Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Segmented Gamma Scanner for Small Containers of Uranium Processing Waste- 12295

The Segmented Gamma Scanner (SGS) is commonly utilized in the assay of 55-gallon drums containing radioactive waste. Successfully deployed calibration methods include measurement of vertical line source standards in representative matrices and mathematical efficiency calibrations. The SGS technique can also be utilized to assay smaller containers, such as those used for criticality safety in uranium processing facilities. For such an application, a Can SGS System is aptly suited for the identification and quantification of radionuclides present in fuel processing wastes. Additionally, since the significant presence of uranium lumping can confound even a simple 'pass/fail' measurement regimen, the high-resolution gamma spectroscopy allows for the use of lump-detection techniques. In this application a lump correction is not required, but the application of a differential peak approach is used to simply identify the presence of U-235 lumps. The Can SGS is similar to current drum SGSs, but differs in the methodology for vertical segmentation. In the current drum SGS, the drum is placed on a rotator at a fixed vertical position while the detector, collimator, and transmission source are moved vertically to effect vertical segmentation. For the Can SGS, segmentation is more efficiently done by raising and lowering the rotator platform upon which the small container is positioned. This also reduces the complexity of the system mechanism. The application of the Can SGS introduces new challenges to traditional calibration and verification approaches. In this paper, we revisit SGS calibration methodology in the context of smaller waste containers, and as applied to fuel processing wastes. Specifically, we discuss solutions to the challenges introduced by requiring source standards to fit within the confines of the small containers and the unavailability of high-enriched uranium source standards. We also discuss the implementation of a previously used technique for identifying the presence of uranium lumping. The SGS technique is a well-accepted NDA technique applicable to containers of almost any size. It assumes a homogenous matrix and activity distribution throughout the entire container; an assumption that is at odds with the detection of lumps within the assay item typical of uranium-processing waste. This fact, in addition to the difficultly in constructing small reference standards of uranium-bearing materials, required the methodology used for performing an efficiency curve calibration to be altered. The solution discussed in this paper is demonstrated to provide good results for both the segment activity and full container activity when measuring heterogeneous source distributions. The application of this approach will need to be based on process knowledge of the assay items, as biases can be introduced if used with homogenous, or nearly homogenous, activity distributions. The bias will need to be quantified for each combination of container geometry and SGS scanning settings. One recommended approach for using the heterogeneous calibration discussed here is to assay each item using a homogenous calibration initially. Review of the segment activities compared to the full container activity will signal the presence of a non-uniform activity distribution as the segment activity will be grossly disproportionate to the full container activity. Upon seeing this result, the assay should either be reanalyzed or repeated using the heterogeneous calibration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Upfront Update on Barsebaeck 1-2 Reactor Internals Segmentation Project - 17382

Westinghouse is currently executing a contract, awarded in June 2015 from Barsebaeck Kraft AB, to segment all the reactor vessel (RV) internal parts in the two units 1 and 2. The scope of work covers the dismantling and segmentation of the RV internals under water, including the upfront engineering studies and equipment manufacturing and qualification. It also includes the loading of the segmented parts into waste cassettes, handling the cassettes, reactor internals sampling (73 samples), complementary water filtration system to catch the segmentation chips and contribute to maintaining water clarity during the segmentation work. Before leaving the site, the pool environment must be restored to the initial condition and all equipment will be decontaminated and shipped off site. The site work started in August 2016 with the mobilization on the Unit 2 and the actual cutting of the first component (steam dryer) started in September. Cutting will be performed with different types of Westinghouse designed cutting equipment. This paper presents the conceptual design of the reactor internals segmentation and packaging process that will be implemented at Barsebaeck, including the planning, methodology, equipment, waste management and packaging strategy. A first feedback on the site work will be provided for the segmentation of the Unit 2 reactor internals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capsule network-based semantic segmentation model for thermal anomaly identification on building envelopes

Thermography technology is widely used to inspect thermal anomalies in building façade systems. Computer vision-based techniques provide opportunities to autonomously detect such heat anomalies to significantly improve the efficiency of decision-making for building envelope retrofitting and maintenance. Here, in this work, we propose a novel Capsule Network-based deep learning model – CapsLab – that detects and identifies thermal anomalies by semantic segmentation. CapsLab is built based on our proposed prediction-tuning capsule (PT-Capsule) layer. Different from a traditional capsule layer, which consists of part-whole transformation and capsule-routing process, the proposed layer is composed of a prediction and tuning process, which helps decreasing the number of model parameters significantly. While the applicability of traditional Capsule Networks (CapsNets) has been limited to simpler tasks and smaller datasets due to their scalability issue, we can leverage the lightweight of the proposed PT-Capsule layer, and apply it to the semantic segmentation task. In this work, we also employ our previously presented performance metric, referred to as the Anomaly Identification Metric (AIM) (Kakillioglua et al. 2021), to evaluate the segmentation outputs. Traditional performance metrics do not accurately reflect the true performance of the segmentation models in thermal anomaly identification due to the high subjectivity in the annotation process and higher overlap ratio sensitivity of the standard metrics. AIM, on the other hand, is robust to these drawbacks. Experimental results show, both qualitatively and quantitatively, that our proposed segmentation method can effectively segment the thermal anomalies. Specifically, our model provides 9.38% and 13.53% improvements over the baseline model – DeepLabV3+ – based on traditional mIoU score and the AIM score, respectively, while requiring less model parameters and less computation at the same time. In addition, the scores that the AIM metric generates better align with the scores provided by building performance experts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical median narrow band for level set segmentation of cervical cell nuclei

This paper presents a novel hierarchical nuclei segmentation algorithm for isolated and overlapping cervical cells based on a narrow band level set implementation. Our method applies a new multiscale analysis algorithm to estimate the number of clusters in each image region containing cells, which turns into the input to a narrow band level set algorithm. We assess the nuclei segmentation results on three public cervical cell image databases. Overall, our segmentation method outperformed six state-of-the-art methods concerning the number of correctly segmented nuclei and the Dice coefficient reached values equal to or higher than 0.90. We also carried out classification experiments using features extracted from our segmentation results and the proposed pipeline achieved the highest average accuracy values equal to 0.89 and 0.77 for two-class and three-class problems, respectively. Furthermore, these results demonstrated the suitability of the proposed segmentation algorithm to integrate decision support systems for cervical cell screening.

47 OTHER INSTRUMENTATION↗

Segmentation method comparison for residual fiber length measurement across tiled microscopy images

Fiber length distribution (FLD), in part, governs mechanical properties in discontinuous fiber composites, yet manual measurement methods limit the high-throughput characterization needed for materials design optimization. This study compares deep learning segmentation approaches for automated FLD measurement in large-field microscopy, evaluating how method choice affects the microstructural descriptors used in structure-property-processing relationships. A critical challenge is that high-resolution microscopy images (10,000×10,000 pixels) must be tiled for deep learning analysis, fragmenting fibers at boundaries. We demonstrate that segmentation method proves crucial for measurement accuracy. For example, instance segmentation with Slicing Aided Hyper Inference (SAHI) preserves individual fiber integrity across tiles while semantic segmentation prioritizes speed. Comparing against manual measurement of extracted carbon fibers, YOLOv11-SAHI matched manual ground truth (238 μm weighted mean) with 40x speedup (4.5 vs 167 minutes per image). U-Net provides rapid quantification although it is at the cost of reduced accuracy due only reliably measuring stand-alone fibers. Our comparative analysis reveals that instance segmentation with SAHI better preserves length measurements while semantic segmentation prioritizes speed, providing empirical guidance for method selection. The characterization provides essential inputs for mechanical property prediction models and inverse design workflows, accelerating composite materials development cycles.

Additive manufacturing↗

The three-way junction structure of the HIV-1 PBS-segment binds host enzyme important for viral infectivity

HIV-1 reverse transcription initiates at the primer binding site (PBS) in the viral genomic RNA (gRNA). Although the structure of the PBS-segment undergoes substantial rearrangement upon tRNALys3 annealing, the proper folding of the PBS-segment during gRNA packaging is important as it ensures loading of beneficial host factors. DHX9/RNA helicase A (RHA) is recruited to gRNA to enhance the processivity of reverse transcriptase. Because the molecular details of the interactions have yet to be defined, we solved the solution structure of the PBS-segment preferentially bound by RHA. Evidence is provided that PBS-segment adopts a previously undefined adenosine-rich three-way junction structure encompassing the primer activation stem (PAS), tRNA-like element (TLE) and tRNA annealing arm. Disruption of the PBS-segment three-way junction structure diminished reverse transcription products and led to reduced viral infectivity. Because of the existence of the tRNA annealing arm, the TLE and PAS form a bent helical structure that undergoes shape-dependent recognition by RHA double-stranded RNA binding domain 1 (dsRBD1). Mutagenesis and phylogenetic analyses provide evidence for conservation of the PBS-segment three-way junction structure that is preferentially bound by RHA in support of efficient reverse transcription, the hallmark step of HIV-1 replication.

59 BASIC BIOLOGICAL SCIENCES↗

A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network

Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Assessment of U-Net-Based Deep Learning Models for Segmenting Microfractures and Pore Spaces in Digital Rocks

Segmentation of high-resolution X-ray microcomputed tomography (µCT) images is crucial in digital rock physics (DRP), affecting the characterization and analysis of microscale phenomena in the porous media. The complexity of geological structures and nonideal scanning conditions pose significant challenges to conventional image segmentation approaches. Motivated by the recent increasing popularity of deep learning (DL) techniques in image processing, this work undertakes a comparative study of DL models, specifically U-Net and its variants, for segmenting multiple targets with distinguished features in digital rocks, including discrete fracture networks (DFNs), pore spaces, and solid rock. Particularly, DFNs have a smaller volumetric fraction over others, bringing in a substantial challenge of imbalanced segmentation. The primary focus is to evaluate the architecture and feature enhancement strategies of various DL models, including U-Net, attention U-Net, residual U-Net, U-Net++, and residual U-Net++. The models were designed as 2.5D, utilizing a central 2D image and its two adjacent upper and lower 2D images as input to provide a pseudo-3D context. In addition, because the ground truth of segmentation was unknown for real-world digital rocks, we created a benchmark data set following the inverse operations of segmentation. The data synthesis started from the label images (i.e., solid rock, pore spaces, and DFNs), followed by simulating partial volume blurring, adding random background noise, and introducing ring artifacts to mimic real raw X-ray µCT images. The data set, which included various rock types (i.e., sandstone and artificial data), scanning resolution, and magnitudes of noise and artifacts, was divided into training and testing data sets with a 90% and 10% ratio, respectively. Moreover, in addition to the conventional pixel-wise evaluation metrics, the physics-based metric of the lattice-Boltzmann method (LBM) simulated permeability provided more comprehensive assessments. The results demonstrated that the residual connections, nested architectures, and redesigned skip connections contribute to the model performance and give the residual U-Net++ the highest accuracy. The improvements were mainly on the boundaries and small targets, especially the DFNs, which dominate the interconnectivity and therefore affect the permeability greatly. This study also rigorously evaluated the efficiency and generalization of each model, demonstrating that the sophisticated architectures achieved excellent practicability and maintained robust performance on completely unseen data, ensuring their suitability for diverse and challenging DRP applications.

58 GEOSCIENCES↗

Using AI Segmentation Models to Improve Foreign Body Detection and Triage from Ultrasound Images

Medical imaging can be a critical tool for triaging casualties in trauma situations. In remote or military medicine scenarios, triage is essential for identifying how to use limited resources or prioritize evacuation for the most serious cases. Ultrasound imaging, while portable and often available near the point of injury, can only be used for triage if images are properly acquired, interpreted, and objectively triage scored. Here, we detail how AI segmentation models can be used for improving image interpretation and objective triage evaluation for a medical application focused on foreign bodies embedded in tissues at variable distances from critical neurovascular features. Ultrasound images previously collected in a tissue phantom with or without neurovascular features were labeled with ground truth masks. These image sets were used to train two different segmentation AI frameworks: YOLOv7 and U-Net segmentation models. Overall, both approaches were successful in identifying shrapnel in the image set, with U-Net outperforming YOLOv7 for single-class segmentation. Both segmentation models were also evaluated with a more complex image set containing shrapnel, artery, vein, and nerve features. YOLOv7 obtained higher precision scores across multiple classes whereas U-Net achieved higher recall scores. Using each AI model, a triage distance metric was adapted to measure the proximity of shrapnel to the nearest neurovascular feature, with U-Net more closely mirroring the triage distances measured from ground truth labels. Overall, the segmentation AI models were successful in detecting shrapnel in ultrasound images and could allow for improved injury triage in emergency medicine scenarios.

47 OTHER INSTRUMENTATION↗

Experimental Verification of Dispersed Fringe Sensing as a Segment Phasing Technique using the Keck Telescope

Dispersed fringe sensing (DFS) is an efficient and robust method for coarse phasing of segmented primary mirrors (from one quarter of a wavelength to as much as the depth of focus of a single segment, typically several tens of microns). Unlike phasing techniques currently used for ground-based segmented telescopes, DFS does not require the use of edge sensors in order to sense changes in the relative heights of adjacent segments; this makes it particularly well suited for phasing of space-borne segmented telescopes, such as the James Webb Space Telescope. We validate DFS by using it to measure the piston errors of the segments of one of the Keck telescopes. The results agree with those of the Shack-Hartmann-based phasing scheme currently in use at Keck to within 2% over a range of initial piston errors of +/-16 (mu)m.

algorithm↗

How to Calibrate Edge Sensors on Segmented Mirror Telescopes

The next generation of large ground based telescopes use segmented mirrors. Sensors mounted on the edge of the segments measure the relative heights of the segments. The segments are actively controlled in height by three actuators per segment, but lateral motion is only passively constrained. Thus there will be some small change in the gap and shear between segments as changing telescope orientation and temperature make small distortions in the telescope structure. These "in-plane" motions place an additional performance burden on the edge sensors, and on the precision with which they must be mounted relative to the optical surface. In addition, both the scaling and offset of sensor edge height readings also vary with changes in gap.

segmented mirrors↗

1D-Convolutional Neural Network Architecture for Generalized Time-Segmentation Tasks

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D CNN architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization are described as well as the results of application to three separate arc jet data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation.

Machine learning↗

1d-Convolutional Neural Network Architecture for Generalized Time-Segmentation Tasks

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D CNN architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization are described as well as the results of application to three separate arc jet data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation.

Machine learning↗

1D-Convolutional Neural Network Architecture for Generalized Time-Segmentation Tasks

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D convolutional neural net (CNN) architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization are described as well as the results of application to three separate arc jet data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation.

Machine learning↗

1D-Convolutional Neural Network Architecture for Generalized Time-series Segmentation

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D convolutional neural net (CNN) architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization will be described as well as the results of application to three separate data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation. In all three test cases the 1D-CNN performs better than tailored integral/derivative/thresholding algorithms across a range of signal-to-noise levels.

CNN↗

1D-Convolutional Neural Network Architecture for Generalized Time-series Segmentation

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D convolutional neural net (CNN) architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization will be described as well as the results of application to three separate data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation. In all three test cases the 1D-CNN performs better than tailored integral/derivative/thresholding algorithms across a range of signal-to-noise levels.

CNN↗

Radiographic Response to Yttrium-90 Radioembolization in Anterior Versus Posterior Liver Segments

The purpose of our study was to determine if preferential radiographic tumor response occurs in tumors located in posterior versus anterior liver segments following radioembolization with yttrium-90 glass microspheres. One hundred thirty-seven patients with chemorefractory liver metastases of various primaries were treated with yttrium-90 glass microspheres. Of these, a subset analysis was performed on 89 patients who underwent 101 whole-right-lobe infusions to liver segments V, VI, VII, and VIII. Pre- and posttreatment imaging included either triphasic contrast material-enhanced CT or gadolinium-enhanced MRI. Responses to treatment were compared in anterior versus posterior right lobe lesions using both RECIST and WHO criteria. Statistical comparative studies were conducted in 42 patients with both anterior and posterior segment lesions using the paired-sample t-test. Pearson correlation was used to determine the relationship between pretreatment tumor size and posttreatment tumor response. Median administered activity, delivered radiation dose, and treatment volume were 2.3 GBq, 118.2 Gy, and 1,072 cm{sup 3}, respectively. Differences between the pretreatment tumor size of anterior and posterior liver segments were not statistically significant (p = 0.7981). Differences in tumor response between anterior and posterior liver segments were not statistically significant using WHO criteria (p = 0.8557). A statistically significant correlation did not exist between pretreatment tumor size and posttreatment tumor response (r = 0.0554, p = 0.4434). On imaging follow-up using WHO criteria, for anterior and posterior regions of the liver, (1) response rates were 50% (PR = 50%) and 45% (CR = 9%, PR = 36%), and (2) mean changes in tumor size were -41% and -40%. In conclusion, this study did not find evidence of preferential radiographic tumor response in posterior versus anterior liver segments treated with yttrium-90 glass microspheres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Arterial Configuration in Relation to the Segmental Anatomy of the Liver; Observations on MDCT and DSA Relevant to Radioembolization Treatment

PurposeCurrent anatomical classifications do not include all variants relevant for radioembolization (RE). The purpose of this study was to assess the individual hepatic arterial configuration and segmental vascularization pattern and to develop an individualized RE treatment strategy based on an extended classification.MethodsThe hepatic vascular anatomy was assessed on MDCT and DSA in patients who received a workup for RE between February 2009 and November 2012. Reconstructed MDCT studies were assessed to determine the hepatic arterial configuration (origin of every hepatic arterial branch, branching pattern and anatomical course) and the hepatic segmental vascularization territory of all branches. Aberrant hepatic arteries were defined as hepatic arterial branches that did not originate from the celiac axis/CHA/PHA. Early branching patterns were defined as hepatic arterial branches originating from the celiac axis/CHA.ResultsThe hepatic arterial configuration and segmental vascularization pattern could be assessed in 110 of 133 patients. In 59 patients (54 %), no aberrant hepatic arteries or early branching was observed. Fourteen patients without aberrant hepatic arteries (13 %) had an early branching pattern. In the 37 patients (34 %) with aberrant hepatic arteries, five also had an early branching pattern. Sixteen different hepatic arterial segmental vascularization patterns were identified and described, differing by the presence of aberrant hepatic arteries, their respective vascular territory, and origin of the artery vascularizing segment four.ConclusionsThe hepatic arterial configuration and segmental vascularization pattern show marked individual variability beyond well-known classifications of anatomical variants. We developed an individualized RE treatment strategy based on an extended anatomical classification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗