Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor placement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A regression technique for evaluation and quantification for water quality parameters from remote sensing data

The paper attempts to define optical physics and/or environmental conditions under which the linear multiple-regression should be applicable. It is reported that investigation of the signal response shows that the exact solution for a number of optical physics conditions is of the same form as a linearized multiple-regression equation, even if nonlinear contributions from surface reflections, atmospheric constituents, or other water pollutants are included. Limitations on achieving this type of solution are defined. Laboratory data are used to demonstrate that the technique is applicable to water mixtures which contain constituents with both linear and nonlinear radiance gradients. Finally, it is concluded that instrument noise, ground-truth placement, and time lapse between remote sensor overpass and water sample operations are serious barriers to successful use of the technique.

Whitlock, C. H.↗

Thermal Analyzer for Planetary Soil (TAPS): an in Situ Instrument for Mineral and Volatile-element Measurements

Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm(sup 3), occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.

Gooding, J. L.↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Local Ferromagnetic Resonance Measurements of Mesoscopically Patterned Ferromagnets Using Deterministically Placed Nanodiamonds

Nitrogen-vacancy centers in diamond have recently been established as effective sensors of the magnetization dynamics in vicinal ferromagnetic materials. Here, we demonstrate sub-100-nm placement accuracy of nitrogen-vacancy-containing nanodiamonds and use these as local sensors that probe optically detected ferromagnetic resonance in mesoscopically patterned Permalloy islands. These measurements reveal variations in the ferromagnetic resonance signal at different sites on these structures with distinct behavior in the edge and the bulk of patterned features. These test measurements establish an easily implemented approach for spatially targeted measurements of spin dynamics in mesoscale ferromagnets. In principle, the methodology can also be extended to local studies of nanoscale ferromagnets, such as single magnetic nanowires and nanoparticles.

30 DIRECT ENERGY CONVERSION↗

A System Trade Study of Remote Infrared Imaging for Space Shuttle Reentry

A trade study reviewing the primary operational parameters concerning the deployment of imaging assets in support of the Hypersonic Thermodynamic Infrared Measurements (HYTHIRM) project was undertaken. The objective was to determine key variables and constraints for obtaining thermal images of the Space Shuttle orbiter during reentry. The trade study investigated the performance characteristics and operating environment of optical instrumentation that may be deployed during a HYTHIRM data collection mission, and specified contributions to the Point Spread Function. It also investigated the constraints that have to be considered in order to optimize deployment through the use of mission planning tools. These tools simulate the radiance modeling of the vehicle as well as the expected spatial resolution based on the Orbiter trajectory and placement of land based or airborne optical sensors for given Mach numbers. Lastly, this report focused on the tools and methodology that have to be in place for real-time mission planning in order to handle the myriad of variables such as trajectory ground track, weather, and instrumentation availability that may only be known in the hours prior to landing.

Schwartz, Richard J.↗

Control surface spanwise placement in active flutter suppression systems

All flutter suppression systems require sensors to detect the movement of the lifting surface and to activate a control surface according to a synthesized control law. Most of the work performed to date relates to the development of control laws based on predetermined locations of sensors and control surfaces. These locations of sensors and control surfaces are determined either arbitrarily, or by means of a trial and error procedure. The aerodynamic energy concept indicates that the sensors should be located within the activated strip. Furthermore, the best chordwise location of a sensor activating a T.E. control surface is around the 65 percent chord location. The best chordwise location for a sensor activating a L.E. surface is shown to lie upstream of the wing (around 20 percent upstream of the leading edge), or alternatively, two sensors located along the same chord should be used.

Nissim, E.↗

Vibration suppression for precision segmented reflector backup structure

An ongoing effort at the JPL on vibration suppression for the Precision Segmented Reflector backup structure is centered on the vibration damping augmentation through a system consisting of active and passive damping members. An active member is a structural member with built-in piezoelectric actuator and sensors. An efficient method was developed for optimal placement of active and passive damping members in the truss-type backup structure. A simple synergistic model between the active and passive damping was proposed based on a weighted energy dissipation criterion. A baseline passive member design with constrained viscoelastic material treatment was used as the source of passive damping.

Chen, G.-S.↗

Evaluation of an Interferometric Sensor for In-Space Detection of Gas Leaks

Space mission planning often involves long-term storage of volatile liquids or high-pressure gases. These may include cryogenic fuels and oxidizers, high-pressure gases, and life-support-critical consumables. The risk associated with the storage of fluids and gases in space systems has long been an issue and the ability to retain these fluids is often tied to mission success. A leak in the storage or distribution system can cause many different problems, including a simple, but mission endangering, loss of inventory or, in severe cases, unbalanced thrust loads on a flight vehicle. Cryogenic propellants are especially difficult to store, especially over a long duration. The propellant can boil off and be lost through the insulating walls of the tank or simple thermal cycling of the fittings, valves, and propellant feed lines may unseat seals allowing the fluid to escape. Current NASA missions call for long-duration in-space storage of propellants, oxidizers, and life support supplies. Leaks of a scale detectable through a pressure drop in the storage tank are often catastrophic and have long been the focus of ground-based mitigation efforts where redundant systems are often employed. However, there is presently no technology available for detecting and monitoring low-level, but still mission-endangering, gas leaks in space. Standard in-space gas detection methods either have a very limited pressure range over which they operate effectively or are limited to certain gases. Mass spectrometer systems are able to perform the detection tasks, but their size, mass and use of high voltage, which could potentially lead to an arc that ignites a combustible propellent, severely limit their usefulness in a space system. In this paper, we present results from testing of the light-based interferometric gas monitoring and leak detection sensor shown in Fig. 1. The output of the sensor is an interference fringe pattern that is a function of the gas density, and commensurate index of refraction, in the sample region. Changes in the density of gas cause the interference fringes to move across a photodiode detector, providing a temporal history of the leak. The sensor is fiber coupled and constructed from solid optics, allowing for placement almost anywhere on the spacecraft. It is also advantageous in that it consumes very little power and does not introduce an ignition source. Data are presented demonstrating the capability of the sensor to measure density variations in different gas species. In addition, the transient response of the sensor in vacuum is demonstrated. These data extend and improve upon the results previously presented by the authors in Ref. [1].

Polzin, Kurt A.↗

Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents

A multi-analyte sensor was developed that enables simultaneous detection of rocket engine combustion-product molecules in a launch-vehicle ground test stand. The sensor was developed using a pin-printing method by incorporating multiple sensor elements on a single chip. It demonstrated accurate and sensitive detection of analytes such as carbon dioxide, carbon monoxide, kerosene, isopropanol, and ethylene from a single measurement. The use of pin-printing technology enables high-volume fabrication of the sensor chip, which will ultimately eliminate the need for individual sensor calibration since many identical sensors are made in one batch. Tests were performed using a single-sensor chip attached to a fiber-optic bundle. The use of a fiber bundle allows placement of the opto-electronic readout device at a place remote from the test stand. The sensors are rugged for operation in harsh environments.

Goswami, Kisholoy↗

Field and Modeling Perspectives

The bifacial single-axis tracking field at NREL has been collecting now data for 3 years, for different bifacial PV technologies. Through this presentation, we will see the overall bifacial gains from the various PERCs and SHJ in the field, which are compared to their monofacial counterpart technologies, as well as degradations and investigation into some of the rows performance losses. We will present results on best sensor locations, as well as preliminary results on albedo material placement optimization and agrivoltaics also explored on this site.

agriPV↗

The sun-tracking control of solar collectors using high-performance step motors

Sun-tracking solar energy-focusing devices involving a central receiver, thermionic conversion, or a distributed solar thermal collector system are described. The Perkins solar collector uses a fixed focal point about which an 18 m-diameter parabolic dish moves on tracks. The elevation axis also moves on a circular track. A microprocessor manipulates sun sensor information and sun ephemeris data to ensure correct placement. Stepper motors are digital devices which provide direct interface with digital electronics and a wide dynamic range, and could easily be associated with the microprocessors. Design philosophy, performance criteria, wind load analysis, and control system requirements are also discussed.

Hughes, R. O.↗

Stepwise Assembly of Turn‐on Fluorescence Sensors in Multicomponent Metal–Organic Frameworks for in Vitro Cyanide Detection

Abstract The controlled synthesis of multicomponent metal–organic frameworks (MOFs) allows for the precise placement of multiple cooperative functional groups within a framework, leading to emergent synergistic effects. Herein, we demonstrate that turn‐on fluorescence sensors can be assembled by combining a fluorophore and a recognition moiety within a complex cavity of a multicomponent MOF. An anthracene‐based fluorescent linker and a hemicyanine‐containing CN − ‐responsive linker were sequentially installed into the lattice of PCN‐700. The selective binding of CN − to hemicyanine inhibited the energy transfer between the two moieties, resulting in a fluorescence turn‐on effect. Taking advantage of the high tunability of the MOF platform, the ratio between anthracene and the hemicyanine moiety could be fine‐tuned in order to maximize the sensitivity of the overall framework. The optimized MOF‐sensor had a CN − ‐detection limit of 0.05 μ m , which is much lower than traditional CN − fluorescent sensors (about 0.2 μ m ).

Li, Jialuo↗

Multifunctional Fiber-Reinforced Polymer Composites for Damage Detection and Memory

Self-structural health monitoring (SHM) functionalities for fiber-reinforced polymer composites have become highly sought after to ensure the structural safety of newly advancing components in the automotive, civil, mechanical, and aerospace industries. This paper introduces a self-damage detection and memory (SDDM) hybrid composite material, where the structural carbon fiber tow is transformed into a piezoresistive sensor network, and the structural glass fiber operates as electrical insulation. In this study, SDDM specimens were fabricated, and tensile and impact tests were performed. The tensile tests of SDDM specimens find two distinct loading peaks: first where the carbon fiber fails, and second where the glass fiber fails. A linear correlation was observed between the carbon fiber resistance and composite strain up to a threshold, beyond which a sharp nonlinear increase in resistance occurred. The resistance then approached infinity, coinciding with the first loading peak and failure of the carbon fiber elements. This demonstrates the potential for a damage early warning threshold. Additionally, the effect of stitching the sensor tow in a zig-zag pattern over a large area was investigated using tailored fiber placement (TFP) of 1-loop, 3-loop, and 5-loop specimens. Tensile testing found that increasing the number of loops improved the sensor’s accuracy for strain sensing. Furthermore, impact tests were conducted, and as the impact energy progressively increased, the sensor resistance permanently increased. This illustrates a capability for self-memory of microdamage throughout the life cycle of the structure, potentially useful for predicting the remaining life of the composite.

Demo, Luke B. (ORCID:0000000208806522)↗

Data Input, Processing and Presentation

The problems of data acquisition, processing and display are investigated in the case of a helicopter rotor balance. The types of sensors to be employed are discussed in addition to their placement and application in wind tunnel trials. Finally, the equipment for data processing, evaluation and storage are presented with a description of methods.

Langer, H. J.↗

Manufacturing of Smart Structures Using Fiber Placement Manufacturing Processes

Smart structures research and development, with the ultimate aim of rapid commercial and military production of these structures, are at the forefront of the Synthesis and Processing of Intelligent Cost-Effective Structures (SPICES) program. As part of this ARPA-sponsored program, MDA-E is using fiber placement processes to manufacture integrated smart structure systems. These systems comprise advanced composite structures with embedded fiber optic sensors, shape memory alloys, piezoelectric actuators, and miniature accelerometers. Cost-effective approaches and solutions to smart material synthesis in the fiber-placement process, based upon integrated product development, are discussed herein.

Thomas, Matthew M.↗

SCAMP: Rapid Focused Sonic Boom Waypoint Flight Planning Methods, Execution, and Results

Successful execution of the flight phase of the Superboom Caustic Analysis and Measurement Project (SCAMP) required accurate placement of focused sonic booms on an array of prepositioned ground sensors. While the array was spread over a 10,000-ft-long area, this is a relatively small region when considering the speed of a supersonic aircraft and sonic boom ray path variability due to shifting atmospheric conditions and aircraft trajectories. Another requirement of the project was to determine the proper position for a microphone-equipped motorized glider to intercept the sonic boom caustic, adding critical timing to the constraints. Variability in several inputs to these calculations caused some shifts of the focus away from the optimal location. Reports of the sonic booms heard by persons positioned amongst the array were used to shift the focus closer to the optimal location for subsequent passes. This paper describes the methods and computations used to place the focused sonic boom on the SCAMP array and gives recommendations for their accurate placement by future quiet supersonic aircraft. For the SCAMP flights, 67% of the foci were placed on the ground array with measured positions within a few thousand feet of computed positions. Among those foci with large caustic elevation angles, 96% of foci were placed on the array, and measured positions were within a few hundred feet of computed positions. The motorized glider captured sonic booms on 59% of the passes when the instrumentation was operating properly.

Haering, Edward A., Jr.↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗