Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURGERY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Flammability and sensitivity of materials in oxygen-enriched atmospheres; Proceedings of the Fourth International Symposium, Las Cruces, NM, Apr. 11-13, 1989. Volume 4

The present volume discusses the ignition of nonmetallic materials by the impact of high-pressure oxygen, the promoted combustion of nine structural metals in high-pressure gaseous oxygen, the oxygen sensitivity/compatibility ranking of several materials by different test methods, the ignition behavior of silicon greases in oxygen atmospheres, fire spread rates along cylindrical metal rods in high-pressure oxygen, and the design of an ignition-resistant, high pressure/temperature oxygen valve. Also discussed are the promoted ignition of oxygen regulators, the ignition of PTFE-lined flexible hoses by rapid pressurization with oxygen, evolving nonswelling elastomers for high-pressure oxygen environments, the evaluation of systems for oxygen service through the use of the quantitative fault-tree analysis, and oxygen-enriched fires during surgery of the head and neck.

Stoltzfus, Joel M.↗

Movable Cameras And Monitors For Viewing Telemanipulator

Three methods proposed to assist operator viewing telemanipulator on video monitor in control station when video image generated by movable video camera in remote workspace of telemanipulator. Monitors rotated or shifted and/or images in them transformed to adjust coordinate systems of scenes visible to operator according to motions of cameras and/or operator's preferences. Reduces operator's workload and probability of error by obviating need for mental transformations of coordinates during operation. Methods applied in outer space, undersea, in nuclear industry, in surgery, in entertainment, and in manufacturing.

Diner, Daniel B.↗

Electromechanical Nerve Stimulator

Nerve stimulator applies and/or measures precisely controlled force and/or displacement to nerve so response of nerve measured. Consists of three major components connected in tandem: miniature probe with spherical tip; transducer; and actuator. Probe applies force to nerve, transducer measures force and sends feedback signal to control circuitry, and actuator positions force transducer and probe. Separate box houses control circuits and panel. Operator uses panel to select operating mode and parameters. Stimulator used in research to characterize behavior of nerve under various conditions of temperature, anesthesia, ventilation, and prior damage to nerve. Also used clinically to assess damage to nerve from disease or accident and to monitor response of nerve during surgery.

Tcheng, Ping↗

Surgical Force-Measuring Probe

Aerodynamic balance adapted to medical use. Electromechanical probe measures forces and moments applied to human tissue during surgery. Measurements used to document optimum forces and moments for surgical research and training. In neurosurgical research, measurements correlated with monitored responses of nerves. In training, students learn procedures by emulating forces used by experienced surgeons. Lightweight, pen-shaped probe easily held by surgeon. Cable feeds output signals to processing circuitry.

Tcheng, Ping↗

Automatic Detection of Seizures with Applications

There are an estimated two million people with epilepsy in the United States. Many of these people do not respond to anti-epileptic drug therapy. Two devices can be developed to assist in the treatment of epilepsy. The first is a microcomputer-based system designed to process massive amounts of electroencephalogram (EEG) data collected during long-term monitoring of patients for the purpose of diagnosing seizures, assessing the effectiveness of medical therapy, or selecting patients for epilepsy surgery. Such a device would select and display important EEG events. Currently many such events are missed. A second device could be implanted and would detect seizures and initiate therapy. Both of these devices require a reliable seizure detection algorithm. A new algorithm is described. It is believed to represent an improvement over existing seizure detection algorithms because better signal features were selected and better standardization methods were used.

Olsen, Dale E.↗

A Fiber Optic Probe for the Detection of Cataracts

A compact fiber optic probe developed for on-orbit science experiments was used to detect the onset of cataracts, a capability that could eliminate physicians' guesswork and result in new drugs to 'dissolve' or slow down the cataract formation before surgery is necessary. The probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for excised but intact human eye lenses. In a clinical setting, the device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics. In this set-up, the integrated fiber optic probe, the size of a pencil, delivers a low power cone of laser light into the eye of a patient and guides the light which is backscattered by the protein molecules of the lens through a receiving optical fiber to a photo detector. The non-invasive DLS measurements provide rapid determination of protein crystalline size and its size distribution in the eye lens.

Ansari, Rafat R.↗

Balloon Catheter Prevents Contamination

Balloon catheter similar to that used in such medical procedures as angioplasty and heart surgery protects small orifices against contamination and blockage by chips generated in machining operations. Includes small, inflatable balloon at end of thin, flexible tube. Contains additional features adapting it to anticontamination service: balloon larger to fit wider channel it must block; made of polyurethane (rather than latex), which does not fragment if bursts; material made thicker to resist abrasion better; and kink-resistant axial wire helps catheter negotiate tight bends.

Higginson, Gregory A.↗

Ventilating Air-Conditioner

Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

Dinh, Khanh↗

US-USSR telemedicine consultation spacebridge to Armenia and Ufa

The Final Report on the U.S.-U.S.S.R. Telemedicine Consultation Spacebride to Armenia and Ufa is presented. The goal of this activity was to provide expert medical consultation to the Armenian medical personnel in the areas of plastic and reconstructive surgery, physical and psychological rehabilitation, public health, and epidemiology following the devastating earthquake in Dec. 1988. The U.S. and U.S.S.R. implementation teams developed new standards for medical information transmittal as well as protocols and schedules on how to conduct medical consultations. The consultations were provided to the Republic Diagnostic Center in Yerevan, U.S.S.R. by four U.S. medical centers: University of Utah/LDS Hospital, University of Texas, Maryland Institute for Emergency Medical Service Systems, and Uniformed Services University of the Health Sciences.

Source record↗

Reassessment of area postrema's role in motion sickness and conditioned taste aversion

On the basis of classical studies on the role of the area psotrema (AP) in motion-induced emesis it was generally accepted that the AP is an essential structure for the production of vomiting in response to motion. However, in more recent studies it has been demonstrated that vomiting induced by motion can still occur in animals in which the AP has been destroyed bilaterally. It was inferred from some of these more recent studies that the AP plays no role in motion-induced emesis. From the standpoint of the current understanding of central nervous system (CNS) plasticity, redundancy, remodeling, unmasking, regeneration, and recovery of function, however, it is important to realize the limitations of using ablation procedures to determine the functional role of a given neural structure in a highly integrated, adaptable central nervous system (CNS). For example, the results of our recent investigations in cat and squirrel monkey on the role of the AP in emesis and conditioned taste aversion induced by motion indicate that while AP lesions do not prevent motion-induced emesis when animals are tested 30 days or more after surgery, the lesions do change the latency to emesis. Thus, contradictory findings from lesion studies must be evaluated not only in terms of species difference, differences in lesioning techniques and extent of lesions, and in stimulus parameters, but also in terms of duration of the recovery period, during which significant recovery of function may take place. In our judgment, inadequate consideration of the foregoing factors could lead to erroneous inferences about given structure's role in the behavior of the intact, nonablated animal.

N G Daunton↗

Conditioned taste aversion and motion sickness in cats and squirrel monkeys

The relationship between vomiting and conditioned taste aversion was studied in intact cats and squirrel monkeys and in cats and squirrel monkeys in which the area postrema was ablated by thermal cautery. In cats conditioned 7-12 months after ablation of the area postrema, three successive treatments with xylazine failed to produce either vomiting or conditioned taste aversion to a novel fluid. Intact cats, however, vomited and formed a conditioned aversion. In squirrel monkeys conditioned 6 months after ablation of the area postrema, three treatments with lithium chloride failed to produce conditioned taste aversion. Intact monkeys did condition with these treatments. Neither intact nor ablated monkeys vomited or evidenced other signs of illness when injected with lithium chloride. When the same ablated cats and monkeys were exposed to a form of motion that produced vomiting prior to surgery, conditioned taste aversion can be produced after ablation of the area postrema. The utility of conditioned taste aversion as a measure of subemetic motion sickness is discussed by examining agreement and disagreement between identifications of motion sickness by conditioned taste aversion and vomiting. It is suggested that a convincing demonstration of the utility of conditioned taste aversion as a measure of nausea requires the identification of physiological correlates of nausea, and caution should be exercised when attempting to interpret conditioned taste aversion as a measure of nausea.

area postrema↗

Quantitative 3-D imaging topogrammetry for telemedicine applications

The technology to reliably transmit high-resolution visual imagery over short to medium distances in real time has led to the serious considerations of the use of telemedicine, telepresence, and telerobotics in the delivery of health care. These concepts may involve, and evolve toward: consultation from remote expert teaching centers; diagnosis; triage; real-time remote advice to the surgeon; and real-time remote surgical instrument manipulation (telerobotics with virtual reality). Further extrapolation leads to teledesign and telereplication of spare surgical parts through quantitative teleimaging of 3-D surfaces tied to CAD/CAM devices and an artificially intelligent archival data base of 'normal' shapes. The ability to generate 'topogrames' or 3-D surface numerical tables of coordinate values capable of creating computer-generated virtual holographic-like displays, machine part replication, and statistical diagnostic shape assessment is critical to the progression of telemedicine. Any virtual reality simulation will remain in 'video-game' realm until realistic dimensional and spatial relational inputs from real measurements in vivo during surgeries are added to an ever-growing statistical data archive. The challenges of managing and interpreting this 3-D data base, which would include radiographic and surface quantitative data, are considerable. As technology drives toward dynamic and continuous 3-D surface measurements, presenting millions of X, Y, Z data points per second of flexing, stretching, moving human organs, the knowledge base and interpretive capabilities of 'brilliant robots' to work as a surgeon's tireless assistants becomes imaginable. The brilliant robot would 'see' what the surgeon sees--and more, for the robot could quantify its 3-D sensing and would 'see' in a wider spectral range than humans, and could zoom its 'eyes' from the macro world to long-distance microscopy. Unerring robot hands could rapidly perform machine-aided suturing with precision micro-sewing machines, splice neural connections with laser welds, micro-bore through constricted vessels, and computer combine ultrasound, microradiography, and 3-D mini-borescopes to quickly assess and trace vascular problems in situ. The spatial relationships between organs, robotic arms, and end-effector diagnostic, manipulative, and surgical instruments would be constantly monitored by the robot 'brain' using inputs from its multiple 3-D quantitative 'eyes' remote sensing, as well as by contact and proximity force measuring devices. Methods to create accurate and quantitative 3-D topograms at continuous video data rates are described.

Altschuler, Bruce R.↗

Aircraft to Medicine

This video discusses how the technology of computer modeling can improve the design and durability of artificial joints for human joint replacement surgery. Also, ultrasound, originally used to detect structural flaws in aircraft, can also be used to quickly assess the severity of a burn patient's injuries, thus aiding the healing process.

Source record↗

Biotelemetry implant volume and weight in rats: A pilot study report

This paper reports the results of a pilot study in which a 240-gram rat was implanted for 41 days with biotelemetry devices weighing a total of 36 gm (18 cc). The implanted animal showed no differences in weight gain, food and water consumption, and postnecropsy organ weights when compared to both an unoperated control animal and an animal that underwent surgery but did not receive an implant. The implanted animal also had temperature and activity rhythms similar to those reported using much smaller implants. Thus, this pilot study showed that a 240-gm rat could be implanted with biotelemetry devices weighing nearly 15 percent of body weight without significant changes in health or behavior. A larger study involving more animals and similar implant sizes is recommended.

Somps, Chris J.↗

A surgical support system for Space Station Freedom

Surgical techniques in microgravity are being developed for the Health Maintenance Facility (HMF) on Space Station Freedom (SSF). This will be a presentation of the proposed surgical capabilities and ongoing hardware and procedural investigations. Methods: Procedures and prototype hardware, which include a medical restraint system, a surgical overhead isolation canopy, a suction device, and a regional laminar flow device were evaluated. This was accomplished by realistic sterile surgical simulations involving both mannequins and animals during KC-135 parabolic flight and in a high fidelity ground based HMF mockup. Results: Animal surgery in the environment of microgravity allowed the observation of unique arterial and venous bleeding characteristics for the first time. The ability to control bleeding and to prevent cabin atmosphere contamination was also demonstrated. Conclusions: The procedures and prototype hardware tested provided valuable information and should be investigated and developed further. The use of standard surgical techniques are possible in microgravity if the principles of personnel and supply restraint and operative field containment are adhered to.

Campbell, M. R.↗

Grounding explanations in evolving, diagnostic situations

Certain fields of practice involve the management and control of complex dynamic systems. These include flight deck operations in commercial aviation, control of space systems, anesthetic management during surgery or chemical or nuclear process control. Fault diagnosis of these dynamic systems generally must occur with the monitored process on-line and in conjunction with maintaining system integrity.This research seeks to understand in more detail what it means for an intelligent system to function cooperatively, or as a 'team player' in complex, dynamic environments. The approach taken was to study human practitioners engaged in the management of a complex, dynamic process: anesthesiologists during neurosurgical operations. The investigation focused on understanding how team members cooperate in management and fault diagnosis and comparing this interaction to the situation with an Artificial Intelligence(AI) system that provides diagnoses and explanations. Of particular concern was to study the ways in which practitioners support one another in keeping aware of relevant information concerning the state of the monitored process and of the problem solving process.

Johannesen, Leila J.↗

Transport out of the lower stratospheric Arctic vortex by Rossby wave breaking

The fine-scale structure in lower stratospheric tracer transport during the period of the two Arctic Airborne Stratospheric Expeditions (January and February 1989; December 1991 to March 1992) is investigated using contour advection with surgery calculations. These calculations show that Rossby wave breaking is an ongoing occurrence during these periods and that air is ejected from the polar vortex in the form of long filamentary structures. There is good qualitative agreement between these filaments and measurements of chemical tracers taken aboard the NASA ER-2 aircraft. The ejected air generally remains filamentary and is stretched and mixed with midlatitude air as it is wrapped around the vortex. This process transfers vortex air into midlatitudes and also produces a narrow region of fine-scale filaments surrounding the polar vortex. Among other things, this makes it difficult to define a vortex edge. The calculations also show that strong stirring can occur inside as well as outside the vortex.

Waugh, D. W.↗

Intrusions into the lower stratospheric Arctic vortex during the winter of 1991-1992

Investigations of the kinematics of the lower stratospheric Arctic vortex during the winter of 1991-1992 using the contour advection with surgery technique reveal three distinct events in which there was substantial intrusion of midlatitude air into the vortex, in apparent contradiction of the view that the polar vortex constitutes an isolated air mass. Two of these events, in late January and mid-February, were well documented. They were predicted in high-resolution forecasts by the European Centre for Medium-Range Weather Forecasts, most clearly in experimental forecasts with reduced diffusion. Direct confirmation of the presence of the intrusions and of their calculated locations was provided by aerosol observations from the airborne differential absorption laser lidar aboard the NASA DC-8, taken as part of the second Airborne Arctic Stratospheric Expedition campaign; aerosol-rich air of midlatitude origin was seen in the expected position of the intrusions. The reality of the February event was also confirmed by in situ measurements from the NASA ER-2. Such events may be significant for the chemical processes taking place within the winter vortex. The intrusions were evidently related to the meteorology of the northern stratosphere during this winter and in particular to persistent tropospheric blocking over the northeastern Atlantic Ocean and western Europe and concomitant ridging into the lower stratospheric vortex in this region. Nevertheless, preliminary investigations have indicated that such events are not uncommon in other northern hemisphere winters, although no such events were found in the southern hemisphere during the Antarctic winter of 1987.

Plumb, R. A.↗