Equidistant optimization of elliptical superconducting rf standing wave cavities

A record accelerating rate was achieved earlier in standing wave (SW) SRF cavities when their shape was optimized for a lower peak surface magnetic field sacrificing the peak surface electric field. In view of new materials with higher limiting magnetic fields, expected for SRF cavities, in the first line of the Nb 3 Sn, the approach to optimization of cavity shape should be revised. A method of equidistant optimization, offered earlier for traveling wave (TW) cavities is applied to SW cavities. It is shown here that without limitation by magnetic field, the maximal accelerating rate is defined not only by limitations of the electric field but to a significant degree by the cavity shape. For example, for a cavity with the aperture radius of $R$ $a$ = 35 mm, the minimal ratio of the peak surface electric field to the accelerating rate is about $E$ pk / $E$ acc = 1.54. So, with the maximal surface field experimentally achieved $E$ pk ~ 125 MV / m, the maximal achievable accelerating rate is about 80 MeV / m even if there are no restrictions by the magnetic field. Optimized cavity shapes with and without limitations by a magnetic field are presented. Another opportunity—optimization for a low magnetic field, is opening for the same material, Nb 3 Sn, with the purpose of having a high-quality factor and increased accelerating rate that can be used for industrial linacs with cryocooler-based cooling scheme.

43 PARTICLE ACCELERATORS↗

Characterizing a supernova’s standing accretion shock instability with neutrinos and gravitational waves

Here, we perform a novel multi-messenger analysis for the identification and parameter estimation of the Standing Accretion Shock Instability (SASI) in a core collapse supernova with neutrino and gravitational wave (GW) signals. In the neutrino channel, this method performs a likelihood ratio test for the presence of SASI in the frequency domain. For gravitational wave signals we process an event with a modified constrained likelihood method. Using simulated supernova signals, the properties of the Hyper-Kamiokande neutrino detector, and O3 LIGO Interferometric data, we produce the two-dimensional probability density distribution (PDF) of the SASI activity indicator and calculate the probability of detection P D as well as the false identification probability P FI . We discuss the probability to establish the presence of the SASI as a function of the source distance in each observational channel, as well as jointly. Compared to a single-messenger approach, the joint analysis results in P D (at P FI = 0.1) of SASI activities that is larger by up to ≈ 40% for a distance to the supernova of 5 kpc. We also discuss how accurately the frequency and duration of the SASI activity can be estimated in each channel separately. Our methodology is suitable for implementation in a realistic data analysis and a multi-messenger setting.

79 ASTRONOMY AND ASTROPHYSICS↗

Multilevel analysis between Physcomitrium patens and Mortierellaceae endophytes explores potential long‐standing interaction among land plants and fungi

SUMMARY The model moss species Physcomitrium patens has long been used for studying divergence of land plants spanning from bryophytes to angiosperms. In addition to its phylogenetic relationships, the limited number of differential tissues, and comparable morphology to the earliest embryophytes provide a system to represent basic plant architecture. Based on plant–fungal interactions today, it is hypothesized these kingdoms have a long‐standing relationship, predating plant terrestrialization. Mortierellaceae have origins diverging from other land fungi paralleling bryophyte divergence, are related to arbuscular mycorrhizal fungi but are free‐living, observed to interact with plants, and can be found in moss microbiomes globally. Due to their parallel origins, we assess here how two Mortierellaceae species, Linnemannia elongata and Benniella erionia , interact with P. patens in coculture. We also assess how Mollicute ‐related or Burkholderia ‐related endobacterial symbionts (MRE or BRE) of these fungi impact plant response. Coculture interactions are investigated through high‐throughput phenomics, microscopy, RNA‐sequencing, differential expression profiling, gene ontology enrichment, and comparisons among 99 other P. patens transcriptomic studies. Here we present new high‐throughput approaches for measuring P. patens growth, identify novel expression of over 800 genes that are not expressed on traditional agar media, identify subtle interactions between P. patens and Mortierellaceae, and observe changes to plant–fungal interactions dependent on whether MRE or BRE are present. Our study provides insights into how plants and fungal partners may have interacted based on their communications observed today as well as identifying L. elongata and B. erionia as modern fungal endophytes with P. patens .

59 BASIC BIOLOGICAL SCIENCES↗

Chemical and structural characterization of EUV photoresists as a function of depth by standing-wave x-ray photoelectron spectroscopy

The success in the miniaturization of the electronic device constituents depends mostly on the photolithographic techniques. Recently, to achieve patterning at the sub-10-nm node, extreme ultraviolet (EUV) lithography has been introduced into high volume production. Continued scaling of EUV via increased numerical aperture to achieve nodes at 3-nm and below requires the development of fundamentally new patterning materials and new characterization methods. Current EUV-resist film thicknesses are in the 20- to 40-nm range, and further thickness reduction is required for the next generation. Therefore, interfaces become exceedingly important, and the properties of the resist film would be dominated by top and bottom interfacial effects. X-ray photoelectron spectroscopy (XPS) combined with standing-wave excitation (SW-XPS), a fairly new method in the EUV lithography field, previously had been largely applied in multilayers and superlattices for characterizing the composition and electronic structure of buried layers and interfaces as a function of depth. We applied the SW-XPS method to organic/inorganic photoresists to provide depth-selective information on their structural and chemical conditions of as a function of temperature, EUV exposure, different underlayers, and other fundamental parameters. As a first attempt, we perform an SW-XPS feasibility study on self-assembled monolayer (SAM) films after exposure to an electron beam. By SW-XPS, we determined that the interface between the Al 2 O 3 underlayer and the SAMs is smooth, with a mean roughness of about 0.2 nm. Moreover, we determined that the SAM chains are, on average, tilted by 1/430 deg off the sample normal. The SW-XPS results also suggest that the SAM is not a perfectly aligned and uniform monolayer, with some areas having thickness higher than a single monolayer. We demonstrated that SW-XPS can provide useful information on ultrathin materials with high potential for being used as a characterization method of organic/inorganic photoresists.

36 MATERIALS SCIENCE↗

Physics-informed neural networks for identification of material properties using standing waves

A metallic structure in its initial stage of failure involves plastic deformation or environmental degradation that changes the elastic modulus and density. This work presents the detection of change in wave velocity (a function of elastic modulus and density) as a system identification problem. A physics-informed neural network (PINN) is proposed to solve the system identification problem. The PINN takes the spatial coordinates of scanning locations and time as inputs and provides the displacement and wave velocity as outputs. The governing partial differential equation of standing waves in a rod is incorporated into the neural network as physics in the form of a loss function. The wave velocity vector is randomly initiated. During the training of the network, physics is used to determine and update the wave velocity target vector from the network’s displacement predictions. The measured data, comprising sparse displacement response on the rod structure, are used to train the PINN. The wave velocity at the sparse locations on the rod is learned from the predicted displacements during the training. Using the predictions of the trained network, the response of free vibration or material property variation can be reconstructed at unscanned locations on the structure to obtain high-resolution maps for full-field imaging to detect and localize the changes caused by plastic deformation. The PINN’s sparse scanning and simultaneous prediction capability during training can lead to high scanning and data-processing speeds. This capability yields a nondestructive evaluation system that can predict the presence of degraded material locations as the structural vibrations are scanned and processed in real time.

Rathod, Vivek↗

Fugitive methane detection using open-path stand-off chirped laser dispersion spectroscopy

We report an open-path chirped laser dispersion spectrometer capable of detecting the atmospheric methane concentration above the background using both specular and diffusive reflective surfaces via two distinct operation modes in a stand-off detection configuration. The system is integrated with simultaneous ranging functionality, which enables average concentration measurements for varying optical pathlengths. The system was first tested for accuracy and characterized to achieve sensitivity of 2.9 p p m - m / H z 1 / 2 and pathlength precision of 0.2 m / H z 1 / 2 with a controlled release of methane outside the laboratory. The instrument was subsequently field-deployed in the proximity of a natural gas compressor station for fugitive methane detection. The instrument successfully detected methane plumes and narrowed down the location of the plume through multi-path measurement. The field measurements were verified by a co-located reference mobile methane sensor.

Chen, Yifeng↗

Enhanced biochemical sensing with high- Q transmission resonances in free-standing membrane metasurfaces

Optical metasurfaces provide solutions to label-free biochemical sensing by localizing light resonantly beyond the diffraction limit, thereby selectively enhancing light–matter interactions for improved analytical performance. However, high-Q resonances in metasurfaces are usually achieved in the reflection mode, which impedes metasurface integration into compact imaging systems. Here, we demonstrate a metasurface platform for advanced biochemical sensing based on the physics of the bound states in the continuum (BIC) and electromagnetically induced transparency (EIT) modes, which arise when two interfering resonances from a periodic pattern of tilted elliptic holes overlap both spectrally and spatially, creating a narrow transparency window in the mid-infrared spectrum. We experimentally measure these resonant peaks observed in transmission mode (Q ~ 734 at λ ~ 8.8 µm) in free-standing silicon membranes and confirm their tunability through geometric scaling. We also demonstrate the strong coupling of the BIC-EIT modes with a thinly coated PMMA film on the metasurface, characterized by a large Rabi splitting (32 cm -1 ) and biosensing of protein monolayers in transmission mode. Our new photonic platform can facilitate the integration of metasurface biochemical sensors into compact and monolithic optical systems while being compatible with scalable manufacturing, thereby clearing the way for on-site biochemical sensing in everyday applications.

Rosas, Samir [Univ. of Wisconsin, Madison, WI (Uni↗

Daily water stable isotopes, transpiration, and matrix potential data for an aspen and engelmann stand in the East River Watershed (version 2)

We provide daily stable isotope (2H & 18O) ratios in soil water and xylem (plant stem) water, as well as the sap flow (transpiration) and the soil's matric potential at a forested site near Gothic, Colorado, in the East River catchment. We measured the stable isotopic composition of the transpiration and the daily transpiration flux sum of three aspen and three engelmann spruce. In both forest stands, we installed a soil profile and measured the soil matric potential at 15, 30, and 60 cm depth as well as the stable isotopes of soil pore water at 5, 10, 30, 60, and 90 cm depths. All isotope measurements were done in situ via vapor probes connected to a cavity ring down spectrometer (Picarro L1240i).We further report the daily meteorological data observed at billy barr near our study site. We also provide for each tree the relative share of root water uptake derived from the isotope measurements via a Bayesian mixing model (MixSIAR).The daily data is provided as a time series in "Iso_MP_Sap_DataDaily_ESSDiveUpload.csv" and the units are provided in "dd.csv"; the location of the instrumented trees and soil profiles are given as latitude and longitude coordinates saved as CSV and KMZ files; and a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata.The data was gathered to investigate the short-term changes of the water sources (i.e., variation of root water uptake from different soil depths) of the studied subalpine trees.Update 07/16/2025: The relative and absolute plant water uptake depths were grouped to ensure that the MixSIAR model was applied with endmembers that differed in their d2H value by at least 3 permill and at least 1 permill for d18O. Whenever the difference between observed d2H values for two or more probes at neighboring depths was less than 3 permill, we used the average value for the source water endmember. For days at which probes that were not next to each other measurements did not differ at least 3 permill, the average of all probes between these two depths was used as the water source endmember representing the depth range between these two probes.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Great Pyramid: Stand-Alone Monte Carlo Simulations for Detector Optimization

Cosmic-ray muon imaging has been used to non-destructively examine the Pyramids of Khufu and Khafre on the Giza Plateau; the EGP project will continue this line of research by undertaking a full tomographic scan of the former and, in doing so, will increase the sensitivity of the technique by upwards of two orders of magnitude. This paper details the development of stand-alone Monte Carlo simulations intended to aid in optimizing the EGP detector system. While the rectangular scintillator model considered here does provide sucient position resolution in a few specic test cases, it is not the optimal telescope design. An attempted detector modication to permit tagging of muons by their incident momenta is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Window Test Stand Status and Future Work [Slides]

Challenges to getting the window test stand running that were addressed. Initial design of half-anchor connector was insufficient. Accommodation of non-Rexolite windows required engineering.

42 ENGINEERING↗

Commissioning of Phase 1 of the LANL RFQ Test Stand - Beam Characterization

A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.

43 PARTICLE ACCELERATORS↗

Testing of PIP-II pre-production 650 MHz couplers in warm test stand and in cryomodule

650 MHz fundamental power couplers were developed for PIP-II project to deliver RF power for low-beta and high-beta elliptical cavities. Few prototypes were built and tested and after some modification we built 8 pre-production couplers (with few spares for vacuum side) for HB650 cryomodule. All couplers were successfully tested in pulse mode (up to 100kW) and in CW mode (up to 50kW) in test stand at full reflection at 8 phases. In baseline configuration with DC bias we do not see any multipactoring activity after short processing. We also tested power processing without bias for uncoated and TiN coated ceramic window. Results of these studies presented in this paper. One of the coupler was assembled on LB650 cavity and tested at cryogenic environment in STC cryostat at ~20kW power with full reflection at different reflection phase. We also demonstrated good result from power processing without bias for warm and cold cavity. Six couplers were assembled on HB650 cavities in pre-production cryomodule. Test results from cryomodule qualification is discussing in this paper.

43 PARTICLE ACCELERATORS↗

TPC Test-stands: An Overview & Future Prospects

The DUNE near detector design in Phase II will include a magnetized high-pressure gaseous-argon TPC (HPgTPC) surrounded by a calorimeter, called ND-GAr. ND-GAr is designed to provide fine-grained tracking, and due to its low detection threshold, it will be able to constrain one of the least-understood uncertainties for oscillation analysis: nuclear effects in argon at the neutrino interaction vertex. This talk will provide an overview of and an outlook about the ongoing R&D efforts in the context of the existing test stands that are evaluating the various readout system options for DUNE ND-GAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TinyTPC - A test stand for photosensitive dopants

LArTPCs highly doped with Xenon could be interesting platforms for probing MeV- and sub-MeV physics including neutrinoless-double beta decay. A main hurdle is the small fraction of scintillation photons that are collected, which significantly impacts LArTPCs' energy resolution. One solution is the use of photosensitive dopants, which convert light to charge. A team from Rutgers University and FNAL have built a test stand (TinyTPC) with a LArPix pixelated anode plane and an active mass of 2.1 kg to study these charge enhancements. Our plan is to measure the TinyTPC’s energy resolution with and without dopants for radioactive gamma sources, which is crucial for accurate calorimetric energy reconstruction of low-energy physics signals. The doping agent that will be used is isobutylene and the radiation sources are Co-60, Y-88, and Th-228.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TinyTPC - A Test Stand for Photosensitive Dopants

Liquid argon time projection chambers (LArTPCs) are widely used to study accelerator neutrinos. Since LArTPCs are sensitive down to 10– 100 keV, neutrino experiments' physics programs could be extended to lower energies. However, in this scale, LArTPCs' energy resolution is significantly degraded because only charge is collected efficiently. One solution is the introduction of photosensitive dopants, which convert scintillation light to ionization yield. We have built a test stand (TinyTPC) with a LArPix pixelated anode plane and an active mass of 2.1 kg to study these charge enhancements. Our plan is to measure TinyTPC’s energy resolution with and without dopants using radioactive sources. This poster presentation will discuss TinyTPC's status and goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operational Experience of a Cryomodule Test Stand for LCLS-II Cryomodules

CMTS1 (cryomodule test stand 1) at Fermilab was built to test cryomodules built for the LCLS-II beamline at SLAC and is currently testing cryomodules for LCLS-II-HE, the high energy upgrade to LCLS-II. The first cryomodule test was in 2016 and to date over 30 cryomodules have been tested here. This talk will highlight operational experience of the vacuum systems including insulating, coupler, and a low particulate beamline vacuum system. It will focus on the problems that have come up over the years, their solutions, and mitigations put in place to prevent further issues.

43 PARTICLE ACCELERATORS↗

Optimizing TinyTPC Test Stand for Low Energy Event Reconstruction

Introducing dopants into liquid argon offers a promising avenue to enhance the sensitivity and performance of LAr detectors such as DUNE. To explore this opportunity, we are optimizing and deploying the TinyTPC test stand, a compact time projection chamber with LArPix readout to study the effects of photosensitive dopants on the charge detected. TinyTPC enables comparative measurements of low-energy responses under various operational configurations and provides a platform to study the behavior of pixel readouts at low energy. We ensured system reliability through continuous current and voltage monitoring, modeling the detector's electrical behavior, and indirectly estimating total resistance under testing conditions. We ran the Blanche cryostat under various thresholds and gain configurations to evaluate their potential impact to low-energy event reconstruction and advancing R&D efforts for dopant integration in neutrino detectors

Van Loenen, Drew [Franciscan U. Steubenville]↗

Developing a GUI for the Robotic Test Stand

The introduction of this poster explains the technology behind DUNE’s far and near detectors and how passing neutrinos generate electrons that drift into a wire grid. I then explain how 3 ASICs manage signals received from electron interception. Next, the poster states how COLDATA chips are undergoing quality control by a Robotic Test Stand using a state machine. I further explained how earlier tests were done via a command line script and the necessity to implement a user-friendly Graphical User Interface with new features a command line can’t implement. For the implementation section, tools and methods for implementation are listed such as Python, tkinter, and GitHub as well as how multithreading and queue implementation was necessary for GUI functionality. Then, I elaborated on the GUIs new features. Finally, I explain how the GUI will be distributed across multiple institutions and future changes planned for the GUI. Photos of the RTS, far detector cave, diagram of anode assembly plane, COLDATA chips, set up tab, result tab, and legacy command line interface are shown.

Gutierrez Villanueva, Jaziel [DuPage Coll.]↗