Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Soft x-ray absorption spectroscopy and magnetic circular dichroism as operando probes of complex oxide electrolyte gate transistors

Electrolyte-based transistors utilizing ionic liquids/gels have been highly successful in the study of charge-density-controlled phenomena, particularly in oxides. Experimental probes beyond transport have played a significant role, despite challenges in their application in electric double-layer transistors. Here, we demonstrate the application of synchrotron soft x-ray absorption spectroscopy (XAS) and x-ray magnetic circular dichroism (XMCD) as operando probes of the charge state and magnetism in ion-gel-gated ferromagnetic perovskite films. Electrochemical response via oxygen vacancies at positive gate bias in LaAlO 3 (001)/La 0.5 Sr 0.5 CoO 3-δ is used as a test case. XAS/XMCD measurements of 4–25 unit-cell-thick films first probe the evolution of hole doping (from the O K-edge pre-peak) and ferromagnetism (at the Co L-edges), to establish a baseline. Operando soft XAS/XMCD of electrolyte-gated films is then demonstrated, using optimized spin-coated gels with a thickness of ~1 μm and a specific composition. The application of gate voltages up to +4 V is shown to dramatically suppress the O K-edge XAS pre-peak intensity and Co L-edge XMCD, thus enabling the Co valence and ferromagnetism to be tracked upon gate-induced reduction. Soft XAS and XMCD, with appropriate electrolyte design, are thus established to be viable for the operando characterization of electrolyte-gated oxides.

Yu, Biqiong↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Nanoindentation-Enhanced Tip-Enhanced Raman Spectroscopy

We combine nanoindentation, herein achieved using atomic force microscopy (AFM)-based pulsed-force lithography, with tip-enhanced Raman spectroscopy (TERS) and imaging. Our approach entails indentation and multimodal characterization of otherwise flat Au substrates, followed by chemical functionalization and TERS spectral imaging of the indented nanostructures. We find that the resulting structures, which vary in shape and size depending on the tip used to produce them, may sustain nano-confined and significantly enhanced local fields. We take advantage of the latter and illustrate TERS-based ultrasensitive detection/chemical fingerprinting as well as chemical reaction imaging – all using a single platform for nano-lithography, topographic imaging, hyperspectral dark field optical microscopy, and TERS.

Wang, Chih-Feng↗

Electron radiated power in cyclotron radiation emission spectroscopy experiments

The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio-frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near- and Extended-Edge X-Ray-Absorption Fine-Structure Spectroscopy Using Ultrafast Coherent High-Order Harmonic Supercontinua

Recent advances in high-order harmonic generation have made it possible to use a tabletop-scale setup to produce spatially and temporally coherent beams of light with bandwidth spanning 12 octaves, from the ultraviolet up to x-ray photon energies >1.6 keV. Here we demonstrate the use of this light for x-ray-absorption spectroscopy at the K- and L-absorption edges of solids at photon energies near 1 keV. We also report x-ray-absorption spectroscopy in the water window spectral region (284–543 eV) using a high flux high-order harmonic generation x-ray supercontinuum with 10 9 photons/s in 1% bandwidth, 3 orders of magnitude larger than has previously been possible using tabletop sources. Since this x-ray radiation emerges as a single attosecond-to-femtosecond pulse with peak brightness exceeding 10 26 photons/s/mrad 2 /mm 2 /1% bandwidth, these novel coherent x-ray sources are ideal for probing the fastest molecular and materials processes on femtosecond-to-attosecond time scales and picometer length scales.

74 ATOMIC AND MOLECULAR PHYSICS↗

Masses and β-Decay Spectroscopy of Neutron-Rich Odd-Odd 160,162 Eu Nuclei: Evidence for a Subshell Gap with Large Deformation at N = 98

The structure of deformed neutron-rich nuclei in the rare-earth region is of significant interest for both the astrophysics and nuclear structure fields. At present, a complete explanation for the observed peak in the elemental abundances at A ~ 160 eludes astrophysicists, and models depend on accurate quantities, such as masses, lifetimes, and branching ratios of deformed neutron-rich nuclei in this region. Unusual nuclear structure effects are also observed, such as the unexpectedly low energies of the first 2 + levels in some even-even nuclei at N = 98. In order to address these issues, mass and β-decay spectroscopy measurements of the 160 Eu 97 and 162 Eu 99 nuclei were performed at the Californium Rare Isotope Breeder Upgrade radioactive beam facility at Argonne National Laboratory. Here, evidence for a gap in the single-particle neutron energies at N = 98 and for large deformation (β 2 ~ 0.3) is discussed in relation to the unusual phenomena observed at this neutron number.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of nanoparticulate silicon as printed layers using scanning electron microscopy, transmission electron microscopy, X-ray absorption spectroscopy and X-ray photoelectron spectroscopy

The presence of native oxide on the surface of silicon nanoparticles is known to inhibit charge transport on the surfaces. Scanning electron microscopy (SEM) studies reveal that the particles in the printed silicon network have a wide range of sizes and shapes. High-resolution transmission electron microscopy reveals that the particle surfaces have mainly the (111)- and (100)-oriented planes which stabilizes against further oxidation of the particles. X-ray absorption spectroscopy (XANES) and X-ray photoelectron spectroscopy (XPS) measurements at the O 1 s -edge have been utilized to study the oxidation and local atomic structure of printed layers of silicon nanoparticles which were milled for different times. XANES results reveal the presence of the +4 (SiO 2 ) oxidation state which tends towards the +2 (SiO) state for higher milling times. Si 2 p XPS results indicate that the surfaces of the silicon nanoparticles in the printed layers are only partially oxidized and that all three sub-oxide, +1 (Si 2 O), +2 (SiO) and +3 (Si 2 O 3 ), states are present. The analysis of the change in the sub-oxide peaks of the silicon nanoparticles shows the dominance of the +4 state only for lower milling times.

36 MATERIALS SCIENCE↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

Quantifying Bulk and Surface Recombination in CdTe Solar Cells Using Time-Resolved Terahertz Spectroscopy

Understanding the nature of recombination mechanisms is essential for higher power conversion efficiency in photovoltaic (PV) devices. Here we use a combination of time-resolved terahertz spectroscopy and numerical modeling to determine the bulk Shockley-Read-Hall lifetime and interface and back surface recombination velocities in CdTe thin film stacks. Furthermore, the measurement was facilitated by fabricating wire-grid device structures using conventional laser scribing. Evaluation of a glass/FTO/SnO2/CdS/CdTe stack treated with CdCl2 allowed separation of the CdTe absorber bulk lifetime, 1.6 ns, from the back surface recombination velocity, ~6x10 4 cm/s, and indicated that CdTe/CdS interface recombination velocity had no significant impact on carrier dynamics.

14 SOLAR ENERGY↗

Evolution of Metastable Phases During Mg Metal Corrosion: An In Situ Cryogenic X-ray Photoelectron Spectroscopy Study

Magnesium and its alloys are potential structural materials candidates for a wide variety of applications due to their high strength-to-weight ratio. However, ductility and poor corrosion resistance under ambient environmental conditions are the bottleneck for industrial deployment. Designing passivation layers and/or corrosion resistant alloys requires fundamental understanding of the corrosion process. The traditional ex-situ spectroscopic measurements of polycrystalline metal surface with ubiquitous surface impurities and grain boundaries only provided an indistinct view of the corrosion process. To clearly distinguish the mechanism and sequence of corrosion process, we employed in-situ cryo-based x-ray photoelectron spectroscopy (XPS) measurements on Mg single crystal surface exposed to aqueous salt solution. Clean Mg (0001) surfaces were exposed to pure D2O and NaCl aqueous solution (5 wt% NaCl+95 wt% D2O). The interfacial reactions were studied using multimodal analysis including XPS, x-ray diffraction (XRD) and scanning electron microscopy (SEM). In contrast to previous studies, our experiments demonstrated the formation of magnesium chloride hydroxide hydrate during aqueous salt corrosion processes. Evidence of metastable ClO* radicals were also found during the initial aqueous salt solution exposure.

Shutthanandan, Vaithiyalingam↗

Non-Destructive Evaluation of Polyolefin Thermal Aging Using Infrared Spectroscopy

Fourier transform infrared (FTIR) spectroscopy is an information-rich method that reveals chemical bonding near the surface of polymer composites. FTIR can be used to verify composite composition, identify chemical contaminants and expose composite moisture content. Polymer matrix changes due to thermal exposure including loss of additives, chain scission, oxidation and changes in crystallinity may also be determined using FTIR spectra. Portable handheld instruments using non-contact reflectance or surface contact attenuated total reflectance (ATR) may be used for non-destructive evaluation (NDE) of thermal aging in polymer and composite materials of in-service components. We report the use of ATR FTIR to track oxidative thermal aging in ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE) materials used in medium voltage nuclear power plant electrical cable insulation and jacketing. Mechanical property changes of the EPR and CPE materials with thermal degradation for correlation with FTIR data are tracked using indenter modulus (IM) testing. IM is often used as a local NDE metric of cable jacket health. The FTIR-determined carbonyl index was found to increase with IM and may be a valuable NDE metric with advantages over IM for assessing cable remaining useful life.

aging↗

Two-dimensional fluorescence spectroscopy of laser-produced plasmas

We use a two-dimensional laser-induced fluorescence spectroscopy technique to measure the coupled absorption and emission properties of atomic species in plasmas produced via laser ablation of solid aluminum targets at atmospheric pressure. Emission spectra from the Al I 394.4 nm and Al I 396.15 nm transitions are measured while a frequency-doubled, continuous-wave, Ti:Sapphire laser is tuned across the Al I 396.15 nm transition. The resulting two-dimensional spectra show the energy coupling between the two transitions via increased emission intensity for both transitions during resonant absorption of the continuous-wave laser at one transition. Time-delayed and gated detection of the emission spectrum is used to isolate the resonantly-excited fluorescence emission from the thermally-excited emission from the plasma. In addition, the tunable continuous-wave laser measures the absorption spectrum of the Al transition with ultra-high resolution after the plasma has cooled, resulting in narrower spectral linewidths than observed in emission spectra. Our results highlight that fluorescence spectroscopy employing continuous-wave laser re-excitation after pulsed laser ablation combines benefits of both traditional emission and absorption spectroscopic methods.

Harilal, Sivanandan S.↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

Auger electron spectroscopy, secondary ion mass spectroscopy and optical characterization of a-C-H and BN films

The amorphous dielectrics a-C:H and BN were deposited on III-V semiconductors. Optical band gaps as high as 3 eV were measured for a-C:H generated by C4H10 plasmas; a comparison was made with bad gaps obtained from films prepared by CH4 glow discharges. The ion beam deposited BN films exhibited amorphous behavior with band gaps on the order of 5 eV. Film compositions were studied by Auger electron spectroscopy (AES), x-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS). The optical properties were characterized by ellipsometry, UV/VIS absorption, and IR reflection and transmission. Etching rates of a-C:H subjected to O2 dicharges were determined.

Pouch, J. J.↗

High resolution infrared spectroscopy from space: A preliminary report on the results of the Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment on Spacelab 3

The ATMOS (Atmospheric Trace Molecule Spectroscopy) experiment has the broad purpose of investigating the physical structure, chemistry, and dynamics of the upper atmosphere through the study of the distributions of the neutral minor and trace constituents and their seasonal and long-term variations. The technique used is high-resolution infrared absorption spectroscopy using the Sun as the radiation source, observing the changes in the transmission of the atmosphere as the line-of-sight from the Sun to the spacecraft penetrates the atmosphere close to the Earth's limb at sunrise and sunset. During these periods, interferograms are generated at the rate of one each second which yield, when transformed, high resolution spectra covering the 2.2 to 16 micron region of the infrared. Twenty such occultations were recorded during the Spacelab 3 flight, which have produced concentration profiles for a large number of minor and trace upper atmospheric species in both the Northern and Southern Hemispheres. Several of these species have not previously been observed in spectroscopic data. The data reduction and analysis procedures used following the flight are discussed; a number of examples of the spectra obtained are shown, and a bar graph of the species detected thus far in the analysis is given which shows the altitude ranges for which concentration profiles were retrieved.

Farmer, Crofton B.↗

The effect of Sr and Bi on the Si(100) surface oxidation - Auger electron spectroscopy, low energy electron diffraction, and X-ray photoelectron spectroscopy study

The effect of Sr and Bi on the oxidation of the Si(100) surface has been studied by Auger electron spectroscopy, low electron diffraction, and X-ray photoelectron spectroscopy. A dramatic enhancement, by a factor of 10, of the Si oxidation has been observed for Si(100) with a Sr overlayer. The SR-enhanced Si oxidation has been studied as a function of O2 exposure and Sr coverage. In contrast to the oxidation promotion of Sr on Si, it has been also observed that a Bi overlayer on Si(100) reduced Si oxidation significantly. Sr adsorption on the Si(100) with a Bi overlayer enhances Si oxidation only at Sr coverage of greater than 0.3 ML.

Fan, W. C.↗