights from a research standpoint, interpreting changes in pre- and post-flight measures can be difficult for crew support personnel beyond the research domain, which can hinder the application for medical assessments and rehabilitation. Finally, the availability of inertial sensors in-flight is limited. There is a need for unobtrusive monitoring tools to improve our ability to monitor adaptation following gravitational transitions in various postflight evaluations and rehabilitation settings. Markerless motion capture (MMC) is an evolving unobtrusive technology that builds upon decades of research with marker-based motion capture systems to provide 3D human pose estimation from multiple synchronized 2D camera views using deep learning algorithms. Markerless technology can revolutionize how data is captured pre- and post-flight and potentially in-flight during intravehicular activity by enabling pose estimation of multiple crew members from onboard camera hardware. METHODS The following presents the initial evaluation of a state-of-the-art commercial-off-the-shelf MMC system, Theia Markerless, compared to IMU devices during various ground-based functional tasks and environmental conditions. The featured functional tasks include assessments from Human Research Program (HRP) funded studies such as Sensorimotor Standard Measures and Sensorimotor Assessments. Synchronous data collected using both motion capture and IMUs are analyzed for six male and female subjects of varying anthropometry. The analysis includes limited assessments of clothing, capture volume configurations, and the tool's sensitivity to detecting performance changes after a spaceflight analog centrifuge exposure. The development of visualization tools to enhance the application of the pose estimation output is also presented. RESULTS Initial results demonstrate comparable root mean square error (RMSE) to existing literature evaluating markerless and marker-based motion capture systems. Considering the relative functional range of motion of the cervical spine, normalized error values for the markerless system’s accuracy of the head was 0.032 in pitch, 0.025 in roll, and 0.018 in yaw plane of motion across a subset of functional tasks. The raw RMSE values were 3.49, 2.25, and 2.81 degrees respectively. For the torso, results suggest normalized errors of 0.469 in pitch, 0.191 in roll, and 0.307 in yaw planes of motion and raw RMSE values of 3.52, 1.53, and 3.07 degrees respectively. The data suggests the functional demands of a particular task influences the estimation accuracy of the MMC system where more dynamic motion and cases where subjects are not upright may introduce diminished tracking accuracy. DISCUSSION The following work lays the foundation for future implementations leveraging markerless motion capture to assess the time course of recovery and provide insight for rehabilitation protocols to enhance crew readiness for the resumption of daily activities. These tools offer effective methods for anonymizing sensitive crew data, facilitating numerous applications across research, medical, and rehabilitation groups. Collaborations with the Anthropometry and Biomechanics Facility will provide further comparisons of the Markerless system to a marker-based system. ACKNOWLEDGEMENT</ This work is supported by NASA’s Exploration Systems Development Mission Directorate Mars Campaign Office Crew Health Countermeasures.

Hannah M. Weiss↗