Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Characterization of CST Post-Processing AP-105 Hanford Tank Waste

The primary goal of the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions, LLC (WRPS), is to remove entrained solids and 137 Cs from the Hanford tank waste supernate to expedite production of low-activity waste. Ion exchange (IX) testing of 10.9 L of waste from Hanford tank 241-AP-105 (AP-105), performed by Pacific Northwest National Laboratory, used a lead-lag-polish column format, with a bed volume of 10 mL per column, to decontaminate tank waste supernate using crystalline silicotitanate (CST) as the IX media. The AP-105 Cs IX processing test, discussed elsewhere, resulted in a shorter transition zone (i.e., steeper load curve) than those defined by wastes from tanks 241-AP-107 and 241-AW-102.1 The shorter transition zone was indicative of a matrix effect retarding Cs capacity. Therefore, aliquots of spent CST from the lead, lag, and polish columns were subjected to a digestion protocol to quantify analytes retained by the CST and extrapolate the impact on Cs capacity. The spent CST was digested using a combination of 5 M HNO 3 and H 2 O 2 with vigorous heating and stirring. Due to the radiation dose accompanying the 137 Cs on the CST columns, a secondary Cs separation by ammonium molybdophosphate embedded in polyacrylonitrile (AMP-PAN) was performed to separate the 137 Cs from the CST so the samples could be contact-handled for analysis outside of a shielded facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geant4 Event Biasing and Fast Simulation

Geant4 offers advanced event biasing techniques to significantly accelerate simulations involving rare events. Various biasing methods, such as leading particle selection, cross-section biasing, radioactive decay enhancement, and bremsstrahlung splitting, enable efficient event sampling, though they require careful handling. Additionally, Geant4 provides a Fast Simulation Interface, allowing the replacement of standard processes in specific region and for selected particles, enabling faster execution or external code integration. Applications of fast simulation include electromagnetic shower modeling in calorimeters, machine learning inference, and offloading tasks to specialized hardware like GPUs, making Geant4 a powerful tool for computationally demanding simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A microfluidic platform for precision small-volume sample processing and its use to size separate biological particles with an acoustic microdevice [Precision size separation of biological particles in small-volume samples by an acoustic microfluidic system]

Here, a major advantage of microfluidic devices is the ability to manipulate small sample volumes, thus reducing reagent waste and preserving precious sample. However, to achieve robust sample manipulation it is necessary to address device integration with the macroscale environment. To realize repeatable, sensitive particle separation with microfluidic devices, this protocol presents a complete automated and integrated microfluidic platform that enables precise processing of 0.15–1.5 ml samples using microfluidic devices. Important aspects of this system include modular device layout and robust fixtures resulting in reliable and flexible world to chip connections, and fully-automated fluid handling which accomplishes closed-loop sample collection, system cleaning and priming steps to ensure repeatable operation. Different microfluidic devices can be used interchangeably with this architecture. Here we incorporate an acoustofluidic device, detail its characterization, performance optimization, and demonstrate its use for size-separation of biological samples. By using real-time feedback during separation experiments, sample collection is optimized to conserve and concentrate sample. Although requiring the integration of multiple pieces of equipment, advantages of this architecture include the ability to process unknown samples with no additional system optimization, ease of device replacement, and precise, robust sample processing.

42 ENGINEERING↗

Upfront Update on Barsebaeck 1-2 Reactor Internals Segmentation Project - 17382

Westinghouse is currently executing a contract, awarded in June 2015 from Barsebaeck Kraft AB, to segment all the reactor vessel (RV) internal parts in the two units 1 and 2. The scope of work covers the dismantling and segmentation of the RV internals under water, including the upfront engineering studies and equipment manufacturing and qualification. It also includes the loading of the segmented parts into waste cassettes, handling the cassettes, reactor internals sampling (73 samples), complementary water filtration system to catch the segmentation chips and contribute to maintaining water clarity during the segmentation work. Before leaving the site, the pool environment must be restored to the initial condition and all equipment will be decontaminated and shipped off site. The site work started in August 2016 with the mobilization on the Unit 2 and the actual cutting of the first component (steam dryer) started in September. Cutting will be performed with different types of Westinghouse designed cutting equipment. This paper presents the conceptual design of the reactor internals segmentation and packaging process that will be implemented at Barsebaeck, including the planning, methodology, equipment, waste management and packaging strategy. A first feedback on the site work will be provided for the segmentation of the Unit 2 reactor internals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRITIUM EFFECTS ON DYNAMIC MECHANICAL PROPERTIES OF POLYMERIC MATERIALS

Dynamic mechanical analysis has been used to characterize the effects of tritium gas (initially 1 atm. pressure, ambient temperature) exposure over times up to 2.3 years on several thermoplastics-ultrahigh molecular weight polyethylene (UHMW-PE), polytetrafluoroethylene (PTFE), and Vespel{reg_sign} polyimide, and on several formulations of elastomers based on ethylene propylene diene monomer (EPDM). Tritium exposure stiffened the elastic modulus of UHMW-PE up to about 1 year and then softened it, and reduced the viscous response monotonically with time. PTFE initially stiffened, however the samples became too weak to handle after nine months exposure. The dynamic properties of Vespel{reg_sign} were not affected. The glass transition temperature of the EPDM formulations increased approximately 4 C. following three months tritium exposure.

08 HYDROGEN↗

A Description of the XML "Dump Today's Collections" File Format of the BioWatch SMS Console (V.2.0.9)

The BioWatch Sample Management System is a software application to track the handling and history of holders, magazines, and Integrated Bio Aerosol Smart Sample cartridges for air sampling equipment. The user can generate a report in XML format for use by other software applications. This report documents the format of that XML report for Portable Sampling Units. In this version of the XML file, there are no longer any Storage or Archived elements. Also, the Received element for the PSU collector is now named Receive.

99 GENERAL AND MISCELLANEOUS↗

Development of a Trace Detection Method for Mercury Speciation in Hanford Tank Waste - 19014

The U.S. Department of Energy's (DOE) Hanford Site in southeast Washington State stores 56 million gallons of chemical and radioactive waste stored in underground tanks. Mercury species in liquid and solid fractions of Hanford tank waste pose a risk to the implementation and execution of DoE's River Protection Project mission due to mercury concentration limits imposed under waste acceptance criteria, toxicity characteristic leaching procedure restrictions for secondary waste disposal, and air emission permits. Although there is currently no processing of tank waste at Hanford, waste processing is imminent, and representative mercury inventory tracking will be important to anticipate and mitigate stack emissions and secondary liquid waste disposal issues. A methodology to accurately determine total mercury and mercury speciation in Hanford tank waste, while maintaining low mercury detection limits, currently does not exist at Hanford. Moreover, the mercury species in the waste solids are unknown and may be waste type-specific. The development of an analytical method to separate and speciate mercury in tank waste was undertaken by the Pacific Northwest National Laboratory (PNNL) while leveraging an existing non-radiological, ultra-trace mercury detection technique frequently performed at PNNL's Marine Sciences Laboratory in Sequim, Washington. The ultimate goal of this work is to develop an analytical method to obtain detailed mercury speciation information and update flowsheet modeling assumptions related to mercury partitioning at Hanford. The first phase of testing was completed in the development of an analytical methodology for the low-level determination of total mercury, elemental mercury, methylmercury, and dimethylmercury in Hanford tank waste. This paper presents Phase I testing which focused on determining whether mercury species can be preconcentrated from aqueous Hanford tank waste solution onto a solid substrate, while simultaneously eliminating or very significantly reducing the parent radionuclide activity. This was demonstrated by developing protocols for the separation and preconcentration of total mercury and methylmercury onto solid substrates, then measuring the substrates for radiological content at PNNL's Radiochemical Processing Laboratory on the Hanford Site. The mercury content was successfully separated onto stable substrates and the radionuclide activity reduction was significant enough that the preconcentrated samples could be subjected to quantification using far less restrictive handling and radiological controls than would be required for the parent sample (i.e., contamination area fume hood vs. hot cell). This mercury separation method required no sample dilution, which enables maximum mercury detectability, while still allowing mercury speciation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Collaborative, Nondestructive Analysis of Contaminated Soil

This report summarizes a joint nondestructive analysis exercise that LLNL, LANL, and COMENA discussed through a collaborative meeting in July 2017. This work was performed as one part of a collaboration with Algeria under Action Sheet 7: “Technical Cooperation and Assistance in Nuclear Forensics”. The primary intent of this exercise was for US and Algerian participants to jointly share results of nondestructive analyses (NDA) of a contaminated soil sample provided by the Algerians and to discuss key observations and analytical approaches. While the two samples were analyzed blind at LLNL and LANL, the soil samples were revealed after the exercise to have a common origin, and to have originated as an IAEA soil sample (IAEA-326, Bojanowski et al., 2001) provided to COMENA as part of a previous exercise. Comparative analysis revealed common findings between the laboratories, and also emphasized the need for standardized operating procedures to improve inter-comparability and confidence in conclusions. Recommended handling practices in the presence of sample heterogeneities were also discussed. This exercise provided an opportunity to demonstrate nuclear forensics analytical capabilities at COMENA, LANL, and LLNL, and identified areas that could benefit from future technical exchanges. Plans were made for a follow-on joint exercise in 2018, involving destructive analyses of the CUP-2 uranium ore concentrate standard.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-Throughput Characterization and Optimization of Polyamide Hydrolase Activity Using Open Port Sampling Interface Mass Spectrometry

Enzymatic biodegradation of polymers, such as polyamides (PA), has the potential to cost-effectively reduce plastic waste, but enhancements in degradation efficiency are needed. Engineering enzymes through directed evolution is one pathway toward identification of critical domains needed for improving activity. However, screening such enzymatic libraries (100s-to-1000s of samples) is time-consuming. Here we demonstrate the use of robotic autosampler (PAL) and immediate drop on demand technology (I.DOT) liquid handling systems coupled with open-port sampling interface-mass spectrometry (OPSI-MS) to screen for PA6 and PA66 hydrolysis by 6-aminohexanoate-oligomer endo-hydrolase (nylon hydrolase, NylC) in a high-throughput (8–20 s/sample) manner. The OPSI-MS technique required minimal sample preparation and was amenable to 96-well plate formats for automated processing. Enzymatic hydrolysis of PA characteristically produced soluble linear oligomer products that could be identified by OPSI-MS. Incubation temperatures and times were optimized for PA6 (65 °C, 24 h) and PA66 (75 °C, 24 h) over 108 experiments. In addition, the I.DOT/OPSI-MS quantified production of PA6 linear dimer (8.3 ± 1.6 μg/mL) and PA66 linear monomer (13.5 ± 1.5 μg/mL) by NylC with a lower limit of detection of 0.029 and 0.032 μg/mL, respectively. For PA6 and PA66, linear oligomer production corresponded to 0.096 ± 0.018% and 0.204 ± 0.028% conversion of dry pellet mass, respectively. The developed methodology is expected to be utilized to assess enzymatic hydrolysis of engineered enzyme libraries, comprising hundreds to thousands of individual samples.

47 OTHER INSTRUMENTATION↗

Influence of probe sampling on reacting species measurement in diluted combustion

In-flame measurements of temperature and major species are realized with intrusive probes in a laboratory scale furnace working in diluted combustion. The shape and the position of the reaction zone are experimentally identified from the distribution of temperature and carbon monoxide in a particular symmetry plane. For this purpose, two probes were designed: the sampling probe, to measure species content of the gas sample and the suction pyrometer, for the temperature. The first is completely cooled to quench the reaction, but the second is just partly cooled for handling. However, as both probes take gas sample, the species content is available in either case. Consequently the suction pyrometer can be used to measure simultaneously temperature and species, reducing by half the length of the experimental campaign. Comparing species contents on a non-reactive mixture, it has been observed that the spatial averaging is the same with both probes. The perturbation of the flow is assessed thanks to a CFD modeling of the furnace including the probe. Even if it is significant - the differences between the computed values and the measurements are about 3-4 times the measurement error - the position and the value of the maximum is well captured as well as the opening of the jet. However, the species contents measured within a reactive mixture differ significantly. For a stable regime, the levels and the distribution of CO are similar with both probes, but the gradients at the border of the reaction zone are sharper with the suction pyrometer. For another regime, for which the reaction zone is lifted and less stable, the fields of species are completely different following the probe used. A chemical kinetic modeling has shown that the reaction inside the non-cooled part of the suction pyrometer is promoted when it is placed in particular region. The use of the suction pyrometer as sampling probe inside a reaction zone should therefore be avoided even in diluted combustion. The error made on the fields of species cannot be quantified to be taken into account a posteriori, because in certain conditions the results are completely unrealistic. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Adapting a Low-Cost and Open-Source Commercial Pipetting Robot for Nanoliter Liquid Handling

Nanoliter liquid handling capabilities in bioanalytical workflows can reduce reagent costs and improve sample processing efficiency. Here we report the successful modification of a low-cost commercially available pipetting robot, the Opentrons 1 (OT1), using inexpensive 3D-printed parts to accommodate low-nanoliter volumes. The pipetting accuracy and precision of the modified OT1 for 50 nL volumes of water was 0.2% and 2%, respectively. The accuracy and precision at 20 nL was 1% and 3.8%, respectively. The platform was successfully applied to the preparation of low-nanogram proteomic samples for liquid chromatography-mass spectrometry analysis. The modified OT1 is thus an effective platform for nanoliter liquid handling and, at a total cost of less than $6000 including the commercial liquid handler and all modifications, is far less expensive and more versatile than other platforms with similar capabilities, placing this technology within reach of a far broader scientific community.

47 OTHER INSTRUMENTATION↗

QUASI-ISENTROPIC COMPRESSION OF MATERIALS USING THE MAGNETIC LOADING TECHNIQUE

The magnetic loading technique using pulsed power generators was first developed about a decade ago on the Z Accelerator, and has matured significantly. The recent development of small, pulsed power generators have enabled several key issues in isentropic compression experiments (ICE), such as panel design, sample preparation, and uniformity of loading to be studied. Veloce is a medium-voltage, high-current, compact pulsed power generator developed for cost effective isentropic experiments. The machine delivers approx2.5 MA of current rapidly (approx440-530 ns) into an inductive load where significant magnetic pressures are produced. Examples of recent material strength measurements from quasi-isentropic loading and unloading of materials are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Conceptual design of a versatile radiation tolerant integrated signal conditioning circuit for resistive sensors

This paper presents the design of a radiation tolerant configurable discrete time CMOS signal conditioning circuit for use with resistive sensors like strain gauge pressure sensors. The circuit is intended to be used for remote handling in harsh environments in the International Thermonuclear Experimental fusion Reactor (ITER). The design features a 5 V differential preamplifier using a Correlated Double Sampling (CDS) architecture at a sample rate of 20 kHz and a 24 V discrete time post amplifier. The gain is digitally controllable between 27 and 400 in the preamplifier and between 1 and 8 in the post amplifier. The nominal input referred noise voltage is only 8.5 {mu}V while consuming only 1 mW. The circuit has a simulated radiation tolerance of more than 1 MGy. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detecting differential protein expression in large-scale population proteomics

Mass spectrometry-based high-throughput quantitative proteomics shows great potential in clinical biomarker studies, identifying and quantifying thousands of proteins in biological samples. However, methods are needed to appropriately handle issues/challenges unique to mass spectrometry data in order to detect as many biomarker proteins as possible. One issue is that different mass spectrometry experiments generate quite different total numbers of quantified peptides, which can result in more missing peptide abundances in an experiment with a smaller total number of quantified peptides. Another issue is that the quantification of peptides is sometimes absent, especially for less abundant peptides and such missing values contain the information about the peptide abundance. Here, we propose a Significance Analysis for Large-scale Proteomics Studies (SALPS) that handles missing peptide intensity values caused by the two mechanisms mentioned above. Our model has a robust performance in both simulated data and proteomics data from a large clinical study. Because varying patients’ sample qualities and deviating instrument performances are not avoidable for clinical studies performed over the course of several years, we believe that our approach will be useful to analyze large-scale clinical proteomics data.

Environmental Molecular Sciences Laboratory↗

Transboundary determinants of avian zoonotic infectious diseases: challenges for strengthening research capacity and connecting surveillance networks

As the climate changes, global systems have become increasingly unstable and unpredictable. This is particularly true for many disease systems, including subtypes of highly pathogenic avian influenzas (HPAIs) that are circulating the world. Ecological patterns once thought stable are changing, bringing new populations and organisms into contact with one another. Wild birds continue to be hosts and reservoirs for numerous zoonotic pathogens, and strains of HPAI and other pathogens have been introduced into new regions via migrating birds and transboundary trade of wild birds. With these expanding environmental changes, it is even more crucial that regions or counties that previously did not have surveillance programs develop the appropriate skills to sample wild birds and add to the understanding of pathogens in migratory and breeding birds through research. For example, little is known about wild bird infectious diseases and migration along the Mediterranean and Black Sea Flyway (MBSF), which connects Europe, Asia, and Africa. Focusing on avian influenza and the microbiome in migratory wild birds along the MBSF, this project seeks to understand the determinants of transboundary disease propagation and coinfection in regions that are connected by this flyway. Through the creation of a threat reduction network for avian diseases (Avian Zoonotic Disease Network, AZDN) in three countries along the MBSF (Georgia, Ukraine, and Jordan), this project is strengthening capacities for disease diagnostics; microbiomes; ecoimmunology; field biosafety; proper wildlife capture and handling; experimental design; statistical analysis; and vector sampling and biology. Here, we cover what is required to build a wild bird infectious disease research and surveillance program, which includes learning skills in proper bird capture and handling; biosafety and biosecurity; permits; next generation sequencing; leading-edge bioinformatics and statistical analyses; and vector and environmental sampling. Creating connected networks for avian influenzas and other pathogen surveillance will increase coordination and strengthen biosurveillance globally in wild birds.

54 ENVIRONMENTAL SCIENCES↗