Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Singular value decomposition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Real-space analysis of radiation-induced specific changes with independent component analysis

A method of analysis is presented that allows for the separation of specific radiation-induced changes into distinct components in real space. The method relies on independent component analysis (ICA) and can be effectively applied to electron density maps and other types of maps, provided that they can be represented as sets of numbers on a grid. Here, for glucose isomerase crystals, ICA was used in a proof-of-concept analysis to separate temperature-dependent and temperature-independent components of specific radiation-induced changes for data sets acquired from multiple crystals across multiple temperatures. ICA identified two components, with the temperature-independent component being responsible for the majority of specific radiation-induced changes at temperatures below 130 K. The patterns of specific temperature-independent radiation-induced changes suggest a contribution from the tunnelling of electron holes as a possible explanation. In the second case, where a group of 22 data sets was collected on a single thaumatin crystal, ICA was used in another type of analysis to separate specific radiation-induced effects happening on different exposure-level scales. Here, ICA identified two components of specific radiation-induced changes that likely result from radiation-induced chemical reactions progressing with different rates at different locations in the structure. In addition, ICA unexpectedly identified the radiation-damage state corresponding to reduced disulfide bridges rather than the zero-dose extrapolated state as the highest contrast structure. The application of ICA to the analysis of specific radiation-induced changes in real space and the data pre-processing for ICA that relies on singular value decomposition, which was used previously in data space to validate a two-component physical model of X-ray radiation-induced changes, are discussed in detail. This work lays a foundation for a better understanding of protein-specific radiation chemistries and provides a framework for analysing effects of specific radiation damage in crystallographic and cryo-EM experiments.

Borek, Dominika (ORCID:0000000243216253)↗

Coherency-Based Detection Algorithm for Synchrophasor Cyberattacks

The wide area monitoring system (WAMS) is critical for power system situational awareness, but represents a growing cybersecurity vulnerability. Malicious adversaries may seek to compromise one or more PMUs in order to effect control decisions that unnecessarily disrupt typical grid operations. One example of a particularly pernicious attack vector is the spoofing or replaying of a fault event using one or more compromised PMUs. This work documents the development and validation of a coherency-based cyberattack detection algorithm that integrates a sliding-window singular value decomposition (SVD) with physics-based partitioning analysis to achieve accurate classification of events. Special consideration is given to discerning a sophisticated fault-replay or fault spoofing attack from actual faults. A software-based cybersecurity testbed has been developed for rigorous testing of the algorithm. The algorithm is further validated using simulated synchrophasor datasets obtained from a MinniWECC 63-bus test system. Results show that the algorithm can successfully detect fault-replay attacks even when over half of the PMUs are compromised.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ResSR: A Computationally Efficient Residual Approach to Super-Resolving Multispectral Images

Multispectral imaging (MSI) plays a critical role in material classification, environmental monitoring, and remote sensing. However, MSI sensors typically have wavelength-dependent resolution, which limits downstream analysis. MSI super-resolution (MSI-SR) methods address this limitation by reconstructing all bands at a common high spatial resolution. Existing methods can achieve high reconstruction quality but often rely on spatially-coupled optimization or large learning-based models, leading to significant computational cost and limiting their use in large-scale or time-critical settings. In this paper, we introduce ResSR, a computationally efficient, model-based MSI-SR method that achieves high-quality reconstruction without supervised training or spatially-coupled optimization. Notably, ResSR decouples spectral and spatial processing into two sequential steps. ResSR first computes a spectrally-informed high-resolution estimate of the MSI using singular value decomposition together with a spatially-decoupled approximate forward model. It then applies a residual correction step to restore low-frequency spatial consistency while preserving high-frequency detail recovered by the spectral reconstruction. ResSR achieves comparable or improved reconstruction quality relative to existing MSI-SR methods while being

Sullivan, Haley [ORNL] (ORCID:0000000274069217)↗

Factorization-based texture segmentation

This study introduces a factorization-based approach that efficiently segments textured images. We use local spectral histograms as features, and construct an M × N feature matrix using M-dimensional feature vectors in an N-pixel image. Based on the observation that each feature can be approximated by a linear combination of several representative features, we factor the feature matrix into two matrices-one consisting of the representative features and the other containing the weights of representative features at each pixel used for linear combination. The factorization method is based on singular value decomposition and nonnegative matrix factorization. The method uses local spectral histograms to discriminate region appearances in a computationally efficient way and at the same time accurately localizes region boundaries. Finally, the experiments conducted on public segmentation data sets show the promise of this simple yet powerful approach.

97 MATHEMATICS AND COMPUTING↗

Bayesian K-SVD Using Fast Variational Inference

Recent work in signal processing in general and image processing in particular deals with sparse representation related problems. Two such problems are of paramount importance: an overriding need for designing a well-suited overcomplete dictionary containing a redundant set of atoms— i.e., basis signals—and how to find a sparse representation of a given signal with respect to the chosen dictionary. Dictionary learning techniques, among which we find the popular K-singular value decomposition algorithm, tackle these problems by adapting a dictionary to a set of training data. A common drawback of such techniques is the need for parameter-tuning. In order to overcome this limitation, we propose a fullyautomated Bayesian method that considers the uncertainty of the estimates and produces a sparse representation of the data without prior information on the number of non-zeros in each representation vector. We follow a Bayesian approach that uses a three-tiered hierarchical prior to enforce sparsity on the representations and develop an efficient variational inference framework that reduces computational complexity. Furthermore, we describe a greedy approach that speeds up the whole process. Lastly, we present experimental results that show superior performance on two different applications with real images: denoising and inpainting.

97 MATHEMATICS AND COMPUTING↗

Dynamic-Feature Extraction, Attribution and Reconstruction (DEAR) Method for Power System Model Reduction

In interconnected power systems, dynamic model reduction can be applied on generators outside the area of interest to mitigate the computational cost with transient stability studies. This paper presents an approach of deriving the reduced dynamic model of the external area based on dynamic response measurements, which comprises of three steps, dynamic-feature extraction, attribution and reconstruction (DEAR). In the DEAR approach, a feature extraction technique, such as singular value decomposition (SVD), is applied to the measured generator dynamics after a disturbance. Characteristic generators are then identified in the feature attribution step for matching the extracted dynamic features with the highest similarity, forming a suboptimal ‘basis’ of system dynamics. In the reconstruction step, generator state variables such as rotor angles and voltage magnitudes are approximated with a linear combination of the characteristic generators, resulting in a quasi-nonlinear reduced model of the original external system. Network model is un-changed in the DEAR method. Tests on several IEEE standard systems show that the proposed method gets better reduction ratio and response errors than the traditional coherency aggregation methods.

Dynamic response, model reduction, orthogonal deco↗

Fast Parallel Stochastic Subspace Algorithms for Large-Scale Ambient Oscillation Monitoring

With the installation of synchrophasors widely across the power grid, measurement-based oscillation monitoring algorithms are becoming increasingly useful in identifying the real-time oscillatory modal properties in power systems. When the number of phasor measurement unit (PMU) channels grows, the computational time of many PMU data based algorithms is dominated by the computational burden in processing large-scale dense matrices. In order to overcome this limitation, this paper presents new formulations and computational strategies for speeding up an ambient oscillation monitoring algorithm, namely, stochastic subspace identification (SSI). Based on previous work, two fast singular value decomposition (SVD) approaches are first applied to the SVD evaluation within the SSI algorithm. Next, block structures are exploited so that the large-scale dense matrix computations can be processed in parallel. This helps in memory savings as well as in overall computational time. Experimental results from three sets of archived data of the western interconnection demonstrate that the new approaches can provide significant speedups while retaining modal estimation accuracy. With proposed fast parallel algorithms, the real-time oscillation monitoring of the large-scale system using hundreds of PMU measurements becomes feasible.

97 MATHEMATICS AND COMPUTING↗

Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

59 BASIC BIOLOGICAL SCIENCES↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

A parameterization method and application in breast tomosynthesis dosimetry

Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-16A-07: Photobleaching Predicts Necrosis in Interstitial PDT

Purpose: Dosimetry for PDT has proven to be a challenge thus far, and for prediction of PDT outcome, a singlet oxygen model based on fundamental photophysical parameters has been developed. Previously, the photobleaching effect of photosensitizers was taken into account in the singlet oxygen explicit dosimetry model; here we report of direct measurements of photobleaching in the same model to assess the conditions under which implicit dosimetry using photobleaching can serve as an intermediate surrogate for PDT damage. Methods: Fluorescence spectra were measured interstitially in sensitized mouse tumors prior to after irradiation via a cylindrical diffuser. Photobleaching was determined by the relative decrease in fluorescence amplitude from the initial pre-treatment measurement. Spectra were analyzed by singular value decomposition to determine the photosensitizer concentration. Different photosensitizers were used to see the effect of photobleaching on PDT outcome and the impact of fluence on photobleaching. The drugs used were BPD (at two drug-light intervals), HPPH, and Photofrin. PDT outcome was determined by tumor necrosis radii measured upon sectioning and staining of treated tumors. Results: Post-PDT photosentizer concentrations were compared to initial pre-PDT photosensitizer concentrations, and the decrease was greater with a higher fluence measured during treatment. Furthermore, photobleaching and necrosis radius were found to be positively correlated. The relationship between photobleaching and necrosis radius is sensitizer-dependent, however the differences among sensitizers can be understood in terms of their respective photophysical parameters. Conclusions: Photobleaching is predictive of PDT outcome, but a comprehensive singlet oxygen model, has the potential to further improve the prediction of PDT outcome and the understanding of implicit dosimetry.

60 APPLIED LIFE SCIENCES↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the scattering correction of fast-ion D-alpha signal on NSTX-U

Analysis of fast-ion D-alpha (FIDA) data on National Spherical Torus Experiment-Upgrade (NSTX-U) shows that the cold Dα line contaminates the FIDA baseline. The scattered light is comparable to the FIDA emission. A scattering correction is required to extract the FIDA signal. Two methods that relate the scattered light contamination to the intensity of the cold Dα line are employed. One method uses laboratory measurements with a calibration lamp; the other method uses data acquired during plasma operation and singular value decomposition analysis. After correction, both the FIDA spectra and spatial profile are in better agreement with theoretical predictions.

Single value decomposition (SVD)↗

Pressio

Reduced-order Models (ROMs). ROMs are "compressed" approximations of high-fidelity computational models. Implementing ROM methods in production codes is typically intrusive, i.e. the native codes must be adapted and modified, with individual ROM methods reimplemented in every application code. This clearly constitutes an obstacle to users who want to use ROMs. To address this, we have developed Pressio, which is a C++ header-only ROM library that can be used by an application code in a non-intrusive fashion. The main objectives behind the design of Pressio are: (a) support for general computational models (data structures, PDE types); (b) heterogeneous hardware (CPU, GPU); (c) performance; and (d) extensibility. Using metaprogramming techniques, Pressio detects and leverages the application?s native linear algebra data structures (e.g. vector and matrix) to run the ROM methods. The application only needs to expose the velocity vector and Jacobian matrix via an adapter class. Pressio checks at compile time that the target application meets the correct API. The library is structured in several modular packages including (a) non-linear least-square solvers (e.g. Gauss-Newton with and without line-search); (b) singular value decomposition (for the computation of the ROM generalized coordinates) and (c) algebraic hyper-reduction.SAND2019-5878 M

Blonigan, Patrick↗

APPRENTICE

SF-19-096 In this software, there are multiple approaches to compute approximations to multivariate functions. This includes: (a) an approach that builds on Stieltjes process to efficiently compute the coefficients of the rational approximation, (b) an approach that is based on an optimization formulation to get pole-free coefficients of the rational approximation and (c) approaches that finds the coefficients of rational and polynomial approximations by finding the linear least-squares solution using singular value decomposition.

KRISNAMOORTHY, MOHAN↗

Pressio v.1.0

Reduced-order Models (ROMs). ROMs are "compressed" approximations of high-fidelity computational models. Implementing ROM methods in production codes is typically intrusive, i.e. the native codes must be adapted and modified, with individual ROM methods reimplemented in every application code. This clearly constitutes an obstacle to users who want to use ROMs. To address this, we have developed Pressio, which is a C++ header-only ROM library that can be used by an application code in a non-intrusive fashion. The main objectives behind the design of Pressio are: (a) support for general computational models (data structures, PDE types); (b) heterogeneous hardware (CPU, GPU); (c) performance; and (d) extensibility. Using metaprogramming techniques, Pressio detects and leverages the application?s native linear algebra data structures (e.g. vector and matrix) to run the ROM methods. The application only needs to expose the velocity vector and Jacobian matrix via an adapter class. Pressio checks at compile time that the target application meets the correct API. The library is structured in several modular packages including (a) non-linear least-square solvers (e.g. Gauss-Newton with and without line-search); (b) singular value decomposition (for the computation of the ROM generalized coordinates) and (c) algebraic hyper-reduction.SAND2019-5878 M

Blonigan, Patrick↗